Microprobe Attachment for Quantitative Studies of Cathode Luminescence
Monochromator photomultiplier attachment to electron microprobe for measuring luminescence of enstatite
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Monochromator photomultiplier attachment to electron microprobe for measuring luminescence of enstatite
Thermospheric densities and temperatures from solar EUV radiation atmospheric absorption measurements by OSO 3 satellite monochromator, comparing satellite and rocket data
Diffusion pump oil reflectance and absorption coefficients measured in three thicknesses using light source, monochromator and detector
Combination of ultrahigh vacuum monochromator with ultrahigh vacuum reflectometer for measuring optical constants of solids
Photon intensities of UV spectral lines from energetic magnetically confined vacuum carbon arc, using monochromator double ion chamber detector system
Oxygen and carbon dioxide continua absorption cross sections in Schumann and far UV regions by photoelectric technique with vacuum monochromator
Mariner 6 and 7 UV spectrometers, describing technical details, operating characteristics and calibration of planetary coronagraph and Ebert- Fastie monochromator used for Martian atmosphere analysis
Solar Fe XIV 5303 coronal line isolation, using solid Fabry-Perot interferometer as monochromator
Two cylindrical shutter mechanisms having fixed outer sleeves and rotating inner sleeves use single stepping motor and Geneva mechanism to sequentially move optical components into path of ultraviolet monochromator for output control to photomultiplier. Photometric and wavelength calibration sources insure shutter positions according to operational phases.
High intensity ultraviolet radiation source was developed which is suitable for emission below 500 A. Source, useful for 100 to 1000 A range, is simple and inexpensive to construct, easy to operate, and very stable. Because of sufficiently intense output spectrum, source can be used with monochromator at wavelengths as low as 160 A.
Results of theoretical analyses of 12 problems are presented and comparisons of theoretical and experimental results are given. The investigations covered were: (1) techniques for improving the Saturn radar altimeter, (2) performance of the phase lock loop of the offset Doppler transponder, (3) signal processing equipment design for an orbital altitude radar return experiment, (4) spectral studies of signals present in the command and communication system (CCS) up-link transmitter, (5) intermodulation in the CCS down-link data demodulators, (6) error rate performance of the CCS transponder command demodulator, (7) flame attenuation effects on telemetry transmissions during Saturn launches, (8) design of a digital television system which converts a standard monochrome picture to a slow-scan picture, (9) methods of obtaining an additional CCS 72-kilobit/sec telemetry channel, (10) computation of the CCS S-band down-link spectra, (11) modeling of portions of the communications systems, and (12) modeling of a telemetry transmitter.
The effects of ultraviolet radiation on the infrared reflectance of ZnO silicone white thermal coatings were investigated. Narrow band ultraviolet radiation for wavelengths in the 2200A to 3500A range by a monochromator and a high pressure, 150-W Eimac xenon lamp. The sample was irradiated while in a vacuum of at least 0.000001 torr, and infrared reflectance was measured in situ with a spectroreflectometer at 19,500A. Reflectance degradation was studied as a function of wavelength, time, intensity, and dose. Damage was wavelength dependent at constant exposure, but no maximum was evident above the shortest wavelength investigated here. The degradation rate at constant intensity was an exponential function of time and varies with intensity.
A 0.5 meter focal length, plane grating monochromator was used to measure the radiance of spectral radiation emanating from regions downstream of a mercury bombardment thruster. The wavelength range investigated was 2800 A. This radiation was due primarily to the radiative decay of excited mercury atoms exhausted from the thruster. Radiance values ranged from 10 to the minus 11th power to 10 to the minus 9th power W/sq cm sr, varying with wavelength. For resonant radiation, the spectral radiance may exceed 10 to the minus 8th power W/sq cm sr. From such radiance measurements, it was concluded that the thruster background radiation should not interfere with the control functions of a star tracker viewing through the thruster exhaust, provided that the tracker is designed to operate with a sufficiently small field of view.
A device and method are provided for performing qualitative and quantitative elemental analysis through the utilization of a vacuum UV chromatographic detector. The method involves the use of a carrier gas at low pressure. The gas carries a sample to a gas chromatograph column; the column output is directed to a microwave cavity. In this cavity, a low pressure microwave discharge produces fragmentation of the compounds present and generates intense atomic emissions in the vacuum ultraviolet. These emissions are isolated by a monochromator and measured by photometer to establish absolute concentration for the elements.
The development of experimental setups and procedures is considered for calibrating photosensitive devices in the spectral range 1022 to 2500 A for which no direct calibration techniques exist. An indirect technique that uses a sodium salicylate detector calibrated outside this range was developed for use as a secondary standard. The primary standard was a xenon-filled ionization chamber, which is an absolute standard over the wavelength interval 972 to 1022 A. Measurements made by this method were checked at 1470 A with a xenon lamp and at 2537 A with a mercury arc lamp and a 0.5 m blaze monochromator with a grating blazed at 2000 A. The overall accuracy of the measurements was + or - 40 percent or better.
The optical constants of platinum and gold thin films have been determined in the spectral region of 40 to 200 nm by reflection measurements. The highly polarized continuum of synchrotron radiation emitted by the 240-MeV electron storage ring at the Physical Sciences Laboratory of the University of Wisconsin was used as a light source for the spectrum below 120 nm, while a windowless discharge lamp coupled to a normal incidence monochromator provided a source for the longer wavelengths. Optical constants were determined by a computer program based on iterative solutions to the Fresnel equations for reflection as a function of the angle of incidence.
Atomic-nitrogen multiplets have been excited. The excitation cross sections have been measured over the energy range from threshold to 350 eV. The transition arrays, mean wavelengths, and cross sections for dissociative excitation of the multiplets at 100 eV are presented. The experiment featured a monoenergetic electron beam which was incident on a quasi-static gas target. Vacuum-ultraviolet emission features were isolated by a normal-incidence monochromator, and multiscaling pulse-counting techniques were used.
Measurement of the relative cross section for photodetachment of electrons from PH2(-) in the wavelength region 725 to 1020 nm (1.71 to 1.22 eV). An ion cyclotron resonance spectrometer was used to generate, trap, and detect the negative ions, and two light sources were employed to study photodetachment: a 1000-W xenon arc lamp with a grating monochromator and a continuously tunable laser. A single sharp threshold in the cross-section curve was observed, and a detailed analysis yielded an electron affinity value of 1.25 plus or minus 0.03 eV.