Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility’s historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Quantitative Evaluation of Reliability Improvement: Case Study on a Self-healing Distribution System

In this work, we develop a methodology and tool to quantitatively evaluate the reliability of a self-healing system that considers practical distribution system features such as the distributed energy resources, microgrids, and service restoration strategies. Also, this paper addresses various practical issues when being applied to an actual Duke Energy distribution system, including the design of feasible and practical service restoration strategies that are used to identify the customer interruptions after a fault, and the incorporation of the utility's historical reliability indices that are used to calibrate the failure rate and repair time of distribution system components such as overhead lines and underground cables. This case study demonstrates the effectiveness of the proposed method.

Dong, Jiaojiao↗

Ensuring Transient Stability With Guaranteed Region of Attraction in DC Microgrids

DC microgrids have promising applications in renewable integration due to their better energy efficiency when connecting DC components. However, they might be unstable since many loads in a DC microgrid are regulated as constant power loads (CPLs) that have a destabilizing negative impedance effect. As a result, the state trajectory displacement caused by abrupt load changes or contingencies can easily lead to instability. Many existing works have been devoted to studying the region of attraction (ROA) of a DC microgrid, in which the system is guaranteed to be asymptotically stable. Nevertheless, existing work either focuses on using numerical methods for ROA approximations that generally have no performance guarantees or cannot ensure a desired ROA for a general DC microgrid. To close this gap, this paper develops an innovative control synthesis algorithm to make a general DC microgrid have a theoretically guaranteed ROA, for example, to cover the entirety of its operating range regarding state trajectories. Here, we first study the nonlinear dynamics of a DC microgrid to derive a novel transient stability condition to rigorously certify whether a given operating range is a subset of the ROA; then, we formulate a control synthesis optimization problem to guarantee the condition’s satisfaction. This condition is a linear constraint, and the optimization problem resembles an optimal power flow problem and has a good computational behavior. Simulation case studies verify the validity of the proposed work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Fast Charging Station (MFCS) Design Platform Project (Summary Report)

This report documents the important steps and outcomes of the Microgrid Fast Charging Station (MFCS) Design Platform project, executed by XENDEE Corporation and its testing and validation by Idaho National Laboratory (INL). This final summary report builds on the first summary released on April 30th, 2021 and adds the final results from the Hardware in the Loop (HIL) simulations and tests, which have been completed July 14th 2021. With this report XENDEE Corporation and Idaho National Laboratory conclude the first version of the Microgrid Fast Charging Station (MFCS) Design Platform as well as all related tests and validations for two in-depth case studies for islanded and non-islanded operation. The platform itself utilizes XENDEE’s advanced modeling systems and INL’s HIL system to ensure project viability and technical feasibility. It also intelligently maps all cables, transformers, and distributed technology interactions to anticipate and mitigate problems during peak usage or adverse conditions. Finally, the system is designed to optimize dispatch and generation at each time step of the day allowing the Microgrid to take advantage of energy sales to the utility and best manage the charging of an electrical fleet. This allows operators to reliably build bankable Microgrid systems and to operate them to reach the maximum efficiency even under the dynamic needs of electric vehicle fast charging

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Hardening Design Toolkit: Puerto Rico Use Case

This document provides a comprehensive example of the microgrid hardening framework and the Sandia developed Microgrid Hardening Design Toolkit v0.27 using a census tract in a coastal area of southern Puerto Rico as a case study. The census tract (72123953100) is located in the municipality of Salinas. Currently, the La Margarita neighborhood within this census tract is part of the Department of Energy’s Cohort 5 of the Energy Technology Innovation and Partnership Program (ETIPP). The neighborhood’s local energy cooperative, Abeyno Coop, has been operating several residential solar photovoltaic (PV) and battery energy storage system (BESS) installations (with around 30 rooftop solar systems as of 2026). As part of the ETIPP project, Abeyno Coop is planning to integrate a larger microgrid into the existing distribution feeder in the area, including solar PV and BESS to supply energy for homes and critical loads such as the medical facilities and the community center that provides emergency shelter and backup power during outages.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Networked Microgrid Energy Management Considering Ownership and Control Structures: A Comparison

With the growing deployment of microgrids, networked microgrids have emerged for their additional advantages of economy, reliability and resilience by coordinating the operation of multiple microgrids. As microgrids are operated with different ownership, objectives and functionalities, the formed networked microgrids show characteristics of mixed ownership, inconsistent objectives and various functionalities. To enable the coordinated operation of networked microgrids, three control structures, i.e., centralized, distributed and decentralized, have been constructed in the literature. However, the data sharing enabling these different paradigms and the resulted value propositions are not well defined, leading to poor resource management and resilience, etc. To solve this issue, a complete comparison of networked microgrid energy management under centralized, distributed and decentralized structures are performed. As a novel contribution, the required minimum data exchange of networked microgrid energy management under three control structures are identified, respectively. The value propositions are calculated and compared against each other by the results of case studies.

control structures↗

Analytical Large-Signal Modeling of Inverter-Based Microgrids With Koopman Operator Theory for Autonomous Control

The microgrid (MG) plays a crucial role in the energy transition, but its nonlinearity presents a significant challenge for large-signal power systems studies in the electromagnetic transient (EMT) time scale. In this paper, we develop a large-signal linear MG model that considers the detailed dynamics of the primary and zero-control levels based on the Koopman operator (KO) theory. Firstly, a set of observable functions is carefully designed to capture the nonlinear dynamics of the MG. The corresponding linear KO is then analytically derived based on these observables, resulting in the linear representation of the original nonlinear MG with observables as the new coordinate. The influence of external input on the system dynamics is also considered during the derivation, enabling control of the MG. We solve the voltage control problem using the traditional linear quadratic integrator (LQI) method to demonstrate that textbook linear control techniques can accurately control the original nonlinear MG via the developed KO-linearized MG model. Our proposed KO linearization method is generic and can be easily extended for different control objectives and MG structures using our analytical derivation procedure. Here, we validate the effectiveness of our methodology through various case studies.

25 ENERGY STORAGE↗

FY2021 Isolated Grids and Grid-Connected Turbine Reference Systems

For individuals, businesses, and communities focused on building resilient electrical grid infrastructure, wind energy can provide an affordable, accessible, and compatible distributed energy resource option that also enhances the capabilities of local grid operations. However, there are technical barriers to realizing the market value and resilience benefits of distributed wind, and there is little to no ability to quantify those benefits so that stakeholders can compare grid investment options. The central aims of this report are: (1) to drive technology transfer of the methods and technologies developed under the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) project and (2) increase the number of referenceable case studies available to stakeholders interested in additional value-added capabilities of wind systems beyond bulk energy supply. We achieve this aim by applying three major methods developed under MIRACL to two real-world distributed wind reference systems. The two real-world distributed wind reference systems are the isolated grid of St. Mary’s, Alaska, and the two 10.5-megawatt (MW) front-of-the-meter wind turbine deployments owned and operated by Iowa Lakes Electric Cooperative (ILEC).

17 WIND ENERGY↗

Evaluating the resilience benefits of marine energy in microgrids

Marine energy resources could promote clean energy and resilience of coastal and island microgrids, and thus, these applications are a key future market for marine energy development. To demonstrate these benefits, this paper illustrates how inclusion of wave resources into energy resilience solutions can improve overall grid efficiency and sustainability, as well as maintain electricity supply during grid outages. The paper describes a case study evaluation of the potential to add wave energy to the Moloka’i grid as Hawaii strives to meet a 100% clean energy target. The Microgrid Component Optimization for Resilience tool is used to simulate operation in off- grid conditions and size different combinations of wave, solar photovoltaic (PV), wind, storage, and fuel resources required to meet resilience objectives. This research in- vestigates how including wave resources in a microgrid contributes to reducing biofuel generation, producing a zero-greenhouse gas emission profile, and avoiding the over-sizing of PV and battery systems to accommodate periods of unavailability or high demand. Insight from this paper supports the value proposition of wave resources for future markets and informs the relationship between marine generators and microgrids or isolated grids.

Newman, Sarah F.↗

Energy-Storage Fed Smart Inverters for Mitigation of Voltage Fluctuations in Islanded Microgrids

The continuous integration of intermittent low-carbon energy resources makes islanded microgrids vulnerable to voltage fluctuations. Besides, different dynamic response of synchronous-based and inverter-based distributed generation (DG) units can result in an instantaneous power imbalance between supply and demand during transients. As a result, the ac-bus voltage of microgrid starts oscillating which might have severe consequences such as blackouts. This paper modifies the conventional control scheme of battery energy storage systems (BESSs) to participate in improving the dynamic behavior of islanded microgrids by mitigating the voltage fluctuations. A piecewise linear-elliptic (PLE) droop is proposed and employed in BESS to achieve an enhanced voltage profile by injecting/absorbing reactive power during transients. In this way, the conventional inverter implemented in BESS turns into a smart inverter to cope with fast transients. Using the proposed approach in this paper, any linear droop curve with a specified coefficient can be replaced by a PLE droop curve. Compared with linear droop, an enhanced dynamic response is achieved by utilizing the proposed PLE droop. Case study results are presented using PSCAD/EMTDC to demonstrate the superiority of the proposed approach in improving the dynamic behavior of islanded microgrids.

Pilehvar, Mohsen S.↗

Mathematical Models for Optimization of Grid-Integrated Energy Storage Systems

Energy storage has been proven to yield positive effects on planning, operation and control of electric grids. It has become a crucial task to properly model the energy storage systems (ESS) under the framework of grid optimization on transmission and distribution networks including microgrids. This paper presents a review on mathematical models and test cases of ESSs used for grid optimization studies, where the network constraints of power systems are included. The existing ESS models are mainly classified into two categories – linear and nonlinear models. The two main categories are further divided into several subcategories respectively; such as mixed-integer linear and convex nonlinear sub-categories. Based on the review and discussions, this paper aims at providing suggestions for choosing proper ESS models for specific grid optimization studies considering the chosen power network model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydropower Evaluation Framework for Wildfire Resilient Microgrids

This paper presents a framework for characterizing hydropower plants based on plant and site attributes, assessing their feasibility to function within microgrids during periods of wildfire-induced outages. A set of nine metrics is developed to assign scores to hydropower plants, considering their suitability for forming wildfire-resilient microgrids, their capability to operate within such microgrids, and their simulated performance during wildfire events. A comprehensive database is constructed, comparing hydropower plants according to their suitability and capability metrics. To evaluate the performance score of a specific hydropower plant, namely the Hills Creek plant situated in a wildfire-prone region of Oregon, a case study is conducted, simulating a wildfire scenario. The results of steady-state and dynamic simulations demonstrate that the Hills Creek hydropower plant can effectively provide crucial microgrid services and power nearby communities during a prolonged wildfire-related outages.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Community-Centric Microgrid Feasibility Analysis Framework to Accelerate Resilience of Island Communities

Marine energy offers a reliable energy solution for island and coastal communities, which often lack traditional local generation, to support their transition to energy independence and reduce reliance on externally imported fuels. Successful deployment of new technologies in these isolated locations requires community acceptance and approval from the outset, as these communities typically lack the financial and technical resources to operate and maintain new systems. This report presents a community-centric microgrid planning framework for remote coastal and island communities. Community engagement is integrated as the first step in the planning process, incorporating community profiles and visions into energy development scenarios. A case study was conducted in St. George, Pribilof Islands, Alaska, which relies entirely on diesel yet has significant wind and wave energy potential. Community engagement revealed a unique history and current economic status, with an interest in adopting advanced energy technologies despite past failures. Various microgrid configurations were optimized, considering different technologies to meet current and future energy needs while balancing cost and energy resilience. Wave energy converters (WECs) were a key component, integrated with other energy sources using the Xendee optimization tool. The Marine Energy Microgrid Toolkit, developed as part of this work, uses commercial power system analysis tools to optimize and analyze microgrid scenarios. The developed framework and toolkit can be applied to island and coastal communities to enhance resilience and support microgrid deployments. Future enhancements will include incorporating new marine resources, developing dynamic models, and automating the integration of Xendee and PowerFactory simulations.

02 PETROLEUM↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Integrating Resilience Planning in Distribution System Planning

Electric utilities, regulators, and stakeholders face increasing risks of severe storms, freezes, floods, and heat waves damaging grid infrastructure and causing power outages—and increasing risks of utility equipment igniting wildfires. At the same time, customer electricity rates have risen substantially in recent years, due in part to replacing aging infrastructure and improving resilience to natural hazards and physical threats. To address these challenges, utilities are beginning to move beyond traditional, siloed planning processes to balance resilience with other fundamental grid objectives such as affordability, reliability, safety, and serving new loads. This study presents a framework for states and utilities that want to advance integration of resilience and distribution planning processes to improve planning efficiency, better prioritize cost-effective grid expenditures, and balance planning objectives. The framework includes 7 key integration points between these planning processes: -Strategy process -Data -Threat assessments -Solution identification and prioritization -Optimization opportunities -Consideration of other grid needs -Metrics Lawrence Berkeley National Laboratory reviewed utility distribution system plans and interviewed subject matter experts to identify emerging practices for each of the 7 integration points. This report presents these practices, which can be used as a guide toward more holistic planning and cohesive investment strategies. It also includes 3 case studies to provide practical examples of how utilities apply such integrated planning processes: two pole hardening programs and one microgrid planning effort. The report concludes by identifying opportunities for future research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗

SVM-Based Synchronized Fault Detection for 100% Renewable Microgrids: Preprint

Traditional protection schemes face significant challenges when applied to microgrids with high penetrations of renewables with inverter-based resources (IBRs). The proliferation of advanced sensing and communication technologies has generated copious data, offering an opportunity to overcome these limitations using data-driven machine learning approaches. This work proposes a novel approach based on a support vector machine (SVM) for detecting faults within a 100% renewable microgrid. The approach encompasses a systematic offline training stage for the development of a linear SVM-based fault detection algorithm. This process covers offline data collection from the microgrid under study, the extraction of features such as positive- and negative-sequence components and the total harmonic distortion of the voltage and current measurements of the relays, and the design of the linear SVM-based classifier. During the online implementation, however, different classifiers can exhibit asynchronicity in detecting the fault inception at different subcycle-to-cycle period-level delays. To circumvent this asynchronicity issue, a separate algorithm is developed for each relay to estimate the fault inception time as close to the real fault time. The performance of the proposed SVM-based synchronized fault detection method is evaluated using online time-domain simulation studies on a microgrid test system. The results corroborate the reliability of the fault detection scheme when tested under various fault cases (fault types, locations, and impedances) and non-fault cases during both grid-tied and islanded operation modes.

100% microgrid↗