Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “microtomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Evolution of Defect Properties and Texture During Tensile Deformation of Additively Manufactured 316L Stainless Steel Using In-situ Synchrotron X-ray Computed Microtomography and Diffraction

The ability of Additive Manufacturing to create complex 3D objects has attracted the attention of a wide variety of industries [1]. This in turn has led to detailed studies investigating the relationship between AM processing parameters and final part characteristics such as porosity and texture [2]. However little research has been done to study the effects of these subsequent characteristics on these parts’ performance [3]. In this study, 316L stainless steel samples were additively manufactured to have common AM defects. The samples were deformed plasticly while undergoing in-situ microtomography and diffraction measurements.

36 MATERIALS SCIENCE↗

Quantitative and qualitative bone imaging: A review of synchrotron radiation microtomography analysis in bone research

All levels of the unique hierarchical structure of bone, consisting of collagen and hydroxyapatite crystals at the nanoscale to osteon/lamellae structures at the microscale, contribute to its characteristic toughness and material properties. Elements of bone's density and size contribute to bone quantity (or bone mass), whereas elements of bone's material composition, material properties, internal structure, and organization describe bone quality. Furthermore, bone quantity and quality can be degraded by factors such as aging, disease, treatments, and irradiation, compromising its ability to resist fracture and sustain loading. Accessing the morphology and architecture of bone at the microscale to quantify microstructural features and assess the degree of mineralization and path of crack propagation in bone provides crucial information on how these factors are influencing bone quantity and quality. Synchrotron radiation micro-computed tomography (SRμCT) was first used to assess bone structure at the end of the 1990's. One of the main advantages of the technique is that it enables accurate three-dimensional (3D), non-destructive quantification of structure while traditional histomorphometry on histological sections is inherantly destructive to the sample and two-dimensional (2D). Additionally, SRμCT uses monochromatic, high-flux X-ray beams to provide high-resolution and high-contrast imaging of bone samples. This allows the quantification of small microstructural features (e.g. osteocyte lacunae, canals, trabeculae, microcracks) and direct gray value compositional mapping (e.g. mineral quantification, cement lines) with greater speed and fidelity than lab-based micro-computed tomography. In this article, we review how SRμCT has been applied to bone research to elucidate the mechanisms by which bone aging, disease, and other factors affect bone fragility and resistance to fracture.

60 APPLIED LIFE SCIENCES↗

Density measurement of samples under high pressure using synchrotron microtomography and diamond anvil cell techniques

Accurate mass density information is critical in high-pressure studies of materials. It is, however, very difficult to measure the mass densities of amorphous materials under high pressure with a diamond anvil cell (DAC). Employing tomography to measure mass density of amorphous samples under high pressure in a DAC has recently been reported. In reality, the tomography data of a sample in a DAC suffers from not only noise but also from the missing angle problem owing to the geometry of the DAC. An algorithm that can suppress noise and overcome the missing angle problem has been developed to obtain accurate mass density information from such ill-posed data. The validity of the proposed methods was supported with simulations.

47 OTHER INSTRUMENTATION↗

Mjölnir: a miniature triaxial rock deformation apparatus for 4D synchrotron X-ray microtomography

An X-ray transparent experimental triaxial rock deformation apparatus, here named 'Mjölnir', enables investigations of brittle-style rock deformation and failure, as well as coupled thermal, chemical and mechanical processes relevant to a range of Earth subsurface environments. Designed to operate with cylindrical samples up to 3.2 mm outside-diameter and up to 10 mm length, Mjölnir can attain up to 50 MPa confining pressure and in excess of 600 MPa axial load. The addition of heaters extends the experimental range to temperatures up to 140°C. Deployment of Mjolnir on synchrotron beamlines indicates that full 3D datasets may be acquired in a few seconds to a few minutes, meaning full 4D investigations of deformation processes can be undertaken. Mjölnir is constructed from readily available materials and components and complete technical drawings are included in the supporting information.

47 OTHER INSTRUMENTATION↗

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗

Image analysis algorithms for estimating porous media multiphase flow variables from computed microtomography data: a validation study

Image analysis of three-dimensional microtomographic image data has become an integral component of pore scale investigations of multiphase flow through porous media. This study focuses on the validation of image analysis algorithms for identifying phases and estimating porosity, saturation, solid surface area, and interfacial area between fluid phases from gray-scale X-ray microtomographic image data. The data used in this study consisted of (1) a two-phase high precision bead pack from which porosity and solid surface area estimates were obtained and (2) three-phase cylindrical capillary tubes of three different radii, each containing an air-water interface, from which interfacial area was estimated. The image analysis algorithm employed here combines an anisotropic diffusion filter to remove noise from the original gray-scale image data, a k-means cluster analysis to obtain segmented data, and the construction of isosurfaces to estimate solid surface area and interfacial area. Our method was compared with laboratory measurements, as well as estimates obtained from a number of other image analysis algorithms presented in the literature. Porosity estimates for the two-phase bead pack were within 1.5% error of laboratory measurements and agreed well with estimates obtained using an indicator kriging segmentation algorithm. Additionally, our method estimated the solid surface area of the high precision beads within 10% of the laboratory measurements, whereas solid surface area estimates obtained from voxel counting and two-point correlation functions overestimated the surface area by 20--40%. Interfacial area estimates for the air-water menisci contained within the capillary tubes were obtained using our image analysis algorithm, and using other image analysis algorithms, including voxel counting, two-point correlation functions, and the porous media marching cubes. Our image analysis algorithm, and other algorithms based on marching cubes, resulted in errors ranging from 1% to 20% of the analytical interfacial area estimates, whereas voxel counting and two-point correlation functions overestimated the analytical interfacial area by 20--40%. In addition, the sensitivity of the image analysis algorithms on the resolution of the microtomographic image data was investigated, and the results indicated that there was little or no improvement in the comparison with laboratory estimates for the resolutions and conditions tested.

58 GEOSCIENCES↗

Synchrotron Radiation Microtomography for Large Area 3D Imaging of Multilevel Microelectronic Packages

3D x-ray computed tomography (CT), using conventional laboratory-based x-ray sources, has been used in the past to image multiple levels of interconnects in 3D microelectronic packages. These conventional x-ray sources can provide high resolution images with throughput times (TPT) of several hours. However, this can only be performed on localized areas of about 1–2 mm 2 , which gravely limits the application of 3D x-ray CT in the field of microelectronic packages with sizes usually in the range of 100–3600 mm 2 . An alternative to laboratory-based x-ray sources is synchrotron radiation, which can produce large area collimated beams for high flux x-ray imaging over a much larger field of view (FOV) than conventional sources. Synchrotrons can potentially image an entire 3D stacked chip package at high resolutions in less than an hour. Here, we present results using the micro-CT line at the advanced light source synchrotron to image an entire 16 × 16 mm system in a package in times as low as 3 min, demonstrating several orders of magnitude increase in the ratio of FOV to TPT as compared to laboratory-based x-ray methods.

42 ENGINEERING↗

In Situ X-ray Microtomography of Stress Corrosion Cracking and Corrosion Fatigue in Aluminum Alloys

Structural materials are subjected to combinations of stress and corrosive environments that work synergistically to cause premature failure. Therefore, studies on the combined effect of stress and corrosive environments on material behavior are required. Existing studies have been performed in two dimensions that are inadequate for full comprehension of the three-dimensional (3D) processes related to stress corrosion cracking (SCC) and corrosion-fatigue (CF) behavior. Recently, x-ray synchrotron tomography has evolved as an excellent technique to obtain the microstructure in 3D. Moreover, being nondestructive in nature, x-ray synchrotron tomography is well suited to study the evolution of microstructure with time (4D, or fourth dimension in time). Furthermore, this article presents our recent 4D studies on SCC and CF of Al 7075 alloys using x-ray synchrotron tomography.

36 MATERIALS SCIENCE↗