SEARCH · Engineering Papers
Results for “mass spectrometry imaging”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Helium Ion Microscopy with Secondary Ion Mass Spectrometry for Nanoscale Chemical Imaging and Analysis of Polyolefins
To date, chemical imaging of polymers and polymer blends has been primarily accomplished using time-of-flight secondary ion mass spectrometry (ToF-SIMS) to directly visualize the distribution of components in a complex material with spatial resolution ranging from 100 nm to 5 μm. However, in many cases, this resolution falls far short of visualizing interfaces directly. To overcome these limitations, recent work has focused on developing a SIMS detection system based on a helium ion microscope (HIM) enabling chemical imaging with a demonstrated ~14 nm spatial resolution. Here, we utilize HIM-SIMS for differentiation between the olefin-based polymers of polyethylene (PE) and polypropylene (PP). We illustrate both analyses for separating PE and PP using specific mass fragment ratios as well as demonstrate spatially resolved imaging of phase-separated domains within PE. Altogether, we demonstrate the abilities of HIM-SIMS as a multimodal chemical technique for imaging and quantification of polyolefin interfaces, which could be more broadly applied to the analysis of more complex polymeric systems.
Phase-Imaging Ion-Cyclotron-Resonance mass spectrometry with the Canadian Penning Trap at CARIBU
The Canadian Penning Trap mass spectrometer (CPT) has conducted precision mass measurements of neutron-rich nuclides from the CAlifornium Rare Isotope Breeder Upgrade (CARIBU) of the Argonne Tandem Linac Accelerator System (ATLAS) facility at Argonne National Laboratory using the Phase-Imaging Ion-Cyclotron-Resonance (PI-ICR) technique for over half a decade. Here, in this study, we discuss the CPT system, and methods to improve accuracy and precision in mass measurement using PI-ICR including some optimization techniques and recently studied systematic effects.
The Determination of the Spatial Distribution of Indigenous Lipid Biomarkers in an Immature Jurassic Sediment Using Time-of-Flight–Secondary Ion Mass Spectrometry
The ability to detect and map lipids, including potential lipid biomarkers, within a sedimentary matrix using mass spectrometry (MS) imaging may be critical to determine whether potential lipids detected in samples returned from Mars are indigenous to Mars or are contaminants. Here, we use gas chromatography–mass spectrometry (GC-MS) and time-of-flight–secondary ion mass spectrometry (ToF-SIMS) datasets collected from an organic-rich, thermally immature Jurassic geologic sample to constrain MS imaging analysis of indigenous lipid biomarkers in geologic samples. GC-MS data show that the extractable fractions are dominated by C 27 –C 30 steranes and sterenes as well as isorenieratene derivatives. ToF-SIMS spectra from organic matter-rich laminae contain a strong, spatially restricted signal for ions m/z 370.3, m/z 372.3, and m/z 386.3, which we assign to C 27 sterenes, cholestane (C 27 ), and 4- or 24-methyl steranes (C 28 ), respectively, as well as characteristic fragment ions of isorenieratene derivatives, including m/z 133.1, m/z 171.1, and m/z 237.1. We observed individual steroid spatial heterogeneity at the scale of 10's to 100's of microns. The fine-scale heterogeneity observed implies that indigenous lipid biomarkers concentrated within specific regions may be detectable via ToF-SIMS in samples with even low amounts of organic carbon, including in samples returned from Mars.
Machine Learning Correlation of Electron Micrographs and ToF-SIMS for the Analysis of Organic Biomarkers in Mudstone
The spatial distribution of organics in geological samples can be used to determine when and how these organics were incorporated into the host rock. Mass spectrometry (MS) imaging can rapidly collect a large amount of data, but ions produced are mixed without discrimination, resulting in complex mass spectra that can be difficult to interpret. Here, we apply unsupervised and supervised machine learning (ML) to help interpret spectra from time-of-flight-secondary ion mass spectrometry (ToF-SIMS) of an organic-carbon-rich mudstone of the Middle Jurassic of England (UK). It was previously shown that the presence of sterane molecular biomarkers in this sample can be detected via ToF-SIMS (Pasterski, M. J. et al., Astrobiology 2023, 23, 936). We use unsupervised ML on scanning electron microscopy–electron dispersive spectroscopy (SEM-EDS) measurements to define compositional categories based on differences in elemental abundances. We then test the ability of four ML algorithms─k-nearest neighbors (KNN), recursive partitioning and regressive trees (RPART), eXtreme gradient boost (XGBoost), and random forest (RF)─to classify the ToF-SIM spectra using (1) the categories assigned via SEM-EDS, (2) organic and inorganic labels assigned via SEM-EDS, and (3) the presence or absence of detectable steranes in ToF-SIMS spectra. In terms of predictive accuracy and balanced accuracy, KNN was the best performing model and RPART the worst. The feature importance, or the specific features of the ToF-SIM spectra used by the models to make classifications, cannot be determined for KNN, preventing posthoc model interpretation. Nevertheless, the feature importance extracted from the other models was useful for interpreting spectra. In conclusion, we determined that some of the organic ions used to classify biomarker containing spectra may be fragment ions derived from kerogen which is abundant in this mudstone sample.
Using Model-Based Reasoning for Autonomous Instrument Operation
Multiprobe missions are an important part of NASA's future: Cluster, Magnetospheric Multi Scale, Global Electrodynamics and Magnetospheric Constellation are representatives from the Sun-Earth Connections Theme. To make such missions robust, reliable, and affordable, ideally the many spacecraft of a constellation must be at least as easy to operate as one spacecraft is today. To support this need for scalability, science instrumentation must become increasingly easy to operate, even as this same instrumentation becomes more capable and advanced. Communication and control resources will be at a premium for future instruments. Many missions will be out of contact with ground operators for extended periods either to reduce operations cost or because of orbits that limit communication to weekly perigee transits. Autonomous capability is necessary if such missions are to effectively achieve their operational objectives. An autonomous system is one that acts given its situation in a mission appropriate manner without external direction to achieve mission goals. To achieve this capability autonomy must be built into the system through judicious design or through a built-in intelligence that recognizes system state and manages system response. To recognize desired or undesired system states, the system must have an implicit or explicit understanding of its expected states given its history and self observations. The systems we are concerned with, science instruments, can have stringent requirements for system state knowledge in addition to requirements driven by health and safety concerns. Without accurate knowledge of the system state, the usefulness of the science instrument may be severely limited. At the same time, health and safety concerns often lead to overly conservative instrument operations further reducing the effectiveness of the instrument. These requirements, coupled with overall mission requirements including lack of communication opportunities and tolerance of environmental hazards, frame the problem of constructing autonomous science instruments. we are developing a model of the Low Energy Neutral Atom instrument (LENA) that is currently flying on board the Imager for Magnetosphere-to-Aurora Global Exploration (IMAGE) spacecraft. LENA is a particle detector that uses high voltage electrostatic optics and time-of-flight mass spectrometry to image neutral atom emissions from the denser regions of the Earth's magnetosphere. As with most spacecraft borne science instruments, phenomena in addition to neutral atoms are detected by LENA. Solar radiation and energetic particles from Earth's radiation belts are of particular concern because they may help generate currents that may compromise LENA's long term performance. An explicit model of the instrument response has been constructed and is currently in use on board IMAGE to dynamically adapt LENA to the presence or absence of energetic background radiations. The components of LENA are common in space science instrumentation, and lessons learned by modelling this system may be applied to other instruments. This work demonstrates that a model-based approach can be used to enhance science instrument effectiveness. Our future work involves the extension of these methods to cover more aspects of LENA operation and the generalization to other space science instrumentation.
Direct Visualization of Chemical Cues and Cellular Phenotypes throughout Bacillus subtilis Biofilms
Bacterial biofilms are complex and heterogeneous structures. Cells within biofilms carry out numerous metabolic processes in a nuanced and organized manner, details of which are still being discovered.
Ecosystem consequences of a nitrogen-fixing proto-organelle
Microscale symbioses can be critical to ecosystem functions, but the mechanisms of these interactions in nature are often cryptic. Here, we use a combination of stable isotope imaging and tracing to reveal carbon (C) and nitrogen (N) exchanges among three symbiotic primary producers that fuel a salmon-bearing river food web. Bulk isotope analysis, nanoSIMS (secondary ion mass spectrometry) isotope imaging, and density centrifugation for quantitative stable isotope probing enabled quantification of organism-specific C- and N-fixation rates from the subcellular scale to the ecosystem. After winters with riverbed-scouring floods, the macroalga Cladophora glomerata uses nutrients in spring runoff to grow streamers up to 10 m long. During summer flow recession, riverine N concentrations wane and Cladophora becomes densely epiphytized by three species of Epithemia, diatoms with N-fixing endosymbionts (proto-organelles) descended from a free-living Crocosphaera cyanobacterium. Over summertime epiphyte succession on Cladophora, N-fixation rates increased as Epithemia spp. became dominant, Cladophora C-fixation declined to near zero, and Epithemia C-fixation increased. Carbon transfer to caddisflies grazing on Cladophora with high densities of Epithemia was 10-fold higher than C transfer to caddisflies grazing Cladophora with low Epithemia loads. In response to demand for N, Epithemia allocates high levels of newly fixed C to its endosymbiont. Consequently, these endosymbionts have the highest rates of C and N accumulation of any taxon in this tripartite symbiosis during the biologically productive season and can produce one of the highest areal rates of N-fixation reported in any river ecosystem.
Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution
Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.
Spatially resolved absolute quantitation in thin tissue by mass spectrometry
Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. Furthermore, this review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.
Advances in mass spectrometry-enabled multiomics at single-cell resolution
We report biological organisms are multifaceted, intricate systems where slight perturbations can result in extensive changes in gene expression, protein abundance and/or activity, and metabolic flux. These changes occur at different timescales, spatially across cells of heterogeneous origins, and within single-cells. Hence, multimodal measurements at the smallest biological scales are necessary to capture dynamic changes in heterogeneous biological systems. Of the analytical techniques used to measure biomolecules, mass spectrometry (MS) has proven to be a powerful option due to its sensitivity, robustness, and flexibility with regard to the breadth of biomolecules that can be analyzed. Recently, many studies have coupled MS to other analytical techniques with the goal of measuring multiple modalities from the same single-cell. It is with these concepts in mind that we focus this review on MS-enabled multiomic measurements at single-cell or near-single- cell resolution.
ToF-SIMS imaging reveals that p -hydroxybenzoate groups specifically decorate the lignin of fibres in the xylem of poplar and willow
Esterified phenolics occur as γ-linked lignin acylations in many plant taxa but little is known about the distribution or function of such groups. In the family Salicaceae, p-hydroxybenzoate groups are present in the lignin of poplars (Populus spp.) and willows (Salix spp.). In this study, the distribution of cell wall-bound p-hydroxybenzoate was examined in different tissue and cell types of poplar and willow trees. This analysis showed that p-hydroxybenzoate groups were most prevalent in juvenile stems, and were elevated in tension wood and following nitrogen fertilisation. Closer examination of stem cross-sections using time-of-flight secondary-ion mass spectrometry (ToF-SIMS) directly showed that p-hydroxybenzoate groups occur predominantly in the cell walls of fibres and are largely absent from vessel elements. Furthermore, these results point to a role for ester-linked groups in modifying the syringyl-rich lignin of fibres, perhaps to strengthen the cell walls of these structural elements or to increase lignification rates.
Correlative electron and ion beam analysis of the electrochemical performances of LiV 3 O 8 cathode films as a function of microstructures
Degradation mechanisms in LiV 3 O 8 cathode films (~500 nm) with different initial microstructures i.e., globular nanocrystals in amorphous matrix and needle-like nanocrystals, synthesized by annealing the cathodes at 150 °C and 300 °C for 6 h are studied by Transmission Electron Microscopy (TEM) and Auger Electron Spectroscopy (AES). In addition, a unique in-situ combination of TEM and Secondary Ion Mass Spectrometry (SIMS) imaging techniques, namely Parallel Ion and Electron beam Spectrometry (PIES) is carried out to measure the 3D distribution of V and Li with nanoscale resolution. These characterization studies focus on correlating the pre- and post-cycling microstructure to observed electrochemical performance. The LiV 3 O 8 cathode film with needle-like nanocrystals (300 °C) shows a higher initial capacity but it degrades rapidly compared to the film with globular nanocrystals embedded in amorphous matrix (150 °C). We observed that LiV 3 O 8 films with needle-like nanocrystals are more susceptible to cathode decohesion and vanadium dissolution than the films with globular nanocrystals embedded in amorphous matrix, explaining the differences in their electrochemical performance. The findings from this study have relevance to the development of thin film electrode microstructures for high capacity and cyclic stability.
Intrinsic Halide Immiscibility in 2D Mixed-Halide Ruddlesden–Popper Perovskites
Halide alloying of 3D and 2D Ruddlesden–Popper lead halide perovskites (RPPs) allows their bandgaps to be fine-tuned for optoelectronic applications. Many studies of mixed-halide RPPs assume that halide mixing yields homogeneous alloys like in 3D lead halide perovskites, with halide segregation only occurring under perturbations like light or heat. Here we carefully investigate the mixed I/Br phases in solution grown microplates of three representative n = 1 and n = 2 RPP phases to reveal heterogeneous halide microscale domains – even in absence of photoinduced phase separation. Such halide immiscibility is revealed by X-ray diffraction and heterogeneity is confirmed by secondary ion mass spectrometry (SIMS) imaging, however, comparison with photoluminescence (PL) imaging results show how PL information alone can falsely imply homogeneous alloy formation in heterogeneous RPPs. Finally, we then demonstrate the use of spectral imaging as an alternative high-throughput tool for accurate halide phase characterization in mixed-halide RPPs.
Improved Fundamental Understanding of Aluminum Chemistry and Interactions of Aluminate Anion with Co-Anions: ORNL Project Progress Report
The U.S. Department of Energy (DOE)’s Hanford Site in Washington State houses 177 underground storage tanks containing millions of gallons of nuclear and chemical waste with high aluminum content. Aluminum (Al) salt reactions with strong bases produce aluminum hydroxides, like boehmite (γ-AlOOH), which are main components of insoluble nuclear waste sludge. Understanding the morphology, crystallinity, and dissolution behavior of boehmite under waste tank conditions is necessary for improving waste management and mitigation strategies. The ORNL team uses in situ multimodal analysis strategy to study Al chemistry of simulated tank waste using microfluidic reactors and advanced chemical imaging and mass spectrometry (MS) techniques. Because the SALVI device is vacuum compatible and transferrable among different platforms, we can use it in scanning electron microscopy (SEM), vacuum ultraviolet single photon mass spectrometry (VUV SPI-MS), and time-of-flight secondary ion mass spectrometry (ToF-SIMS) to study the chemical speciation and colloid stability in liquids in this project. Additionally, ex situ transmission electron microscopy (TEM) and x-ray diffraction (XRD) spectroscopy can be used to verify particle phase to further the understanding of the Al-bearing phases. This report gives a summary of the technical progress of the ORNL tasks. A plan for year 2 performance is recommended in the summary.
Indigenous Organic Molecular Biosignatures are Detectable via ToF-SIMS of a Kerogen-rich Jurassic Clay
Time of Flight - Secondary Ion Mass Spectrometry (ToF-SIMS) is a Mass Spectrometry (MS) imaging technique that can be used in conjunction with traditional organic geochemical analysis (organics extracted from a crushed sample) in order to determine how molecules observed in the organic extracts were incorporated into a particular rock sample. This type of analysis may be used on samples collected as part of Mars Sample Return (MSR) in order to determine if potential organic compounds were indigenous to Mars or whether they are contaminants.Here we show that Organic Molecular Biosignatures (OMBs including steranes and derivatives of a carotenoid) are detectable via ToF-SIMS within a Jurassic mudstone. The OMBs are only detectable in areas with high organic carbon, likely kerogen, indicating that they are indigenous to the rock. We conclude that: I) Indigenous OMBs are detectable via ToF-SIMS in ancient, kerogen-rich samples; II) the presence of a molecular ion strengthens the interpretation of ToF-SIMS spectra of complex natural material, and III) the spatial co-occurrence of kerogen and potentially indigenous OMBs in ancient sediments is a valid test of their character. These conclusions are directly relevant to MSR sample selection as well as the analysis of MSR samples upon return.
Development of microchannel plates in advanced wind-tunnel instrumentation
Microchannel plate (MCP) electron multiplier dynamic range has been increased 3 to 4 orders of magnitude at ambient temperatures, through enhanced input count rate capability and reduced background or 'dark' noise. The previous upper limit of roughly 10(exp 7) - 10(exp 8) cm(exp -2)s(exp -1) at ambient has been extended to levels approach 10(exp 10) cm(exp -2)s(exp -1) under continuous dc operation. The lower limit, previously set by an irreducible background component (approximately 0.6 cm(exp -2)s(exp -1)), has been lowered to the cosmic ray limit of .01 cm(exp -2)s(exp -1). The high end improvement was achieved by conductively cooling a very low resistance MCP by bonding it to a heat sink, while maintaining pulse-counting operation with multianode readouts. The low-end improvement was achieved by removing all radioisotopes from the MCP matrix glass. The detectors will benefit optical and mass spectrometry, flow visualization, plasma diagnostics, magnetometry, and other high signal flux applications. Very low MCP background noise will benefit X-ray and UV astronomy, medical imaging, trace isotope mass spectrometry, and other applications where the signal flux is often extremely low.
Molecular imaging of plant-microbe interactions on the Brachypodium seed surface
Plant growth-promoting rhizobacteria (PGPR) play a crucial role in biological control and pathogenic defense on and with-in plant tissues, however the mechanism(s) by which plants associate with PGPR to elicit such beneficial effects needs further study. Here, we present high mass resolution time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging of Brachypodium distachyon (Brachypodium) seeds with and without exposure to two model PGPR, i.e., Gram-negative Pseudomonas fluorescens SBW25::GFP (P.) and Gram-positive Arthrobacter chlorophenolicus A6::GFP (A.). Delayed image extraction was used to image PGPB-treated seed sections to reveal morphological changes. ToF-SIMS spectral compari-son, principal component analysis (PCA), and two-dimensional (2D) imaging show that the selected PGPR have different effects on the host seed surface, resulting in changes in chemical composition and morphology. Metabolite prod-ucts and biomarkers, such as flavonoids, phenolic com-pounds, fatty acids, and indole-3-acetic acid (IAA), were ob-served on the PGPR-treated seed surfaces. These compounds had different distributions on the Brachypodium seed surface for the two PGPR, indicating that the different bacteria elicited distinct responses from the host. Our results illustrate that ToF-SIMS is an effective tool to study plant-microbe interac-tions and to provide insightful information with submicrome-ter lateral resolution of the chemical distributions associated with morphological features, potentially offering a new way to study the mechanisms underlying beneficial roles of PGPR.