Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Metrics and Analytical Frameworks for Valuing Energy Efficiency and Distributed Energy Resources in the Built Environment: Preprint

This paper summarizes efforts to develop new—and enhance existing—analytical frameworks and metrics to quantify the value that grid-interactive efficient homes with solar (GEB-solar homes) can provide. Industry is working to characterize and understand these capabilities and benefits, but existing analytical frameworks for evaluating energy efficiency (EE) are often siloed from those that evaluate distributed energy resources (DERs). Five metrics were adapted from an extensive literature review and applied to case studies of a modeled home in Riverside, California: ramp up/down, cover factor demand/supply, and curtailable load. Eight different technology scenarios were analyzed using a more tightly connected suite of building-to-grid models (BEopt, REopt, ReEDS, and PLEXOS). Additionally, an initial version of the Cambium tool was developed, characterizing the marginal prices and emissions from NREL’s 2018 Standard Scenarios. These grid costs were extended to a time-varying proxy retail rate and applied as part of a new grid alignment metric. In the results, a more integrated combination of GEB-solar technologies led to a higher cover factor demand—the percentage of gross home load covered by on-site solar—however, a benchmark was required to determine what range of cover factor was “best” for given grid conditions. To that end, a grid alignment cost metric was applied to the case study scenarios. The average cost to serve the net load of the home decreased from a median of ~$0.24/kWh to ~$0.10/kWh when the most integrated technology scenario was optimized towards the grid pricing proxy versus the time-of-use (TOU) rate.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Customer enrollment and participation in building demand management programs: A review of key factors

Increasing the efficiency and flexibility of electricity demand is necessary for ensuring a cost-effective and reliable transition to zero-carbon electricity systems. Such demand-side management (DSM) resources have been procured by utilities for decades via energy efficiency and demand response programs; however, the key drivers of program enrollment and customer participation levels remain poorly understood — even as governments and grid planners seek to scale up the deployment of DSM assets to meet climate targets. Here we systematically review the evidence on multiple factors that may influence customer enrollment and participation in building DSM programs, focusing primarily on residential and commercial buildings. We examine the contexts in which relationships between DSM factors and outcomes are most often explored and with which methods; we also score the strength, direction, and internal consistency of each factor's reported impact on the enrollment and participation outcomes. We find that studies most commonly assess the effects of economic incentives for load flexibility on program participation levels, often using simulation-based methods in lieu of measured data. Few studies focus on program enrollment outcomes or regulatory drivers of either enrollment or participation, and gaps are also evident in the coverage of emerging DSM opportunities like load electrification. Removal of structural barriers (e.g., the lack of controls infrastructure) and the use of third party services (e.g., load aggregators) are the factors with the largest positive impacts on DSM outcomes, but no single factor emerges as clearly most impactful. For a given factor, the range of reported impacts typically varies widely across the relevant studies reviewed. Our findings provide a snapshot of the state of knowledge about building DSM and customer decision-making, and they expose key gaps in understanding that must be filled if building DSM is to expand as a critical resource for operating clean power grids.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Simons Observatory Microwave SQUID Multiplexing Detector Module Design

Advances in cosmic microwave background (CMB) science depend on increasing the number of sensitive detectors observing the sky. New instruments deploy large arrays of superconducting transition-edge sensor (TES) bolometers tiled densely into ever larger focal planes. High multiplexing factors reduce the thermal loading on the cryogenic receivers and simplify their design. We present the design of focal-plane modules with an order of magnitude higher multiplexing factor than has previously been achieved with TES bolometers. We focus on the novel cold readout component, which employs microwave SQUID multiplexing (μmux). Simons Observatory will use 49 modules containing 70,000 bolometers to make exquisitely sensitive measurements of the CMB. We validate the focal-plane module design, presenting measurements of the readout component with and without a prototype detector array of 1728 polarization-sensitive bolometers coupled to feedhorns. The readout component achieves a 95% yield and a 910 multiplexing factor. The median white noise of each readout channel is 65 . This impacts the projected SO mapping speed by <8%, which is less than is assumed in the sensitivity projections. The results validate the full functionality of the module. We discuss the measured performance in the context of SO science requirements, which are exceeded.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maximum Cs-137 Curie Loading onto Crystalline Silicotitanate for the Documented Safety Analysis of the Tank Side Cesium Removal Platform

The Tank Side Cesium Removal (TSCR) system is currently being constructed to process Hanford tank waste supernates for vitrification. TSCR incorporates a filtration system and cesium (Cs) removal system using columns filled with crystalline silicotitanate (CST) ion exchanger, produced by Honeywell UOP, LLC. The documented safety analysis (DSA) developed for TSCR limits a single column curie loading to 141,600 Ci; given a 137 Cs isotopic mass fraction of 20% and the planned CST bed size of a TSCR column, this equates to 0.10 mmole Cs per g CST. Factors that influence 137Cs loading onto the CST include, but are not limited to, CST production lot (different production lots behave differently), contact temperature, contact duration, 137Cs mass fraction, and competitors in the tank waste feed. Seventeen tank waste feeds (compositions) were identified by Washington River Protection Solutions to be processed through TSCR. These feed compositions were used to develop a simulant (referred to herein as Stage 1) that would provide an upper bound to the Cs loading onto CST based on maximizing the Cs/Na activity coefficient ratios in solution while maintaining Na at no less than 5.0 M. Building upon this Stage 1 simulant, a series of four additional simulants were developed based on the cationic/anionic species that impact Cs exchange, with each successive formulation relaxing one or more matrix component concentration constraints as show in Table S.1

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Considerations for Medium-Term Load Forecasting in Morocco

There are many factors that determine how demand for electricity may change over time. Medium-term load forecasting is a subset of load forecasting that focuses on the next year. This presentation summarizes analysis performed by NREL on medium-term load forecasting performed for the Moroccan energy system. This analysis includes hourly regressions and load clustering. This work also describes potential next steps that can be implemented by ONEE to improve this medium-term load forecasting.

54 ENVIRONMENTAL SCIENCES↗

Towards Development of a Conceptual Model for Mercury in Bear Creek, Oak Ridge, Tennessee (FY23 Update)

Mercury concentrations in fish in Bear Creek are elevated and comparable to concentrations seen in fish in East Fork Poplar Creek (EFPC) on the Oak Ridge Reservation, even though aqueous inorganic mercury concentrations are orders of magnitude lower in Bear Creek than in EFPC. Acknowledging that the relationship between aqueous and fish tissue mercury concentrations is not linear, and that methylmercury (MeHg) concentrations are likely more related to fish tissue concentrations than aqueous total mercury (Hg T ) concentrations, MeHg production is not easily predicted or controlled. In Bear Creek, where aqueous Hg T concentrations are low, factors other than mercury loading drive the transformation of mercury to MeHg and subsequent trophic transfer to fish. Initial development of a waste disposal facility (Environmental Management Disposal Facility; EMDF) in Bear Creek Valley has begun, and operation of the EMDF has the potential to increase mercury inputs to Bear Creek. Consequently, understanding the factors contributing to elevated MeHg concentrations in water and fish in Bear Creek has increased relevance and importance. This report summarizes data from recent and historical compliance and investigatory studies with an eye toward building a conceptual model to understand the processes affecting mercury transport and transformation in the Bear Creek watershed, as well as to highlight key knowledge gaps in our understanding of these processes that warrant further investigation. The conceptual model will provide a strong technical basis for prioritizing and optimizing potential mitigation actions or best management practices to minimize potential negative effects of the EMDF related to mercury in Bear Creek.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

An Improved Transmission Switching Algorithm for Managing Post-(N-1) Contingencies in Electricity Networks

In this presentation, we detail the shortcomings of existing transmission switching (TS) methodologies for preventing post-contingency loss of load in wide area electric power networks. Following that, we present a bi-level algorithm as an improvement to the state of the art. We show proof-of-concept level results that indicate computational viability, fast solutions, and the ability to pick the same best candidate as non computationally viable methods. Further, our method also minimizes load shedding after the contingency, thus enhancing the reliability and security of electricity supply. We also include a futuristic scenario of increased renewables and decreased natural gas sourced generators to show promising results. We grant permission for our presentation to be recorded and uploaded by the conference organizers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Multi-atom Pt and PtRu catalysts for high performance AEMFCs with ultra-low PGM content

To reduce the platinum group metal (PGM) loading in anion exchange membrane fuel cells (AEMFCs), it is important to transition to catalysts with very low PGM content, and eventually to catalysts that are completely PGM-free. Here, in this work, four supported low-PGM Pt and PtRu catalysts were prepared using a new, simple, scalable technique: Controlled Surface Tension (CST) method. CST allows for a high density of very small multi-atom clusters. Catalysts were physically characterized using a wide array of techniques and tested for their ORR and HOR activity both ex-situ and integrated into operating AEMFCs. The PGM loading was reduced by a factor of 14 while achieving comparable performance to commercial catalysts. AEMFCs were also assembled with ultralow PGM loading (0.05 mgPGM cm -2 ), where PtRu anodes were paired with Fe–N–C cathodes to achieve a specific power of 25 W/mg PGM (40 W/mg Pt ).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air Source Heat Pumps in Very Cold Climates

Air source heat pumps (ASHPs) in heating mode use a refrigeration cycle to remove heat from the outside air and transfer it into a building. Therefore, ASHPs have the potential to save energy compared to conventional heat sources that create the heat as opposed to transferring it from outside. Many cold climate ASHPs available on the market today can operate at outside temperatures of -25 degrees C (-13 degrees F) or even lower. As a result of technological advances and other factors, there is growing interest in ASHPs in cold climates, including very cold regions such as Alaska. However, guidance on the selection, installation, and operation of ASHPs in these very cold climates is limited, as significant data gaps exist regarding the performance of ASHPs in very cold environments. To address these data gaps and guide future innovations, our research team has studied the field performance of several ASHP installations in Alaska and done lab evaluations of several ASHP models using a cold chamber. While a cold chamber cannot fully reflect field conditions, it allowed for changing one variable at a time and gaining additional understanding of the behavior of ASHPs that would be difficult to gain from field studies only. This study focused on two main variables: the temperature in the chamber (representing the outdoor temperature) and the level of thermal loading of the ASHP. The results from the field as well as the lab show that ASHPs can operate with relatively high efficiency even in very cold climates if used in appropriate situations and in an appropriate way. It was found that not only the outside temperature, but also the level of thermal loading is a significant factor affecting the ASHP efficiency and needs to be carefully considered when sizing and operating ASHPs in very cold climates.

air source heat pump↗

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY↗

Validation of high-fidelity ion cyclotron range of frequencies antenna coupling simulations in full 3D geometry against experiments in the ASDEX Upgrade tokamak

We address the validation of finite elements ion cyclotron range of frequencies (ICRF) antenna coupling simulation against experiments performed in the ASDEX Upgrade tokamak. Measurements of the loading resistance in ICRF-heated, magnetically-perturbed 3D plasma discharges are compared against numerical predictions of the RAPLICASOL code. To this end, the 3D induction field and the 3D density profile are modeled by concatenating the PARVMEC, BMW and EMC3-EIRENE codes. The 3D density is input to RAPLICASOL, where full-wave simulations are performed on a finite element mesh retaining full 3D geometry in the ICRF antenna model and the plasma description. The results are further compared with RAPLICASOL simulations using a 1D density profile as measured at the outboard midplane in the same experiments. We find that simulations using a 1D density profile overestimate the change in loading resistance by a factor of ~197 -248%, while simulations using the full 3D density profile are in agreement with experiments within a factor ~16%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Overview of the results from divertor experiments with attached and detached plasmas at Wendelstein 7-X and their implications for steady-state operation

Abstract Wendelstein 7-X (W7-X), the largest advanced stellarator, is built to demonstrate high power, high performance quasi-continuous operation. Therefore, in the recent campaign, experiments were performed to prepare for long pulse operation, addressing three critical issues: the development of stable detachment, control of the heat and particle exhaust, and the impact of leading edges on plasma performance. The heat and particle exhaust in W7-X is realized with the help of an island divertor, which utilizes large magnetic islands at the plasma boundary. This concept shows very efficient heat flux spreading and favourable scaling with input power. Experiments performed to overload leading edges showed that the island divertor yields good impurity screening. A highlight of the recent campaign was a robust detachment scenario, which allowed reducing power loads even by a factor of ten. At the same time, neutral pressures at the pumping gap entrance yielded the particle removal rate close to the values required for stable density control in steady-state operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The three-way junction structure of the HIV-1 PBS-segment binds host enzyme important for viral infectivity

HIV-1 reverse transcription initiates at the primer binding site (PBS) in the viral genomic RNA (gRNA). Although the structure of the PBS-segment undergoes substantial rearrangement upon tRNALys3 annealing, the proper folding of the PBS-segment during gRNA packaging is important as it ensures loading of beneficial host factors. DHX9/RNA helicase A (RHA) is recruited to gRNA to enhance the processivity of reverse transcriptase. Because the molecular details of the interactions have yet to be defined, we solved the solution structure of the PBS-segment preferentially bound by RHA. Evidence is provided that PBS-segment adopts a previously undefined adenosine-rich three-way junction structure encompassing the primer activation stem (PAS), tRNA-like element (TLE) and tRNA annealing arm. Disruption of the PBS-segment three-way junction structure diminished reverse transcription products and led to reduced viral infectivity. Because of the existence of the tRNA annealing arm, the TLE and PAS form a bent helical structure that undergoes shape-dependent recognition by RHA double-stranded RNA binding domain 1 (dsRBD1). Mutagenesis and phylogenetic analyses provide evidence for conservation of the PBS-segment three-way junction structure that is preferentially bound by RHA in support of efficient reverse transcription, the hallmark step of HIV-1 replication.

59 BASIC BIOLOGICAL SCIENCES↗

A Novel Three-Phase Oak Ridge AC / AC Converter for Wireless Mobility Energy Storage System (WMESS) Connectivity

In this study, a novel three-phase Oak Ridge ac to ac converter is introduced for wireless mobility energy storage system (WMESS) applications for grid support or ancillary service applications. The proposed topology can be used in bidirectional operation between ac grid and ac terminals of energy storage (output of the ESS inverter) by accomplishing unity power factor. Inherent merit of the technology is that it can directly merge ac input 60 Hz grid frequency with the high frequency by superimposing them with the Oak Ridge Converter (ORC) and through the wireless coils. Theoretical and simulation results are provided for 10 kW output power. The functionality of the proposed three-phase system is demonstrated with the coupling coils separated by 6 inches of air gap with the input / output of 277 V AC,RMS . The system overall design is presented, and simulation results demonstrate achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load of 10 kW wireless power transfer.

Asa, Erdem↗

A Novel Three Phase Oak Ridge DC / AC Converter for Wireless Grid Tied Applications

In this study, a novel three phase oak ridge dc to ac converter is introduced for wireless mobility energy storage (WMES) applications to support the grid demand during peak times. The proposed topology can be used in a bi-directional operation between ac grid and dc terminals of energy storage by accomplishing unity power factor. Inherent merit of the technology can directly merge dc input to the high frequency and 60 Hz grid frequency by superimposing through the wireless coils. Theoretical and simulation results are validated by the simulation analysis for 20 kW output power. The functionality of the proposed three phase system is established by using 6 inches air gap between the couplers with the input of 675 V DC and output of 277 V AC, RMS . The system overall design analysis is demonstrated for simulation analysis and simulation results are presented achieving 3% current total harmonic distortion (THD) and 0.99 power factor (PF) at full load 20 kW wireless power transfer.

Asa, Erdem↗

Developing Near Optimal Control Sequences for Chiller Plants with Water-side Economizers: A Case Study in a Warm and Marine Climate

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the optimization of those controls is limited. It is possible to maximize energy savings by developing near-optimal control sequences, which are dependent on several factors such as the load profile. To address these gaps, we first identify an advanced control sequence and three key control parameters for chiller plants with WSE. Next, optimizations are performed to minimize energy consumption for seven combinations of control parameters. A chiller plant with WSE system in a warm and marine climate is studied and two load profiles are considered. The system and controls are modeled using the Modelica Buildings library. The results show optimizing the selected control parameters can reduce energy consumption by up to 11% depending on the load profile. Specifically, optimizing the cooling tower efficiency threshold in the condenser water reset control can significantly reduce energy savings for the variable load profile by efficiently shifting the load from the cooling tower to the chiller. This paper provides practical guidance for developing near-optimal control sequences for chiller plant with WSE systems considering impacts such as the load profile.

chiller plant↗

Variability and Diversity Load Model Tool [SWR-20-03]

The motivation for the development of this tool and the underlying algorithms and methods was to enable the development of high-temporal resolution, realistic time-series data for quasi-static time-series (QSTS) analysis of distribution systems. Often, aggregated load profile data for a distribution circuit is available (e.g. feeder loading data collected via SCADA at the utility substation) and, while this data is typically accurate it masks the considerable variability of the 100’s or 1000’s of individual loads connected on the circuit. This tool was developed to model both the increased variability expected for these individual loads (e.g. the load of a single distribution transformer connected to 8-12 houses) and the expected diversity between loads on the circuit. It is important to note that the difference in variability and diversity, in the context of this tool, is that variability modeling only adds representative variability due to disaggregated load characteristics (e.g. the presence in the load profile of loads turning off and on like an air conditioner/oven) while the average energy profile remains the same as the user supplied power profile. Diversity modeling generates multiple individual load profiles which, in aggregate, sum to the user supplied power profile. Diversity is effectively variability in the energy usage over longer periods of time than seen in the variability model. Put another way, variability modeling supplies the expected variability due to the operation of various end-use loads and diversity modeling supplies the usage differences due to human behavior, schedules, etc. This load modeling tool was developed for use in generating data for distribution systems. Modeling is summarized by two major functions: 1) taking low resolution load profiles and adding intra-seconds variability onto the profiles, and 2) taking a user supplied load profile and distribution factors and adding both diversity and variability to the user supplied profile.

Zhu, Xiangqi↗