Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “nuclear data evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Machine learning-assisted identification of potential sources of bias in measurements of prompt-fission neutron spectra

Unrecognized sources of uncertainty (USU) can bias the reported mean and/or covariance of experimental nuclear data. These biases, in turn, can propagate through evaluated nuclear data to application simulations or may poorly inform nuclear theory that is fitted to the experimental data. Such unknown sources of bias must be tied to the inherent physical constituents of the measurements such as the characteristics of a detector response or a background reduction technique. Here, in this article, a sparse Bayesian learning model is used to support experts in their efforts to identify and characterize USU in experimental prompt fission neutron spectra (PFNS) for spontaneous fissioning of 252 Cf by linking observed biases to features of the measurement system. Three different bias components were found. The first acts as a verification case for the algorithm as it identifies a bias coming from a well-known source related to the use of 6 Li in the neutron detection system. The second two cases demonstrate how this method can benefit the evaluation of experimental nuclear data by identifying, quantifying, and relating unknown biases to potential causes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Validation of Thermal Scattering Laws for Light Water at Elevated Temperatures with Diffusion Experiments

Light water is the most important neutron moderator in many reactor applications. Thermal neutron scattering kernels for H bound in H 2 O are represented by ENDF-format thermal scattering laws (TSLs) evaluated at discrete temperatures T . Nuclear data evaluations are conventionally validated utilizing a combination of critical benchmarks and experimental cross section data. Existing public critical benchmarks may be inadequate for testing water TSLs over the full range of T of interest in reactor applications, and experimental thermal scattering cross section data for water is sparse at elevated T . In this work, MC21 is used to simulate the decay of the equilibrium thermal neutron flux in light-water spheres of several radii. The fundamental-mode time eigenvalue $\mathcal{a}$ is calculated at 22 °C and 227 °C (at saturation pressure) for each sphere using three different H-H 2 O TSLs. Fitting $\mathcal{a}$ to a polynomial function of geometric buckling allows calculation of the thermal neutron diffusion length L . Extrapolation lengths are treated as a function of the transport mean free path and geometry. Experimental L data from 25 publications at 49 temperatures (from 10 °C to 295 °C), computed by several different time-dependent and space-dependent decay methods, is used to develop an empirical fit of L vs. T . The MC21-calculated L for the TSLs tested are within ±1% of the predicted values at 22 °C and 227 °C. This validation approach, which may be repeated at arbitrary T , constitutes an integral benchmark specific to and characterizing the detailed physics of the thermal scattering kernel applied.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ENDF/B-VIII.0 Augmented Covariance Data The first iteration [Slides]

Nuclear data are necessary for reliable modeling and simulation of the next generation of nuclear reactors. However, the variation in the ratio of the computed to experimental values (C/E) for certain types of nuclear systems is much less than predicted by evaluated nuclear data file (ENDF)/B covariances. Figure 1 provides an example of a set of metal-plutonium-fueled, fast-spectrum (PU-MET-FAST) integral experiments from the International Criticality Safety Benchmark Evaluation Project (ICSBEP) in the Oak Ridge National Laboratory (ORNL) VALID database. The variation in the C/E values, shown with one standard deviation error bars, is 100% covered by both the SCALE and ENDB/VIII.0 covariance data. This is due to the comparisons to integral data that are essential during the evaluation process. However, the ENDF evaluations represent uncertainties and correlations in differential data only; they do not reflect the impact of the comparison to integral data in the covariance evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental uncertainty quantification using templates of expected measurement uncertainties for fast neutron-induced total, capture, and scattering cross sections

Careful experimental uncertainty quantification (UQ) is key for developing trustworthy evaluated nuclear data. Templates to account for missing or under-reported experimental uncertainties were recently developed by the covariance committee of Cross Section Evaluation Working Group (CSEWG). In this work, we illustrate the practical application and limitations of these templates for selected neutron-induced reactions, including (n, tot), (n, γ), and (n, xn) in the fast energy range, to illustrate their use in data analyses for nuclear data evaluations. We show that while the templates provide consistent framework, proper implementation still requires detailed knowledge of experimental conditions and careful treatment of nonlinear effects in cross section derivation. Case studies highlight how template-assisted UQ improves consistency with previous evaluations such as ENDF/B and reveals open challenges in propagating uncertainties across different energy regimes. The main contribution of this paper is to connect formal template recommendations with their use in practical evaluation workflows, clarifying both their benefits and current limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Python Library For Reading Endf Files

Evaluated Nuclear Data Files (ENDFs) are the most common way to store nuclear data. However, they are a hard-to-read format that few people or programs can read. OpenMC, an open source project, developed a way to read Evaluated Nuclear Data Files (ENDF) into a useful form for python. This library will remove all unnecessary code from OpenMC to focus solely on reading nuclear data. In addition, it will handle parsing Grouped cross-section data from an ENDF file, which OpenMC does not currently handle.

Gale, MicahD.↗

The Covariance of PFNS Results from the Chi-Nu Experiment

The prompt fission neutron spectrum (PFNS) from neutron-induced fission is a fundamental quantity for the behavior of nuclear reactors, and has been measured many times on a wide variety of nuclei and covering different ranges of incident and emitted neutron energies. However, results from past measurements are frequently called into question in modern nuclear data evaluations because of a lack of thorough experimental documentation and incomplete uncertainty analyses. The Chi-Nu experiment at Los Alamos National Laboratory was designed to produce high-precision measurements of the PFNS of major actinides over a wide range of incident and emitted neutron energies, and with the documentation and covariance analysis required to ensure that the results of this experiment maintain their impact long into the future, thereby avoiding this pitfall of past measurements. In this work we describe the Chi-Nu experiment along with summaries of the treatment of and methods developed to address two important components of the analysis of Chi-Nu data: random-coincidence backgrounds and MCNP simulations. Furthermore, we describe the first results for correlations not just between all data points collected on a single target nucleus, but also between all data points from separate Chi-Nu measurements on 235 U and 239 Pu. These correlations are important for accurately calculating ratios of the PFNS from one actinide to another, which are rare and can be informative for nuclear data evaluation efforts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Primer on Nuclear "Recoil" Data

For many years the ENDF-6 format has existed to contain evaluated nuclear data. One primary driver for the format and the data is neutron transport calculations. Evaluated data can be processed by a code like NJOY into either continuous energy form (ACE format) for Monte Carlo codes like MCNP or into multi-group form (NDI tables) for deterministic codes like Partisn. The reaction cross sections are found in the MF 3 section of the ENDF-6 format. If the reaction produces one or more neutrons as outputs, then secondary neutron data must also be given in MF 4,5 or 6 sections of the format. Energy and angular distributions for the output neutrons must be given in one of several available formats. The most general formats are found in MF 6. MF 4 is for angular distributions, MF 5 is for Energy distributions, and MF 6 contains both. In recent years, more interest has developed in the other output particles (i.e., the “recoil” particles) from neutron induced reactions. This has been driven by interest in charged particle transport and in more specialized partial kermas. ( A separate total neutron kerma has been available for a long time.) Partial kermas are a breakdown of the Kinetic Energy Released into the MAterial by output particle or by neutron reaction. The sum of the partial kermas should be equal to the total kerma on a group-wise basis. The ENDF-6 format is general enough for these new data requirements. Ideally, evaluated data would exist for every output particle (including the secondary neutrons) from every neutron-induced reaction. In the MF 6 format section, data for multi-particle outputs may be entered using the LAW =1 option. This option explicitly allows energy and angular output distributions for each particle produced in the reaction. Such information should preserve the balance between partial kermas and the total kerma at the groupwise level as well as the individual particle averaged energies. For simpler 2-body reactions, LAW = 2 is available. This allows the evaluation to specify only enough data to specify the 2-body reaction fully. Such a simplification does not exist for 3 (or more) body breakups. A simplified form of LAW 2, i.e., LAW 3, also exists to generate approximate recoil output distributions in the absence of full data. However, evaluated data does not generally exist at this fine granularity for reactions involving more than 2 output particles ( e.g., the 3-body break-up reaction). When the multi-body detailed output distribution data is not available, LAW=6 may be employed in NJOY. LAW 6 produces approximate output distributions for all the particles produced in the reaction. Just like in the 2-body case, the smaller particles will generally carry off more energy. At any particular energy, the balance between the sum of the partial kermas and the total kerma will not necessarily be preserved. However, the average energy of each output particle from a reaction is preserved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CEA/DAM - CEA/DEN - LANL - IAEA - IPHC Collaboration Meeting on Nuclear Data, Nuclear Reaction Theories, and Machine Learning (Summary Report)

Dupuis hosted our biennial CEA/NNSA collaboration meeting, and Kawano and Lovell of LANL and Tamagno of CEA/DEN (Cadarache) visited CEA/DAM to discuss current issues and further developments in nuclear reaction modeling, nuclear data evaluation, and relevant programs of modern computer science, especially the machine learning technology. The discussions included topics of our common interest such as neutron inelastic scattering, capture, and fission, with particular emphasis on the actinide nuclear data evaluations. We report briefly the summary of our discussions. We also had a half-day video meeting with Capote of IAEA and Kerveno of IPHC to discuss nuclear reactions on actinides.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Key Nuclear Data Impacting Reactivity in Advanced Reactors

Advanced reactor concepts currently being developed throughout the industry are significantly different from light water reactor (LWR) designs with respect to geometry, materials, and operating conditions, and consequently, with respect to their reactor physics behavior. Given the limited operating experience with non-LWRs, the accurate simulation of reactor physics and the quantification of associated uncertainties are critical for ensuring that advanced reactor concepts operate within the appropriate safety margins. Nuclear data are a major source of input uncertainties in reactor physics analysis. As part of an ongoing project at Oak Ridge National Laboratory (ORNL), the effects of nuclear data uncertainties on key figures of merit associated with advanced reactor safety are being assessed for selected advanced reactor technologies. Key nuclear data relevant for reactor safety analysis for each selected advanced reactor technology were identified, and their impact on important key figures of merit was assessed. Available advanced reactor specifications were reviewed, results from studies performed at ORNL and other research institutions were consulted, and available evaluated nuclear data libraries were analyzed. This report summarizes the key nuclear data for nuclides in the fuel, as well as other significant data, including scattering and neutron capture in various materials for the moderator, coolant, and structure of the considered advanced reactors. For the considered advanced reactors that use low-enriched uranium (LEU) fuel, results from LWR studies provided insight into relevant nuclear data given the lack of available studies specifically addressing these new systems. The major nominal missing data that were identified consist of thermal scattering data and 135m Xe cross section data for molten salt reactor (MSR) analysis. The identified major gaps with respect to nuclear data uncertainties are missing uncertainties of thermal scattering data for high temperature gas-cooled reactors and moderated MSR systems, and incomplete uncertainties on angular distributions in particular for fast spectrum systems, such as sodiumcooled fast reactors, fast molten salt reactors, and heat pipe reactors. Furthermore, it was found that special attention should be paid to cross section and uncertainty differences between different evaluated nuclear data library releases, because significant differences in nuclear data that can lead to major differences in reactivity calculations were found, even for well-known nuclides.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Role of Nuclear Data Sensitivities in Prompt α-Eigenvalue Predictions of Delayed Critical Benchmarks

Alpha (α) eigenvalues, which describe the logarithmic time derivative of the neutron population in a multiplying system, are integral to time-dependent behavior and diagnostic applications. However, uncertainties in the evaluated nuclear data can significantly impact the accuracy of transport simulations for such quantities. This work explores the use of machine learning models to predict two key outputs, α-eigenvalues and keff bias, using input features derived from α-eigenvalue sensitivities to nuclear data. The criticality safety benchmark models used in this study come from the International Handbook of Evaluated Criticality Safety Benchmark Experiments. Three models, random forest, XGBoost, and NGBoost, are trained on both energy-resolved and energy-summed α sensitivities. For the α-eigenvalue bias prediction, NGBoost achieved the highest R 2 (0.9476) using energy-resolved features, while XGBoost performed best using summed sensitivities. In contrast, when predicting the keff bias, all the models showed moderate predictive capability (best R 2 ≈ 0.72), as the mapping from the static α-sensitivities to the static keff bias was less direct. SHAP (SHapley Additive exPlanations) analysis was used to interpret the model predictions. Across both prediction tasks, the features associated with neutron capture [H-1 (n, γ)], uranium scattering reactions (such as 235 U elastic/inelastic), and actinide capture/fission reactions (such as 239 Pu and 234 U) were consistently identified as the most impactful. This highlights the key role of specific nuclear reactions and energy ranges in shaping both time-dependent and steady-state criticality behavior. These results demonstrated that α-sensitivities, despite being computed for time-dependent metrics, can provide valuable insights for predicting both α-eigenvalues and the keff bias. Moreover, machine learning models offer a promising pathway for uncovering important nuclear data dependencies and guiding future data evaluation efforts.

Nuclear data↗

(U) Jezebel Densities and Uncertainties

The 239 Pu Jezebel benchmark is a keystone for plutonium nuclear data evaluation. At a recent presentation at a nuclear data workshop, Morgan White (LANL P-27) presented a slide about the Jezebel plutonium-alloy part densities and their uncertainties. There are two major errors and one opinion presented as fact.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Monte Carlo Evaluation Framework for Imperfect Data and Models [Abstract]

Nuclear data evaluation methods conventionally make the following assumptions: prior and posterior probability distribution functions (PDFs) of all model parameters and data are normal (Gaussian); the linear approximation is sufficiently accurate for minimization of a cost function (even for non-linear models); and that both the model (of, e.g., neutron cross section) and experimental data (including their covariance data) are perfect. These assumptions are inherent to the well-known generalized linear least squares (GLLS) minimization method commonly used for evaluations of resolved resonance region (RRR) neutron cross sections. However, these assumptions are often not justified due to the presence of non-normal PDFs, non-linear models (e.g. R -matrix formalism), and inherent imperfections in data and models (e.g. discrepant data sets, discrepancies between the previous evaluation and newly measured data, or imperfect covariance data). We remove the said assumptions in a mathematical framework of Bayes’ theorem, and implement it using the Metropolis-Hastings Monte Carlo method. Parameters of a new kind are introduced to parameterize inherent imperfections, e.g. , any discrepancies between the theoretical model and measured data. These new parameters enable evaluators to quantify their expert judgement about any discrepancies or imperfections in a reproducible manner. We demonstrate the framework with an ongoing evaluation of 233 U in the eV region using the ENDF-B/VIII library and transmission data measured by Guber, et al. , and compare the posterior parameters to those obtained by conventional evaluation methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Data and Cross Section Testing Using ENDF/B-VIII.0

With the release of the Evaluated Nuclear Data File (ENDF)/B-VIII.0 library, nuclear criticality safety practitioners and engineers have access to the latest cross section sets available for their analyses. However, these cross sections must be rigorously tested and validated to ensure that the nuclear data are responsive to the needs of the individuals responsible for developing, implementing, and maintaining computational tools for criticality safety applications. Thus, the ENDF/B-VIII.0 library is tested and validated with a large collection of experiments that were vetted by the International Criticality Safety Benchmark Evaluation Project and made available in the International Handbook of Evaluated Criticality Safety Benchmark Experiments. A selection of benchmark experiments for use within the criticality safety community were prepared and reviewed within the Verified, Archived Library of Inputs and Data (VALID), which is maintained by the Nuclear Energy and Fuel Cycle Division at Oak Ridge National Laboratory. The performance of the ENDF/B-VIII.0 library is assessed by using VALID models of benchmark experiments with the beta 12 version of SCALE 6.3 KENO V.a and KENO-VI Monte Carlo codes. The performance is compared with the results obtained from with the ENDF/B-VII.1 library. This report considers multigroup (MG) and continuous energy (CE) formats of the ENDF/B-VIII.0 and -VII.1 libraries. The benchmark experiments within VALID that validate the ENDF/B-VIII.0 library cover 15 broad system categories by using a range of fissile materials, uranium enrichments, plutonium isotopic vectors, and mixed uranium/plutonium systems. These forms are represented as metals, solutions, or various arrays of rods or plates that cover a variety of neutron energy spectra: thermal, fast, mixed, and intermediate. Over 600 cases were considered for use with the KENO V.a and KENO-VI codes with the ENDF/B-VIII.0 library. The results of the Monte Carlo comparison of ENDF/B-VIII.0 to ENDF/B-VII.1 with both KENO V.a and KENO-VI indicate that there is a less than 0.53% Δk difference between the bias of calculated k eff from the expected values. The CE ENDF/B-VIII.0 library results in smaller magnitude biases than the ENDF/B-VII.1 data for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-SOL-THERM, PU-SOL-THERM, and U233-MET-FAST systems, while the MG results yielded smaller magnitude biases for HEU-MET-FAST, HEU-SOL-THERM, IEU-MET-FAST, LEU-COMP-THERM, LEU-SOL THERM, MIX-COMP-FAST, and U233-MET-FAST systems. Most notable are the adjustments to the plutonium and 233 U cross section data, which has resulted in noticeably lower biases in the ENDF/B VIII.0 results for the mixed, plutonium, and 233 U systems. Results of the sensitivity data file comparison generated from TSUNAMI-3D for selected VALID cases for the ENDF/B-VIII.0 library indicate a very high level of agreement with correlation coefficients of the effect of nuclear data uncertainty on k eff (the c k integral parameter) all above 0.99. This indicates that cases with the ENDF/B-VIII.0 library would see very similar responses to any nuclear data errors or change as those with the ENDF/B-VII.1 library.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Direct measurement of 59 Ni( n, p ) 59 Co and 59 Ni( n, α ) 56 Fe at fast-neutron energies from 500 keV to 10 MeV

We report nuclear reaction data for neutron induced reactions on unstable nuclei are critical for a wide range of applications spanning studies of nuclear astrophysics, nuclear reactor designs, and radiochemistry diagnostics. However, nuclear data evaluations of the reaction cross sections are largely based on calculations due to the difficulty in performing this class of measurements and the resulting lack of experimental data. For neutron induced charged particle reactions at fast neutron energies, at the MeV scale, these cross section predictions are predominately driven by statistical Hauser-Feshbach calculations. In this work, we present partial and total 59 Ni(n, p) and 59 Ni(n, α) cross sections, measured directly with a radioactive 59 Ni target, and compare the results to the present nuclear data evaluations. In addition, the results from this work are compared to a recent study of the 59 Ni(n, xp) reaction cross section that was performed via an indirect surrogate ratio method. The expected energy trend of the cross section, based on the current work, is inconsistent with that of the surrogate work. This calls into question the reliability of that application of the surrogate ratio method and highlights the need for direct measurements on unstable nuclei, when feasible.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Delayed Neutron Precursor Group Parameter and Spectra Generation from Fast Fission of 235U in SCALE

Delayed neutron precursor (DNP) group data are important for modeling reactor dynamics. Although the data for individual DNPs have been developed over time, the DNP group data present in the Evaluated Nuclear Data Files (ENDF) have not been updated in the past 20 years. In this work, we use SCALE to recreate the Godiva experiment that was used to generate the original DNP group structure for fast fission of 235U. However, each DNP is modeled using up-to-date data, and the results are then converted into a newly updated group structure. This conversion uses an iterative linear least squares solver to minimize chi-squared. The approaches used in this work also enable energy spectrum generation and uncertainty tracking. The method used in this paper for fast 235U fission DNP group structure updating can be applied to different energies and fissile nuclides. Demonstration of the uncertainty tracking in reactor kinetics and dynamics simulations is shown using point reactor kinetics simulations. Results show that there are data discrepancies between the International Atomic Energy Agency database and data used in ORIGEN, which are currently being fixed. Results also show that the proposed method for group spectra generation performs well.

Seifert, Luke [University of Illinois]↗

Development of nuclear data processing code FRENDY version 2

Nuclear data processing is an important interface between an evaluated nuclear data library and neutronics calculation codes. JAEA has been developed the new nuclear data processing code FRENDY from 2013. FRENDY version 1 generates the ACE files used for the continuous-energy Monte Carlo codes including PHITS, Solomon, Serpent,and MCNP and it was released as the open-source software under the 2-clause BSD license in 2019.After we released FRENDY version 1, many functions, e.g., the multi-group neutron cross-section library generation, the statistical uncertainty quantification of the probability tables for unresolved resonance cross-section, the 'perturbation' of the ACE file for uncertainty quantification, and the modification of the ENDF-6 formatted nuclear data file, have been developed. We released FRENDY version 2 including these functions. The present paper gives an overview of FRENDY and presents features of new functions implemented in FRENDY version 2. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Status of the WPEC subgroup 46 - Efficient and effective use of integral experiments for nuclear data validation

The present paper summarizes the current status of the activities of the on-going WPEC subgroup 46 which was the last significant initiative of Massimo before he passed away. The goal of WPEC/SG46 is to define, test and document a methodology to provide unambiguous feedback to the nuclear data evaluator community, based on the joint use of integral experiments and data assimilation techniques. Part of this effort resulted in a renewed analysis of the original Target Accuracy Requirement (TAR) exercise of WPEC/SG26, by adding more diverse nuclear systems and parameters, including reaction channels correlations and a coarser energy group structure; and making use of the progress made in the most recent evaluations in terms of both nuclear data and covariance matrices. The preliminary outcomes of the updated TAR exercise, documented by various groups worldwide are clear already: uncertainty reductions are required for many nuclide-reaction pairs in a variety of energy range if the target uncertainty requirements set by the industry are to be met, especially for k{sub eff}. The inclusion of correlations between the various reaction channels had a major impact on the magnitude of the required uncertainty reduction. Those uncertainty reductions are unlikely to be met by differential measurements alone. However, the selection of relevant integral experiment and a subsequent adjustment procedure may help meet these requirements. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Proceedings for the Workshop on Applied Nuclear Data Activities 2024

The Workshop for Applied Nuclear Data Activities (WANDA) is designed to increase communication among nuclear data (ND) users in multidisciplinary federal programs, ND producers, ND funders, and other ND experts. It also presents an opportunity to cross-pollinate ideas as well as introduce ND gaps identified by federal programs to ND experts and ND capabilities to the various federal ND users. WANDA 2024 included five technical sessions, three of which focused on Fusion Energy Sciences (FES)—FES Fusion Neutronics, FES Tritium Production, and FES Material Damage—and two stand-alone sessions—Isotopes and Targetry for Nuclear Data and Uncertainty Quantification. The FES sessions successfully brought new voices to the WANDA discussions, expanding the application space in which nuclear data are critical. FES programs need accurate nuclear data with realistic uncertainty quantification to properly estimate, for example, shielding, activation, tritium production, helium production, structural material integrity, and superconducting magnet operation. This includes a variety of projectile (neutrons, photons, charged particles) and target atoms. One of the action items common to all the FES sessions was a need to perform sensitivity studies to identify the prioritization of nuclear data needs. The Isotopes and Targetry session highlighted the many capabilities available to produce high-quality targets for nuclear data measurements, including 3D printing with spherical powders, combustion synthesis coupled with spin coating & electrospraying, inkjet printing, and isotopic doping. These new methods open doors for more accurate measurement, but it was also stressed that sample characterization following any method of fabrication is of the highest importance to accurately interpret nuclear data measurement results that used that sample. The Uncertainty Quantification (UQ) session was broken into two categories: nuclear data uncertainty quantification and the use of that uncertainty quantification. Thematic to the UQ session was the loss of information when going from nuclear data measurement, to evaluation, to evaluated file, and finally to neutron transport calculations. Current evaluated ND libraries typically only contain covariances, which assume that the probability distributions are Gaussian. Beyond being a simplified assumption for many evaluations, this can lead to negative values on many observables when attempting to sample the covariance. The covariance format, however, is very efficient in that a simple set of linear equations can transform uncertainty from parameters or cross sections to the application of interest. Focused collaboration is needed between nuclear data evaluators and nuclear data users to ensure that needs are being met.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗