Circulating Current Reduction of Back-to-Back MMC with Advanced Grid-Support Functionalities for Medium-Voltage Applications

A Lyapunov energy function based circulating current reduction scheme for a back to back modular multilevel converter based system for a microgrid application has been proposed in this digest. In order to ensure no circulating or zero sequence currents within the modules, the dynamics from one leg of the converter to the other are evaluated. A Lyapunov energy function is then developed and utilizing the circulating current dynamics of the converter the overall control law is implemented. In this digest a decentralized hierarchical control architecture has been implemented for the main current control; where the outer loop or the central controller implements the higher level grid interconnection functions as per IEEE 1547-2018 standards and the inner loop based on synchronous reference frame implements the current control architecture. The inner loops' outputs are the commanded converter voltages either on either side which are augmented by the Lyapunov energy function based circulating current suppression architecture. To evaluate the efficacy of the overall system, the overall system is modeled around a 300kVA back to back SiC multilevel modular converter used as a direct-connected medium voltage (MV) grid intertie based on MATLAB/Simulink domain. Several important case studies are presented in this paper to prove the effectiveness of the proposed architecture. case study results are presented.

circulating current↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

Multiscale Electrothermal Design of a Modular Multilevel Converter for Medium-Voltage Grid-Tied Applications

As a key feature of modular multilevel converters (MMCs), a large number of semiconductor devices are employed in the converter and distributed over a stack of submodules. Each submodule has a strict temperature limit that imposes constraints on the operating range of the converter. Different loading conditions/losses in the submodules lead to unavoidable temperature variations inside the MMC, which consequently affect the system-level performance and reliability. This paper is focused on the electrothermal analysis and design of a medium-voltage silicon carbide (SiC)-based MMC system, from submodule power semiconductors to the overall MMC system integration of multiple submodules, for grid-connected applications. Loss calculations are performed to estimate the cooling requirements and aid thermal design at different levels. The performance of a forced-air cooling approach is analyzed within a numerical modeling framework. Maximum temperature of the SiC power modules is predicted using numerical tools. Thermal design of the MMC cabinet with various arrangements of air inlet(s) and outlet(s) is investigated and compared from a cooling performance perspective. A fully resolved model of the arrangement that yields optimal results is developed to accurately predict the temperature profile of the essential components in the submodules.

computational fluid dynamics↗

Design and Optimization of a 200-kW Medium-Frequency Transformer for Medium-Voltage SiC PV Inverters

This paper presents a design and optimization methodology for a 200-kW medium-frequency transformer (MFT) based on low-loss magnetic core (FINEMET FT-3TL). The proposed optimal design methodology consists of predesign, preliminary design, and optimal design. In the preliminary design, the parallel-concentric winding structure is selected to increase the current carrying capability and reduce the leakage inductance. Based on the parallel-concentric winding concept, a novel cooing and insulation structure with 3-D printed bobbins are proposed. The optimal designed MFT prototype achieves a power density higher than 19.23 kW/L. The electrical insulation system is tested at 12 kV ac peak voltage. In addition, the partial discharge (PD) test is conducted at 7.5 kV ac peak voltage to ensure the PD-free design. The high-frequency bipolar pulsewidth modulation voltage insulation (PD) test is the first time applied in MFT design and test process. Finally, the transformer is applied in a dual-active-bridge (DAB) converter with 200 kW rated power. The peak efficiency of the DAB converter is 99.53%, and the efficiency at 200 kW is 98.85%. The peak efficiency of MFT is 99.844%, and the efficiency at 200 kW is 99.842%.

42 ENGINEERING↗

A Computational Efficient Space-Vector Modulation Scheme for A Hybrid Seven-Level Converter for Medium Voltage Grid-Tied Applications

In this paper, a fast space-vector modulation (SVM) scheme is proposed for a hybrid 7-level (7-L) converter, i.e., cascaded T-type converter and H-bridge converters, for grid-tied applications. Using oblique coordinate reference, the proposed SVM can quickly locate the switching triangle enclosing the reference vector in the 7-L space vector diagram. Then all available switching sequences and vector duty cycles are acquired by straightforward calculation without using any look-up tables, which significantly reduces the computational cost. The floating capacitor voltages are also stabilized by using the proposed SVM. Experimental studies on a scale-down prototype are presented in this work to validate the effectiveness of the proposed scheme.

Diao, Fei↗

The Impact of the Lightning Surge on SiC-based Medium-voltage Three-phase Four-wire Grid-connected Converters

The surge voltage induced by lightning will generate an inrush current in a grid-connected converter. It may not be large in Si-based converters because of the large grid side inductive filter. However, for SiC-based multi-level converters, the inrush current could be very large due to the small filter inductance, which is selected based on the current harmonic consideration. Most previous work focuses on system-level lightning protection while the converter-level impact, especially the internal components of the converter, is rarely discussed. This paper presents the analysis of the impact of the lightning surge on a 10 kV SiC MOSFET-based 13.8 kV three-phase four-wire grid-connected converter. The IEEE arrester model and the combined wave generator model in IEC 61000-4-5 standard are used to evaluate the inrush current, DC-link overvoltage, and component-to-ground potential of the converter. Analysis and simulation results have been provided to demonstrate the impact of lightning on the grid-connected converter. It is found that large inrush current occurs due to the small filter inductance, and the neutral-to-ground impedance impacts both the inrush current and the neutral point-to-ground potential.

Li, Haiguo↗

Hardware Design of Medium Voltage SiC-Based Modular Multilevel Converters for Grid-Tied Applications

This paper presents a design of a 10 kV silicon carbide (SiC) MOSFET based modular multilevel converter (MMC). The MMC functions as the interconnection between a 24 kV dc bus and a 13. SkV distribution grid. This paper focuses on the hardware design of the MMC and its submodules. The gate driver, auxiliary power supply and bus bur in submodules are major components that need to meet high dv/dt immunity and high insulation voltage requirements. The gate driver achieves over 200 kV/us common mode transient immunity (CMTI). Its associated auxiliary power supply is based on an on-board transformer with over 30 kV insulation capability and 1.4 pF barrier capacitance. The busbar achieves less than 11 kV/cm electric field in the air to avoid partial discharges. Validation tests of the MMC submodule were performed by double pulse tests at 5 kV and buck converter tests at3 kV, 52A (peak). Reliable operations were achieved in validation tests.

auxiliary power supply↗