Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High finesse buckled microcavities

Optical cavities are widely used in modern science and technology to enable a wide range of both quantum and classical applications. Recently, the growing demand for miniaturization and high performance has fueled the exploration of new fabrication methods beyond traditional polishing techniques and macroscopic mirrors. Visible and near-infrared (NIR) wavelengths are particularly important for quantum applications, where achieving low-loss resonators is also more challenging than in the telecom range, presenting unique challenges and opportunities for microscopic cavity systems. Here, we present a fabrication method for making NIR microcavities using buckled dielectric membrane mirrors, achieving a record finesse of 0.9 million at 780 nm for microcavities. We demonstrated flexible device geometries—including singular mirrors and mirror arrays, featuring radii of curvature ranging from 1 to 10 mm. The fabrication process offers high uniformity, high yield, and robust performance across a wide range of cavity lengths. Additionally, we can produce easy-to-assemble microcavity packages, with a total volume of ~2(4) mm 3 , featuring optical modes with a linewidth of 5.16 MHz (570 kHz) and a free spectral range (FSR) of 3.18 THz (150 GHz). Our results extend the frontier of microcavity fabrication for classical and quantum photonic technologies.

Ding, Sophie Weiyi [Harvard Univ., Cambridge, MA (↗

Triangular cross-section beam splitters in silicon carbide for quantum information processing

Abstract Triangular cross-section color center photonics in silicon carbide is a leading candidate for scalable implementation of quantum hardware. Within this geometry, we model low-loss beam splitters for applications in key quantum optical operations such as entanglement and single-photon interferometry. We consider triangular cross-section single-mode waveguides for the design of a directional coupler. We optimize parameters for a 50:50 beam splitter. Finally, we test the experimental feasibility of the designs by fabricating triangular waveguides in an ion beam etching process and identify suitable designs for short-term implementation.

42 ENGINEERING↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Photon Detector & Counter for Transduction

Over the recent years, quantum computers have procured the attention of the public, largely due to their fast factoring capabilities and potential for efficient simulation of quantum dynamics \cite{RevModPhys.79.135}. This interest, coupled with advances in quantum transduction, could lead to the realization of a quantum distributed network, effectively linking dilution fridges across vast distances. Presently, there are several qubit systems developed for encoding quantum information. They primarily fall into two categories: those exploiting optical frequencies for excitation, and those operating at microwave frequencies. Optical frequency qubit systems include trapped ions, neutral atoms, quantum dots, and solid-state defects. Microwave frequency qubit system encompass superconducting qubits (transmon) and spins in crystals. Among these, transmons are particularly intriguing due to their low-loss of photons at microwave frequencies. The Josephson effect within a superconducting circuit enables high-fidelity quantum operations \cite{Microwave-optical_quantum_frequency_conversion}. Thus, it is non-trivial to develop an apparatus for efficiently bridging microwave and optical frequency regimes.

Bautista-Cortezano, Pablo↗

SIMS CHARACTERIZATION OF NITROGEN DOPING OF LCLS-II-HE PRODUCTION CAVITIES

The thermal diffusion of nitrogen into the surface of niobium has been shown to yield superior low-loss SRF performance. An effective solution was identified and promptly employed in the production of cryomodules for LCLS-II. With added experience and R&D, a modified process was chosen for use in the upgrade for LCLS-II-HE. Largely motivated by this circumstance, supporting research has significantly refined the technique for making calibrated secondary ion mass spectrometry (SIMS) measurements of the N concentration depth profiles produced by production processes. Standardized reference samples were included with four HE production cavities in their N-doping furnace runs. We report the calibrated dynamic SIMS depth profiles of N, C, and O for these samples, together with the cryogenic acceptance test performance of the associated cavities. Interpretation and comparison with similar samples acquired in other furnaces highlights the importance of intentional process quality control of furnace conditions.

Reece, Charles↗

Bottom-Up Soft Magnetic Composites (FY 2022 Annual Progress Report)

The project objective is to develop high-magnetization, low-loss iron nitride based soft magnetic composites for electrical machines. These new SMCs will enable low eddy current losses and therefore highly efficient motor operation at rotational speeds up to 20,000 rpm. Additionally, iron nitride and epoxy composites will be capable of operating at temperatures of 150 °C or greater over a lifetime of 300,000 miles or 15 years.

36 MATERIALS SCIENCE↗

Material and Interface Engineering Strategies to Mitigate Decoherence in Superconducting Qubits

While significant strides have been made to increase the coherence time of superconducting qubits, further advancements are essential for realizing scalable quantum computing. Decoherence is often a result of loss and noise stemming from two-level systems and excess quasiparticles, arising due to material defects, fabrication processes, and ambient exposure, particularly at surfaces and interfaces. Our recent efforts to mitigate these decoherence mechanisms have employed a variety of strategies, including low-loss surface encapsulation materials, advanced substrate preparation techniques, modifications to metal film growth, and the development of novel fabrication processes. The structural and chemical properties of materials, surfaces, and interfaces are studied using scanning probe microscopy, electron microscopy, photoelectron spectroscopy, mass spectrometry, and X-ray diffraction, which is correlated to device performance metrics, including superconducting resonator internal quality factor and qubit T1 time. This information is used to identify and understand material sources of loss and their origins in the device fabrication process. Through multi-institution efforts within SQMS we have identified the loss mechanism of interstitial hydrogen in niobium-based devices and shown how standard fabrication processes introduce these hydrides, developing strategies to mitigate their formation.1 Furthermore, we have characterized the metal-substrate interface, including the loss of niobium-silicides formed at that interface, and developed silicon surface treatments that reduce atomic scale roughness and oxygen content at the metal-substrate and Josephson junction interfaces.2-4 By developing the connection between materials properties and the overall performance of superconducting quantum circuitry, we can develop fabrication strategies to mitigate material losses, thus supporting the ongoing efforts to enhance coherence time in superconducting quantum devices. 1. Torres-Castanedo, C. G.*, Goronzy, D. P.*, et al., Adv. Funct. Mater., 2401365 (2024) 2. Lu, X., et al., Phys. Rev. Materials 6, 064402 (2022) 3. Berti, G., Appl. Phys. Lett. 122, 192605 (2023) 4. Kopas, C. J., Goronzy, D. P., et al., arXiv:2408.02863 (2024)

Goronzy, Dominic P.↗

Efficient Reversible Operation and Stability of Novel Solid Oxide Cells

This project aims to develop and test novel Reversible Solid Oxide Cells (ReSOCs) specifically designed to yield low area specific resistance, as required to achieve high round trip efficiency in reversible operation at high current density. A key objective is to improve long-term reversible SOC durability; mechanistic degradation models will be used to predict long-term durability using input data from accelerated testing that combines electrochemical life testing with quantitative microstructural and chemical evaluation. The modeling tasks seek to design low-loss, low-cost ReSOC systems using input data from the experimental cell studies. A key challenge is to develop a thermal management strategy that maintains thermally self-sustaining operation while operating the stack at a potential lower than the thermo-neutral steam electrolysis voltage of ~1.3 V, to maintain high efficiency.

08 HYDROGEN↗

Characterizing Microwave Losses in Superconducting Coaxial Cables for Quantum Systems

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present a detailed characterization of microwave losses in commercially available superconducting cables and discuss how material characterization techniques can be useful for understanding their microscopic origin.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Investigating Low Loss Substrates for Improved Qubit Coherence Times

Superconducting qubits are sensitive to dielectric losses from substrates, making the identification, optimization, and preparation of low-loss materials essential for enhancing qubit coherence times. In this work, we utilize Nb superconducting radio-frequency (SRF) cavities as a high-precision measurement tool to study the dielectric loss tangent of substrates with parts-per-billion sensitivity. This technique enables temperature- and field-resolved measurements, providing deep insights into the behavior of candidate materials such as sapphire and silicon. We explore the impact of substrate preparation techniques, examining how surface treatments and cleaning protocols influence dielectric loss. These studies highlight both the microscopic origins of loss in these substrates and the critical role of preparation methods, helping to identify key materials and processes that minimize dielectric loss, crucial for improving qubit performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Broadband mm-Wave Substrate Integrated Waveguides [Poster]

At mm-wave frequencies, signals need to be supported by specialized, low-loss transmission lines such as waveguides. Substrate-integrated waveguides (SIWs) combine the good electrical properties of rectangular waveguides with the compactness of planar transmission lines. Additionally, SIWs can be fabricated using standard PCB manufacturing techniques and can be easily integrated with other mm-wave components. This study explores SIWs in the 50-75 GHz range, with designs optimized for simple fabrication.

42 ENGINEERING↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Optimized cryogenic setup for microwave loss characterization of superconducting coaxial cables

As superconducting quantum systems scale up to enable applications like large-scale quantum computing, challenges such as fabrication yield, wiring complexity, and microwave crosstalk drive the need for high-fidelity, low-loss, modular interconnects. In recent experiments, the performance of these interconnects is often limited by cable loss, a factor that becomes even more critical as we aim for higher fidelity operations and connect increasingly coherent modules. In this talk, we present our cryogenic microwave loss characterization setup, carefully designed to minimize losses external to the coaxial cables under test. We also share results for several commercially-available superconducting cables measured with this setup and briefly discuss our ongoing efforts to develop custom coaxial cables capable of achieving state-of-the-art performance.

Vallières, André [Northwestern U.]↗

Bottom-Up Soft Magnetic Composites

The project objective is to develop high-magnetization, low-loss iron nitride based soft magnetic composites for electrical machines. These new SMCs will enable low eddy current losses and therefore highly efficient motor operation at rotational speeds up to 20,000 rpm. Additionally, iron nitride and epoxy composites will be capable of operating at temperatures of 150 °C or greater over a lifetime of 300,000 miles or 15 years.

36 MATERIALS SCIENCE↗

Electropolishing-induced topographic defects in niobium: Insights and Implications for SRF

Electropolishing (EP) is the premier surface preparation method for high-Q, high-gradient superconducting RF cavities made of Nb. This leaves behind an apparently smooth surface, yet the achievable peak magnetic fields fall well below the superheating field of Nb, in most cases. In this work, the ultimate surface finish of EP was investigated by studying its effect on highly polished Nb samples. EP introduces high slope angle sloped-steps at grain boundaries. The magnetic field enhancement and superheating field suppression factors associated with such a geometry are calculated in the London theory. Despite the by-eye smoothness of electropolished Nb, such defects compromise the stability of the low-loss Meissner state, likely limiting the achievable peak accelerating fields in superconducting RF cavities. Finally, the impact of surface roughness on impurity diffusion is investigated which can link surface roughness to the effectiveness of heat treatments like low-temperature baking or nitrogen infusion in the vortex nucleation or hydride hypotheses. Surface roughness tends to decrease the effective dose of impurities as a result of the expansion of impurities into regions with greater internal angle. The effective dose of impurities can be protected by minimizing slope angles and step heights, ensuring uniformity.

Lechner, Eric [Thomas Jefferson National Accelerat↗

Probabilistic Mixture Model-Based Spectral Unmixing

Spectral unmixing attempts to decompose a spectral ensemble into the constituent pure spectral signatures (called endmembers) along with the proportion of each endmember. This is essential for techniques like hyperspectral imaging (HSI) used in environment monitoring, geological exploration, etc. Several spectral unmixing approaches have been proposed, many of which are connected to hyperspectral imaging. However, most extant approaches assume highly diverse collections of mixtures and extremely low-loss spectroscopic measurements. Additionally, current non-Bayesian frameworks do not incorporate the uncertainty inherent in unmixing. We propose a probabilistic inference algorithm that explicitly incorporates noise and uncertainty, enabling us to unmix endmembers in collections of mixtures with limited diversity. We use a Bayesian mixture model to jointly extract endmember spectra and mixing parameters while explicitly modeling observation noise and the resulting inference uncertainties. We obtain approximate distributions over endmember coordinates for each set of observed spectra while remaining robust to inference biases from the lack of pure observations and the presence of non-isotropic Gaussian noise. As a direct impact of our methodology, access to reliable uncertainties on the unmixing solutions would enable robust solutions to noise, as well as informed decision-making for HSI applications and other unmixing problems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗