Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Optical distance measuring instrument

An optical instrument, such as a stability monitor or a target range finder, uses an unstabilized laser to project a composite optical signal of coherent light having two naturally occurring longitudinal mode components. A beamsplitter divides the signal into a reference beam which is directed toward one photodetector and a transmitted beam which illuminates and is reflected from a distant target onto a second photodetector optically isolated from the first photodetector. Both photodetectors are operated on the square law principle to provide electrical signals modulated at a frequency equal to the separation between the frequencies of the two longitudinal mode components of the optical signal projected by the laser. Slight movement of the target may be detected and measured by electrically monitoring the phase difference between the two signals provided by the photodetectors and the range of the target measured with the aid of a microprocessor by changing the separation between the longitudinal modes by shifting the length of the resonator cavity in an iterative series of increments.

Abshire, J. B.↗

Log amplifier instrument measures physiological biopotentials over wide dynamic range

To record biopotentials with extreme dynamic ranges, biopotential inputs are capacitatively coupled to a miniature, low power, solid-state signal conditioner consisting of a two-stage differential preamplifier that has a low noise figure. The ouput of the preamplifier uses diodes to provide an overall gain which is nearly logarithmic.

Kado, R. T.↗

Instrument measures many optical properties in visible and IR

Electro-optical system measures reflectance, reflectance ratio, transmission, absorption, refractive index, and absorption coefficient in both visible and infrared (IR) spectral regions. System effectively combining capabilities of ellisometer, reflectometer, and spectrophotometer is expected to find application in environmental and material composition testing fields.

Batten, C. E.↗

Microwave Ice-Accretion Measurement Instrument (MIAMI)

Instrument used on operations aircraft to warn pilot of onset of dangerous ice buildup or as research tool for use in studying aircraft icing phenomena and in cloud research. MIAMI is embedded in surface to be monitored and conforms to surface contour.

Magenheim, B.↗

Instrument Measures Airflow Friction Without Contact

Dual beam laser interferometer determines airflow friction against body by measuring time-varying thickness of wind sheared oil film. Measurements yield skin friction between film and airstream. Errors from prerun oil flow, tunnel starting transients, and initial surface waves therefore eliminated.

Monson, D. J.↗

Laser-Based Instrument Measures Propagation Of Cracks

Report describes use of commerical laser displacement meter to measure propagation of cracks in stainless-steel specimens in stress tests in corrosive (salt-spray) environment. Measurements directed toward determining time from beginning of each test until onset of propagation of crack.

Lee, Rupert U.↗

Measurement Instruments

International Technology Corporation (INTEC) manufactures a line of instruments used for determining the optical properties of materials used in solar energy applications. Some of INTEC's instruments are based on NASA technology, including the Willey Alpha Meter and McDonald Emissometer. The emissometer is a commercial version of a system developed by Lewis Research Center to test efficiency- increasing coatings on solar panels. These instruments are used by manufacturers of solar equipment, government, university and private laboratories.

Source record↗

Calibrating Airplane Instrumentation To Measure Winds

Elaborate combination of techniques used to calibrate wind-measuring instrumentation aboard F104 airplane. Obtains wind profiles more rapidly. Airplane equipped with standard NACA research nose boom, including pressure probes and flow vanes yielding data on static and total pressures, angle of attack, and angle of sideslip. Has ring-laser-gyroscope inertial reference unit, giving linear and angular velocities, linear acceleration, and orientation of airplane. Body-mounted total-temperature sensor also used. Improved method of calibration devised to determine whether winds aloft at and shortly after time of measurement allow safe launch of Space Shuttle. Proves beneficial in other safety- or research-oriented applications in which wind velocities over range of altitudes must be determined in nearly real time.

Haering, Edward A., Jr.↗

Pinhole Calibrator For Particle-Sizing Instrument

Rotating-pinhole calibrator designed for use in calibrating and testing optical instrument measuring sizes of cloud droplets, dust particles, and other small particles suspended in flowing air. Easily attachable to particle-size-measuring instrument and suitable for both quick verification of calibration in field and detailed calibration studies in laboratory. Calibrator used to determine such operating parameters of instrument as optical collection angles, depth of field, profile of laser beam used to measure particles, and response to trajectory of particle. Also used to align instrument. Pinhole reused any number of times without risk of variation in diffraction pattern. Furthermore, size of pinhole chosen precisely and at will.

Hovenac, Edward↗

Biomagnetic instrumentation and measurement

The instruments and techniques of biomagnetic measurement have progressed greatly in the past 15 years and are now of a quality appropriate to clinical applications. The paper reports on recent developments in the design and application of SQUID (Superconducting Quantum Interference Device) magnetometers to biomagnetic measurement. The discussion covers biomagnetic field levels, magnetocardiography, magnetic susceptibility plethysmography, ambient noise and sensor types, principles of operation of a SQUID magnetometer, and laboratory techniques. Of the many promising applications of noninvasive biomagnetic measurement, magnetocardiography is the most advanced and the most likely to find clinical application in the near future.

Iufer, E. J.↗