Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “module temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An Observationally-Based Determination of the Arctic Sea Ice-Cloud Feedback Since 2000: Isolating the Arctic Cloud Response to Sea Ice Loss

Arctic sea ice responds to and drives Arctic climate change. The interactions between Arctic sea ice and clouds represent a mechanism through which sea ice can drive climate change. We composite active remote sensing satellite cloud properties for ice-free, marginal ice zone (MIZ), and ice-covered surfaces during MIZ crossing events to investigate the influence of the transition from an ice-covered to an ice-free surface on low-level clouds. We demonstrate that the event-based methodology controls for large-scale meteorological factors and isolates the sea ice effect on clouds. We find larger cloud fraction and total water content below ~1.5 km over ice-free relative to ice-covered surfaces during non-summer months, indicating a low-level cloud sensitivity to Arctic sea ice decline. During summer, results show larger cloud fraction and water content over ice-free surfaces, however the differences are statistically indistinguishable. Evidence is provided that atmospheric thermodynamic profile differences cause the cloud property differences, namely that ice-free footprints are warmer, moister, have more positive surface turbulent fluxes and are less stable than their ice-covered counterparts. Ice-free and ice-covered surface cloud property differences scale with surface temperature differences such that cloud property differences are only found in the presence of a surface temperature difference. We conclude that surface temperature differences modulate the cloud response to sea ice loss through influences on surface turbulent fluxes and lower tropospheric stability. The results imply a positive non-summer sea ice-cloud feedback and that up to a 0.02 cloud fraction and 0.05 g m 3 total water content increase in fall are due to the observed sea ice decline.

Patrick C Taylor↗

Estimating the Arctic Cloud-Sea Ice Feedback With Observations during the EOS Period

Arctic sea ice responds to and drives Arctic climate change. The interactions between Arctic sea ice and clouds represent a mechanism through which sea ice can drive climate change. We composite active remote sensing satellite cloud properties for ice-free, marginal ice zone (MIZ), and ice-covered surfaces during MIZ crossing events to investigate the influence of the transition from an ice-covered to an ice-free surface on low-level clouds. We demonstrate that the event-based methodology controls for large-scale meteorological factors and isolates the sea ice effect on clouds. We find larger cloud fraction and total water content below ~1.5 km over ice-free relative to ice-covered surfaces during non-summer months, indicating a low-level cloud sensitivity to Arctic sea ice decline. During summer, results show larger cloud fraction and water content over ice-free surfaces, however the differences are statistically indistinguishable. Evidence is provided that atmospheric thermodynamic profile differences cause the cloud property differences, namely that ice-free footprints are warmer, moister, have more positive surface turbulent fluxes and are less stable than their ice-covered counterparts. Ice-free and ice-covered surface cloud property differences scale with surface temperature differences such that cloud property differences are only found in the presence of a surface temperature difference. We conclude that surface temperature differences modulate the cloud response to sea ice loss through influences on surface turbulent fluxes and lower tropospheric stability. The results imply a positive non-summer sea ice-cloud feedback and that up to a 0.02 cloud fraction and 0.05 g m 3 total water content increase in fall are due to the observed sea ice decline.

Patrick C. Taylor↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

A Simplified Model of VIPER Thermal Management System. Part I: Loop Heat Pipe

NASA’s Volatiles Investigating Polar Exploration Rover (VIPER) uses a combination of loop heat pipes (LHPs) and heaters as the primary hardware to modulate the temperature of the electronic boxes and payloads instruments. LHPs have been designed and instrumented to be capable of passive and active shutdown. The goal of the passive shutdown, using a thermal control valve (TCV) to limit the flow of the working fluid, is to preserve thermal energy and avoid unnecessary heat leaks during lunar night. The goal of the active shutdown on the other hand, is to forcefully increase the vehicle internal temperature to bakeout the payload instruments. Several numerical modeling tools are available to analyze LHP performance under the complex set of operational requirements and environments levied on the VIPER Thermal Management System (TMS). Yet, while those numerical modeling tools are capable of detailed performance analysis, they tend to take large computational resources and long computational time. In this paper, a model of a single LHP developed based on control volume approach is presented. By using the control volume approach, the complex geometry of the LHP, and the components attached to it, are reduced to thermal lump capacitances, thus reducing the computation effort. This paper also describes the effort to correlate the proposed LHP model using thermal vacuum (TVAC) test data.

Loop Heat Pipe↗

In Site Analysis of a High Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high temperature (330 C) polymerization reaction was successfully monitored in real time using a modulated fiber-optic FT-Raman spectrometer. A phenylethynyl terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Cooper, John↗

Outline for an exploratory study on the design of lunar base habitats

The paper is concerned with the design of pneumatic structures which can be sent to the surface of the moon in a relatively small package and then opened to provide a large pressurized volume with life support systems to support a population of 12 people. A proposed system consists primarily of a Kevlar membrane which will support the internal pressures of the environment, a rigid pallet which will house all the life-support systems, and wall foam which provides sound and temperature insulation. The modules would be covered by three meters of lunar soil for radiation and temperature insulation. Site preparation, module connection, and characteristics of different modules are considered.

Trotti, G.↗

In Situ Analysis of a High-Temperature Cure Reaction in Real Time Using Modulated Fiber-Optic FT-Raman Spectroscopy

The vibrational spectrum of a high-temperature (330 C) polymerization reaction was successfully monitored in real time with the use of a modulated fiber-optic Fourier transform (FT)-Raman spectrometer. A phenylethynyl-terminated monomer was cured, and spectral evidence for two different reaction products was acquired. The products are a conjugated polyene chain and a cyclized trimer. This is the first report describing the use of FT-Raman spectroscopy to monitor a high temperature (greater than 250 C) reaction in real time.

Aust, Jeffrey F.↗

High-Temperature, Wirebondless, Ultracompact Wide Bandgap Power Semiconductor Modules

Silicon carbide (SiC) and other wide bandgap semiconductors offer great promise of high power rating, high operating temperature, simple thermal management, and ultrahigh power density for both space and commercial power electronic systems. However, this great potential is seriously limited by the lack of reliable high-temperature device packaging technology. This Phase II project developed an ultracompact hybrid power module packaging technology based on the use of double lead frames and direct lead frame-to-chip transient liquid phase (TLP) bonding that allows device operation up to 450 degC. The new power module will have a very small form factor with 3-5X reduction in size and weight from the prior art, and it will be capable of operating from 450 degC to -125 degC. This technology will have a profound impact on power electronics and energy conversion technologies and help to conserve energy and the environment as well as reduce the nation's dependence on fossil fuels.

Elmes, John↗

Hubble Space Telescope solar cell module thermal cycle test

The Hubble Space Telescope (HST) solar array consists of two identical double roll-out wings designed after the Hughes flexible roll-up solar array (FRUSA) and was developed by the European Space Agency (ESA) to meet specified HST power output requirements at the end of 2 years, with a functional lifetime of 5 years. The requirement that the HST solar array remain functional both mechanically and electrically during its 5-year lifetime meant that the array must withstand 30,000 low Earth orbit (LEO) thermal cycles between approximately +100 and -100 C. In order to evaluate the ability of the array to meet this requirement, an accelerated thermal cycle test in vacuum was conducted at NASA's Marshall Space Flight Center (MSFC), using two 128-cell solar array modules which duplicated the flight HST solar array. Several other tests were performed on the modules. The thermal cycle test was interrupted after 2,577 cycles, and a 'cold-roll' test was performed on one of the modules in order to evaluate the ability of the flight array to survive an emergency deployment during the dark (cold) portion of an orbit. A posttest static shadow test was performed on one of the modules in order to analyze temperature gradients across the module. Finally, current in-flight electrical performance data from the actual HST flight solar array will be tested.

Douglas, Alexander↗

Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph

A single-pixel prototype of a W-band detector module with a digital back-end was developed to serve as a building block for large focal-plane arrays of monolithic millimeter-wave integrated circuit (MMIC) detectors. The module uses low-noise amplifiers, diode-based mixers, and a WR10 waveguide input with a coaxial local oscillator. State-of-the-art InP HEMT (high electron mobility transistor) MMIC amplifiers at the front end provide approximately 40 dB of gain. The measured noise temperature of the module, at an ambient temperature of 300 K, was found to be as low as 450 K at 95 GHz. The modules will be used to develop multiple instruments for astrophysics radio telescopes, both on the ground and in space. The prototype is being used by Stanford University to characterize noise performance at cryogenic temperatures. The goal is to achieve a 30-50 K noise temperature around 90 GHz when cooled to a 20 K ambient temperature. Further developments include characterization of the IF in-phase (I) and quadrature (Q) signals as a function of frequency to check amplitude and phase; replacing the InP low-noise amplifiers with state-of-the-art 35-nm-gate-length NGC low-noise amplifiers; interfacing the front-end module with a digital back-end spectrometer; and developing a scheme for local oscillator and IF distribution in a future array. While this MMIC is being developed for use in radio astronomy, it has the potential for use in other industries. Applications include automotive radar (both transmitters and receivers), communication links, radar systems for collision avoidance, production monitors, ground-penetrating sensors, and wireless personal networks.

Kangaslahti, Pekka P.↗

A hybrid electronically scanned pressure module for cryogenic environments

Pressure is one of the most important parameters measured when testing models in wind tunnels. For models tested in the cryogenic environment of the National Transonic Facility at NASA Langley Research Center, the technique of utilizing commercially available multichannel pressure modules inside the models is difficult due to the small internal volume of the models and the requirement of keeping the pressure transducer modules within an acceptable temperature range well above the -173 degrees C tunnel temperature. A prototype multichannel pressure transducer module has been designed and fabricated with stable, repeatable sensors and materials optimized for reliable performance in the cryogenic environment. The module has 16 single crystal silicon piezoresistive pressure sensors electrostatically bonded to a metalized Pyrex substrate for sensing the wind tunnel model pressures. An integral temperature sensor mounted on each silicon micromachined pressure sensor senses real-time temperature fluctuations to within 0.1 degrees C to correct for thermally induced non-random sensor drift. The data presented here are from a prototype sensor module tested in the 0.3 M cryogenic tunnel and thermal equilibrium conditions in an environmental chamber which approximates the thermal environment (-173 degrees C to +60 degrees C) of the National Transonic Facility.

Chapman, J. J.↗

Advanced development receiver thermal vacuum tests with cold wall

The first ever testing of a full size solar dynamic heat receiver using high temperature thermal energy storage was completed. The heat receiver was designed to meet the requirements for operation on the Space Station Freedom. The purpose of the test program was to quantify the receiver thermodynamic performance, its operating temperatures, and thermal response to changes in environmental and power module interface boundary conditions. The heat receiver was tested in a vacuum chamber with liquid nitrogen cold shrouds and an aperture cold plate to partially simulate a low Earth orbit environment. The cavity of the receiver was heated by an infrared quartz lamp heater with 30 independently controllable zones to produce flux distributions typical of candidate concentrators. A closed Brayton cycle engine simulator conditioned a helium xenon gas mixture to specific interface conditions to simulate various operational modes of the solar dynamic power module. Inlet gas temperature, pressure, and flow rate were independently varied. A total of 58 simulated orbital cycles were completed during the test conduct period. The test hardware, execution of testing, test data, and post test inspections are described.

Sedgwick, Leigh M.↗

Development of Space-Flight Compatible Room-Temperature Electronics for the Lynx X-Ray Microcalorimeter

We are studying the development of space-flight compatible room-temperature electronics for the Lynx x-ray microcalorimeter (LXM) of the Lynx mission. The baseline readout technique for the LXM is microwave SQUID multiplexing. The key modules at room temperature are the RF electronics module and the digital electronics and event processor (DEEP). The RF module functions as frequency converters and mainly consists of local oscillators and I/Q mixers. The DEEP performs demultiplexing and event processing, and mainly consists of field-programmable gate arrays, ADCs, and DACs. We designed the RF electronics and DEEP to be flight ready, and estimated the power, size, and mass of those modules. There are two boxes each for the RF electronics and DEEP for segmentation, and the sizes of the boxes are 13 in: × 13 in: × 9 in: for the RF electronics and 15.5 in: × 11.5 in: × 9.5 in: for the DEEP. The estimated masses are 25.1 kg∕box for the RF electronics box and 24.1 kg∕box for the DEEP box. The maximum operating power for the RF electronics is 141 W or 70.5 W∕box, and for the DEEP box is 615 W or 308 W∕box. The overall power for those modules is 756 W. We describe the detail of the designs as well as the approaches to the estimation of resources, sizes, masses, and powers.

Sakai, Kazuhiro↗

Modulated-splitting-ratio fiber-optic temperature sensor

A fiber-optic temperature sensor is described, which uses a small silicon beamsplitter whose splitting ratio varies as a function of temperature. A four-beam technique is used to measure the sensor's temperature-indicating splitting ratio. This referencing method provides a measurement that is largely independent of the transmission properties of the sensor's optical fiber link. A significant advantage of this sensor, relative to other fiber-optic sensors, is its high stability, which permits the fiber-optic components to be readily substituted, thereby simplifying the sensor's installation and maintenance.

Beheim, Glenn↗

Modulated-splitting-ratio fiber-optic temperature sensor

A fiber-optic temperature sensor is described that uses a small silicon beamsplitter whose splitting ratio varies as a function of temperature. A four-beam technique is used to measure the sensor's temperature-indicating splitting ratio. This referencing method provides a measurement that is largely independent of the transmission properties of the sensor's optical fiber link. A significant advantage of this sensor, relative to other fiber-optic sensors, is its high stability, which permits the fiber-optic components to be readily substituted, thereby simplifying the sensor's installation and maintenance.

Beheim, Glenn↗

Electrolytes for Low Impedance, Wide Operating Temperature Range Lithium-Ion Battery Module

A lithium ion battery cell includes a housing, a cathode disposed within the housing, wherein the cathode comprises a cathode active material, an anode disposed within the housing, wherein the anode comprises an anode active material, and an electrolyte disposed within the housing and in contact with the cathode and anode. The electrolyte consists essentially of a solvent mixture, a lithium salt in a concentration ranging from approximately 1.0 molar (M) to approximately 1.6 M, and an additive mixture. The solvent mixture includes a cyclic carbonate, an non-cyclic carbonate, and a linear ester. The additive mixture consists essentially of lithium difluoro(oxalato)borate (LiDFOB) in an amount ranging from approximately 0.5 weight percent to approximately 2.0 weight percent based on the weight of the electrolyte, and vinylene carbonate (VC) in an amount ranging from approximately 0.5 weight percent to approximately 2.0 weight percent based on the weight of the electrolyte.

Hallac, Boutros↗

Development and testing of advanced fire-resistant photovoltaic modules

The evaluation of back-surface materials flammability in order to identify fire resistant module designs is examined. The fire test apparatus, burning-brand test sequence, and spread-of-flame test sequence are described. Video recordings and time-temperature profiles of module back surfaces are utilized to study the flammability failure mechanism and identify high-temperature materials. A table of flammability test results for various module designs is provided. The data reveals that 2-mil kapton, fiberglass cloth coated or impregnated with a material to plug pores, and metal foil back-surface materials achieve class A and B fire-resistance levels, and are applicable for photovoltaic module designs.

Sugimura, R. S.↗