Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “methods: analytical methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Using Best Basis Inventory Data to Direct Strategies for Real Time Monitoring of Hanford High Level Waste – 26226

The potential to accelerate the processing of low- and high-level tank waste by applying real-time monitoring (RTM) of chemical and physical properties has prompted research into the suitability of multiple analytical methods for that purpose. The broad variety of waste stream properties and the large number of analytes of interest (as evidenced by Waste Acceptance Criteria (WAC) and Process Control Limit (PCL) lists) lead to an overwhelming set of possible analytical scenarios. This report describes the use of Best Basis Inventory (BBI) data to find the most relevant analytical targets for the specific case of monitoring the blending of High Level Waste from multiple tanks prior to introduction into a vitrification facility. Campaigns for blending this waste to minimize the risk of exceeding WACs and PCLs have been proposed. However, the predicted compositions of the blended materials do not incorporate any uncertainties that may be associated with the representativeness of the waste layer samples or the laboratory analyses that generated the BBI data. Also, they do not include any uncertainty associated with the precision of collecting highly specific fractions of the layers during a blending campaign or any inhomogeneities that may exist in those layers. Monte Carlo methods are used to apply uncertainties to the compositions of the individual layers specified in the campaign recipes. The resulting variations in the compositions of the blended materials allow estimation of the risks of exceeding WACs and PCLs for each campaign. A critical subset of WACs/PCLs – NOx, NaK, AlFeZr, and S – are especially at risk of being exceeded in multiple campaigns. These analytes should be the focus of instrument development. We also have extracted the expected solid/supernate distribution for these analytes, which establishes important performance criteria for individual analytical methods. The BBI data also permits an understanding of the different chemical forms in which the analytes appear. Thus, the need to establish instrumental sensitivity to these forms can be gainfully addressed. Although concentrating on one specific application – the blending of tank waste - this approach should be generalizable for the analysis of other possible RTM applications for waste processing.

Lascola, Robert [Savannah River National Laborator↗

Advanced Method Optimization with Categorical and Constrained Continuous Parameters

Traditional approaches to analytical method optimization (e.g., univariate and “guess-and-check”) can be time-consuming, costly, and often fail to identify true optima within the parameter space. Previous work defined and implemented a generalized technique for method optimization for continuous method parameters, but a knowledge gap remains for the incorporation of categorical variables into these advanced method optimization schemes. This work presents and validates a generalized optimization approach that incorporates both continuous and categorical variables while also utilizing a multivariate, multiobjective optimization scheme with Karush–Kuhn–Tucker conditions to bound the optimization space to solutions within the physical limitations of the parameter space. Method optimization from a case study using GC–MS for the analysis of 11 analytical standards with objectives to minimize peak width and maximize peak height resulted in a 3 orders of magnitude improvement in the average peak height and a 2 orders of magnitude improvement in the average peak width compared to the least optimal (but reasonable) instrumental parameters utilized in this study. This approach to optimization allows for a customizable method optimization in which users can include both continuous and categorical variables to achieve objectives specific to their analytical goals. This approach significantly reduces the labor and cost associated with traditional method development approaches and can be applied in a variety of scientific fields across a range of laboratory techniques (e.g., instrument method development, sample preparation, and extraction techniques).

Amorphous materials↗

Detection of anaerobic and aerobic bacteria from commercial tattoo and permanent makeup inks

ABSTRACT Tattooing and use of permanent makeup (PMU) have dramatically increased over the last decade, with a concomitant increase in ink-related infections. Studies have shown evidence that commercial tattoo and PMU inks are frequently contaminated with pathogenic microorganisms. Considering that tattoo inks are placed into the dermal layer of the skin where anaerobic bacteria can thrive and cause infections in low-oxygen environments, the prevalence of anaerobic and aerobic bacteria should be assessed in tattoo and PMU inks. In this study, we tested 75 tattoo and PMU inks using the analytical methods described in the FDA Bacteriological Analytical Manual Chapter 23 for the detection of both aerobic and anaerobic bacterial contamination, followed by 16S rRNA gene sequencing for microbial identification. Of 75 ink samples, we found 26 contaminated samples with 34 bacterial isolates taxonomically classified into 14 genera and 22 species. Among the 34 bacterial isolates, 19 were identified as possibly pathogenic bacterial strains. Two species, namelyCutibacterium acnes(four strains) andStaphylococcus epidermidis(two strains) were isolated under anaerobic conditions. Two possibly pathogenic bacterial strains,Staphylococcus saprophyticusandC. acnes, were isolated together from the same ink samples (n= 2), indicating that tattoo and PMU inks can contain both aerobic (S. saprophyticus) and anaerobic bacteria (C. acnes). No significant association was found between sterility claims on the ink label and the absence of bacterial contamination. The results indicate that tattoo and PMU inks can also contain anaerobic bacteria. IMPORTANCE The rising popularity of tattooing and permanent makeup (PMU) has led to increased reports of ink-related infections. This study is the first to investigate the presence of both aerobic and anaerobic bacteria in commercial tattoo and PMU inks under aerobic and anaerobic conditions. Our findings reveal that unopened and sealed tattoo inks can harbor anaerobic bacteria, known to thrive in low-oxygen environments, such as the dermal layer of the skin, alongside aerobic bacteria. This suggests that contaminated tattoo inks could be a source of infection from both types of bacteria. The results emphasize the importance of monitoring these products for both aerobic and anaerobic bacteria, including possibly pathogenic microorganisms.

Biotechnology & Applied Microbiology↗

Q1 Report for FY25 Theory and Simulation Performance Target: Development of an integrated modeling framework for fusion reactor design and assessment

This report describes the work and activities carried out towards the completion of each of the following milestones in FY25 Q1: 1. Demonstrate workflow for generating self-consistent CESOL plasma profiles + first wall and divertor loading prediction and generate the CAT plasma and neutron loading needed for further engineering analysis: $/circ$ Initially run CESOL with SOLPS and map heat flux using simple HEAT method: ▪ Generate SOLPS grid for CAT reference case, ▪ Implement and apply ‘lower’ fidelity method of using HEAT-like analytic method to map SOLPS heat flux from charged particles to first wall, and ▪ Provide initial heat flux + neutron loading for further engineering analysis. 2. Demonstrate multiphysics magnet analysis: $/circ$ Demonstrate validation of the Elmer workflow by comparing induced stresses due to EM forces generated by TF coils using multiple codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fluoride Analysis by Ion Chromatography in Support of Fast Critical Assembly (FCA) Spent Nuclear Fuel Processing

INTRODUCTION The Savannah River Site (SRS) is currently processing Fast Critical Assembly (FCA) fuel received from the Japan Atomic Energy Agency (JAEA) for disposition. Stainless steel-clad plate and rods in stainless steel containers are dissolved using electrolysis with a solution mixture of nitric acid (HNO3), potassium fluoride (KF), and gadolinium (Gd). An ion chromatography (IC) was developed and vetted to monitor fluoride at various sampling points of the process. To finalize the method, FCA test solution was analyzed to qualify the analytical method followed by real FCA process solution analysis using two different analytical columns. This presentation summarizes the development and vetting of the IC method.

White, Thomas L. [Savannah River National Laborato↗

An analytic implementation of the IR-resummation for the BAO peak

We develop an analytic method for implementing the IR-resummation of [1], which allows one to correctly and consistently describe the imprint of baryon acoustic oscillations (BAO) on statistical observables in large-scale structure. We show that the final IR-resummed correlation function can be computed analytically without relying on numerical integration, thus allowing for an efficient and accurate use of these predictions on real data in cosmological parameter fitting. In this work we focus on the one-loop correlation function and the BAO peak. We show that, compared with the standard numerical integration method of IR-resummation, the new method is accurate to better than 0.2%, and is quite easily improvable. We also give an approximate resummation scheme which is based on using the linear displacements of a fixed fiducial cosmology, which when combined with the method described above, is about six times faster than the standard numerical integration. Finally, we show that this analytic method is generalizable to higher loop computations.

79 ASTRONOMY AND ASTROPHYSICS↗

CCUS 2024, Interpreting the strain tensor Larry Murdoch Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring during CCUS. We have demonstrated this method by deploying strainmeters at shallow depths (30 to 40m) and then conducting injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. We have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS. Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and our objective was to evaluate opportunities for strain monitoring during characterization and monitoring for CCUS. Our approach was to deploy strainmeters at shallow depths (30 to 40m) and then conduct injection well tests in an underlying reservoir at 530m depth. The results indicate that the horizontal strain at shallow strainmeters was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 ne/d over a few days (1 nanostrain = 1 part per billion strain). We then used the strain data to estimate reservoir properties, geometry and pressure through inversion of poroelastic forward models using both numerical and novel analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed fast, closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. This approach markedly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. Bayesian inversion is important because it provides predictions with uncertainties, which makes the results useful for decision making. In conclusion, we have shown with field tests and simulations that the strain tensor in the caprock is sensitive to pressure in the reservoir, reservoir properties and boundaries, and pressure in the caprock caused by leaks. These results indicate that measuring and interpreting the shallow strain tensor could be a valuable tool for both initial reservoir characterization efforts and long-term monitoring during CCUS.

Murdoch, Larry↗

International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Lithium isotopic analysis in depleted lithium salts

Lithium isotope separation processes require characterization of the isotopic compositions of the different output phases of the process. While considerable effort to develop isotope separation methods has been ongoing for decades, the analytical methods associated with these analyses are rarely provided. Here, in this work three types of mass spectrometers (Q-ICP-MS, MC-ICP-MS, TIMS) were tested for the ability to measure depleted lithium salts that are relevant materials for isotopic separations. Results indicate that, once stabilized, the Q-ICP-MS can provide equal precision for Li isotopic samples compared to TIMS or MC-ICP-MS. However, MC-ICP-MS consistently provides the highest precision for salts across both depleted and natural isotopic abundances. These data demonstrate that Q-ICP-MS is an appropriate choice for analysis of depleted lithium salts, especially when rapid analyses are desired for online process monitoring.

07 ISOTOPE AND RADIATION SOURCES↗

Plastic additives in the ocean: Use of a comprehensive dataset for meta-analysis and method development

In excess of 13,000 chemicals are added to plastics (‘additives’) to improve performance, durability, and production of plastic products. They are categorized into numerous chemical classes including flame retardants, light stabilizers, antioxidants, and plasticizers. While research on plastic additives in the marine environment has increased over the past decade, there is a lack of methodological standardization. To direct future measurement of plastic additives, we compiled a first-of-its-kind dataset of literature assessing plastic additives in marine environments, delineated by sample type (plastic debris, seawater, sediment, biota). Using this dataset, we performed a meta-analysis to summarize the state of the science. Currently, our dataset includes 217 publications published between 1978 and May 2023. The majority of publications analyzed plastic additives in biota collected from Europe and Asia. Analyses concentrated on plasticizers, brominated flame retardants, and bisphenols. Common sample preparation techniques included Solvent - Agitation extraction for plastic, sediment, and biota samples, and Solid Phase Extraction for seawater samples with dichloromethane and solvent mixtures including dichloromethane as the organic extraction solvent. Finally, most analyses were performed utilizing gas chromatography/mass spectrometry. There are a variety of data gaps illuminated by this meta-analysis, most notably the small number of compounds that have been targeted for detection compared to the large number of additives used in plastic production. The provided dataset facilitates future investigation of trends in plastic additive concentration data in the marine environment (allowing for comparison to toxicity thresholds) and acts as a starting point for optimizing and harmonizing plastic additive analytical methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation. This study examines five cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) selected as application models: IEU-MET- FAST-002-001, LEU-COMP-THERM-001-001, LEU-SOL-THERM-004-001, MIX-COMP- THERM-001-001, and U233-SOL-THERM-001-001. This is a continuation of a previous study to examine Pu and HEU cases: HEU-MET-FAST-013-001, HEU-SOL-THERM-001-008, PU-MET- FAST-022-001, and PU-SOL-THERM-001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL is computed using only bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS-8.24. Results comparison appears to show that benchmark selection has a greater influence on the USL than the method used for calculation of bias and bias uncertainty.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

BETO 2021 Peer Review - Analytical Development and Standardization for Biomass-Derived Thermochemical Liquids

This project began in FY14 to address the lack of standard chemical characterization analytical methods for bio-oils. Bio-oils are very complex and present numerous analytical challenges; yet reliable chemical information (quantification of both individual compounds and chemical functional groups) is needed to inform upgrading research and refinery co-processing. In this project, analysis needs are first determined from engaging the bioenergy community. Next, standard methods are developed to meet these needs, and then subsequently validated via inter-laboratory studies. Methods that are successfully validated (< 10% variability) are then shared as Laboratory Analytical Procedures (LAPs), which are free and publicly available. We have been tracking LAP use and have seen sustained usage as evidenced by an average of 500 pages views and 100 downloads per quarter, demonstrating the value of these methods to the bioenergy community. LAP methods that are particularly useful and reliable will be chosen for the next-level of standardization through ASTM. We have recently achieved approval by ASTM for our carbonyl titration method. This method (ASTM E3146) is the first example of an ASTM standard solely focused on the chemical characterization of bio-oils. Work in this project is meeting the analysis needs of the bioenergy community and will ultimately help enable the commoditization of bio-oils.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensitivity/Uncertainty Comparison Study Involving IRSN, LANL, and ORNL Tools to Support Validation [Abstract]

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize nuclear data from ENDF/B-VII.1 evaluation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

S/U Comparison Study with a Focus on USLs

Under a DOE Nuclear Criticality Safety Program (NCSP) task involving Analytical Methods, three Laboratories collaborated in a comparison of results obtained from Sensitivity/Uncertainty (S/U) packages relevant to validation of transport codes. The task involves Institut de Radioprotection et de Sûreté Nucléaire (IRSN), Los Alamos National Laboratory (LANL), and Oak Ridge National Laboratory (ORNL) comparing results of MORET 5/MACSENS V3.0, MCNP6.2/Whisper-1.1, and SCALE 6.2.3/TSUNAMI/USLSTATS respectively. All Monte Carlo transport code results utilize ENDF/B-VII.1. Four cases from the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook) were selected as application models: HEU-MET-FAST-013-001, HEU-SOL-THERM 001-008, PU-MET-FAST-022-001, and PU-SOL-THERM 001-001. Ultimately, comparison is made between Upper Subcritical Limits (USLs) obtained using each code package for each application case. Since differences exist in whether packages take into account margin of subcriticality (MOS), the USL may be computed using bias and bias uncertainty, also known as the calculational margin (CM) in ANSI/ANS 8.24. Application of portions of MOS to the USL for nuclear data uncertainty of and potential code margin is referred to as USL herein. In either case, additional MOS is considered for actual application cases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Analysis of Glycolate in Radioactive Waste by Ion Chromatography (IC) and Proton Nuclear Magnetic Resonance (H NMR)

Here, in preparation for implementing the Nitric-Glycolic (NG) acid flowsheet for the Savannah River Site (SRS) Liquid Waste System (LWS), analytical methods for determining glycolate at low concentration, below 20 mg/L in radioactive samples, were developed to support system management and safety. To accommodate the wide range of LWS matrix conditions, two alternative methods were developed, refined, and demonstrated for glycolate analysis in radioactive waste samples: ion chromatography (IC) and a proton nuclear magnetic resonance (H NMR). Investigators validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. The deployed IC method is applicable in low to moderate ionic strength samples and requires sample pretreatment using a Dionex OnGuard II H + cartridge. The deployed H NMR method is more labor intensive but provides options for a broader range of matrices. Based on the results, high quality glycolate analysis of the Defense Waste Processing Facility (DWPF) condensate in Tank 22 is feasible by IC down to approximately 12 mg/L. Using H NMR, glycolate may be determined to 8 mg/L or lower depending on the run time with the potential for broader applicability of the method to higher ionic strength conditions in other tanks of the SRS LWS.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

BETO 2021 Peer Review - Analytical Development & Support WBS 2.5.1.101

The objective of the Analytical Development and Support (ADS) Project is to produce and maintain the critical analytical methods and tools that enable evaluation of emerging biofuels R&D at NREL and in the broader biofuels research community. Our project is divided into two tasks: one task to develop novel analytical techniques and improve existing methods and one task to maintain existing analytical capabilities at NREL and provide outreach to the wider community. The ADS Project is world-recognized for our Laboratory Analytical Procedures (LAPS) which provide detailed procedures for compositional analysis of biomass and have been adopted as the de facto standards within the biofuels community largely due to the transparency of the methods and the high reputation of NREL's research. Our dialog with stakeholders allows us to provide robust, precise, accurate, and publicly available analytical procedures for better valuation of scientific tools such as our recent accomplishment in developing a cellulose assay to support the EPA and industry in calculation of converted cellulose during starch ethanol production. We continue to develop analytical capabilities to support BETO's directives to research cost advantaged fuels such as animal wastes and novel bioproducts like 2,3-Butane-diol.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analytical workflow dependence of experimental observables for uranium chemistries

In this work, we investigated how the sequencing of laboratory analytical methods used for chemical and morphological characterization influences analytical findings for particulate materials relevant to the nuclear fuel cycle, including UO2, U3O8, studtite (UO2O2·4H2O), and β-UO3, in the context of nuclear forensic analysis. Particles of each chemistry obtained from consistent production batches were exposed to Raman spectroscopy and scanning electron microscopy in varying orders to elucidate how the order in which the techniques are applied influences morphological and chemical observations as a function of particle size. The results indicate that particles from all four chemistries exposed to high-resolution electron imaging before Raman spectral analysis demonstrate optical vibrational spectral changes that reduce accurate interpretation of the underlying chemistry via Raman spectral analysis. We hypothesize that these changes are due to the thermal load of the electron beam imparted to the sample being unable to be dissipated by materials with poor thermal conduction properties. Results from this study will aid in determining best practices for forensic analysis procedures to reduce uncertainty in chemical determination of unknown particulate samples.

Manns, Rebecca [University of Nevada, Las Vegas]↗