Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lung function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Linear operating region in the ozone dial photon counting system

Ozone is a relatively unstable molecule found in Earth's atmosphere. An ozone molecule is made up of three atoms of oxygen. Depending on where ozone resides, it can protect or harm life on Earth. High in the atmosphere, about 15 miles up, ozone acts as a shield to protect Earth's surface from the sun's harmful ultraviolet radiation. Without this shield, we would be more susceptible to skin cancer, cataracts, and impaired immune systems. Closer to Earth, in the air we breathe, ozone is a harmful pollutant that causes damage to lung tissue and plants. Since the early 1980's, airborne lidar systems have been used for making measurements of ozone. The differential absorption lidar (DIAL) technique is used in the remote measurement of O3. This system allows the O3 to be measured as function of the range in the atmosphere. Two frequency-doubled Nd:YAG lasers are used to pump tunable dye lasers. The lasers are operating at 289 nm for the DIAL on-line wavelength of O3, and the other one is operated at 300 nm for the off-line wavelength. The DIAL wavelengths are produced in sequential laser pulses with a time separation of 300 micro s. The backscattered laser energy is collected by telescopes and measured using photon counting systems. The photon counting system measures the light signal by making use of the photon nature of light. The output pulse from the Photo-Multiplier Tube (PE), caused by a photon striking the PMT photo-cathode, is amplified and passed to a pulse height discriminator. The peak value of the pulse is compared to a reference voltage (discrimination level). If the pulse amplitude exceeds the discrimination level, the discriminator generates a standard pulse which is counted by the digital counter. Non-linearity in the system is caused by the overlapping of pulses and the finite response time of the electronics. At low count rates one expects the system to register one event for each output pulse from the PMT corresponding to a photon incident upon the photocathode, however, at higher rates the limitations of the discrimination/counting system will cause the observed count rate to be non-linear with respect to the true count rate. Depending on the pulse height distribution and the discriminator level, the overlapping of pulses (pulse pile-up) can cause count loss or even an additional apparent count gain as the signal levels increase. Characterization of the system, including the pulse height distribution, the signal to noise ratio, and the effect of the discriminator threshold level, is critical in maximizing the linear operating region of the system, thus greatly increasing the useful dynamic range of the system.

Andrawis, Madeleine↗

Structural Model Tuning Capability in an Object-Oriented Multidisciplinary Design, Analysis, and Optimization Tool

Updating the finite element model using measured data is a challenging problem in the area of structural dynamics. The model updating process requires not only satisfactory correlations between analytical and experimental results, but also the retention of dynamic properties of structures. Accurate rigid body dynamics are important for flight control system design and aeroelastic trim analysis. Minimizing the difference between analytical and experimental results is a type of optimization problem. In this research, a multidisciplinary design, analysis, and optimization [MDAO] tool is introduced to optimize the objective function and constraints such that the mass properties, the natural frequencies, and the mode shapes are matched to the target data as well as the mass matrix being orthogonalized.

Lung, Shun-fat↗

Structural Model Tuning Capability in an Object-Oriented Multidisciplinary Design, Analysis, and Optimization Tool

Updating the finite element model using measured data is a challenging problem in the area of structural dynamics. The model updating process requires not only satisfactory correlations between analytical and experimental results, but also the retention of dynamic properties of structures. Accurate rigid body dynamics are important for flight control system design and aeroelastic trim analysis. Minimizing the difference between analytical and experimental results is a type of optimization problem. In this research, a multidisciplinary design, analysis, and optimization (MDAO) tool is introduced to optimize the objective function and constraints such that the mass properties, the natural frequencies, and the mode shapes are matched to the target data as well as the mass matrix being orthogonalized.

Lung, Shun-fat↗

Risk cross sections and their application to risk estimation in the galactic cosmic-ray environment

Radiation risk cross sections (i.e. risks per particle fluence) are discussed in the context of estimating the risk of radiation-induced cancer on long-term space flights from the galactic cosmic radiation outside the confines of the earth's magnetic field. Such quantities are useful for handling effects not seen after low-LET radiation. Since appropriate cross-section functions for cancer induction for each particle species are not yet available, the conventional quality factor is used as an approximation to obtain numerical results for risks of excess cancer mortality. Risks are obtained for seven of the most radiosensitive organs as determined by the ICRP [stomach, colon, lung, bone marrow (BFO), bladder, esophagus and breast], beneath 10 g/cm2 aluminum shielding at solar minimum. Spectra are obtained for excess relative risk for each cancer per LET interval by calculating the average fluence-LET spectrum for the organ and converting to risk by multiplying by a factor proportional to R gamma L Q(L) before integrating over L, the unrestricted LET. Here R gamma is the risk coefficient for low-LET radiation (excess relative mortality per Sv) for the particular organ in question. The total risks of excess cancer mortality obtained are 1.3 and 1.1% to female and male crew, respectively, for a 1-year exposure at solar minimum. Uncertainties in these values are estimated to range between factors of 4 and 15 and are dominated by the biological uncertainties in the risk coefficients for low-LET radiation and in the LET (or energy) dependence of the risk cross sections (as approximated by the quality factor). The direct substitution of appropriate risk cross sections will eventually circumvent entirely the need to calculate, measure or use absorbed dose, equivalent dose and quality factor for such a high-energy charged-particle environment.

NASA Discipline Radiation Health↗

Curvilinear Displacement Transfer Functions for Deformed Shape Predictions of Curved Structures Using Distributed Surface Strains

Curvilinear Displacement Transfer Functions were formulated for deformed shape predictions of different curved structures using surface strains. The embedded curved beam (depth-wise cross section of a curved structure along a surface strain-sensing line) was discretized into multiple small domains, with domain junctures matching the strain-sensing stations. Thus, the surface strain distribution can be described with a piecewise linear or a piecewise nonlinear function. The discrete approach enabled piecewise integrations of a curvature-strain differential equation for the embedded curved beam to yield closed-form Curvilinear Displacement Transfer Functions, which are written in terms of embedded curved-beam geometrical parameters and surface strains. By inputting the surface strain data, the Curvilinear Displacement Transfer Functions can transform surface strains into deflections along each embedded curved beam for mapping out the overall structural deformed shapes. The finite-element method was used to analytically generate the surface strains of the curved beams. The deformed shape prediction accuracies were then determined by comparing the theoretical deflections with the finite-element-generated deflections, which were used as yardsticks. By introducing the correction factors in simple mathematical forms, the Curvilinear Displacement Transfer Functions can be quite accurate for shape predictions of different curved-beam structures ranging from limit case of straight beam up to semicircular curved beam.

Ko, William L.↗

Effect of microgravity and hypergravity on deposition of 0.5- to 3-micron-diameter aerosol in the human lung

We measured intrapulmonary deposition of 0. 5-, 1-, 2-, and 3-micron-diameter particles in four subjects on the ground (1 G) and during parabolic flights both in microgravity (microG) and at approximately 1.6 G. Subjects breathed aerosols at a constant flow rate (0.4 l/s) and tidal volume (0.75 liter). At 1 G and approximately 1.6 G, deposition increased with increasing particle size. In microG, differences in deposition as a function of particle size were almost abolished. Deposition was a nearly linear function of the G level for 2- and 3-micron-diameter particles, whereas for 0.5- and 1.0-micron-diameter particles, deposition increased less between microG and 1 G than between 1 G and approximately 1.6 G. Comparison with numerical predictions showed good agreement for 1-, 2-, and 3-micron-diameter particles at 1 and approximately 1.6 G, whereas the model consistently underestimated deposition in microG. The higher deposition observed in microG compared with model predictions might be explained by a larger deposition by diffusion because of a higher alveolar concentration of aerosol in microG and to the nonreversibility of the flow, causing additional mixing of the aerosols.

Flight Experiment↗

A Solid-State Compressor for Integration of CO2 Removal and Reduction Assemblies

Integration of CO2 removal and reduction assemblies in a spacecraft air revitalization system requires an interface with the functionality of a vacuum pump/compressor and a buffer tank. The compressor must meet the vacuum needs of the CO2 removal unit and the pressure needs of the CO2 reduction device, and must also store sufficient CO2 to accommodate the differences in cycle times of the two processes. In this presentation, we describe the design and operation of an adsorption-based device sized for use on the International Space Station. The adsorption compressor functions at a power level approximately ten times lower than a comparable mechanical compression/buffer tank system. The unit is also smaller, lighter, and quieter than its mechanical counterpart.

Mulloth, Lila M.↗

Cardiopulmonary adaptation to weightlessness

The lung is profoundly affected by gravity. The absence of gravity (microgravity) removes the mechanical stresses acting on the lung paranchyma itself, resulting in a reduction in the deformation of the lung due to its own weight, and consequently altering the distribution of fresh gas ventilation within the lung. There are also changes in the mechanical forces acting on the rib cage and abdomen, which alters the manner in which the lung expands. The other way in which microgravity affects the lung is through the removal of the gravitationally induced hydrostatic gradients in vascular pressures, both within the lung itself, and within the entire body. The abolition of a pressure gradient within the pulmonary circulation would be expected to result in a greater degree of uniformity of blood flow within the lung, while the removal of the hydrostatic gradient within the body should result in an increase in venous return and intra-thoracic blood volume, with attendant changes in cardiac output, stroke volume, and pulmonary diffusing capacity. During the 9 day flight of Spacelab Life Sciences-1 (SLS-1) we collected pulmonary function test data on the crew of the mission. We compared the results obtained in microgravity with those obtained on the ground in both the standing and supine positions, preflight and in the week immediately following the mission. A number of the tests in the package were aimed at studying the anticipated changes in cardiopulmonary function, and we report those in this communication.

short duration↗

Studies of the effects of gravitational and inertial forces on cardiovascular and respiratory dynamics

The current status and application are described of the biplane video roentgen densitometry, videometry and video digitization systems. These techniques were developed, and continue to be developed for studies of the effects of gravitational and inertial forces on cardiovascular and respiratory dynamics in intact animals and man. Progress is reported in the field of lung dynamics and three-dimensional reconstruction of the dynamic thoracic contents from roentgen video images. It is anticipated that these data will provide added insight into the role of shape and internal spatial relationships (which is altered particularly by acceleration and position of the body) of these organs as an indication of their functional status.

Ritman, E. L.↗

The response of single human cells to zero gravity

The SO15 experiment was designed to extend observations of the effects of zero-gravity to living human cells during and subsequent to a 59-day flight on Skylab 3. A strain of diploid human embryonic lung cells, WI-38, was chosen for this purpose. The studies were concerned with observations designed to detect the effects of zero-gravity on cell growth rates and on cell structure as observed by light microscopy, transmission and scanning electron microscopy and histochemistry. Studies of the effects of zero-gravity on the cell function and the cell cycle were performed by time lapse motion picture photography and microspectrophotometry. Subsequent study of the returned living cells included karotyping, G- and C-banding, and analyses of the culture media used. Some of the living cells returned were banked by deep freeze techniques for possible future experiments.

Montgomery, P. O., Jr.↗

Effect of water immersion on cardiopulmonary physiology at high gravity (+Gz)

The cardiopulmonary responses of eight male subject between 21-31 years exposed to 1, 2, and 3 Gz during immersion at 35 + or - 0.5 C to heart level and during control dry rides are studied. Ventilation, O2 consumption, the end-tidal pressure of CO2, heart frequency, cardiac output, functional residual capacity, and the arterial pressure of CO2 were measured. It is observed that as Gz increases ventilation, heart frequency, and O2 consumption increase, and the end-tidal and arterial pressures of CO2 decrease during dry rides, but are not altered during immersion. It is detected that the functional residual capacity is lower during immersion and decreases in both the dry and immersed state as Gz increases, and cardiac output decreases as Gz increases in dry rides. It is noted that changes produced by acceleration in a Gz direction are due to the effect on the systemic circulation rather than to the effect on the lungs.

Arieli, R.↗

Two-stage model of radon-induced malignant lung tumors in rats: effects of cell killing

A two-stage stochastic model of carcinogenesis is used to analyze lung tumor incidence in 3750 rats exposed to varying regimens of radon carried on a constant-concentration uranium ore dust aerosol. New to this analysis is the parameterization of the model such that cell killing by the alpha particles could be included. The model contains parameters characterizing the rate of the first mutation, the net proliferation rate of initiated cells, the ratio of the rates of cell loss (cell killing plus differentiation) and cell division, and the lag time between the appearance of the first malignant cell and the tumor. Data analysis was by standard maximum likelihood estimation techniques. Results indicate that the rate of the first mutation is dependent on radon and consistent with in vitro rates measured experimentally, and that the rate of the second mutation is not dependent on radon. An initial sharp rise in the net proliferation rate of initiated cell was found with increasing exposure rate (denoted model I), which leads to an unrealistically high cell-killing coefficient. A second model (model II) was studied, in which the initial rise was attributed to promotion via a step function, implying that it is due not to radon but to the uranium ore dust. This model resulted in values for the cell-killing coefficient consistent with those found for in vitro cells. An "inverse dose-rate" effect is seen, i.e. an increase in the lifetime probability of tumor with a decrease in exposure rate. This is attributed in large part to promotion of intermediate lesions. Since model II is preferable on biological grounds (it yields a plausible cell-killing coefficient), such as uranium ore dust. This analysis presents evidence that a two-stage model describes the data adequately and generates hypotheses regarding the mechanism of radon-induced carcinogenesis.

NASA Program Radiation Health↗

Thermal degradation events as health hazards - Particle vs gas phase effects, mechanistic studies with particles

Experiments on animal subjects are performed to demonstrate that significant lung injury can result from the inhalation of ultrafine TiO2 or Al2O3 particles. The methods include intratracheal instillation of particles, long-term inhalation of particles, and in vitro studies of alveolar macrophages (AMs) to study the production of fibroplast growth factors. The ultrafine TiO2 particles are shown to induce more acute inflammatory reactions than larger particles and lead to persistent chronic effects in the AM-mediated clearance function of particles. The ultrafine particles also induce cytokines more readily, and the data generally suggests that the occurrence of such particles in thermal degradation events makes the fumes highly toxic. The exposure to thermal degradation products is therefore a critical concern for manned space missions with potentially degradable plastic products.

Oberdoerster, G.↗

Distribution of pulmonary ventilation and perfusion during short periods of weightlessness

Airborne experiments were conducted on four trained normal male subjects (28-40 yr) to study pulmonary function during short periods (22-27 sec) of zero gravity obtained by flying a jet aircraft through appropriate parabolic trajectories. The cabin was always pressurized to a sea-level altitude. The discussion is limited to pulmonary ventilation and perfusion. The results clearly demonstrate that gravity is the major factor causing nonuniformity in the topographical distribution of pulmonary ventilation. More importantly, the results suggest that virtually all the topographical nonuniformity of ventilation, blood flow, and lung volume observed under 1-G conditions are eliminated during short periods of zero gravity.

Michels, D. B.↗

Mode shift of an inhaled aerosol bolus is correlated with flow sequencing in the human lung

We studied the effects on aerosol bolus inhalations of small changes in convective inhomogeneity induced by posture change from upright to supine in nine normal subjects. Vital capacity single-breath nitrogen washout tests were used to determine ventilatory inhomogeneity change between postures. Relative to upright, supine phase III slope was increased 33 +/- 11% (mean +/- SE, P < 0.05) and phase IV height increased 25 +/- 11% (P < 0.05), consistent with an increase in convective inhomogeneity likely due to increases in flow sequencing. Subjects also performed 0.5-microm-particle bolus inhalations to penetration volumes (V(p)) between 150 and 1,200 ml during a standardized inhalation from residual volume to 1 liter above upright functional residual capacity. Mode shift (MS) in supine posture was more mouthward than upright at all V(p), changing by 11.6 ml at V(p) = 150 ml (P < 0.05) and 38.4 ml at V(p) = 1,200 ml (P < 0.05). MS and phase III slope changes correlated positively at deeper V(p). Deposition did not change at any V(p), suggesting that deposition did not cause the MS change. We propose that the MS change results from increased sequencing in supine vs. upright posture.

NASA Discipline Cardiopulmonary↗

Anti-Icing Formulas Prevent Train Delays

In the winter of 2009, Washington, DC, workers faced the prospect of a difficult commute due to record-setting snowfalls. But thousands of the city's Metrorail riders found the public transportation system fully functional, thanks in part to a NASA technology invented years before. Just like trains, an airplane must be snow- and ice-free to ensure safe travel. Traditionally, fluids containing a compound called ethylene glycol have been used to inhibit ice on planes. In 1992, however, the US Air Force banned its purchase of this ingredient due to toxicity concerns. According to the Centers for Disease Control, exposure to large amounts of ethylene glycol through air or water can damage the kidneys, nervous system, lungs, and heart. Urine samples from airport deicing workers have contained traces of the substance. At the time of the Air Force s ban, Robert Lockyer was working at NASA s Ames Research Center in the Advanced Composites Model Development Branch, where he says "we decided to pick up the gauntlet and began researching existing fluid compositions and the processes used in deicing aircraft." Along with Lockyer, in 1997 Ames researchers Leonard Haslim and John Zuk devised a nontoxic, biodegradable, and cost effective substitute for ethylene glycol. When applied to a dry surface before a snow or ice event, the solution prevented ice from forming a bond with the surface. This made it easy to wipe away any accumulation.

Source record↗

Three-dimensional reconstruction and display of the heart, lungs and circulation by multiplanar X-ray scanning videodensitometry

A device was developed which makes possible the dynamic reconstruction of the heart and lungs within the intact thorax of a living dog or human and which can record approximately 30 multiplanar X-ray images of the thorax practically instantaneously, and at frequent enough intervals of time and with sufficient density and spatial resolution to capture and resolve the most rapid changes in cardiac structural detail throughout each cardiac cycle. It can be installed in a clinical diagnostic setting as well as in a research environment and its construction and application for determination and display in real-time modes of cross sections of the functioning thorax and its contents of living animals and man is technologically feasible.

Robb, R. A.↗