Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “metering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

An analysis of maximum vertical gusts recorded at NASA's 150-meter ground winds tower facility at Kennedy Space Center, Florida

A statistical summary is presented of vertical wind speed data recorded at NASA's 150-Meter Ground Winds Tower Facility on Merritt Island, Kennedy Space Center, Florida. One year of continuous around-the-clock vertical wind speed measurements processed by the Automatic Data Acquisition System (ADAS) is classified as a function of tower level (10, 18, 60, and 150 meters) and period of reference day, month, season: winter (October through March) and summer (April through September), and annual. Intensity, frequency, time of occurrence, prevailing conditions, etc., of the daily maximum vertical gusts (i.e., updraft and downdraft) are determined. The results are compared with the vertical gusts associated with the daily maximum horizontal gust. The intent of this summarization of vertical wind speed data is to provide a general description of wind flow in the lower 150 meters of the atmosphere for the identification of hazards involved in wind shear encounters relative to ascent and descent of the Space Shuttle and conventional aircraft.

Alexander, M. B.↗

The 26-meter S-X Conversion Project

The 26-meter S-X conversion project provides for the conversion of an existing 26-meter S-band subnet to a 34-meter S- and X-band subnet. The subnet chosen for conversion consists of the following stations: DSS 12 near Barstow, DSS 44 in Australia, and DSS 62 in Spain. The main subsystems effected by this project are the antenna mechanical, antenna microwave, and receiver-exciter. In addition to these, there are many project-related electronic equipments that have been added to the existing station equipment. The major subsystems are essentially through the design stage with the antenna mechanical subsystem completed through detail design with procurement in process.

Lobb, V. B.↗

The 34-meter antenna-subreflector translations to maximize RF gain

The extension of the 26 meter antenna to 34 meter diameter decreased the F/D ratio. This F/D change resulted in unacceptable gain losses due to the hyperboloid's lateral deflections. A three direction translating mounting device was added to the hyperboloid. This device was controlled by a microprocessor to minimize the offsets of the phase centers in the cassegrain RF system and also compensated for boresight directions. The use of the radiation program to predict the gain losses from displacements computed by a structural computing program using an analytical model of the 34 meter reflector structure is discussed. Field test results showed accurate predictions for the Y and Z hyperboloid translations. In the X direction, the prediction value was low. However, the computed gain losses vs primary foci offsets by the radiation program were verified by field tests.

Katow, M. S.↗

Effects of aircraft and flight parameters on energy-efficient profile descents in time-based metered traffic

Concepts to save fuel while preserving airport capacity by combining time based metering with profile descent procedures were developed. A computer algorithm is developed to provide the flight crew with the information needed to fly from an entry fix to a metering fix and arrive there at a predetermined time, altitude, and airspeed. The flight from the metering fix to an aim point near the airport was calculated. The flight path is divided into several descent and deceleration segments. Descents are performed at constant Mach numbers or calibrated airspeed, whereas decelerations occur at constant altitude. The time and distance associated with each segment are calculated from point mass equations of motion for a clean configuration with idle thrust. Wind and nonstandard atmospheric properties have a large effect on the flight path. It is found that uncertainty in the descent Mach number has a large effect on the predicted flight time. Of the possible combinations of Mach number and calibrated airspeed for a descent, only small changes were observed in the fuel consumed.

Dejarnette, F. R.↗

Effects of aircraft and flight parameters on energy-efficient profile descents in time-based metered traffic

The influence of several parameters on the time required to fly a nominal profile descent of a B-737 from an entry fix to a metering fix 75 n.mi. away was studied. The ground distance for the constant speed segment was adjusted in each case so that the aircraft would always arrive at the metering fix position at the completion of the five segments of the profile descent. The influence of eight parameters on the same nominal profile descent is outlined, but the method used for the off nominal cases was changed. The time calculated for the constant speed segment in the nominal case is used for all off nominal cases. This method allows the aircraft to arrive at the metering fix before or after the profile descent is complete. It is shown that descent Mach number and wind speed have a large effect on the time error, whereas weight was a much smaller effect.

Dejarnette, F. R.↗

Development of the 15-meter hoop-column antenna system

The development of the 15-meter hoop/column antenna system is presented. The 15-meter deployable structure is discussed along with the mulitple-beam feed system development and the structures and RF testing planned in 1985. The topics presented are: overview of antenna development activities; development of 15-meter reflector and kinematic deployment tests; preliminary modal survey test results and future structural dynamics tests; and radio frequency subsystems and near field testing.

Campbell, T. G.↗

Hybrid TLC-pair meter for the Sphinx Project

The chief aims in THE SPHINX PROJECT are research of super lepton physics and new detector experiments. At the second phase of THE SPHINX PROJECT, a hybrid TLC-PAIR METER was designed for measuring high energy neutrino sources (E upsilon * TeV), searching high energy muon sources (E mu TeV) and measuring muon group (E mu 1 TeV). The principle of PAIR METER has been already proposed. In this TLC-PAIR METER, electromagnetic shower induced by cosmic ray muons are detected using TL (Thermoluminescence) sheets with position counters.

Wada, T.↗

A new 70-meter antenna quadripod with reduced RF blockage

The new subreflector mount (quadripod) for the 64-meter to 70-meter antenna extension project was the result of many trial designs aimed at reducing radio frequency spherical and plane wave blockage and minimizing structural weight while satisfying strength and natural frequency requirements. An optimum design emerged which has a gain improvement of 0.32 dB over the present 64-meter design. Some of the trial designs made and the final optimum configuration selected are described.

Cucchissi, J. J.↗

Near-field testing of the 15-meter model of the hoop column antenna. Volume 3: Near- and far-field plots for the JPL feed

Technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are discussed. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed system radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 3) gives the detailed patterns measured with the JPL feed (2.225 GHz). Volume 1 covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas, including the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, the test program outline, and a synopsis of antenna electromagnetic performance. A detailed listing of the antenna patterns for the LaRC feeds (7.3, 11.60, 2.27, and 4.26 GHz) are given in Volume 2 of this report.

Hoover, J.↗

Near-field Testing of the 15-meter Model of the Hoop Column Antenna

The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are documented. The antenna consists of a deployable central column and a 15 meter hoop, stiffened by cables into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume 1) covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas. This volume discusses the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, gives the test program outline, and gives a synopsis of antenna electromagnetic performance. Three techniques for measuring surface mechanical tolerances were used (theodolites, metric cameras, and near-field phase), but only the near-field phase approach is included. The report also includes an error analysis. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume 3 of this report, and for all other feeds in Volume 2.

Hoover, J.↗

Near-field testing of the 15-meter model of the hoop column antenna. Volume 2: Near- and far-field plots for the LaRC feeds

The technical results from near-field testing of the 15-meter model of the hoop column antenna at the Martin Marietta Denver Aerospace facility are described. The antenna consists of a deployable central column and a 15-meter hoop, stiffened by cable into a structure with a high tolerance repeatable surface and offset feed location. The surface has been configured to have four offset parabolic apertures, each about 6 meters in diameter, and is made of gold plated molybdenum wire mesh. Pattern measurements were made with feed systems radiating at frequencies of 7.73, 11.60, 2.27, 2.225, and 4.26 (all in GHz). This report (Volume II) gives the detailed patterns measured with the LaRC feeds (7.73, 11.60, 2.27, and 4.26 GHz). Volume I covers the testing from an overall viewpoint and contains information of generalized interest for testing large antennas, including the deployment of the antenna in the Martin Facility and the measurements to determine mechanical stability and trueness of the reflector surface, the test program outline, and a synopsis of antenna electromagnetic performance. A detailed listing of the antenna patterns are provided for the 2.225 Ghz feed in Volume III of this report.

Hoover, J.↗

Magnetic and electric field meters developed for the US Department of Energy

This report describes work done at the Jet Propulsion Laboratory for the Office of Energy Storage and Distribution of DOE on the measurement of power line fields. A magnetic field meter is discussed that uses fiber optics to couple a small measuring probe to a remote readout device. The use of fiber optics minimizes electric field perturbation due to the presence of the probe and provides electric isolation for the probe, so that it could be used in a high field or high voltage environment. Power to operate the sensor electronics is transferred via an optical fiber, and converted to electrical form by a small photodiode array. The fundamental, the second and third harmonics of the field are filtered and separately measured, as well as the broadband rms level of the field. The design of the meter is described in detail and data from laboratory tests are presented. The report also describes work done to improve the performance of a DC bushing in a Swedish factory, using the improved meter. The DC electric fields are measured with synchronous detection to provide field magnitude data in two component directions.

Kirkham, H.↗

Construction of the 16 meter Large Lunar Telescope (LLT)

The different materials that could be used to design the pedestal for a Moon based 16 meter telescope are discussed. The material that should be used has a low coefficient of thermal expansion, high modulus of elasticity, and high compressive and tensile strengths. For the model developed in this study, an aluminum-manganese alloy was used because of its low coefficient of thermal expansion. Due to variations in lunar soil conditions, both vertically and horizontally, three foundation systems are presented. The spudcan footing can be used in the case where dense soil is more than three meters. The spread footing is recommended where the dense soil is between one and three meters. Finally, in the third system, the Lunar Excursion Vehicle (LEV) is used as a base support for the telescope's pedestal. The LEV support requires a prepared site. The soil should be compacted and stabilized, if necessary, to reduce settlement.

Omar, Husam Anwar↗

Thin-film power-density meter for millimeter wavelengths

A quasi-optical power density meter for millimeter and submillimeter wavelengths has been developed. The device is a 2-cm2 thin-film bismuth bolometer deposited on a mylar membrane. The resistance responsivity is 150 Ohms/W, and the time constant is 1 min. The meter is calibrated at DC. The bolometer is much thinner than a wavelength, and can thus be modeled as a lumped resistance in a transmission-line equivalent circuit. The absorption coefficient is 0.5 for 189-Ohms/square film. The power-density meter has been used to measure absolute power densities for millimeter-wave antenna efficiency measurements. Absolute power densities of 0.5 mW/sq cm have been measured to an estimated accuracy of 5 percent.

Lee, Karen A.↗

Groundwater-Seepage Meter

Instrument measures seepage of groundwater into inland or coastal body of water. Positioned at depth as great as 40 meters, and measures flow at low rate and low pressure differential. Auxiliary pressure meter provides data for correlation of flow of groundwater with tides and sea states. Seepage meter operates independently for several weeks. Its sampling rate adjusted to suit hydrologic conditions; to measure more frequently when conditions changing rapidly. Used in water-quality management and for biological and geological research. Potential industrial uses include measurement of seepage of caustic and corrosive liquids.

Walthall, Harry G.↗

A study of the Lute Metering Structure

Two Metering Structure configurations were investigated. The first case was the traditional style metering structure which is larger than the outside diameter of the primary mirror. The second case investigated was the center support concept in which the outside diameter of the structure is less than the inside diameter of the primary mirror. Beryllium was used as the baseline material for this study. Four other materials were considered as candidates for the metering structure. These materials are: Graphite Epoxy, Aluminum, Titanium, and Invar. The loading conditions used for this study were estimated to be: Quasi Static: 6.0 G (all three directions); and Random Vibration: 30.0 G (applied 1 axis at a time). Taking advantage of symmetry, it was necessary to apply the lateral loading to only one axis. These loads were applied to both concepts and to all material configurations. The loadings as described above were based on the best available information and is felt to be adequate for this study since it was consistently used for all configurations. A load factor 2.00 was applied to both quasi static and random vibration loads. The allowable stresses are conservatively based yield strength of the material, except for the struts which are controlled by elastic stability. The stresses determined from each individual loading direction were conservatively combined by the absolute sum method.

Foreman, James W.↗

Photon-Weighted Midpoint Exposure Meter for Keck/HIRES Extrasolar Planet Research

NASA Grant was received for research involving the construction of a photon-weighting midpoint exposure meter for the Keck HIRES spectrometer, and for support of our NASA/Keck-based planet research with this instrumentation. The research funds were also to be used to make our iodine cell calibration system and exposure meter available to the NASA Keck observing community. Progress this past year, the second of the 3-year granting period, involved work in 4 areas: 1) Further construction of the midpoint exposure meter. 2) Assisting observers with use of the Iodine system. 3) Acquisition of precision radial velocity data on our program star sample with continued monitoring to proceed in subsequent years as available telescope time permits. 4) Reduction and analysis of incoming precision radial velocity data to reject problematic and uninteresting program stars, and to identify promising planet candidates.

Source record↗