Experimental Characterization of a Grid-Loss Event on a 2.5-MW Dynamometer Using Advanced Operational Modal Analysis: Preprint

This paper experimentally investigates a worst case grid loss event conducted on the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) drivetrain mounted on the 2.5MW NREL dynamic nacelle test-rig. The GRC drivetrain has a directly grid-coupled, fixed speed asynchronous generator. The main goal is the assessment of the dynamic content driving this particular assess the dynamic content of the high-speed stage of the GRC gearbox. In addition to external accelerometers, high frequency sampled measurements of strain gauges were used to assess torque fluctuations and bending moments both at the nacelle main shaft and gearbox high-speed shaft (HSS) through the entire duration of the event. Modal analysis was conducted using a polyreference Least Squares Complex Frequency-domain (pLSCF) modal identification estimator. The event driving the torsional resonance was identified. Moreover, the pLSCF estimator identified main drivetrain resonances based on a combination of acceleration and strain measurements. Without external action during the grid-loss event, a mode shape characterized by counter phase rotation of the rotor and generator rotor determined by the drivetrain flexibility and rotor inertias was the main driver of the event. This behavior resulted in significant torque oscillations with large amplitude negative torque periods. Based on tooth strain measurements of the HSS pinion, this work showed that at each zero-crossing, the teeth lost contact and came into contact with the backside flank. In addition, dynamic nontorque loads between the gearbox and generator at the HSS played an important role, as indicated by strain gauge-measurements.

17 WIND ENERGY↗

Measuring Gearbox Torque Loss

Accuracy increased by measuring small torque differences directly. Input and output torques are balanced by mechanical linkage in transmission-testing apparatus. Force applied to load cell proportional to frictional torque loss in transmission. Apparatus measures portion of input torque lost to friction in automotive transmissions or other gearbox. Apparatus more sensitive than previous measuring systems.

Schmidt, L. F.↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This paper presents the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

grid-following inverter↗

Evaluation of Optimal Net Load Management in Microgrids Using Hardware-in-the-Loop Simulation

This presentation discusses the performance evaluation of a net load management (NLM) engine that balances load and generation in an isolated community to power a critical facility after a grid interruption event (e.g., the loss of a large generation unit). This NLM engine is particularly important for microgrid systems because it provides a high-speed, cost-optimal control solution to coordinate grid-forming inverters and to dispatch grid-following inverters and deferrable loads in microgrid systems to enhance grid resilience and reliability. The NLM algorithm cost-optimally dispatches the grid-following inverters and deferrable loads based on the demanded power and load priorities, and the grid-forming inverters use droop control to form system voltages and share active and reactive power. A controller-hardware-in-the-loop platform is developed to evaluate the control performance of the NLM algorithm with two sequential contingency events of lost generation units. The experimental results indicate that the NLM engine can maintain system stability, achieve the targeted system voltage and frequency, and balance load and generation to serve the critical facility with improved system resilience and reliability.

droop control↗

Distribution-Connected PV's Response to Voltage Sags at Transmission-Scale

The ever increasing amount of residential- and commercial-scale distribution-connected PV generation being installed and operated on the U.S.'s electric power system necessitates the use of increased fidelity representative distribution system models for transmission stability studies in order to ensure the continued safe and reliable operation of the grid. This paper describes a distribution model-based analysis that determines the amount of distribution-connected PV that trips off-line for a given voltage sag seen at the distribution circuit's substation. Such sags are what could potentially be experienced over a wide area of an interconnection during a transmission-level line fault. The results of this analysis show that the voltage diversity of the distribution system does cause different amounts of PV generation to be lost for differing severity of voltage sags. The variation of the response is most directly a function of the loading of the distribution system. At low load levels the inversion of the circuit's voltage profile results in considerable differences in the aggregated response of distribution-connected PV Less variation is seen in the response to specific PV deployment scenarios, unless pushed to extremes, and in the total amount of PV penetration attained. A simplified version of the combined CMPLDW and PVD1 models is compared to the results from the model-based analysis. Furthermore, the parameters of the simplified model are tuned to better match the determined response. The resulting tuning parameters do not match the expected physical model of the distribution system and PV systems and thus may indicate that another modeling approach would be warranted.

14 SOLAR ENERGY↗

Three story residence with solar heat--Manchester, New Hampshire

When heat lost through ducts is counted for accurate performance assessment, solar energy supplied 56 percent of building's space heating load. Average outdoor temperature was 53 degrees F; average indoor temperature was 69 degrees F. System operating modes included heating from solar collectors, storing heat, heating from storage, auxiliary heating with oil fired furnace, summer venting, and hot water preheating.

Source record↗

Collective Analysis of Alpha Particle Losses Due to Self-Absorption by Mass Loading on Radioactive Particulate Glass Fiber Filters

In this study, we derived a relationship between filter mass loading and the percent loss during analysis using the mass loading data collected from six previous studies of self-absorption. Components of mass loading include particulate dust, radioactive particulates, and filter material. In a research report published in 1984, Higby calculated a minimum burial depth for an alpha particle to be lost due to absorption (100% loss) of about 3.7 mg/cm 2 based on calculations for the range of 239-Pu alpha particles in glass fiber filters. From there, Higby concluded that a correction factor of 0.85 assumes approximately 15% losses in the count rate of both alpha and beta particles. In 2000, Luetzelschwab et al. recommended assuming a 40% loss at a loading of 3.3 mg/cm 2 and a 28% loss for a loading of 2.3 mg/cm 2 which included the frontal face mass of the filter. More recently, the 100% losses due to absorption were reported to be in the 10 mg/cm 2 range. Presented here is a trinomial relationship method of relating percent loss due to self-absorption to filter mass loading, based on data reported by Higby, Luetzelschwab et al., Huang et al., Barnett et al., Smith et al., and Hogue et al. Under normal operating conditions at the stacks monitored by Effluent Management, the mass loading of sample filters averages 0.09 ± 0.12 (2s) mg/cm 2 (excluding negative values and outliers) and ranges from 0 mg/cm 2 to 0.24 mg/cm 2 . Based on current mass loading results for Effluent Management stack sample filters, the forced-zero trinomial relationship method estimated self-absorption losses of less than 5%. Because American National Standards Institute/Health Physics Society N13.1-2011 guidelines indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the count rate by more than 5%, it is possible continued application of a correction factor to the Effluent Management stack samples is no longer necessary. Nevertheless, continuing to assign a correction factor at the 5% threshold (i.e., 0.95) would be a conservative approach.

36 MATERIALS SCIENCE↗

Verification of dry storage cask loading using monoenergetic photon sources

Safeguarding the contents of spent nuclear fuel dry storage casks requires the verification of cask contents, especially if continuity of knowledge has been lost. The high attenuation of the cask’s thick shielding and stored fuel assemblies makes verification difficult using conventional photon radiography. Thomson-scattering quasi-monoenergetic photon sources offer narrow angular and energy spread for increased penetration. This paper demonstrates the advantages of such a source by examining effects of source properties on transmission through thick, highly attenuating objects. This information is then applied to calculations and simulations of transmission for a variety of photon sources and cask configurations. Here, the performance of the source is compared to traditional bremsstrahlung sources and other advanced methods, in the context of typical nuclear fuel dry storage casks. It is shown that the use of a Thomson scattering based quasi-monoenergetic photon source enables determination of fuel assembly occupancies faster and more accurately than other methods.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

JT9D performance deterioration results from a simulated aerodynamic load test

The results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance are presented. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance losses. To accomplish these objectives, a JT9D-7AH engine was assembled with average production clearances and new seals as well as extensive instrumentation to monitor engine performance, case temperatures, and blade tip clearance changes. A special loading device was designed and constructed to permit application of known moments and shear forces to the engine by the use of cables placed around the flight inlet. The test was conducted in the Pratt & Whitney Aircraft X-Ray Test Facility to permit the use of X-ray techniques in conjunction with laser blade tip proximity probes to monitor important engine clearance changes. Upon completion of the test program, the test engine was disassembled, and the condition of gas path parts and final clearances were documented. The test results indicate that the engine lost 1.1 percent in thrust specific fuel consumption (TSFC), as measured under sea level static conditions, due to increased operating clearances caused by simulated flight loads. This compares with 0.9 percent predicted by the analytical model and previous study efforts.

Stakolich, E. G.↗

JT9D performance deterioration results from a simulated aerodynamic load test

This paper presents the results of testing to identify the effects of simulated aerodynamic flight loads on JT9D engine performance. The test results were also used to refine previous analytical studies on the impact of aerodynamic flight loads on performance losses. To accomplish these objectives, a JT9D-7AH engine was assembled with average production clearances and new seals as well as extensive instrumentation to monitor engine performance, case temperatures, and blade tip clearance changes. A special loading device was designed and constructed to permit application of known moments and shear forces to the engine by the use of cables placed around the flight inlet. The test was conducted in the Pratt and Whitney Aircraft X-Ray Test Facility to permit the use of X-ray techniques in conjunction with laser blade tip proximity probes to monitor important engine clearance changes. Upon completion of the test program, the test engine was disassembled, and the condition of gas path parts and final clearances were documented. The test results indicate that the engine lost 1.1 percent in thrust specific fuel consumption (TSFC), as measured under sea level static conditions, due to increased operating clearances caused by simulated flight loads. This compares with 0.9 percent predicted by the analytical model and previous study efforts.

Stakolich, E. G.↗

Facile one-pot synthesis and characterization of nickel supported on hierarchically porous carbon

Highlights: • Novel, inexpensive, one-pot, synthesis method for Ni on hierarchically porous carbon. • Disappearance of surfactant mesopores seen with incorporation of nickel. • Distribution of Ni nanoparticles on the hierarchically porous carbon support was studied by SEM. • Nickel nanoparticles were dispersed on macropore walls and not within carbon. - Abstract: Described is a novel, facile route for the synthesis of nickel supported on hierarchically porous carbon (Ni/HPC) using a one-pot co-gelation sol–gel method. Ni/HPC with varying nickel loadings (0.5, 1, 2.5 and 5 wt% Ni) were synthesized and the materials characterized by nitrogen physisorption, X-ray diffraction (XRD), scanning electron microscopy (SEM), and Fourier transform infrared (FTIR) and Raman spectroscopies. The results show a three-dimensional network of disordered carbon with fine nickel nanoparticles of sizes ranging from 8 nm to 13 nm at 0.5 wt% Ni loading which gradually increased with increase in the Ni loading. The carbon structure was retained at the macropore level, but not at the mesoscale where the ordered mesopores were lost on nickel addition. The nickel nanoparticles were observed to grow on the surface of the ligaments. This may make them particularly suitable for low pressure Ni-catalyzed organic transformations e.g., hydrogenations, C–C coupling, C-heteroatom coupling, etc.

36 MATERIALS SCIENCE↗

Electron trapping and acceleration by the plasma wakefield of a self-modulating proton beam

It is shown that co-linear injection of electrons or positrons into the wakefield of the self-modulating particle beam is possible and ensures high energy gain. The witness beam must co-propagate with the tail part of the driver, since the plasma wave phase velocity there can exceed the light velocity, which is necessary for efficient acceleration. If the witness beam is many wakefield periods long, then the trapped charge is limited by beam loading effects. The initial trapping is better for positrons, but at the acceleration stage a considerable fraction of positrons is lost from the wave. For efficient trapping of electrons, the plasma boundary must be sharp, with the density transition region shorter than several centimeters. Positrons are not susceptible to the initial plasma density gradient.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discussion of the reliability of electron densities and energies interpreted from data and limits on the proton energy and density

Analysis of radio observations of Jupiter were changed to take into account the antenna resolution. A dipole magnetic field with a surface equatorial value of 7 gauss is assumed. The electron temperature is found to increase for r 2.5 Jupiter radii with decreasing r as 1/r cubed, reaching a peak of about 100 MeV at r = 2.5 Jupiter radii. For r 2.5 Jupiter radii, the electron temperature goes as r to the 6th power because of energy lost to radiation. The consequences of making an upper estimate on the proton flux by assuming the magnetic field is loaded with all the energetic protons it can hold are described. The upper limits of proton energy, density, flux, and energy flux are calculated for 1, 2, 2.5, 3, and 6 Jupiter radii. The proton energy and velocity estimates are considered to be fairly reliable; the upper limit to the number density is probably much higher than actuality.

Beard, D. B.↗

Aerodynamic heating in large cavities in an array of RSI tiles

A large panel of reusable surface insulation (RSI) tiles including lost tile cavities was aerothermally tested in the Langley 8 foot high temperature structures tunnel to determine both the heat load within the cavities and the structural performance of the RSI surrounding the cavities. Tests were conducted with a turbulent boundary layer at a nominal free stream Mach number of 6.6, a total temperature of 1800 K, a Reynolds number per meter of 5 million, and a dynamic pressure of 62 kPa. The maximum aerodynamic heating to the floor of the cavity was two to three times the normal surface heating. The cavity heating rates agreed with data from other facilities and were successfully correlated with an empirical equation. A zippering failure occurred to a tile downstream of a double tile cavity when the separated flow attached to the floor of the cavity and forced the tile from its position.

Hunt, L. R.↗

Electrodynamic Tethers. 1: Power Generator in LEO. 2: Thrust for Propulsion and Power Storage

An electrodynamic tether consists of a long insulated wire in space whose orbital motion cuts across lines of magnetic flux to produce an induce voltage that in typical low orbits averages about 200 v/km. Such a system should be capable of generating substantial electrical power, at the expense of IXB drag acting on its orbital energy. If a reverse current is driven against the induced voltage, the system should act as a motor producing IXB thrust. A reference system was designed, capable of generating 20 KW of power into an electrical load located anywhere along the wire at the expense of 2.6N (20,000 J/sec) drag on the wire. In an ideal system, the conversion between mechanical and electrical energy would reach 100% efficiency. In the actual system part of the 20 KW is lost to internal resistance of the wire, plasma and ionosphere, while the drag force is increased by residual air drag. The 20 KW PMG system as designed is estimated to provide 18.7 KW net power to the load at total drag loss of 20.4 KJ/sec, or an overall efficiency of 92%. Similar systems using heavier wire appear capable of producing power levels in excess of 1 Megawatt at voltages of 2-4 KV, with conversion efficiency between mechanical and electrical power better than 95%. The hollow cathode based system should be readily reversible from generator to motor operation by driving a reverse current using onboard power.

Mccoy, J. E.↗

Remote Sensing of Ground Deformation for Monitoring Groundwater Management Practices: Application to the Santa Clara Valley During the 2012-2015 California Drought

Groundwater management typically relies on water-level data and spatially limited deformation measurements. While interferometric synthetic aperture radar has been used to study hydrological deformation, its limited temporal sampling can lead to biases in rapidly changing systems. Here we use 2011–2017 COSMO-SkyMed data with revisit intervals as short as 1 day to study the response of the Santa Clara Valley (SCV) aquifer in California to the unprecedented 2012–2015 drought. Cross-correlation and independent component analyses of deformation time series enable tracking water through the aquifer system. The aquifer properties are derived prior to and during the drought to assess the success of water-resource management practices. Subsidence due to groundwater withdrawal dominates during 2011–2017, limited to the confined aquifer and west of the Silver Creek Fault, similar to predrought summer periods. Minimum water levels and elevations were reached in mid-2014, but thanks to intensive groundwater management efforts the basin started to rebound in late 2014, during the deepening drought. By 2017, water levels were back to their predrought levels, while elevations had not yet fully rebounded due to the delayed poroelastic response of aquitards and their large elastic compressibility. As water levels did not reach a new lowstand, the drought led to only elastic and recoverable changes in the SCV. The SCV lost 0.09 km 3 during the drought while seasonal variations amount to 0.02 km 3 . As a result, analysis of surface loads due to water mass changes in the aquifer system suggests that groundwater drawdowns could influence the stress on nearby faults.

54 ENVIRONMENTAL SCIENCES↗

PAAV Concept Document

The Pathfinding for Airspace with Autonomous Vehicles (PAAV) Concept Document, version 1.0, lays out the key challenges and potential solutions for the use of uncrewed aircraft (UA) technology for future regional air cargo operations. The challenges and solutions described in this document were informed by communications with the UA industry community (e.g., RTCA, the Federal Aviation Administration, and regional air cargo business operators), as well as the PAAV team’s research activities during the last two years including four tabletop exercises, a human-in-the-loop simulation study, a numerical simulation study, a functional allocation study, and flight data analysis (Appendix A). This document first describes the expected operational context of PAAV (Section 2), such as the flight mission, baseline UAS components, nominal operations, m:N operations (i.e., "m" remote pilots per "N" aircraft), and off-nominal operations. This context sets the scope for the PAAV concept development work. PAAV concept development assumes that UA operations will be increasingly autonomous. Thus, near- and far-term assumptions are defined (Section 3). PAAV identified seven key challenges for UA operations (Section 4): - Flight route planning - Separation and flow management - Traffic pattern integration - Contingency management - Taxi, takeoff, and landing - m:N operations - Communications operations The following 13 potential solutions to these challenges are then described (Section 5): - Scalable communications architecture - Data link - Designated UAS corridors - Crew planning for m:N operations - Flight route optimization - Traffic load-level control - Trajectory solutions with data link - Automated hazard avoidance for m:N operations - Traffic pattern integration (TPI) tool - Standard lost command and control (C2) link (LC2L) procedures - Automated hazard avoidance under LC2L - Auto-taxi, auto-takeoff, and auto-land - Ground control station (GCS) user interface for m:N operations The document attempts to link each of these solutions to one or more of the challenge areas. Novel solutions involving numerous automation technologies are needed to mitigate traffic and airspace management challenges, especially for realizing m:N operations and ensuring safety under LC2L conditions. The purpose of this document is to help understand alternatives and tradeoffs among potential solutions and provide a foundation for a cohesive PAAV concept that will be described and refined in subsequent concept versions.

Unmanned aircraft, uncrewed aircraft, regional air↗

Incentive-Based Control and Coordination of Distributed Energy Resources. Final Report

The rapid growth of low-inertia renewable energy resources represents an immense opportunity for the U.S. to minimize its carbon footprint, while presenting a challenge for system operators as traditional “spinning” generation resources are displaced. This transformation requires solutions to robustly and cost-effectively manage dynamic changes on the grid while ensuring quality of service. There is growing recognition that distributed energy resources (DERs – loads, distributed generation, storage, electric vehicles, etc.) represent a great potential to perform this function. This report details a scalable hierarchical control strategy for coordinating thousands of heterogeneous DERs in order to provide three ancillary gird services: 1) frequency response, a rapid (within 2 seconds) service used to maintain the grid at 60 Hz; 2) regulation response, a larger response used to balance on-going differences in supply and demand on the grid; and, 3) ramping reserve, used to bring on capacity to replace lost generation. The developed control architecture consists of 1) a Distribution Reliability Coordinator (DRC), 2) aggregator controllers, and finally, 3) DER controllers. The DRC coordinates all the flexible loads and distributed energy resources on the distribution system and bids the aggregate flexibility into the wholesale market. The DRC also performs resource allocation (deciding how the flexible devices on the distribution system will be dispatched) to meet the requirements for each of the three ancillary services. The aggregators control a collection of devices that are geographically co-located and provide a platform to aggregate their flexibility and mitigate uncertainty associated with a single flexible load by managing a large aggregation of similar loads (so that any stochastic effects average out). Finally, DER controllers (for example, thermostats for air conditioners, chargers for electric vehicles) adjust the power consumption of individual devices to ensure accurate and reliable delivery of the requested grid services. Evaluation and validation of this approach was conducted with a mixture of simulation and hardware testing for a range of DERs in residential (air conditioners and water heaters), commercial HVAC (ventilation fans and central chiller plants), and micro-grids (battery energy storage, solar PV etc.). This culminated in DER hardware and simulation models operating in conjunction with grid simulations as part of a large scale federated test-bed demonstration. Simulations of over 10,000 controllable residential devices (a combination of air conditioners, water heaters, batteries, and electric vehicles) demonstrated that this advanced control approach could simultaneously meet all three grid services. Furthermore, hardware-in-the-loop testing was performed with operational micro-grid and commercial building HVAC equipment. The micro-grid equipment (representing PV, battery storage, and back-up generators) demonstrated the ability to meet all frequency response requirements (except ramping time). The commercial building HVAC ventilation equipment successfully provided the regulating response service. An Industry Advisory Board (IAB) was formed and engaged throughout the project to get feed-back on project risks and potential commercialization barriers. Their input was invaluable in identify key risks stemming from regulatory and market access challenges, financial risks from under-performance, and competitive threats from utility-scale solutions such as integrated storage. A phased commercialization plan was developed that addresses continued risk reduction (value proposition refinement and performance uncertainty assessments), piloting through field demonstrations with key stakeholders, and finally, deployment as an emerging standard for DER control.