Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “object reconstruction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Muon track reconstruction in a segmented bolometric array using multi-objective optimization

Recent advances in segmented solid-state detector arrays for rare-event searches have allowed the technology to approach the ton-scale in detector mass and the scale of meters in size. Often focused around searches for neutrinoless double-beta decay or direct dark matter detection, such experiments also have the capability to search for exotic particles that leave track-like signatures across their volume. However, the segmented nature of such detector arrays often sets the spatial resolution and makes the problem of reconstructing track-like paths non-trivial. Here, in this paper, we present an algorithm that improves reconstruction of track-like events in segmented detectors using multi-objective optimization — a computational technique that optimizes more than one cost function at a time without specifying a quantitative weighting between them. Such a technique allows the reconstruction of tracks through a detector and the determination of path-lengths through individual elements. When combined with the reconstructed energy depositions in each element this allows for a calculation of the stopping power of track-like particles and opens the door to searches for particles with abnormal stopping power like monopoles or lightly-ionizing particles (LIPs). Results are presented which evaluate the precision of the reconstruction tools as they currently stand against Monte Carlo generated data. The algorithm is presented in the context of the CUORE experiment, but has applications to other segmented calorimeter detectors.

47 OTHER INSTRUMENTATION↗

Wiener filtering of successive overlapping sections of an X-ray reconstruction

In this paper, a technique is developed to improve the image quality of an object in three-dimensional reconstruction by a weighted average of successive overlapping two-dimensional sections of the object. It is demonstrated that the signal-to-noise ratio of a two-dimensional picture can be improved by roughly a factor of 2 for typical X-ray beam shapes.

Reed, I. S.↗

X-ray imaging of extended objects using nonoverlapping redundant array

A common problem associated with X-ray imaging using coded apertures is the reconstruction of low-intensity extended objects. In the decoding of such objects, the overlapping images from the multiple pinholes give rise to noise cross talk and, in many cases, also to signal cross talk. In this paper, an alternate approach is proposed based on the principle used in an earlier (Yin et al., 1980) laboratory device for the real-time viewing of X-ray objects. It is shown that with this approach, the nonoverlapping redundant array, the sidelobes in the point spread function are not eliminated but merely displaced through a suitable choice of geometry. In this manner, the sidelobes no longer contribute to the background in the vicinity of a reconstructed image, and both signal and noise cross talks are completely eliminated. It may now be possible to reconstruct extended X-ray objects in 3-D by simple optical correlation and tomographically by a computer.

Yin, L.-I.↗

Reconstruction and identification of pairs of collimated τ-leptons decaying hadronically using s=13 TeV pp collision data with the ATLAS detector

This paper describes an algorithm for reconstructing and identifying a highly collimated hadronically decaying τ$$\tau $$-lepton pair with low transverse momentum. When two τ$$\tau $$-leptons are highly collimated, their visible decay products might overlap, degrading the reconstruction performance for each of the τ$$\tau $$-leptons. A dedicated treatment attempting to tag the τ$$\tau $$-lepton pair as a single object is required. The reconstruction algorithm is based on a large radius jet and its associated two leading subjets, and the identification uses a boosted decision tree to discriminate between signatures from τ+τ-$$\tau ^+\tau ^-$$ systems and those arising from QCD jets. The efficiency of the identification algorithm is measured in Zγ$$Z\gamma $$ events using proton–proton collision data at s=13$$\sqrt{s}=13$$ TeV collected by the ATLAS experiment at the Large Hadron Collider between 2015 and 2018, corresponding to an integrated luminosity of 139fb-1$$139\,\text{ fb}^{-1}$$. The resulting data-to-simulation scale factors are close to unity with uncertainties ranging from 26 to 37%.

Aad, G↗

Statistical analysis of SSME system data

A statistical methodology to enhance the Space Shuttle Main Engine (SSME) performance prediction accuracy is proposed. This methodology was to be used in conjunction with existing SSME performance prediction computer codes to improve parameter prediction accuracy and to quantify that accuracy. However, after a review of related literature, researchers concluded that the proposed problem required a coverage of areas such as linear and nonlinear system theory, measurement theory, statistics, and stochastic estimation. Since state space theory is the foundation for a more complete study of each of the before mentioned areas, these researchers chose to refocus emphasis to cover the more specialized topic of state vector estimation procedures. State vector estimation was also selected because of current and future concerns by NASA for SSME performance evaluation; i.e., there is a current interest in an improved evaluation procedure for actual SSME post flight performance as well as for post static test performance of a single SSME. A current investigation of analytical methods may be used to improve test stand failure detection. This paper considers the issue of post flight/test state variable reconstruction through the application of observations made on the output of the Space Shuttle propulsion system. Rogers used the Kalman filtering procedure to reconstruct the state variables of the Space Shuttle propulsion system. An objective of this paper is to give the general setup of the Kalman filter and its connection to linear regression. A second objective is to examine the reconstruction methodology for application to the reconstruction of the state vector of a single Space Shuttle Main Engine (SSME) by using static test firing data.

Temple, Enoch C.↗

Three-dimensional surface reconstruction for industrial computed tomography

Modern high resolution medical computed tomography (CT) scanners can produce geometrically accurate sectional images of many types of industrial objects. Computer software has been developed to convert serial CT scans into a three-dimensional surface form, suitable for display on the scanner itself. This software, originally developed for imaging the skull, has been adapted for application to industrial CT scanning, where serial CT scans thrrough an object of interest may be reconstructed to demonstrate spatial relationships in three dimensions that cannot be easily understood using the original slices. The methods of three-dimensional reconstruction and solid modeling are reviewed, and reconstruction in three dimensions from CT scans through familiar objects is demonstrated.

Vannier, M. W.↗

Photogrammetry of the solar aureole

This paper presents a photogrammetric analysis of the solar aureole for the purpose of making photographic sky radiance measurements for determining aerosol physical characteristics. A photograph is essentially a projection of a 3-D object space onto a 2-D image space. Photogrammetry deals with relations that exist between the object and the image spaces. The main problem of photogrammetry is the reconstruction of configurations in the object space by means of the image space data. It is shown that the almucantar projects onto the photographic plane as a conic section and the sun vertical as a straight line.

Deepak, A.↗

First experimental study of multiple orientation muon tomography, with image optimization in sparse data environments

Due to the high penetrating power of cosmic ray muons, they can be used to probe very thick and dense objects. As charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object, particle direction changes can be used to extract scattering information within an object. This can be used to produce a scattering intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies have been published with multi-orientation tomography, which can form a three-dimensional representation faster than a single orientation view. In this work we present the first experimental multiple orientation muon tomography study. Experimental muon-scatter based tomography was performed using a concrete filled steel drum with several different metal wedges inside, between detector planes. Data was collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were then combined using two different tomographic methods. Results showed that using a combination of multiple depth-of-field reconstructions, rather than a traditional inverse Radon transform approach used for CT, resulted in more useful images for sparser data. As cosmic ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedge compositions.

Applied Physics (physics.app-ph)↗

Reconstruction of internal density distributions in porous bodies from laser ultrasonic data

It is presently shown that, for density-reconstruction problems in which information about the inhomogeneity is known a priori, the nonlinear least-squares algorithm yields satisfactory results on the basis of limited projection data. The back-projection algorithm, which obviates assumptions about the objective function to be reconstructed, does not recover the boundary of the inhomogeneity when the number of projections is limited and ray-bending is ignored.

Lu, Yichi↗

Average Cross-Sectional Area of DebriSat Fragments Using Volumetrically Constructed 3D Representations

Debris fragments from the hypervelocity impact testing of DebriSat are being collected and characterized for use in updating existing satellite breakup models. One of the key parameters utilized in these models is the ballistic coefficient of the fragment which is directly related to its area‐to‐mass ratio. However, since the attitude of fragments varies during their orbital lifetime, it is customary to use the average cross‐sectional area in the calculation of the area‐to‐mass ratio. The average cross‐sectional area is defined as the average of the projected surface areas perpendicular to the direction of motion and has been shown to be equal to one‐fourth of the total surface area of a convex object. Unfortunately, numerous fragments obtained from the DebriSat experiment show significant concavity (i.e., shadowing) and thus we have explored alternate methods for computing the average cross‐sectional area of the fragments. An imaging system based on the volumetric reconstruction of a 3D object from multiple 2D photographs of the object was developed for use in determining the size characteristic (i.e., characteristics length) of the DebriSat fragments. For each fragment, the imaging system generates N number of images from varied azimuth and elevation angles and processes them using a space‐carving algorithm to construct a 3D point cloud of the fragment. This paper describes two approaches for calculating the average cross‐sectional area of debris fragments based on the 3D imager. Approach A utilizes the constructed 3D object to generate equally distributed cross‐sectional area projections and then averages them to determine the average cross‐sectional area. Approach B utilizes a weighted average of the area of the 2D photographs to directly compute the average cross‐sectional area. A comparison of the accuracy and computational needs of each approach is described as well as preliminary results of an analysis to determine the "optimal" number of images needed for the 3D imager to accurately measure the average cross sectional area of objects with known dimensions.

Scruggs, T.↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

Aperture codes for sensors viewing extended objects from space

The paper describes aperture codes viewing extended objects form space which find application in imaging an extended object which may have relatively low contrast, and whose lateral limits extend beyond the FOV of the sensor. Those elements of an extended object lying near the FOV limits are only partially coded, i.e., flux from those elements cannot cast a shadow of the entire aperture code onto the detector, as can elements near the center of the FOV. This has consequences for the algorithms used to reconstruct the image. The object field is divided into a number of elements which is smaller than the number of detector pixels, and a least squares fit to the data is performed. The methods used for choosing the matrices representing the aperture codes are discussed, and computer simulations of the effects of noise are described.

Curtis, C. C.↗

Algorithms for Forward and Inverse Problem Solutions in Phase Contrast Tomography

PhaseTorch is a python package that implements algorithms for forward and inverse problem solutions in X-ray phase contrast tomography (XPCT). XPCT is useful to reconstruct the 3D distribution of the refractive index decrement and absorption index of an imaged object. PhaseTorch implements algorithms for simulation, reconstruction, and analysis of XPCT data. PhaseTorch provides algorithms for simulation of XPCT data of an object with known refractive and absorption indices. It contains algorithms for reconstructing the projections of the absorption index and refractive index decrement.

Sridhar, Venkatesh↗

A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

97 MATHEMATICS AND COMPUTING↗

35-45 Giga Hertz Transceiver System for Phase and Magnitude Detection

Nondestructive evaluation (NDE) is the science and practice of examining an object in a way that the object's usefulness is not adversely affected. Different types of NDE methods exist but this thesis is based on microwave and millimeter wave NDE using imaging techniques. Microwave NDE is based on illuminating the object under test with a microwave signal and studying the various properties of the reflected signal from the object. This reflected signal contains some information about the inner structure of the object under test. This information may be contained in several parameters including the phase and magnitude of the reflected signal. The goal of this project is to design and build a Q-band coherent transceiver that is capable of measuring the reflected signal's phase and magnitude so that an image of the object under test may be reconstructed. From the several techniques that can be used to construct an image of the object under test, techniques of interest to this work include synthetic aperture focusing technique (SAFT) and microwave holography. The transceiver system should have the ability to sweep a large portion of Q-band frequency range in small frequency steps as quick as possible while the detected phase and magnitude of the reflected signal is very accurate. Several different designs were studied and the final schematic diagram of the transceiver system was determined. One of the most important modules that was designed, implemented and tested in the laboratory was an accurate phase/magnitude detector circuit. The compared results of the scans using the transceiver system and vector network analyzer (VNA) showed that this transceiver system has a great potential to replace a VNA for the purpose of microwave and millimeter wave imaging.

Beni, Aman Aflaki↗

Three-dimensional single-shot ptychography

Here we introduce three-dimensional single-shot ptychography (3DSSP). 3DSSP leverages an additional constraint unique to the single-shot geometry to deconvolve multiple 2D planes of a 3D object. Numeric simulations and analytic calculations demonstrate that 3DSSP reconstructs multiple planes in an extended 3D object with a minimum separation consistent with the depth of field for a conventional microscope. We experimentally demonstrate 3DSSP by reconstructing orthogonal hair strands axially separated by 5 mm. 3DSSP provides a pathway towards volumetric imaging of dynamically evolving systems on ultrafast timescales.

3DSSP↗

Signal-to-noise limitations in white light holography

A simple derivation is given for the SNR in images reconstructed from incoherent holograms. Dependence is shown to be on the hologram SNR, object complexity, and the number of pixels in the detector. Reconstruction of involved objects becomes possible with high-dynamic-range detectors such as CCDs. White-light holograms have been produced by means of a rotational shear interferometer combined with a chromatic corrector. A digital inverse transform recreated the object.

Ribak, Erez↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗