Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low-load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

New Approaches to Improved PEM Fuel Cell Catalyst Layers

Polymer-electrolyte membrane (PEM) fuel-cells are one of the most promising energy conversion technologies for renewable clean energy applications. A major challenge preventing the widespread use and commercialization of PEM fuel cells is achieving high performance with low-loadings of platinum group metal (PGM) catalysts. One of the factors driving performance limitations in the cell is the mass transport losses within the cathode catalyst layers (CCL) due to sluggish oxygen-reduction reactions occurring at the platinum-ionomer interface. Any resistance to transport of these ionic and gaseous species within the CCL results in mass-transport limitations and performance losses, especially at high current densities. It is known that mass-transport losses increase with reduced platinum loading, thereby creating a performance-cost tradeoff for fuel cells. A viable solution to reduce the transport resistances in the catalyst layers is to create new ionomers that can provide good ion and oxygen transport needed to accomplish high-performing fuel cell catalysts. Using this approach Tetramer Technologies and LBNL propose improved fuel-cell catalyst ionomers based on Tetramers proprietary polymer chemistry.

30 DIRECT ENERGY CONVERSION↗

Tri-State/NETL/Sandia/LBNL IDAES CRADA (Final Report)

The primary goals of this work are to develop recommendations aimed at: (1) reducing the minimum load achievable by a partner plant, (2) improving reliability issues that may result from extended low-load operations, and (3) improving overall efficiency, especially at partial loads. Steady state and dynamic models will also be deployed to a partner plant.

20 FOSSIL-FUELED POWER PLANTS↗

Development of the Well-to-Wake Life Cycle Assessment Model for Marine Fuels in R&D GREET 2025

The Marine analysis capabilities in the 2025 Research and Development Greenhouse gases, Regulated Emissions, and Energy use in Technologies (R&D GREET) have been updated to incorporate the latest findings from the Fourth International Maritime Organization (IMO) GHG Study.1 To support these updates and enhance user flexibility, the former single marine module used in previous R&D GREET versions has been split into two workbook tabs: The Marine_Fuel tab, which covers the fuel-cycle, and the Marine_Trip tab, which covers the trip-cycle. In the Marine_Fuel tab, fuel cycle results for 39 marine fuels are available—assuming a slow speed diesel engine—and can be seen in Appendix A. However, there are options for changing feedstocks for multiple fuels, ability to view results with or without pilot fuels for fuels such as methanol and ammonia, and carbon capture options. All these combinations make the number of total possible pathways over one hundred. For each pathway, life cycle emission results are divided into feedstock, conversion, and combustion categories, along with pilot fuel supply chain emissions for fuels used in dual fuel engines. In the newly created Marine_Trip tab, users can view the life cycle emissions of using these fuels from a trip perspective. Compared to R&D GREET 2024, 16 new types of vessels are added in R&D GREET 2025. Examples of results assuming the default size for each vessel type are available in Appendix A. Additional information categories on vessels are included such as vessel size, main propulsion type, engine power rating, combustion cycle, etc. based on the Fourth IMO GHG Study. Operational mode of the trip, fuel consumption, and load calculation were updated based on the report. The fuel consumption calculation also incorporates low-load adjustment, speed–power correction, weather correction, and fouling correction factors. Furthermore, fuel consumption in boilers or steam turbines is also added for the first time, besides fuel use in main propulsion engines and auxiliary engines. This effort makes the R&D GREET Marine capabilities more robust than before. Users will be able to estimate fuel consumption more accurately for more diverse choices of vessel categories, vessel sizes, and energy converters.

09 BIOMASS FUELS↗

AOI 5 Improved Efficiency of Medium- and Heavy-Duty Natural Gas and Propane (LPG) Engines

Spark-ignited heavy-duty (HD) natural gas engines typically experience efficiency losses at part-load operation due to throttling requirements needed to maintain stoichiometric combustion. A substantial portion of medium- and heavy-duty engine operation occurs in this low-load region, resulting in increased brake-specific carbon dioxide emissions and reduced overall efficiency. This project designed, developed and demonstrated cylinder deactivation (CDA) technology on an HD natural gas engine to mitigate these losses. CDA enables selective deactivation of cylinders, reducing pumping losses while maintaining required torque output and meeting vehicle noise, vibration, and harshness (NVH) targets. The project objectives were successfully achieved, demonstrating up to 12% improvement in fuel consumption over the next generation HD NG engine on key low loaded HD cycles and maintained compliance with 0.02 g/hp-hr NO x emissions with comparable or better vibrations to current product. These results confirm that CDA technology can substantially improve the fuel efficiency and environmental performance of heavy-duty natural gas engines, reinforcing their potential as a low-carbon bridge solution in the transition toward zero-emission transportation technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a Dynamic Model and Control System for Load-Following Studies of Supercritical Pulverized Coal Power Plants

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.

20 FOSSIL-FUELED POWER PLANTS↗

Effects of truncation of a predominantly compression load spectrum on the life of a notched graphite/epoxy laminate

The fatigue behavior of a notched, graphite/epoxy (T300/5208) laminate subjected to predominantly compressive loading was explored in a series of constant-amplitude and transport wing spectrum tests. Results of these tests indicate that (1) the amount of local (near the notch) buckling allowed in the tests significantly affected fatigue life; (2) spectrum truncation of either the high- or low-load end of the spectrum produced lives greater than those obtained in the baseline, complete-spectrum test, but life was much more sensitive to truncations at the high-load end; and (3) the Palmgren-Miner linear cumulative damage theory always predicted lives much longer than the actual spectrum loading test lives.

Phillips, E. P.↗

Thermal vacuum testing of flexible radiator systems

Flexible fin radiators are being developed to meet spacecraft requirements of light weight, compact launch volume, modular growth, reusability, and the capability of an on-orbit deployment and retraction. Two prototype versions of deployable/retractable, flexible finspace radiators (soft and hard tube) were tested simultaneously under thermal vacuum conditions. A map of the heat rejection performance of each radiator panel under various environmental conditions is given. The soft tube radiator deployment system demonstrated minimal gas pressure and was capable of maintaining partial deployment; temperature control was achieved by varying the deployment length. The radiator could be recovered after an inadvertant freezing of the coolant in the Teflon tube. The hard tube radiator deployment mechanism performed adequately throughout the testing, but did exhibit some undesirable performance characteristics. The hard tube radiator pressure drop was higher than expected, but was not affected by the length of deployment. The radiator operated at less than full deployment, and the manifolds were found to have a significant effect on heat rejection. At low-load conditions, the hard tube radiator appeared to bypass its deployed area.

Rankin, G.↗

Economy of precipitating agent application in municipal wastewater treatment facilities

Purification by precipitation in this study is not considered primarily as a means of phosphate removal but as a method for reduction of suspended solids BOD and COD. A dynamic calculation procedure is used to allow for exact determination of time dependent variation of costs. The results show that costs of wastewater treatment by precipitation may equal those of conventional primary clarification and secondary biological treatment, especially with low-cost iron-II-salts in simultaneous precipitation and in larger plants ( 20,000 PF). Cost advantages may be accrued in smaller plants by using the more expensive trivalent salts in pre-precipitation as compared to conventional low-load biological treatment. This is due mainly to better effluent quality and, consequently, lower wastewater fees (Wastewater Discharge Act). If the precipitant is dosed temporarily only during periods of highest pollution the savings can be about 5 to 10%.

Neis, U.↗

Full scale phosphoric acid fuel cell stack technology development

The technology development for phosphoric acid fuel cells is summarized. The preparation, heat treatment, and characterization of carbon composites used as bipolar separator plates are described. Characterization included resistivity, porosity, and electrochemical corrosion. High density glassy carbon/graphite composites performed well in long-term fuel cell endurance tests. Platinum alloy cathode catalysts and low-loaded platinum electrodes were evaluated in 25 sq cm cells. Although the alloys displayed an initial improvement, some of this improvement diminished after a few thousand hours of testing. Low platinum loading (0.12 mg/sq cm anodes and 0.3 mg/sq cm cathodes) performed nearly as well as twice this loading. A selectively wetproofed anode backing paper was tested in a 5 by 15 inch three-cell stack. This material may provide for acid volume expansion, acid storage, and acid lateral distribution.

Christner, L.↗

Indentation fracture toughness of sintered silicon carbide in the Palmqvist crack regime

The fracture toughness of a sintered dense alpha-SiC was estimated by the Vickers indentation microfracture method in the low-load Palmqvist crack regime. It was observed that the use of simultaneously obtained Vickers hardnesses does not yield reliable fracture toughness values, nor does application of the median-crack-derived equations. It is necessary to utilize a load-independent, crack-free hardness value with this toughness estimation method. Although several of the curve-fitting equations yield similar toughnesses, it is concluded for the Palmqvist crack system in this alpha-SiC that the Niihara-Morena-Hasselman (1982) equation is the only one which yields fracture toughness values in agreement with conventional measurement techniques.

Li, Zhuang↗

Non-Coalescence in Microgravity: Science and Technology

In this project we examine non-coalescence and non-wetting phenomena driven by either thermocapillary convection or forced motion of one surface relative to the other. In both cases, the non-coalescence or non-wetting is enabled by the existence of a lubricating layer of gas that exists to keep the two surfaces in question from coming into contact with one another. Recent progress has been made on several fronts: 1) measurement of the vibrational modes of pinned droplets; 2) development of an apparatus for the measurement of the frictional forces associated with a non-wetting droplet sliding over a solid surface; 3) measurements of the failure modes for non-wetting droplets and the influence of static electric charge on failure-, and 4) numerical simulation of a two-dimensional non-wetting droplet revealing a possible explanation for why the phenomenon has not been able to be observed using water as the droplet liquid. Issue 1) above is of relevance to the use of non-wetting droplets as positioning mechanisms and vibration dampers in a microgravity environment; issue 2) relates to the use of non-wetting droplets as nearly 'frictionless' bearings in low-load applications. Understanding of the failure modes identified in 3) is of importance to any potential application and the numerical simulations conducted under 4) allow us to obtain information about these systems that is currently not available through experimentation Each of these topics will be discussed briefly during the presentation.

Neitzel, G. Paul↗

Hindlimb unloading alters ligament healing

We investigated the hypothesis that hindlimb unloading inhibits healing in fibrous connective tissue such as ligament. Male rats were assigned to 3- and 7-wk treatment groups with three subgroups each: sham control, ambulatory healing, and hindlimb-suspended healing. Ambulatory and suspended animals underwent surgical rupture of their medial collateral ligaments, whereas sham surgeries were performed on control animals. After 3 or 7 wk, mechanical and/or morphological properties were measured in ligament, muscle, and bone. During mechanical testing, most suspended ligaments failed in the scar region, indicating the greatest impairment was to ligament and not to bone-ligament insertion. Ligament testing revealed significant reductions in maximum force, ultimate stress, elastic modulus, and low-load properties in suspended animals. In addition, femoral mineral density, femoral strength, gastrocnemius mass, and tibialis anterior mass were significantly reduced. Microscopy revealed abnormal scar formation and cell distribution in suspended ligaments with extracellular matrix discontinuities and voids between misaligned, but well-formed, collagen fiber bundles. Hence, stress levels from ambulation appear unnecessary for formation of fiber bundles yet required for collagen to form structurally competent continuous fibers. Results support our hypothesis that hindlimb unloading impairs healing of fibrous connective tissue. In addition, this study provides compelling morphological evidence explaining the altered structure-function relationship in load-deprived healing connective tissue.

NASA Discipline Musculoskeletal↗

BASS Code Development

The BASS computational aeroacoustic code solves the fully nonlinear Euler equations in the time domain in two-dimensions. The acoustic response of the stator is determined simultaneously for the first three harmonics of the convected vortical gust of the rotor. The spatial mode generation, propagation and decay characteristics are predicted by assuming the acoustic field away from the stator can be represented as a uniform flow with small harmonic perturbations superimposed. The computed field is then decomposed using a joint temporal-spatial transform to determine the wave amplitudes as a function of rotor harmonic and spatial mode order. This report details the following technical aspects of the computations and analysis. 1) the BASS computational technique; 2) the application of periodic time shifted boundary conditions; 3) the linear theory aspects unique to rotor-stator interactions; and 4) the joint spatial-temporal transform. The computational results presented herein are twofold. In each case, the acoustic response of the stator is determined simultaneously for the first three harmonics of the convected vortical gust of the rotor. The fan under consideration here like modern fans is cut-off at +, and propagating acoustic waves are only expected at 2BPF and 3BPF. In the first case, the computations showed excellent agreement with linear theory predictions. The frequency and spatial mode order of acoustic field was computed and found consistent with linear theory. Further, the propagation of the generated modes was also correctly predicted. The upstream going waves propagated from the domain without reflection from the in ow boundary. However, reflections from the out ow boundary were noticed. The amplitude of the reflected wave was approximately 5% of the incident wave. The second set of computations were used to determine the influence of steady loading on the generated noise. Toward this end, the acoustic response was determined with three steady loading conditions: design, low-loading, high-loading. The overall trend showed significant (approximately 10 dB) increases in the generated noise for the highly loaded stator.

Sawyer, Scott↗

Large-Strain Transparent Magnetoactive Polymer Nanocomposites

A document discusses polymer nano - composite superparamagnetic actuators that were prepared by the addition of organically modified superparamagnetic nanoparticles to the polymer matrix. The nanocomposite films exhibited large deformations under a magnetostatic field with a low loading level of 0.1 wt% in a thermoplastic polyurethane elastomer (TPU) matrix. The maximum actuation deformation of the nanocomposite films increased exponentially with increasing nanoparticle concentration. The cyclic deformation actuation of a high-loading magnetic nanocomposite film was examined in a low magnetic field, and it exhibited excellent reproducibility and controllability. Low-loading TPU nanocomposite films (0.1-2 wt%) were transparent to semitransparent in the visible wavelength range, owing to good dispersion of the magnetic nanoparticles. Magnetoactuation phenomena were also demonstrated in a high-modulus, high-temperature polyimide resin with less mechanical deformation.

Meador, Michael A.↗

Relocatable 10 kW Solar Array for Lunar South Pole Missions

Deployable, relocatable, free-standing solar arrays are being developed to provide modular power for future lunar South Pole missions. Major design requirements for these arrays will be low mass, compact launch stowage, and highly reliable deployment and retraction. This paper presents a novel conceptual design for a10 kW solar array to address these requirements referred to as the Relocatable Solar Array (RSA).Simply stated, the concept is a pair of solar cell blankets freely hanging from a horizontal cross arm supported by a vertical, slender, telescoping mast resting on a deployable tripod base. A major factor in simplifying the design is that the force exerted by lunar gravity is used to deploy and maintain extension of the hanging array blankets. A second major factor in achieving the desired low mass and high volumetric efficiency is that the array operates in the vacuum, low-gravity, lunar environment with no deployed vibration frequency requirement. Such a low-load environment enables use of extraordinarily slender and low mass structural members to support the hanging array blankets. This concept was developed, in part, to serve as a NASA reference solar array concept against which other proposed arrays can be compared.

Lunar Surface Power↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: High-Velocity Small-Diameter Duct System, Pittsburgh, Pennsylvania

This study tests the performance of a variable airflow small-diameter duct heating, ventilation, and air conditioning (HVAC) system in a new construction unoccupied low-load test house in Pittsburgh, Pennsylvania. The duct system was installed entirely in conditioned space and was operated from the winter through summer seasons. Measurements were collected on the in-room temperatures and energy consumed by the air handler and heat pump unit. Operation modes with three different volumes of airflow were compared to determine the ideal airflow scenario that maximizes room-to-room thermal uniformity while minimizing fan energy consumption. Black felt infrared imagery was used as a measure of diffuser throw and in-room air mixing. Measured results indicate the small-diameter, high velocity airflow system can provide comfort under some conditions. Solar heat gains resulted in southern rooms drifting beyond acceptable temperature limits. Insufficient airflow to some bedrooms also resulted in periods of potential discomfort. Homebuilders or HVAC contractors can use these results to assess whether this space conditioning strategy is an attractive alternative to a traditional duct system. The team performed a cost analysis of two duct system configurations: (1) a conventional diameter and velocity duct system, and (2) the small-diameter duct system. This work applies to both new and retrofit homes that have achieved a low heating and cooling density either by energy conservation or by operation in a mild climate with few heating or cooling degree days. Guidance is provided on cost trade-offs between the conventional duct system and the small-diameter duct system.

Building America↗

Improving Flexibility and Performance of Staged Pressurized Oxy-Combustion

Staged pressurized oxy-combustion (SPOC) is a novel coal combustion power technology being developed by Washington University in St. Louis (WUSTL) that offers the potential to deliver low-carbon power at a reduced cost. Oxy-combustion plants operate by removing most of the nitrogen contained in air prior to combustion, thereby burning fuel in a near-pure oxygen stream instead of air. This combustion produces a flue gas containing primarily carbon dioxide (CO 2 ) and water vapor that allows relatively straightforward CO 2 capture. First-generation, atmospheric oxy-combustion technology relies on a flue gas recycle (FGR) diluent to reduce the peak temperatures achieved and the resulting high thermal radiation levels that would otherwise occur in a fuel/oxygen only flame. In contrast, by staging the combustion in several steps, SPOC reduces the peak temperatures of combustion without resorting to a high degree of FGR to control flame temperatures. The SPOC process operates by utilizing two or more pressurized boiler modules connected in series to produce fuel staging; hence, only a portion of the fuel is combusted in any given combustion module. Subsequently the thermal energy released at each stage can be captured and removed from the gases prior to subsequent stages, when more fuel is introduced. This allows the SPOC process to operate with minimal FGR, avoiding the associated efficiency losses and additional costs. While the staging controls the heat release profile in SPOC, operating in a pressurized condition yields a more compact system, reducing modular boiler size and delivering enhanced heat transfer. Additionally, operating at elevated pressures ensures that the latent heat of moisture available from moisture in the fuel and generated by the combustion of the hydrogen content in the fuel can be captured as useful thermal energy for steam turbine integration. This is possible due to elevated dew point from the high partial pressure of the moisture generated in this process, which allows substantial feedwater heater bypassing to be achieved. The inclusion of this thermal energy, normally lost to the atmosphere in traditional combustion processes or to cooling systems in atmospheric oxy-combustion, allows the resultant net efficiency of the SPOC system to be up to 6 percentage points greater than first-generation systems. To begin the process of developing this technology for full-scale application, the Electric Power Research Institute, Inc. teamed up with WUSTL, American Air Liquide, Doosan Babcock, and the U.S. Department of Energy to investigate a practical and workable boiler design concept that would minimize process risks where possible. The SPOC system offers unique process flexibility opportunities due to the staged nature of the combustion, making it a prime candidate for future primary energy delivery where the ability to operate at reduced load in an efficient manner and ramp rapidly will be valuable for balancing intermittent renewable electricity generation. The efficiency of traditional coal-fired power plants is lower at reduced loads below the steam temperature control range due to the challenges in balancing the heat pickup between radiative and convective superheater and reheater surface. Introducing additional heating surface for optimal extended controlled low load operation will likely lead to excessive attemperation at high loads, ultimately leading to a poorer overall cycle efficiency. The SPOC process can facilitate the adjustment of fuel firing rates between stages, targeting heat pickup to where it is most needed and potentially can shut down stages for low-load operation, facilitating an increased steam temperature control range on turndown. The boiler design concept assessment is being carried out to identify the maximum permissible compactness of the SPOC boiler heating surfaces. The assessment will determine the minimum overall height that will deliver appropriate tube operating metal temperatures at full load and achieve rated reheat steam temperatures at low operating loads, balanced against the needs of efficient coal combustion, and the potential resultant slagging and ash environments. The design parameters are being validated by combustion testing in the 100-kWth pressurized combustion test rig at WUSTL. Parameters being investigated include flame stability, fuel burnout, ash composition, radiative heat flux, and temperature profiles. These are being carried out for a range of inlet gas conditions and compositions and at multiple load conditions to investigate combustion stability at reduced load. The results of this testing inform the modeling of the large-scale system, that was sized at 550 MWe to allow direct comparison with the National Energy Technology Laboratory baseline cases for atmospheric oxy-combustion, air firing, and air firing with post-combustion capture.

20 FOSSIL-FUELED POWER PLANTS↗