Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

Characterization of Measurement Error Sources in Doppler Global Velocimetry

Doppler global velocimetry uses the absorption characteristics of iodine vapor to provide instantaneous three-component measurements of flow velocity within a plane defined by a laser light sheet. Although the technology is straightforward, its utilization as a flow diagnostics tool requires hardening of the optical system and careful attention to detail during data acquisition and processing if routine use in wind tunnel applications is to be achieved. A development program that reaches these goals is presented. Theoretical and experimental investigations were conducted on each technology element to determine methods that increase measurement accuracy and repeatability. Enhancements resulting from these investigations included methods to ensure iodine vapor calibration stability, single frequency operation of the laser and image alignment to sub-pixel accuracies. Methods were also developed to improve system calibration, and eliminate spatial variations of optical frequency in the laser output, spatial variations in optical transmissivity and perspective and optical distortions in the data images. Each of these enhancements is described and experimental examples given to illustrate the improved measurement performance obtained by the enhancement. The culmination of this investigation was the measured velocity profile of a rotating wheel resulting in a 1.75% error in the mean with a standard deviation of 0.5 m/s. Comparing measurements of a jet flow with corresponding Pitot measurements validated the use of these methods for flow field applications.

Meyers, James F.↗

Measurement Error Variance Estimation in Gamma-Spectroscopy Data using FRAM

The FRAM gamma-ray isotopic analysis code has recently been applied to four Pu data sets and four U data sets, each with relatively well-characterized standard items, in order to estimate the variances of random errors and of item-specific systematic errors. Assay results are available for Pu238, Pu239, Pu240, Pu241, Pu242 (operator entered, not independently measured), Am241, Specific Power, and Pu240eff. For the four U data sets, results are available for the measurands U234, U235, U236 (operator entered, not independently measured), and U238. For example, in Pu data set 1, there are 33 standard reference Pu items, which have well-known nominal/true values (except for a few items). FRAM was used to make approximately 15 repeat measurements for each of the 33 items, so empirical standard deviations can be calculated. In addition, FRAM internally estimates its random error variance using propagation of variance. This paper applies analysis of variance (ANOVA) to separately estimate the repeatability standard deviation and the standard deviation of the item-specific biases δ s in each of the 8 data sets.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Horizon sensor errors calculated by computer models compared with errors measured in orbit

Using a computer program to model the earth's horizon and to duplicate the signal processing procedure employed by the ESA (Earth Sensor Assembly), errors due to radiance variation have been computed for a particular time of the year. Errors actually occurring in flight at the same time of year are inferred from integrated rate gyro data for a satellite of the TIROS series of NASA weather satellites (NOAA-A). The predicted performance is compared with actual flight history.

Ward, K. A.↗

Aerial measurement error with a dot planimeter: Some experimental estimates

A shape analysis is presented which utilizes a computer to simulate a multiplicity of dot grids mathematically. Results indicate that the number of dots placed over an area to be measured provides the entire correlation with accuracy of measurement, the indices of shape being of little significance. Equations and graphs are provided from which the average expected error, and the maximum range of error, for various numbers of dot points can be read.

Yuill, R. S.↗

Measurement error analysis in determination of small-body gravity fields

We consider analytically the use of existing instrumentation in determining asteroid gravity fields from orbiting spacecraft. Asteroids (Eros as an example) are modeled as homogeneous triaxial ellipsoids, with gravitational potential given by a sperical-harmonic expansion. Mass concentrations are modeled as point masses. The character of spacecraft orbits about asteroids is discussed, along with detectibility of gravitational coefficients and of mass concentrations. A Kalman-filtering treatment of the observation process, for Eros as example, shows that using DSN tracking and onboard gravity gradiometry, radar altimetry, and celestial angle measurements, a single orbit yields asteroid mass to 0.03% and coefficients C20 to C44 to 1% accuracies.

Friedlander, A. L.↗

Altimeter height measurement errors introduced by the presence of variable cloud and rain attenuation

It has recently been recognized that spatially inhomogeneous clouds and rain can substantially affect the height precision obtainable from a spaceborne radar altimeter system. Through computer simulation, it has been found that typical levels of cloud and rain intensities and associated spatial variabilities may degrade altimeter precision at 13.5 GHz and, in particular, cause severe degradation at 35 GHz. This degradation in precision is a result of radar signature distortion caused by variable attenuation over the beam limited altimeter footprint. Because attenuation effects increase with frequency, imprecision caused by them will significantly impact on the frequency selection of future altimeters. In this paper the degradation of altimeter precision introduced by idealized cloud and rain configurations as well as for a realistic rain configuration as measured with a ground based radar is examined.

Monaldo, F. M.↗

Altimeter height measurement error introduced by the presence of variable cloud and rain attenuation

It has recently been recognized that spatially inhomogeneous clouds and rain can substantially affect the height precision obtainable from a spaceborne radar altimeter system. Through computer simulation, it has been found that typical levels of cloud and rain intensities and associated spatial variabilities may degrade altimeter precision at 13.5 GHz and, in particular, cause severe degradation at 35 GHz. This degradation in precision is a result of radar signature distortion caused by variable attenuation over the beam limited altimeter footprint. Because attenuation effects increase with frequency, imprecision caused by them will significantly impact on the frequency selection of future altimeters. In this paper the degradation of altimeter precision introduced by idealized cloud and rain configurations as well as for a realistic rain configuration as measured with a ground based radar is examined.

Monaldo, F. M.↗