Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “noninvasive monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Southwest Research Institute assistance to NASA in biomedical areas of the technology

Significant applications of aerospace technology were achieved. These applications include: a miniaturized, noninvasive system to telemeter electrocardiographic signals of heart transplant patients during their recuperative period as graded situations are introduced; and economical vital signs monitor for use in nursing homes and rehabilitation hospitals to indicate the onset of respiratory arrest; an implantable telemetry system to indicate the onset of the rejection phenomenon in animals undergoing cardiac transplants; an exceptionally accurate current proportional temperature controller for pollution studies; an automatic, atraumatic blood pressure measurement device; materials for protecting burned areas in contact with joint bender splints; a detector to signal the passage of animals by a given point during ecology studies; and special cushioning for use with below-knee amputees to protect the integrity of the skin at the stump/prosthesis interface.

Culclasure, D. F.↗

Imaging Modalities Relevant to Intracranial Pressure Assessment in Astronauts: A Case-Based Discussion

Introduction: Intracranial pressure (ICP) elevation has been inferred or documented in a number of space crewmembers. Recent advances in noninvasive imaging technology offer new possibilities for ICP assessment. Most International Space Station (ISS) partner agencies have adopted a battery of occupational health monitoring tests including magnetic resonance imaging (MRI) pre- and postflight, and high-resolution sonography of the orbital structures in all mission phases including during flight. We hypothesize that joint consideration of data from the two techniques has the potential to improve quality and continuity of crewmember monitoring and care. Methods: Specially designed MRI and sonographic protocols were used to image eyes and optic nerves (ON) including the meningeal sheaths. Specific crewmembers multi-modality imaging data were analyzed to identify points of mutual validation as well as unique features of complementary nature. Results and Conclusion: Magnetic resonance imaging (MRI) and high-resolution sonography are both tomographic methods, however images obtained by the two modalities are based on different physical phenomena and use different acquisition principles. Consideration of the images acquired by these two modalities allows cross-validating findings related to the volume and fluid content of the ON subarachnoid space, shape of the globe, and other anatomical features of the orbit. Each of the imaging modalities also has unique advantages, making them complementary techniques.

Sargsyan, Ashot E.↗

Current concepts in the pathophysiology, evaluation, and diagnosis of compartment syndrome

This article reviews present knowledge of the pathophysiology and diagnosis of acute compartment syndromes. Recent results using compression of legs in normal volunteers provide objective data concerning local pressure thresholds for neuromuscular dysfunction in the anterior compartment. Results with this model indicate that a progression of neuromuscular deficits occurs when IMP increases to within 35 to 40 mm Hg of diastolic blood pressure. These findings provide useful information on the diagnosis and compression thresholds for acute compartment syndromes. Time factors are also important, however, and usually are incompletely known in most cases of acute compartment syndrome. Although the slit catheter is a very good technique for monitoring IMP during rest, these catheters and their associated extracorporeal transducer systems are not ideal. Recently developed miniature transducer-tipped catheters and, perhaps, future development of noninvasive techniques may provide accurate recordings of IMP in patients with acute compartment syndromes.

NASA Discipline Cardiopulmonary↗

Near-Infrared Monitoring of Model Chronic Compartment Syndrome In Exercising Skeletal Muscle

Chronic compartment syndrome (CCS) is characterized by muscle ischemia, usually in the anterior oompartment of the leg, caused by high intramuscular pressure during exercise. Dual-wave near-infrared (NIR) spectroscopy is an optical technique that allows noninvasive tracking of variations in muscle tissue oxygenation (Chance et al., 1988). We hypothesized that with a model CCS, muscle tissue oxygenation will show a greater decline during exercise and a slower recovery post-exercise than under normal conditions.

Hargens, Alan R.↗

Measuring Intracranial Pressure And Volume Noninvasively

Ultrasonic technique eliminates need to drill into brain cavity. Intracranial dynamics instrument probes cranium ultrasonically to obtain data for determination of intracranial pressure (ICP) and pressure-volume index (PVI). Instrument determines sensitivity of skull to changes in pressure and by use of mechanical device to exert external calibrated pressure on skull. By monitoring volume of blood flowing into jugular vein, one determines change of volume of blood in cranial system. By measuring response of skull to increasing pressure (where pressure increased by tilting patient known amount) and by using cranial blood pressure, one determines intial pressure in cerebrospinal fluid. Once PVI determined, ICP determined.

Cantrell, John H.↗

The Choroidal Eye Oximeter - An instrument for measuring oxygen saturation of choroidal blood in vivo

The Choroidal Eye Oximeter is an electro-optical instrument that noninvasively measures the oxygen saturation of choroidal blood in the back of the human eye by a spectrophotometric method. Since choroidal blood is characteristic of blood which is supplied to the brain, the Choroidal Eye Oximeter can be used to monitor the amount of oxygen which is supplied to the brain under varying external conditions. The instrument consists of two basic systems: the optical system and the electronic system. The optical system produces a suitable bi-chromatic beam of light, reflects this beam from the fundus of the subject's eye, and onto a low-noise photodetector. The electronic system amplifies the weak composite signal from the photodetector, computes the average oxygen saturation from the area of the fundus that was sampled, and displays the value of the computed oxygen saturation on a panel meter.

Laing, R. A.↗

Development of a Multi-Channel, High Frequency QRS Electrocardiograph

With the advent of the ISS era and the potential requirement for increased cardiovascular monitoring of crewmembers during extended EVAs, NASA flight surgeons would stand to benefit from an evolving technology that allows for a more rapid diagnosis of myocardial ischemia compared to standard electrocardiography. Similarly, during the astronaut selection process, NASA flight surgeons and other physicians would also stand to benefit from a completely noninvasive technology that, either at rest or during maximal exercise tests, is more sensitive than standard ECG in identifying the presence of ischemia. Perhaps most importantly, practicing cardiologists and emergency medicine physicians could greatly benefit from such a device as it could augment (or even replace) standard electrocardiography in settings where the rapid diagnosis of myocardial ischemia (or the lack thereof) is required for proper clinical decision-making. A multi-channel, high-frequency QRS electrocardiograph is currently under development in the Life Sciences Research Laboratories at JSC. Specifically the project consisted of writing software code, some of which contained specially-designed digital filters, which will be incorporated into an existing commercial software program that is already designed to collect, plot and analyze conventional 12-lead ECG signals on a desktop, portable or palm PC. The software will derive the high-frequency QRS signals, which will be analyzed (in numerous ways) and plotted alongside of the conventional ECG signals, giving the PC-viewing clinician advanced diagnostic information that has never been available previously in all 12 ECG leads simultaneously. After the hardware and software for the advanced digital ECG monitor have been fully integrated, plans are to use the monitor to begin clinical studies both on healthy subjects and on patients with known coronary artery disease in both the outpatient and hospital settings. The ultimate goal is to get the technology out into the clinical world, where it has the potential to save lives.

DePalma, Jude L.↗

Data for Miscanthus giganteus Biolistic Transformation Using the Visible RUBY Red Marker Gene to Monitor Transformation Efficiency

Miscanthus × giganteus ( M × g ) is a high- yielding perennial C4 bioenergy crop, but genetic improvement by breeding is constrained by triploid sterility and clonal propagation. Improving genetic transformation methods for M × g would provide opportunities for advantageous trait introgression. Use of an easy to phenotype reporter gene is a promising strategy to improve transformation processes and efficiency. This study presents an efficient novel method for biolistic transformation of inflorescence- derived callus in M × g and demonstrates its efficacy using RUBY, a betalain-based noninvasive reporter that is visible throughout the transformation process. RUBY expression ( Zea mays codon optimized) was visible from callus stage through plantlet development into maturity. RUBY expressing independently transformed plants were confirmed by hygromycin phosphotransferase ELISA and by genomic PCR demonstrating that the RUBY phenotype is sufficient for screening transformants. The Zea mays codon optimized hygromycin selection marker was driven by previously established promoters for Miscanthus, ZmUBI and 2×35S, while the RUBY gene expression was controlled by a known Zea mays C4 promoter, Brachypodium UBI10, newly employed in Miscanthus. The construct containing the 2×35S promoter for hygromycin had a 15.1% transformation efficiency while the ZmUBI promoter had a 20.5% transformation efficiency. This study provides a novel, highly efficient protocol for successful biolistic transformation of M × g for stable expression. This study also demonstrates that RUBY expression can be used as a convenient and powerful monitor of transformation in ongoing and future work to engineer M × g into an improved bioproduct feedstock. **NOTE: in "TableS2_ProtocolComparison.csv", the data from row 665 to 971 should be removed.

Gene Editing↗

Miscanthus giganteus Biolistic Transformation Using the Visible RUBY Red Marker Gene to Monitor Transformation Efficiency

Miscanthus × giganteus ( M × g ) is a high-yielding perennial C4 bioenergy crop, but genetic improvement by breeding is constrained by triploid sterility and clonal propagation. Improving genetic transformation methods for M × g would provide opportunities for advantageous trait introgression. Use of an easy to phenotype reporter gene is a promising strategy to improve transformation processes and efficiency. This study presents an efficient novel method for biolistic transformation of inflorescence-derived callus in M × g and demonstrates its efficacy using RUBY, a betalain-based noninvasive reporter that is visible throughout the transformation process. RUBY expression ( Zea mays codon optimized) was visible from callus stage through plantlet development into maturity. RUBY expressing independently transformed plants were confirmed by hygromycin phosphotransferase ELISA and by genomic PCR demonstrating that the RUBY phenotype is sufficient for screening transformants. The Zea mays codon optimized hygromycin selection marker was driven by previously established promoters for Miscanthus, ZmUBI and 2×35S, while the RUBY gene expression was controlled by a known Zea mays C4 promoter, Brachypodium UBI10, newly employed in Miscanthus. The construct containing the 2×35S promoter for hygromycin had a 15.1% transformation efficiency while the ZmUBI promoter had a 20.5% transformation efficiency. This study provides a novel, highly efficient protocol for successful biolistic transformation of M × g for stable expression. This study also demonstrates that RUBY expression can be used as a convenient and powerful monitor of transformation in ongoing and future work to engineer M × g into an improved bioproduct feedstock.

RUBY↗

Frequency Domain Functional Near-Infrared Spectrometer (fNIRS) for Crew State Monitoring

A frequency domain functional near-infrared spectrometer (fNIRS) and accompanying software have been developed by the NASA Glenn Research Center as part of the Airspace Operations and Safety Program (AOSP) Technologies for Airplane State Awareness (TASA)—SE211 Crew State Monitoring (CSM) Project. The goal of CSM was to develop a suite of instruments to measure the cognitive state of operators while performing operational activities. The fNIRS was one of the instruments intended for the CSM, developed to measure changes in oxygen levels in the brain noninvasively.

Jeffrey R Mackey↗

Applications in Bioastronautics and Bioinformatics: Early Radiation Cataracts Detected by Noninvasive, Quantitative, and Remote Means

Human exploration of Mars is a key goal in NASA's exploration planning in the next 20 years. Maintaining crew health and good vision is certainly an important aspect of achieving a successful mission. Continuous radiation exposure is a risk factor for radiation-induced cataracts in astronauts because radiation exposure in space travel has the potential of accelerating the aging process (ref. 1). A patented compact device (ref. 2) based on the technique of dynamic light scattering (DLS) was designed for monitoring an astronaut's ocular health during long-duration space travel. This capability of early diagnosis, unmatched by any other clinical technique in use today, may enable prompt initiation of preventive/curative therapy. An Internet web-based system integrating photon correlation data and controlling the hardware to monitor cataract development in vivo at a remote site in real time (teleophthalmology) is currently being developed. The new technology detects cataracts very early (at the molecular level). Cataract studies onboard the International Space Station will be helpful in quantifying any adverse effect of radiation to ocular health. The normal lens in a human eye, situated behind the cornea, is a transparent tissue. It contains 35 wt % protein and 65 wt % water. Aging, disease (e.g., diabetes), smoking, dehydration, malnutrition, and exposure to ultraviolet light and ionizing radiation can cause agglomeration of the lens proteins. Protein aggregation can take place anywhere in the lens, causing lens opacity. The aggregation and opacification could produce nuclear (central portion of the lens) or cortical (peripheral) cataracts. Nuclear and posterior subcapsular (the membrane's capsule surrounds the whole lens) cataracts, being on the visual optical axis of the eye, cause visual impairment that can finally lead to blindness. The lens proteins, in their native state, are small in size. As a cataract develops, this size grows from a few nanometers (transparent) to several micrometers (cloudy). Ansari and Datiles have shown that DLS can detect cataracts at least two to three orders of magnitude earlier noninvasively and quantitatively than the best imaging (Scheimpflug) techniques in clinical use today (ref. 3).

Ansari, Rafat R.↗

Measurement of resistance to solute transport across surfactant-laden interfaces using a Fluorescence Recovery After Photobleaching (FRAP) technique

A noninvasive fluorescence recovery after photobleaching (FRAP) technique is under development to measure interfacial transport in two phase systems without disturbing the interface. The concentration profiles of a probe solute are measured in both sides of the interface by argon-ion laser, and the system relaxation is then monitored by a microscope-mounted CCD camera.

Browne, Edward P.↗

Investigating a Firn Aquifer near Helheim Glacier (South-Eastern Greenland) with Magnetic Resonance Soundings and Ground-Penetrating Radar

We apply the magnetic resonance sounding (MRS) method to investigate a firn aquifer in the south-east region of the Greenland ice sheet. Our study aims to delineate and estimate the volume of the recently discovered water stored within the firn (compacted snow) that remains liquid throughout the year. We develop and test successfully amethodology for joint use of MRS and ground-penetrating radar (GPR). This noninvasive geophysical approach is particularly well-adapted to glacier conditions and has a promising future for in situ investigation of water distribution in glaciers. At our field site, MRS showed an aquifer located at variable depths between 20 and 30 m beneath the ice-sheet surface. At the monitoring site, both MRS and GPR show an increase in the water volume stored between April 2015 and July 2016. MRS estimates suggest that the volume increased by approximately 28%.

meltwater↗

Regulated bioluminescence as a tool for bioremediation process monitoring and control of bacterial cultures

An effective on-line monitoring technique for toxic waste bioremediation using bioluminescent microorganisms has shown great potential for the description and optimization of biological processes. The lux genes of the bacterium Vibrio fischeri are used by this species to produce visible light. The lux genes can be genetically fused to the control region of a catabolic gene, with the result that bioluminescence is produced whenever the catabolic gene is induced. Thus the detection of light from a sample indicates that genetic expression from a specific gene is occurring. This technique was used to monitor biodegradation of specific contaminants from waste sites. For these studies, fusions between the lux genes and the operons for naphthalene and toluene/xylene degradation were constructed. Strains carrying one of these fusions respond sensitively and specifically to target substrates. Bioluminescence from these cultures can be rapidly measured in a nondestructive and noninvasive manner. The potential for this technique in this and other biological systems is discussed.

Burlage, Robert S.↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗

Noninvasive measurement of pulsatile intracranial pressure using ultrasound

The present study was designed to validate our noninvasive ultrasonic technique (pulse phase locked loop: PPLL) for measuring intracranial pressure (ICP) waveforms. The technique is based upon detecting skull movements which are known to occur in conjunction with altered intracranial pressure. In bench model studies, PPLL output was highly correlated with changes in the distance between a transducer and a reflecting target (R2 = 0.977). In cadaver studies, transcranial distance was measured while pulsations of ICP (amplitudes of zero to 10 mmHg) were generated by rhythmic injections of saline. Frequency analyses (fast Fourier transformation) clearly demonstrate the correspondence between the PPLL output and ICP pulse cycles. Although theoretically there is a slight possibility that changes in the PPLL output are caused by changes in the ultrasonic velocity of brain tissue, the decreased amplitudes of the PPLL output as the external compression of the head was increased indicates that the PPLL output represents substantial skull movement associated with altered ICP. In conclusion, the ultrasound device has sufficient sensitivity to detect transcranial pulsations which occur in association with the cardiac cycle. Our technique makes it possible to analyze ICP waveforms noninvasively and will be helpful for understanding intracranial compliance and cerebrovascular circulation.

NASA Center ARC↗

Optoelectronic Instrument Monitors pH in a Culture Medium

An optoelectronic instrument monitors the pH of an aqueous cell-culture medium in a perfused rotating-wall-vessel bioreactor. The instrument is designed to satisfy the following requirements: It should be able to measure the pH of the medium continuously with an accuracy of 0.1 in the range from 6.5 to 7.5. It should be noninvasive. Any material in contact with the culture medium should be sterilizable as well as nontoxic to the cells to be grown in the medium. The biofilm that inevitably grows on any surface in contact with the medium should not affect the accuracy of the pH measurement. It should be possible to obtain accurate measurements after only one calibration performed prior to a bioreactor cell run. The instrument should be small and lightweight. The instrument includes a quartz cuvette through which the culture medium flows as it is circulated through the bioreactor. The cuvette is sandwiched between light source on one side and a photodetector on the other side. The light source comprises a red and a green light-emitting diode (LED) that are repeatedly flashed in alternation with a cycle time of 5 s. The responses of the photodiode to the green and red LEDs are processed electronically to obtain a quantity proportional to the ratio between the amounts of green and red light transmitted through the medium.

Anderson, Melody M.↗

Correlation of Surface Acoustic Wave (SAW) force myography sensor output with elbow joint torque

Accurate assessment of skeletal muscle forces and net joint torque is essential for preventing fatigue-related injuries, optimizing physical training, and monitoring disease progression in neuromuscular conditions. However, existing joint torque evaluation techniques are hindered by limited portability and high operational costs, confining their use to controlled laboratory or clinical settings. Despite substantial advances in wearable joint torque estimation systems, ongoing challenges such as power constraints, bulky wired setups, and susceptibility to environmental or motion artifacts underscore the urgent need for truly batteryless, wireless solutions deployable in real-world settings. This paper proposes a novel surface acoustic wave (SAW)-based force myography (FMG) system for noninvasive measurement of joint torque, validated against a gold-standard electromechanical dynamometer. The approach uses a single SAW sensor embedded in an armband to detect volumetric biceps brachii changes, with a second-order polynomial mapping sensor output and elbow angle to torque. Seven participants were tested in both isometric (15°–90°) and isokinetic (10°/s and 20°/s) supinated elbow flexion tasks. Under isometric conditions, subject-specific calibration achieved a normalized root-mean-square error (NRMSE) of 13.6% ± 6.0% and R 2 = 0.834 ± 0.180, while a group-level model yielded 14.4% ± 6.8% and 0.808 ± 0.208, respectively. For isokinetic trials, the group model produced an NRMSE of 24.1% ± 6.6% at 10°/s and 24.9% ± 08.9% at 20°/s, highlighting the feasibility of using a single-sensor SAW-FMG setup across different speeds. Because SAW devices support wireless, battery-free operation, the proposed system offers a pathway to portable, real-time monitoring for sports medicine, rehabilitation, and clinical diagnostics.

36 MATERIALS SCIENCE↗