A Fiber-Optic Coupled Telescope for Water Vapor DIAL Receivers

A fiber-optic coupled telescope of low complexity was constructed and tested. The major loss mechanisms of the optical system have been characterized. Light collected by the receiver mirror is focused onto an optical fiber, and the output of the fiber is filtered by an interference filter and then focused onto an APD detector. This system was used in lidar field measurements with a 532-nm Nd:YAG laser beam. The results were encouraging. A numerical model used for calculation of the expected return signal agreed with the lidar return signal obtained. The assembled system was easy to align and operate and weighed about 8 kg for a 30 cm (12") mirror system. This weight is low enough to allow mounting of the fiber-optic telescope receiver system in a UAV. Furthermore, the good agreement between the numerical lidar model and the performance of the actual receiver system, suggests that this model may be used for estimation of the performance of this and other lidar systems in the future. Such telescopes are relatively easy to construct and align. The fiber optic cable allows easy placement of the optical detector in any position. These telescope systems should find widespread use in aircraft and space home DIAL water vapor receiver systems.

DeYoung, Russell J.

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie

A New Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA (such as the Polstar MIDEX mission concept) call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that may produce extinction ratios higher than have ever been reported before in the FUV spectral range (100-200 nm). This polarizer consists of transmitting linearly polarized light through a series of reflections from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the LiF Brewster’s angle. The performance of this polarizer concept was fabricated and tested with an existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing has shown that in the FUV spectral range, this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm. A polarizer with such a performance has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the design’s compact design allows for a new polarizer capability that would one day be implemented in a future spectropolarimetry space mission. In addition, this polarizer concept could potentially be used to characterize the optical properties of new mirror coatings that will be used in a future Habitable World Observatory (HWO) mission concept as proposed by the 2020 Decadal Survey.2

Far Ultraviolet (FUV), polarimetry, instrumentatio

Linear Polarizer Design for Application in the Far-Ultraviolet Spectral Range

New mission concepts that are under consideration by NASA (such as the Polstar MIDEX mission concept) call for the design and implementation of Far Ultraviolet (FUV) polarizer technologies that have not been developed yet. A team that includes members from the NASA Goddard Space Flight Center (GSFC), Arizona State University (ASU), and Woodruff Consulting, worked on the design and development of a polarizer design that may produce extinction ratios higher than have ever been reported before in the FUV spectral range (100-200 nm). This polarizer consists of transmitting linearly polarized light through a series of reflections from a combination of two silicon carbide (SiC) and two lithium fluoride (LiF) crystals positioned at angles of incidence (relative to surface normal) close to the LiF Brewster’s angle. The performance of this polarizer concept was fabricated and tested with an existing McPherson 225 Vacuum Ultraviolet (VUV) spectrometer located in the Optics Branch at NASA-GSFC. Initial testing has shown that in the FUV spectral range, this design can produce state-of-the-art extinction ratios at the Hydrogen Lyman-Alpha (Ly-α) wavelength of 121.6 nm. A polarizer with such a performance has never been reported and it signifies a breakthrough in FUV polarization technology. The levels of effectiveness paired with the design’s compact design allows for a new polarizer capability that would one day be implemented in a future spectropolarimetry space mission. In addition, this polarizer concept could potentially be used to characterize the optical properties of new mirror coatings that will be used in a future Habitable World Observatory (HWO) mission concept as proposed by the 2020 Decadal Survey.2

Far Ultraviolet (FUV), polarimetry, instrumentatio

Softening the Gap between Wöhler and Paris – New Approaches for Fatigue Analysis –

Fatigue analysis tools can vary across industries. For example, automotive engineers often use the Wöhler (S-N) approach to design for safe-life, while aerospace engineers prioritize damage tolerance and inspection intervals, relying instead on crack growth models such as Paris’ law. Although both approaches may deal with the control of cracks in similar materials, their analysis tools and material characterizations are fundamentally distinct. This divide mirrors the classic split between stress-based strength analysis and linear elastic fracture mechanics. However, modern nonlinear models that incorporate material softening, such as cohesive laws, blur this boundary and capture fracture behaviors across scales. This presentation describes the CF23 fatigue model, which uses cohesive softening to link S-N crack initiation with crack propagation rates. CF23 spans the full fatigue spectrum, from initial propagation transients to steady-state growth and threshold conditions, offering a unified framework that bridges Wöhler and Paris-based methodologies. Example applications include fatigue crack propagation transients in adhesive interfaces and skin/stiffener separation.

cohesive elements

Thermal Analysis of the Advanced Technology Large Aperture Space Telescope (ATLAST) 8 Meter Primary Mirror

The Advanced Technology Large Aperture Space Telescope (ATLAST) preliminary design concept consists of an 8 meter diameter monolithic primary mirror enclosed in an insulated, optical tube with stray light baffles and a sunshade. ATLAST will be placed in orbit about the Sun-Earth L2 and will experience constant exposure to the sun. The insulation on the optical tube and sunshade serve to cold bias the telescope which helps to minimize thermal gradients. The primary mirror will be maintained at 280K with an active thermal control system. The geometric model of the primary mirror, optical tube, sun baffles, and sunshade was developed using Thermal Desktop(R) SINDA/FLUINT(R) was used for the thermal analysis and the radiation environment was analyzed using RADCAD(R). A XX node model was executed in order to characterize the static performance and thermal stability of the mirror during maneuvers. This is important because long exposure observations, such as extra-solar terrestrial planet finding and characterization, require a very stable observatory wave front. Steady state thermal analyses served to predict mirror temperatures for several different sun angles. Transient analyses were performed in order to predict thermal time constant of the primary mirror for a 20 degree slew or 30 degree roll maneuver. This paper describes the thermal model and provides details of the geometry, thermo-optical properties, and the environment which influences the thermal performance. All assumptions that were used in the analysis are also documented. Parametric analyses are summarized for design parameters including primary mirror coatings and sunshade configuration. Estimates of mirror heater power requirements are reported. The thermal model demonstrates results for the primary mirror heated from the back side and edges using a heater system with multiple independently controlled zones.

Hornsby, Linda

Characterization and Design of Digital Pointing Subsystem for Optical Communication Demonstrator

The Optical Communications Demonstrator (OCD) is a laboratory-based lasercom demonstration terminal designed to validate several key technologies, including beacon acquisition, high bandwidth tracking, precision bearn pointing, and point-ahead compensation functions. It has been under active development over the past few years. The instrument uses a CCD array detector for both spatial acquisition and high-bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field-of-view acquisition and permits effective platform jitter compensation and point-ahead control using only one steering mirror. This paper describes the detailed design and characterization of the digital control loop system which includes the Fast Steering Mirror (FSM), the CCD image tracker, and the associated electronics. The objective is to improve the overall system performance using laboratory measured data. The. design of the digital control loop is based on a linear time invariant open loop model. The closed loop performance is predicted using the theoretical model. With the digital filter programmed into the OCD control software, data is collected to verify the predictions. This paper presents the results of the, system modeling and performance analysis. It has been shown that measurement data closely matches theoretical predictions. An important part of the laser communication experiment is the ability of FSM to track the laser beacon within the. required tolerances. The pointing must be maintained to an accuracy that is much smaller than the transmit signal beamwidth. For an earth orbit distance, the system must be able to track the receiving station to within a few microradians. The failure. to do so will result in a severely degraded system performance.

Racho, C.

Feasibility of Exoplanet Coronagraphy with the Hubble Space Telescope

Herein we report on a preliminary study to assess the use of the Hubble Space Telescope (HST) for the direct detection and spectroscopic characterization of exoplanets and debris disks - an application for which HST was not originally designed. Coronagraphic advances may enable the design of a science instrument that could achieve limiting contrasts approx.10deg beyond 275 milli-arcseconds (4 lambda/D at 800 nm) inner working angle, thereby enabling detection and characterization of several known jovian planets and imaging of debris disks. Advantages of using HST are that it already exists in orbit, it's primary mirror is thermally stable and it is the most characterized space telescope yet flown. However there is drift of the HST telescope, likely due to thermal effects crossing the terminator. The drift, however, is well characterized and consists of a larger deterministic components and a smaller stochastic component. It is the effect of this drift versus the sensing and control bandwidth of the instrument that would likely limit HST coronagraphic performance. Herein we discuss the science case, quantifY the limiting factors and assess the feasibility of using HST for exoplanet discovery using a hypothetical new instrument. Keywords: Hubble Space Telescope, coronagraphy, exoplanets, telescopes

Lyon, Richard G.

A technique for the optical analysis of deformed telescope mirrors

The NASTRAN-ACCOS V programs' interface merges structural and optical analysis capabilities in order to characterize the performance of the NASA Goddard Space Flight Center's Solar Optical Telescope primary mirror, which has a large diameter/thickness ratio. The first step in the optical analysis is to use NASTRAN's FEM to model the primary mirror, simulating any distortions due to gravitation, thermal gradients, and coefficient of thermal expansion nonuniformities. NASTRAN outputs are then converted into an ACCOS V-acceptable form; ACCOS V generates the deformed optical surface on the basis of these inputs, and imaging qualities can be determined.

Bolton, John F.

Improvement in Suppression of Pulsed Nd:YAG Laser Light With Iodine Absorption Cells for Filtered Rayleigh Scattering Measurements

Filtered Rayleigh scattering using iodine absorption cells is an effective technique for obtaining density, temperature, and velocity measurements in high speed confined flows. By tuning a single frequency laser to a strong iodine absorption line, stray scattered laser light can be greatly suppressed. For example, the minimum transmission predicted by an iodine absorption model calculation is less than 10(exp -5) at the 18788.44/cm line using a 200 mm absorption cell containing iodine vapor at 0.46 T. Measurements obtained by other researches using a CW Nd:YAG laser agree with the model calculations. However, measurements made by us and by others using Q-switched, injection-seeded, frequency doubled Nd:YAG lasers only show minimum transmission of about 3 x 10(exp -3). This greatly reduces the applicability of the filtered Rayleigh scattering technique using these lasers in experiments having large amounts of stray scattered laser light. The purposes of the present study are to characterize the spectrum of the excess light transmitted by the iodine cell and to make changes to the laser to reduce the transmitted laser light. Transmission data as a function of laser frequency for the iodine absorption line at 18788.44/cm are presented. A planar mirror Fabry-Perot interferometer was used to characterize the frequency spectrum of the light passed through the cell. Measurements taken with the laser tuned to the center of the iodine absorption line show the light transmitted through the iodine cell to have a component with a bandwidth of about 40 GHz. This is probably caused by other modes in the laser that exist in spite of the single frequency injection beam. A second broadband component was also observed, possibly caused by the laser flash lamps or by fluorescence. An intracavity etalon was installed in the laser oscillator cavity to suppress the 40 GHz component. Measurements taken with the etalon tuned to the injection frequency showed a reduction in the transmitted laser light. This improvement allows the iodine cell to block significantly more of the stray laser light in filtered Rayleigh scattering experiments. Examples are given of filtered Rayleigh scattering measurements showing the effect of the etalon on measurements taken in a Mach 3 flow in the NASA Lewis 4 inch by 10 inch supersonic wind tunnel.

Seasholtz, Richard G.

SUMMA hot-ion plasma heating research at NASA Lewis Research Center

This report describes the SUMMA superconducting magnetic mirror facility at the NASA Lewis Research Center and the hot-ion plasma research conducted therein. SUMMA is characterized by intense magnetic fields (designed for 8.6 T at the mirrors) and a large-diameter working bore (41 cm diameter) with room-temperature access. The goal of the plasma research program is to produce steady-state plasmas of fusion reactor densities and temperatures (but not confinement times). The program includes electrode development to produce a hot, dense, large-volume, steady-state plasma and diagnostics development to document the plasma properties. SUMMA and its hot-ion plasma are ideally suited to develop advanced plasma diagnostics methods. Two such methods whose requirements are well matched to SUMMA are: (1) heavy ion beam probing to measure plasma space potential, and (2) submillimeter wavelength laser Thomson scattering to measure local ion temperature. Two NASA University Grants were established to identify major requirements for developing these two diagnostic techniques in SUMMA.

Reinmann, J. J.

Zernike-like Orthogonal Basis Functions for Wavefront Characterization over Sampled, Irregular Apertures

For optical systems with circular apertures, wavefronts are often analyzed using Zernike polynomials, and individual Zernike functions are associated with familiar optical aberrations. For systems with noncircular apertures, or in practical situations in which wavefronts are measured at a limited number of points in the aperture, the Zernike polynomials are no longer an orthogonal basis for the measured data. Although there are an endless number of ways to create a basis for such measured data, a "Zernike-like" basis is useful to connect with our experience with the usual optical aberrations. In this paper, the steps required to identify a Zernike-like basis for wavefronts over sampled, irregular apertures are presented, based on the Gram-Schmidt orthogonalization technique. The benefits of analyzing optical wavefronts using an orthogonal basis specific to an optical system's aperture shape and wavefront sampling, instead of using the traditional Zernike polynomials, are detailed in two examples, from image-based wavefront sensing on a segmented-aperture telescope (the James Webb Space Telescope Testbed Telescope at Ball Aerospace) and from interferometer characterization for surface metrology of a hexagonal mirror segment.

Aronstein, David L.

Properties of a Variable-Delay Polarization Modulator

We investigate the polarization modulation properties of a variable-delay polarization modulator (VPM). The VPM modulates polarization via a variable separation between a polarizing grid and a parallel mirror. We find that in the limit where the wavelength is much larger than the diameter of the metal wires that comprise the grid, the phase delay derived from the geometric separation between the mirror and the grid is sufficient to characterize the device. However, outside of this range, additional parameters describing the polarizing grid geometry must be included to fully characterize the modulator response. In this paper, we report test results of a VPM at wavelengths of 350 micron and 3 mm. Electromagnetic simulations of wire grid polarizers were performed and are summarized using a simple circuit model that incorporates the loss and polarization properties of the device.

Chuss, David T.

JWST Optical Telescope Element Center of Curvature Test

The James Webb Space Telescope (JWST) Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) completed element level integration and test programs and were integrated to the next level of assembly called OTE/ISIM (OTIS) at Goddard Space Flight Center (GSFC) in Greenbelt, Maryland in 2016. Before shipping the OTIS to Johnson Space Center (JSC) for optical test at cryogenic temperature a series of vibration and acoustic tests were performed. To help ensure that the OTIS was ready to be shipped to JSC an optical center of curvature (CoC) test was performed to measure changes in the mirror's optical performance to verify that the telescope's primary mirror was not adversely impacted by the environmental testing and help us in understanding potential anomalies identified during the JSC tests. The primary is a 6.5 meter diameter mirror consisting of 18 individual hexagonal segments. Each segment is an off-axis asphere. There are a total of three prescriptions repeated six times each. As part of the CoC test each segment was individually measured using a high-speed interferometer (HSI) designed and built specifically for this test. This interferometer is capable of characterizing both static and dynamic characteristics of the mirrors. The latter capability was used, with the aid of a vibration stinger applying a low-level input force, to measure the dynamic characteristic changes of the PM backplane structure. This paper describes the CoC test setup and both static and dynamic test results.

interferometer

Assessment of MODIS On-orbit Polarization Impact on Detector Relative Calibration

The Moderate-Resolution Imaging Spectroradiometer (MODIS) has been maintained its nominal operations since it was launched in December 1999 on Terra and May 2002 on Aqua spacecraft, respectively. MODIS is a scanning radiometer with a two-sided mirror that scans the Earth over an angular range from -55° to +55° off nadir and covers a wavelength range from 0.4 to 14.4 μm in 36 spectral bands. The sensitivity to polarization was fully characterized during prelaunch characterization for each reflective solar band (RSB), detector and mirror side as a function of scan angle. It was observed that while on-orbit polarization sensitivity for Aqua MODIS has been stable over the course of mission, the Terra MODIS polarization sensitivity at a few short wavelengths showed a significant increase near the end of scan angle after a few years in the mission. Our previous study examined the impact of polarization on the measured top-of-atmosphere reflectances obtained over the pseudo-invariant desert sites. There are up to 25% change in gain and 30% seasonal variation in select Terra RSBs due to the increase in polarization sensitivity. In this study, we examine relative changes in the polarization sensitivity of detectors within a band. Results from prelaunch tests indicate that there is a noticeable detector dependent polarization sensitivity and it is expected that such a dependency could change on orbit, particularly for Terra MODIS. Results of this study provide useful information on polarization impact and implementation of the correction algorithm.

MODIS

Materials and structures

Materials and structures technology covers a wide range of technical areas. Some of the most pertinent issues for the Astrotech 21 missions include dimensionally stable structural materials, advanced composites, dielectric coatings, optical metallic coatings for low scattered light applications, low scattered light surfaces, deployable and inflatable structures (including optical), support structures in 0-g and 1-g environments, cryogenic optics, optical blacks, contamination hardened surfaces, radiation hardened glasses and crystals, mono-metallic telescopes and instruments, and materials characterization. Some specific examples include low coefficients of thermal expansion (CTE) structures (0.01 ppm/K), lightweight thermally stable mirror materials, thermally stable optical assemblies, high reliability/accuracy (1 micron) deployable structures, and characterization of nanometer level behavior of materials/structures for interferometry concepts. Large filled-aperture concepts will require materials with CTE's of 10(exp 9) at 80 K, anti-contamination coatings, deployable and erectable structures, composite materials with CTE's less than 0.01 ppm/K and thermal hysteresis, 0.001 ppm/K. Gravitational detection systems such as LAGOS will require rigid/deployable structures, dimensionally stable components, lightweight materials with low conductivity, and high stability optics. The Materials and Structures panel addressed these issues and the relevance of the Astrotech 21 mission requirements by dividing materials and structures technology into five categories. These categories, the necessary development, and applicable mission/program development phasing are summarized. For each of these areas, technology assessments were made and development plans were defined.

Saito, Theodore T.

First Generation Parabolic Deformable Mirror for the ExoSpec Project

The Exoplanet Spectroscopy (ExoSpec) project links four different tasks at Goddard Space Flight Center (GSFC) to facilitate efficient imaging and characterization of exoplanets. One of the tasks is the development of parabolic deformable mirrors to improve on the current state-of-the-art wavefront sensing and control implementations that are baselined to have two high-actuator count flat deformable mirrors (DMs). The current baseline has two DMs at a considerable separation distance to effectively control both amplitude and phase aberrations. This significant separation poses packaging challenges to the direct imaging missions. We can mitigate this issue by making the off-axis imaging elements in the optical train controllable. Besides addressing the packaging challenges, this technique reduces the risk of having the entire coronagraph instrument’s performance depend on two high-actuator count DMs. Simulations show that making imaging elements deformable increases the overall controllable bandwidth - it would be possible to control wavefront aberrations up to 35% bandwidth over a 5 - 12 λ/D. GSFC has worked with a commercial vendor to produce a first-generation parabolic DM and built a testbed in an environmentally controlled cleanroom to experimentally demonstrate the use of a parabolic DM in a coronagraph instrument. This versatile testbed is designed to test different DM architectures and various low-order wavefront schemes. This provides us with a basis for comparison with different DM configurations —1) flat DM, 2) parabolic DMs, and 3) flat DM and parabolic DMs. In this paper, we will provide an update on our parabolic DM work.

Deformable Mirror