Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Data Center Metering and Resource Guide

This document features guidance for data center owners and operators on implementing metering systems that allow their organizations to gather the necessary data for effective decision-making and energy-efficiency improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Johnson Space Center's Solar and Wind-Based Renewable Energy System

The NASA Johnson Space Center (JSC) in Houston, Texas has a Sustainability Partnership team that seeks ways for earth-based sustainability practices to also benefit space exploration research. A renewable energy gathering system was installed in 2007 at the JSC Child Care Center (CCC) which also offers a potential test bed for space exploration power generation and remote monitoring and control concepts. The system comprises: 1) several different types of photovoltaic panels (29 kW), 2) two wind-turbines (3.6 kW total), and 3) one roof-mounted solar thermal water heater and tank. A tie to the JSC local electrical grid was provided to accommodate excess power. The total first year electrical energy production was 53 megawatt-hours. A web-based real-time metering system collects and reports system performance and weather data. Improvements in areas of the CCC that were detected during subsequent energy analyses and some concepts for future efforts are also presented.

Vasquez, A.↗

Performance Testing of TRL4-6 LISA Laser System

The Laser Interferometer Space Antenna (LISA) is an ESA-led future mission to measure gravitational waves from astronomical sources in space. LISA has been adopted as a formal mission by ESA in January 2024, and is expected to become a formal project at NASA within 2024. The laser system (LS), which includes four laser heads (LH) each containing a laser optical module (LOM) and laser electronics module (LEM), a frequency reference system (FRS, optical frequency reference) and four power monitor detectors (PMON), is one of the three U.S. contributions to LISA from NASA. The Lasers and Electro-Optics Branch at NASA GSFC has been developing and managing the design of the LISA LS. Currently, the TRL (technology readiness level) of the NASA LISA laser system is transitioning from 4 to 6. TRL 4/5 LISA LOM was sent to ESA in early 2023 and has undergone optical performance testing. [1] By late summer of 2024, NASA plans to deliver the TRL 6 LOM to ESA for performance evaluation. Since the delivery of the TRL4/5 LOM to ESA, we have taken steps to advance the TRL of the overall LS and have also started end-to-end system level testing involving other subsystems. They include 1) optical performance test of TRL6 LOM and TRL 5 LEM under thermal cycling, 2) end-to-end test of the laser head (LH) and the GSE (ground support equipment) FRS, driven by TRL 4 FRS electronics (FRS-E) provided by Ball Aerospace, 3) end-to-end test of the laser head (LH) with the GSE phase meter system (PMS) provided by Albert Einstein Institute, and 4) optical performance test of the LH with the PMON subsystem developed by NASA. The FRS, PMS, and PMON provide necessary frequency stability, relative phase stability between lasers, and output power stability, respectively. Since they are all vital for the sensitive laser interferometry performed in LISA, it is necessary to perform these system level testing by combining the LH and other subsystems, and to prove the optical performance at an early stage during the LS development. Our recent work has successfully demonstrated the intra-connectivity of the LS, as well as critical external interface with the PMS to meet the LISA’s performance requirements. In this talk, we will report on the latest status of the LH testing and system level test. We will also discuss the paths to bring each subsystem to TRL6+ and plans for future system level testing.

LISA↗

Clustering and statistical analyses of air-conditioning intensity and use patterns in residential buildings

Energy conservation in residential buildings has gained increased attention due to its large portion of global energy use and potential of energy savings. Occupant behavior has been recognized as a key factor influencing the energy use and load diversity in buildings, therefore more realistic and accurate air-conditioning (AC) operating schedules are imperative for load estimation in equipment design and operation optimization. With the development of sensor technology, it became easier to access an increasing amount of heating/cooling data from thermal energy metering systems in residential buildings, which provides another possible way to understand building energy usage and occupant behaviors. However, except for cooling energy consumption benchmarking, there currently lacks effective and easy approaches to analyze AC usage and provide actionable insights for occupants. To fill this gap, this study proposes clustering analysis to identify AC use patterns of residential buildings, and develops new key performance indicators (KPIs) and data analytics to explore the AC operation characteristics using the long-term metered cooling energy use data, which is of great importance for inhabitants to understand their thermal energy use and save energy cost through adjustment of their AC use behavior. We demonstrate the proposed approaches in a residential district comprising 300 apartments, located in Zhengzhou, China. Main outcomes include: Representative AC use patterns are developed for three room types of residential buildings in the cold climate zone of China, which can be used as more realistic AC schedules to improve accuracy of energy simulation; Distributions of KPIs on household cooling energy usage are established, which can be used for household AC use intensity benchmarking and performance diagnoses.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

Overcoming Communications Outages in Inverter Downtime Analysis

This paper presents two methods of detecting inverter downtime and estimating lost production from downtime events using timeseries system production measurements. The methods focus on distinguishing communications interruptions from true production outages and are successful in most cases. To enable fleet-scale analysis of inverter availability, the methods are designed to be semi-autonomous. The first method uses only inverter and system meter AC power measurements while the second uses cumulative production and expected energy data to classify outages and estimate lost production. The methods are demonstrated using real field data and the results are discussed.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Itron Open Way Security Assessment - SCADA

INL in collaboration with Itron, Inc. performed a laboratory assessment on the Itron, Inc. OpenWay Automated Metering System. During this assessment, vulnerabilities were discovered, evaluated, and mitigation strategies developed. These results were reported to Itron, Inc. to guide their efforts towards improved cyber security of their Smartgrid products.

Source record↗

Expanding Midscale Solar: Examining the Economic Potential, Barriers, and Opportunities at Offices, Hotels, Warehouses, and Universities

The midscale market for solar photovoltaics (PV), defined as behind-the-meter systems between 100 kW and 2 MW, has grown more slowly than other PV market segments in recent years. A number of key barriers have impeded growth, including tenant and landlord split incentives, contracting challenges, the mismatch in building lease and PV financing terms, and high transaction costs relative to project sizes. This report explores prospects for expansion of the midscale solar market, with a focus on four building segments: offices, hotels, warehouses, and universities.

14 SOLAR ENERGY↗

Toward a laminar-flow-control transport

Analyses were conducted to define a practical design for an advanced technology laminar flow control (LRC) transport for initial passenger operation in the early 1990's. Mission requirements, appropriate design criteria, and level of technology for the study aircraft were defined. The characteristics of the selected configuration were established, aircraft and LFC subsystems compatible with the mission requirements were defined, and the aircraft was evaluated in terms of fuel efficiency. A wing design integrating the LFC ducting and metering system into advanced composite wing structure was developed, manufacturing procedures for the surface panel design were established, and environmental and structural testing of surface panel components were conducted. Test results revealed a requirement for relatively minor changes in the manufacturing procedures employed, but have shown the general compatibility of both the selected design and the use of composite materials with the requirements of LFC wing surface panels.

Sturgeon, R. F.↗

Combined effect of noise and vibration on passenger acceptance

An extensive research program conducted at NASA Langley Research Center to develop a comprehensive model of passenger comfort response to combined noise and vibration environments has been completed. This model was developed for use in the prediction and/or assessment of vehicle ride quality and as a ride quality design tool. The model has the unique capability to transform individual elements of vehicle interior noise and vibration into subjective units and combining the subjective units to produce a total subjective discomfort index as well as the other useful subjective indices. This paper summarizes the basic approach used in the development of the NASA ride comfort model, presents some of the more fundamental results obtained, describes several application of the model to operational vehicles, and discusses a portable, self-contained ride quality meter system that is a direct hardware/software implementation of the NASA comfort algorithm.

Leatherwood, J. D.↗

Feeder System For Particle-Size Analyzer

Feeder system meters precise stream of powder into precise flow of gas. Used to feed light-scattering particle-size analyzer that determines distribution of sizes of particles in powder. Dry analysis of powder takes about one-third time of conventional wet analysis and consumes less powder. Feed rate more precisely controllable, leading to more precision in analysis. In dry analysis, no need to dispose of hazardous liquid waste.

Ramsey, Keith E.↗

Hot gas ingestion effects on fuel control surge recovery and AH-1 rotor drive train torque spikes

This report summarizes the work accomplished through computer simulation to understand the impact of the hydromechanical turbine assembly (TA) fuel control on rocket gas ingestion induced engine surges on the AH-1 (Cobra) helicopter. These surges excite the lightly damped torsional modes of the Cobra rotor drive train and can cause overtorqueing of the tail rotor shaft. The simulation studies show that the hydromechanical TA control has a negligible effect on drive train resonances because its response is sufficiently attenuated at the resonant frequencies. However, a digital electronic control working through the TA control's separate, emergency fuel metering system has been identified as a solution to the overtorqueing problem. State-of-the-art software within the electronic control can provide active damping of the rotor drive train to eliminate excessive torque spikes due to any disturbances including engine surges and aggressive helicopter maneuvers. Modifications to the existing TA hydromechanical control are relatively minor, and existing engine sensors can be utilized by the electronic control. Therefore, it is concluded that the combination of full authority digital electronic control (FADEC) with hydromechanical backup using the existing TA control enhances flight safety, improves helicopter performance, reduces pilot workload, and provides a substantial payback for very little investment.

Tokarski, Frank↗

SOFIA Optical Design for the Aft Configuration

The Stratospheric Observatory for Infrared Astronomy (SOFIA) is a planned NASA facility consisting of an infrared telescope of 2.5 meter system aperture flying in a modified Boeing 747. It will have an image diameter of 1.5 arc seconds, an operating wavelength range from visible through 1 millimeter, an 8 arc minute field of view, and a chopping secondary. the configuration is a Cassegrian with a diagonal tertiary to direct the beam to a Nasmyth focus. The new choice of a location aft of the wings allows the primary mirror to have about an f/1.4 focal ratio, which is preferable to f/1.1 previously planned for the forward location.

Davis, Paul K.↗