Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “long pulse operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

The effects of pretreatment conditions on a Pt/SnO2 catalyst for the oxidation of CO in CO2 lasers

CO oxidation catalysts with high activity at 25 to 100 C are important for long life, closed cycle operation of pulsed CO2 lasers. A reductive pretreatment with either CO or H2 was shown to significantly enhance the activity of a commercially available platinum on tin (IV) oxide (Pt/SnO2) catalyst relative to an oxidative or inert pretreatment of no pretreatment. Pretreatment at temperatures of 175 C and above causes an initial dip in the observed CO2 yield before the steady state yield is attained. This dip was found to be caused by dehydration of the catalyst during pretreatment and is readily eliminated by humidifying the catalyst or the reaction gas mixture. It is hypothesized that the effect of humidification is to increase the concentration of OH groups on the catalyst surface which play a role in the reaction mechanism.

Schryer, David R.↗

Thermal effects on cavity stability of chromium- and neodymium-doped gadolinium scandium gallium garnet laser under solar-simulator pumping

Results are presented on testing a Cr- and Nd-codoped Gd-Sc-Ga-garnet (Cr:Nd:GSGG) crystal and a Nd:YAG crystal (both of 3.2 mm diam and 76-mm long) for pulsed and CW laser operations using a flashlamp and solar simulator as pumping sources. Results from experiments with the flashlamp show that, at pulse lengths of 0.11, 0.28, and 0.90 ms, the slope efficiency of the Cd:Nd:GSGG crystal was higher than that of the Nd:YAG crystal and increased with pulse width. With the solar simulator, however, the CW laser operation of the Cr:Nd:GSGG crystal was limited to intensities not greater than 1500 solar constants, while the Nd:YAG laser successfully performed for all pump beam intensities available. It was found that the exposure for several minutes of the Cr:Nd:GSGG crystal to pump beam intensity of 3000 solar constants led to its damage by thermal cracking, indicating that a better solar-pumped CW laser performance may be difficult to realize with rod geometry.

Kim, Kyong H.↗

Characterization of beam ion loss in high poloidal beta regime on EAST

A critical issue for achieving the integrated operation of steady-state long-pulse high-confinement (H-mode) plasmas on experimental advanced superconducting tokamak (EAST) is to improve beam ion population confinement during neutral beam injection (NBI). To study the characterization of beam ion loss and improve beam ion confinement, the steady-state long pulse scenario discharges were conducted on EAST (β p $\geqslant$ 2.0, β N $\geqslant$ 1.7, q 95 $\geqslant$ 6.7 and H 98y2 $\geqslant$ 1.1) with NBI heating. Based on neutron yield, the beam voltage and line-averaged electron density were adjusted from 50 kV to 60 kV and 4.4 × 10 19 m –3 to 5.0 × 10 19 m –3 , respectively. The results show that the dominant mechanisms of beam ion loss are shine-through loss, prompt loss, and stochastic ripple loss. The shine-through loss fraction is determined by initial velocity, flight time and entire beam path. The change in prompt loss fraction is caused by the change in the deposition of beam ions. The change in stochastic ripple loss fraction is caused by the change in the initial fraction of trapped-confined ions. Detailed physics shows that the prompt loss fraction during counter-Ip injections (~45%) is far larger than during co-Ip injections (~5%) due to the finite orbit width. The lost ions are mainly deposited on the lower divertor or below the midplane since the direction of magnetic drift is vertical down. The orbit types of prompt loss during counter-Ip injections are mainly trapped-lost and ctr-passing lost. To minimize the prompt loss fraction during counter-Ip injections, a reversed Ip configuration (rev-Ip) discharge #94758 was conducted. The result suggests that the beam ion wall load fraction during counter-Ip tangential injection (~3%) is far lower than that in normal Ip configuration (nor-Ip) discharge #94820. It is also found that the confinement of beam ion population in the counter-Ip injection #94758 was greatly improved when compared to #94820. Finally, this study can provide unique support for the improvement of beam ion population confinement and for the performance evaluation of the NBI system on EAST and future tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Catalysts for long-life closed-cycle CO2 lasers

Long-life, closed-cycle operation of pulsed CO2 lasers requires catalytic CO-O2 recombination both to remove O2, which is formed by discharge-induced CO2 decomposition, and to regenerate CO2. Platinum metal on a tin (IV) oxide substrate (Pt/SnO2) has been found to be an effective catalyst for such recombination in the desired temperature range of 25 to 100 C. This paper presents a description of ongoing research at NASA-LaRC on Pt/SnO2 catalyzed CO-O2 recombination. Included are studies with rare-isotope gases since rare-isotope CO2 is desirable as a laser gas for enhanced atmospheric transmission. Results presented include: (1) achievement of 98% to 100% conversion of a stoichiometric mixture of CO and O2 to CO2 for 318 hours (greater than 1 x 10 to the 6th power seconds), continuous, at a catalyst temperature of 60 C, and (2) development of a technique verified in a 30-hour test, to prevent isotopic scrambling when CO-18 and O-18(2) are reacted in the presence of a common-isotope Pt/Sn O-16(2) catalyst.

Schryer, David R.↗

Research on catalysts for long-life closed-cycle CO2 laser oaperation

Long-life, closed-cycle operation of pulsed CO2 lasers requires catalytic CO-O2 recombination both to remove O2, which is formed by discharge-induced CO2 decomposition, and to regenerate CO2. Platinum metal on a tin-oxide substrate (Pt/SnO2) has been found to be an effective catalyst for such recombination in the desired temperature range of 25 to 100 C. This paper presents a description of ongoing research at NASA-Langley on Pt/SnO2 catalyzed CO-O2 recombination. Included are studies with rare-isotope gases since rare-isotope CO2 is desirable as a laser gas for enhanced atmospheric transmission. Results presented include: (1) the effects of various catalyst pretreatment techniques on catalyst efficiency; (2) development of a technique, verified in a 30-hour test, to prevent isotopic scrambling when C(O-18) and (O-18)2 are reacted in the presence of a common-isotope Pt/Sn(O-16)2 catalyst; and (3) development of a mathematical model of a laser discharge prior to catalyst introduction.

Sidney, Barry D.↗

Pretreatment of CO oxidation catalysts

CO oxidation catalysts with high activity in the range of 25 C to 100 C are important for long-life, closed-cycle operation of pulsed carbon dioxide 2 lasers. A reductive pretreatment with either CO or H sub 2 was shown to significantly enhance the activity of a commerically-available platinum on tin (IV) oxide (Pt/SnO2) catalyst relative to an oxidative or inert pretreatment or no pretreatment. Pretreatment at temperatures of 175 C and above caused an initial dip in observed CO or O sub 2 loss or CO sub 2 formation in a test gas mixture of 1 percent CO and 0.5 percent O sub 2 in a He gas matrix before a steady-state yield was obtained. This dip was found to be caused by dehydration of the surface of the catalyst and was readily eliminated by humidifying the catalyst or the test gas mixture. It was also found that too much moisture resulted in a lower overall yield of CO sub 2. Under similar conditions, it is hypothesized that the effect of the humidification is to increase the concentration of OH groups on the surface of the catalyst. The effect of having high concentration of CO sub 2 in the test gas mixture upon the loss of CO and O sub 2 as well as the effect of periods of relaxation of the catalyst under non-test gas conditions was studied. The purpose of these studies was to gain an insight into the mechanism of CO oxidation on this type of catalyst.

Vannorman, John D.↗

The effect of H2O and pretreatment on the activity of a Pt/SnO2 catalyst

CO oxidation catalysts with high activity at 25 C to 100 C are important for long-life, closed-cycle operation of pulsed CO2 lasers. A reductive pretreatment with either CO or H2 has been shown to significantly enhance the activity of a commercially available platinum on tin (IV) oxide (Pt/SnO2) catalyst relative to an oxidative or inert pretreatment or no pretreatment. Pretreatment at temperatures of 175 C and above causes an initial dip in the observed CO2 yield before the steady-state yield is attained. This dip has been found to be caused by dehydration of the catalyst during pretreatment and is readily eliminated by humidifying the catalyst or the reaction gas mixture. It is hypothesized that the effect of humidification is to increase the concentration of OH groups on the catalyst surface which play a role in the reaction mechanism.

Vannorman, John D.↗

The Seismic Signature of a High-Energy Density Physics Laboratory and Its Potential for Measuring Time-Dependent Velocity Structure

The Z Machine at Sandia National Laboratories is a pulsed power facility for high-energy density physics experiments that can shock materials to extreme temperatures and pressures through a focused energy release of up to ~ 25 MJ in < 100 nanoseconds. It has been in operation for more than two decades and conducts up to ~ 100 experiments, or “shots,” per year. Based on a set of 74 known shot times from 2018, we determined that Z Machine shots produce detectable ~ 3–17 Hz ground motion 12 km away at the Albuquerque Seismological Laboratory, New Mexico (ANMO), borehole seismograph, with peak signal at ~ 7 Hz. The known shot waveforms were used to create a three-component template, leading to the detection of 2339 Z Machine shots since 1998 through single-station cross-correlation. Local seismic magnitude estimates range from local magnitude (M L ) —2 to —1.3 and indicate that only a small fraction of the shot energy is transmitted by seismic phases observable at 12 km distance. The most recent major facility renovation, which was intended to decrease mechanical dissipation, is associated with an abrupt decrease in observed seismic amplitudes at ANMO despite stable maximum shot energy. The highly repetitive impulsive sources are well suited to coda-wave interferometry to investigate time-dependent velocity structures. Relative velocity variations (dv/v) show an annual cycle with amplitude of ~ 0.2%. Local minima are observed in the late spring, and dv/v increases through the summer monsoon rainfall, possibly reflecting patchy saturation as rainfall infiltrates near the eastern edge of the Albuquerque basin. Importantly, the cumulative results demonstrate that forensic seismology can provide insight into long-term operation of facilities such as pulsed-power laboratories, and that their recurring signals may be valuable for studies of time-dependent structure

54 ENVIRONMENTAL SCIENCES↗

Mind the gap – Part 1: Accurately locating warm marine boundary layer clouds and precipitation using spaceborne radars

Abstract. Ground-based radar observations show that, over the eastern North Atlantic, 50 % of warm marine boundary layer (WMBL) hydrometeors occur below 1.2 km and have reflectivities of <-17 dBZ, thus making their detection from space susceptible to the extent of surface clutter and radar sensitivity. Surface clutter limits the ability of the CloudSat cloud profiling radar (CPR) to observe the true cloud base in ~52 % of the cloudy columns it detects and true virga base in ~80 %, meaning the CloudSat CPR often provides an incomplete view of even the clouds it does detect. Using forward simulations, we determine that a 250 m resolution radar would most accurately capture the boundaries of WMBL clouds and precipitation; that being said, because of sensitivity limitations, such a radar would suffer from cloud cover biases similar to those of the CloudSat CPR. Observations and forward simulations indicate that the CloudSat CPR fails to detect 29 %–43 % of the cloudy columns detected by ground-based sensors. Out of all configurations tested, the 7 dB more sensitive EarthCARE CPR performs best (only missing 9.0 % of cloudy columns) indicating that improving radar sensitivity is more important than decreasing the vertical extent of surface clutter for measuring cloud cover. However, because 50 % of WMBL systems are thinner than 400 m, they tend to be artificially stretched by long sensitive radar pulses, hence the EarthCARE CPR overestimation of cloud top height and hydrometeor fraction. Thus, it is recommended that the next generation of space-borne radars targeting WMBL science should operate interlaced pulse modes including both a highly sensitive long-pulse mode and a less sensitive but clutter-limiting short-pulse mode.

54 ENVIRONMENTAL SCIENCES↗

Inherent stability of central element coaxial liquid-liquid injectors

Most TRW liquid bi-propellant rocket engines built over the past thirty-plus years have employed a central element coaxial pintle injector and have operated with liquid/liquid propellant injection. This injector is a patented design exclusive to TRW and has unique features that make the rocket engine combustion characteristics different from those of other types of injector engine designs. Its many benefits include excellent combustion performance, efficient deep throttling, adaptability to low cost manufacturing, and high reliability. Approximately 200 pintle injector engines of various sizes and operating on a variety of propellants have been flown without a single inflight failure. An especially important feature of the pintle injector engine is its apparent inherent combustion stability. In over thirty years of development, testing, and production, TRW has never experienced combustion instability in any of its pintle injector engine designs. This has been true of engines operating over a range of thrust from 5 to 250,000 lbs. on earth-storable hypergolic propellants and a large number of smaller engines operating on a variety of propellants (21 combinations) in long duration-firing, pulsing (down to 2 msec), and deep throttling (as much as 19:1) modes. Operating chamber pressures have ranged from 10 to 3,500 psia. This record is particularly impressive given that typical TRW design practice does not consider combustion instability as an issue and no pintle engine has ever employed stability-enhancing features, such as baffles or acoustically resonant chambers. In spite of this, TRW engines have operated stably in regimes not possible with other types of injectors. Various physical explanations and combustion process models for this favorable stability characteristic have been postulated. However, a definitive study that unequivocally establishes the important stabilizing mechanisms still remains to be conducted.

Stoddard, Frank J.↗

Spectral broadening and compression of picosecond pulses in air using a multi-pass cell

We report the spectral broadening and post-compression of picosecond pulses using a multi-pass cell (MPC) operating in air. A 2 m-long bi-concave cavity with 41 reflections and 96.4% transmission was designed and implemented, optimized for the compression of 5.5 ps, 4.5 mJ pulses from a Yb:YAG laser operating at 1030 nm. A 19.3-fold spectral broadening was obtained, increasing the bandwidth from 0.3 nm to 5.8 nm, which enabled pulse compression down to 547 fs with a symmetric temporal profile close to the transform limit. These results demonstrate the feasibility of using open-air MPCs for high-energy picosecond pulse post-compression, without the need for sealed chambers, while preserving high mode quality and transmission. Scaling to pulse higher energy is discussed.

Zaldivar Escola, F. [Univ. of Buenos Aires (Argent↗

Optical multiple access techniques for on-board routing

The purpose of this research contract was to design and analyze an optical multiple access system, based on Code Division Multiple Access (CDMA) techniques, for on board routing applications on a future communication satellite. The optical multiple access system was to effect the functions of a circuit switch under the control of an autonomous network controller and to serve eight (8) concurrent users at a point to point (port to port) data rate of 180 Mb/s. (At the start of this program, the bit error rate requirement (BER) was undefined, so it was treated as a design variable during the contract effort.) CDMA was selected over other multiple access techniques because it lends itself to bursty, asynchronous, concurrent communication and potentially can be implemented with off the shelf, reliable optical transceivers compatible with long term unattended operations. Temporal, temporal/spatial hybrids and single pulse per row (SPR, sometimes termed 'sonar matrices') matrix types of CDMA designs were considered. The design, analysis, and trade offs required by the statement of work selected a temporal/spatial CDMA scheme which has SPR properties as the preferred solution. This selected design can be implemented for feasibility demonstration with off the shelf components (which are identified in the bill of materials of the contract Final Report). The photonic network architecture of the selected design is based on M(8,4,4) matrix codes. The network requires eight multimode laser transmitters with laser pulses of 0.93 ns operating at 180 Mb/s and 9-13 dBm peak power, and 8 PIN diode receivers with sensitivity of -27 dBm for the 0.93 ns pulses. The wavelength is not critical, but 830 nm technology readily meets the requirements. The passive optical components of the photonic network are all multimode and off the shelf. Bit error rate (BER) computations, based on both electronic noise and intercode crosstalk, predict a raw BER of (10 exp -3) when all eight users are communicating concurrently. If better BER performance is required, then error correction codes (ECC) using near term electronic technology can be used. For example, the M(8,4,4) optical code together with Reed-Solomon (54,38,8) encoding provides a BER of better than (10 exp -11). The optical transceiver must then operate at 256 Mb/s with pulses of 0.65 ns because the 'bits' are now channel symbols.

Mendez, Antonio J.↗

Free-Space Quantum Key Distribution with a High Generation Rate Potassium Titanyl Phosphate Waveguide Photon-Pair Source

A high generation rate photon-pair source using a dual element periodically-poled potassium titanyl phosphate (PP KTP) waveguide is described. The fully integrated photon-pair source consists of a 1064-nanometer pump diode laser, fiber-coupled to a dual element waveguide within which a pair of 1064-nanometer photons are up-converted to a single 532-nanometer photon in the first stage. In the second stage, the 532-nanometer photon is down-converted to an entangled photon-pair at 800 nanometer and 1600 nanometer which are fiber-coupled at the waveguide output. The photon-pair source features a high pair generation rate, a compact power-efficient package, and continuous wave (CW) or pulsed operation. This is a significant step towards the long term goal of developing sources for high-rate Quantum Key Distribution (QKD) to enable Earth-space secure communications. Characterization and test results are presented. Details and preliminary results of a laboratory free-space QKD experiment with the B92 protocol are also presented.

photons↗

Comparison of thermionic filament and carbon nanotube field emitter-based electron ionization sources in cycloidal coded aperture mass analyzers

This report compares the coded aperture imaging performance of thermionic filament and carbon nanotube (CNT) field emitter-based electron sources in cycloidal-coded aperture mass spectrometers. The use of spatially coded apertures in mass spectrometry enables miniaturization by improving throughput without sacrificing resolution. CNT-based electron ionization sources for mass spectrometers provide several potential benefits over conventional thermionic emitters, including low voltage and low power consumption, room temperature operation, long lifetime, and ability to emit electrons in a pulsed mode. However, spatiotemporal variation in electron emission from CNTs is a major disadvantage. In this study, electron emission stability and spatiotemporal stability of the coded aperture image were compared for coded aperture cycloidal mass analyzers with either a CNT-based ion source or a thermionic filament-based ion source. We found that the thermionic filament-based ion source produced a significantly more stable coded aperture image than the CNT based ion source. The aperture image fluctuations in the CNT-based source are likely a result of adsorption and desorption of molecules on the CNT surface that cause local work function changes and induce spatiotemporal variation in electron emission and subsequent ion generation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Closed-Cycle, Frequency-Stable CO2 Laser Technology

These proceedings contain a collection of papers and comments presented at a workshop on technology associated with long-duration closed-cycle operation of frequency-stable, pulsed carbon dioxide lasers. This workshop was held at the NASA Langley Research Center June 10 to 12, 1986. The workshop, jointly sponsored by the National Aeronautics and Space Administration (NASA) and the Royal Signals and Radar Establishment (RSRE), was attended by 63 engineers and scientists from the United States and the United Kingdom. During the 2 1/2 days of the workshop, a number of issues relating to obtaining frequency-stable operation and to the catalytic control of laser gas chemistry were discussed, and specific recommendations concerning future activities were drafted.

Batten, Carmen E.↗

Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

The design and test results for two types of pulsed gas valves are presented. The valves, a piezo valve and a solenoid actuated valve, must have exceedingly long lifetime to support gas-fed pulsed electric thruster operation for missions of interest. The performance of both valves was tested, with both demonstrating the capability to throttle the gas flow rate while maintaining low leakage levels below 10(exp -3) sccs of He at the beginning of valve lifetime. The piezo valve varies the flow rate by changing the amount that the valve is open, which is a function of applied voltage. This valve demonstrated continuous throttlability from 0-10 mL/s, with opening and closing times of 100 microsecond or less. The solenoid actuated valve flow rate changes as a function of the inlet gas pressure, with demonstrated flow rates in these tests from 2.7-11 mL per second. The valve response time is slower than the piezo valve, opening in 1-2 ms and closing in several ms. The solenoid actuated valve was tested to one million cycles, with the valve performance remaining relatively unchanged throughout the test. Galling of the sliding plunger caused the valve to bind and fail just after one million cycles, but at this point in the test the valve sealing surface leak rate still appeared to be well below the maximum target leak rake of 1×10(exp -3) sccs of He.

Burkhardt, Wendel M.↗

Improving Reliability of High Power Quasi-CW Laser Diode Arrays for Pumping Solid State Lasers

Most Lidar applications rely on moderate to high power solid state lasers to generate the required transmitted pulses. However, the reliability of solid state lasers, which can operate autonomously over long periods, is constrained by their laser diode pump arrays. Thermal cycling of the active regions is considered the primary reason for rapid degradation of the quasi-CW high power laser diode arrays, and the excessive temperature rise is the leading suspect in premature failure. The thermal issues of laser diode arrays are even more drastic for 2-micron solid state lasers which require considerably longer pump pulses compared to the more commonly used pump arrays for 1-micron lasers. This paper describes several advanced packaging techniques being employed for more efficient heat removal from the active regions of the laser diode bars. Experimental results for several high power laser diode array devices will be reported and their performance when operated at long pulsewidths of about 1msec will be described.

Amzajerdian, Farzin↗

Ultranarrow linewidth, magnetically switched, long pulse, xenon chloride laser

A spectral linewidth of less than 70 fm and diffraction-limited beam divergence have been obtained from a long-pulse, electric-discharge xenon chloride laser with intracavity Fabry-Perot etalons. A gain duration of 100 ns provided for multipass operation of the etalons, significantly improving both contrast and finesse. The electrical-discharge circuit required to produce this long gain duration was comprised of a pulse-forming network, a saturable-inductor magnetic switch, and a tapered constant-impedance interface transmission line.

Pacala, T. J.↗