Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load component”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modal Survey of ETM-3, A 5-Segment Derivative of the Space Shuttle Solid Rocket Booster

The complex interactions between internal motor generated pressure oscillations and motor structural vibration modes associated with the static test configuration of a Reusable Solid Rocket Motor have potential to generate significant dynamic thrust loads in the 5-segment configuration (Engineering Test Motor 3). Finite element model load predictions for worst-case conditions were generated based on extrapolation of a previously correlated 4-segment motor model. A modal survey was performed on the largest rocket motor to date, Engineering Test Motor #3 (ETM-3), to provide data for finite element model correlation and validation of model generated design loads. The modal survey preparation included pretest analyses to determine an efficient analysis set selection using the Effective Independence Method and test simulations to assure critical test stand component loads did not exceed design limits. Historical Reusable Solid Rocket Motor modal testing, ETM-3 test analysis model development and pre-test loads analyses, as well as test execution, and a comparison of results to pre-test predictions are discussed.

Nielsen, D.↗

Seasonal Seismicity in the Lake Biwa Region of Central Japan Moderately Modulated by Lake Water Storage Changes

Seasonal seismicity in Japan has been observed and attributed to variations induced by hydrological loading, as well as atmospheric and pore-fluid pressure. We examine the seasonal variations of crustal (<15 km depth) and low magnitude (M < 4.5) earthquakes in central Japan near the Biwako-Seigan Fault Zone (BSFZ), and analyze their correlation with the annual hydrological cycle of nearby Lake Biwa, the largest freshwater lake in Japan. The 2002–2018 lake water storage is estimated using water-level gauge and satellite altimetry data. Regional surface mass loading from soil moisture and snow predicted by the Global Land Data Assimilation System is used to augment the lake mass variation. We compute the stress and stressing-rate changes induced by the surface mass loading from lake storage, snow, and soil moisture at seismogenic depth (10 km) along the BSFZ using a finite element model incorporating a 3D Earth structure. The results show that seasonal surface mass loading generates 1–5 kPa peak-to-peak Coulomb stress change and 2.5–15 kPa/year stressing-rate variations on the fault segments along the BSFZ. Two of the four fault segments present significant correlation between local seismicity rate and loading-derived stress and/or stressing rate changes. Among the hydrological load components, lake water, snow, and soil moisture exhibit different annual phases, and the lake water storage dominates the total annual stress changes. Our analysis indicates that seasonal surface hydrological loads, especially lake water variations, modulate the seismicity rate along the BSFZ in central Japan.

58 GEOSCIENCES↗

Multivariate exploration of non-intrusive load monitoring via spatiotemporal pattern network

Non-intrusive load monitoring (NILM) of electrical demand for the purpose of identifying load components has thus far mostly been studied using univariate data, e.g., using only whole building electricity consumption time series to identify a certain type of end-use such as lighting load. However, using additional variables in the form of multivariate time series data may provide more information in terms of extracting distinguishable features in the context of energy disaggregation. In this work, a novel probabilistic graphical modeling approach, namely the spatiotemporal pattern network (STPN) is proposed for energy disaggregation using multivariate time-series data. The STPN framework is shown to be capable of handling diverse types of multivariate time-series to improve the energy disaggregation performance. The technique outperforms the state of the art factorial hidden Markov models (FHMM) and combinatorial optimization (CO) techniques in multiple real-life test cases. Furthermore, based on two homes' aggregate electric consumption data, a similarity metric is defined for the energy disaggregation of one home using a trained model based on the other home (i.e., out-of-sample case). The proposed similarity metric allows us to enhance scalability via learning supervised models for a few homes and deploying such models to many other similar but unmodeled homes with significantly high disaggregation accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of Strain Gauge Coatings on Water Intrusion in Submerged Composite Coupon Testing

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand their combined effects, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Strain measurements are critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions is not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure (SGF), strains, and SGF modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The coatings did not have significant effects on composite fatigue life or strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite materials↗

Dissolved organic matter transport reflects hillslope to stream connectivity during snowmelt in a montane catchment

Dissolved organic matter (DOM) transport is a key biogeochemical linkage across the terrestrial-aquatic interface in headwater catchments, and quantifying the biological and hydrological controls on DOM composition provides insight into DOM cycling at the catchment scale. In this paper, we evaluated the mobility of DOM components during snowmelt in a montane, semiarid catchment. DOM composition was evaluated on a near-daily basis within the soil and the stream during snowmelt, and was compared to groundwater samples using a site-specific parallel factor analysis (PARAFAC) model derived from soil extracts. The fluorescent component loadings in the interstitial soil water and in the groundwater were significantly different and did not temporally change during snowmelt. In the stream, a transition occurred during snowmelt from fluorescent DOM with higher contributions of amino acid-like components indicative of groundwater to higher humic-like contributions indicative of soil water. Furthermore, we identified a humic-like fluorescent component in the soil water and the stream that is typically only observed in extracted water soluble organic matter from soil which may suggest hillslope to stream connectivity over very short time scales. Qualitative interpretations of changes in stream fluorescent DOM were supported by two end-member mixing analyses of conservative tracers. After normalizing fluorescent DOM loadings for dissolved organic carbon (DOC) concentration, we found that the peak in DOC concentration in the stream was driven by the nonfluorescent fraction of DOM. Finally, this study demonstrated how PARAFAC analysis can be used to refine our conceptual models of runoff generation sources, as well as provide a more detailed understanding of stream chemistry dynamics.

58 GEOSCIENCES↗

Robust Time-Varying Parameter Identification for Composite Load Modeling

With the increasing integration of uncertain resources, e.g., renewables, electric vehicles, and demand responses, it is imperative to understand the characteristics of loads for power system analysis and control. Challenges of load modeling come from a variety of load components and time-varying compositions. In addition, the existence of outliers in measurements further complicates the problem. This paper proposes a robust time-varying parameter identification technique for composite ZIP and induction motor load models. A batch-model regression form, including time-varying parameters, is established based on state transition models and observation models with current observations and previous predictions to guarantee data redundancy. To deal with outliers, down-weighting coefficients of measurements are calculated with a projection statistics approach. Based on the batch-model regression and the down-weighting coefficients, parameter identification at each sample time is formulated as a weighted least squares optimization, which is solved by the Newton-Raphson approach with the previous estimated parameters as the initial iteration values. In addition, parameters' sensitivities to different outliers in measurements are analyzed. Results on the IEEE 57-bus system and IEEE 118-bus system show that the proposed algorithm can robustly identify time-varying parameters for the composite load models.

Composite load model↗

Reducing Undue Conservatism in "Higher Frequency" Structural Design Loads in Aerospace Components

This study is intended to investigate the frequency dependency of significant strain due to vibratory loads in aerospace vehicle components. The notion that "higher frequency" dynamic loads applied as static loads is inherently conservative is perceived as widely accepted. This effort is focused on demonstrating that principle and attempting to evolve methods to capitalize on it to mitigate undue conservatism. It has been suggested that observations of higher frequency modes that resulted in very low corresponding strain did so due to those modes not being significant. Two avionics boxes, one with its first significant mode at 341 Hz and the other at 857 Hz, were attached to a flat panel installed on a curved orthogrid panel which was driven acoustically in tests performed at NASA/MSFC. Strain and acceleration were measured at select locations on each of the boxes. When possible, strain gage rosettes and accelerometers were installed on either side of a given structural member so that measured strain and acceleration data would directly correspond to one another. Ultimately, a frequency above which vibratory loads can be disregarded for purposes of static structural analyses and sizing of typical robust aerospace components is sought.

Knight, J. Brent↗

Effects of Coatings on Water Intrusion and Strain Gauge Durability in Submerged Fatigue Conditions: Preprint

Marine energy structures are typically made using composite materials and are repeatedly loaded by currents and waves. Submersion and repeated loading lead to two environmental effects: moisture intrusion and mechanical fatigue. To understand the combined effects of moisture intrusion and mechanical fatigue on marine energy structures, submerged fatigue testing can be used. Submerged fatigue testing often requires submerged instrumentation to validate component manufacturing methods and models. Measuring strain is critical for understanding marine energy component loads. One common method for measuring strain is by using foil strain gauges, but the durability of strain gauges in submerged fatigue conditions was not well-understood. To increase strain gauge durability and protection from contamination, delamination, and water intrusion, strain gauge coatings may be applied over strain gauges and wire connections. In this study, strain gauges were adhered to composite coupons, coated, and mechanically tested in a water tank. Cycles to composite failure, cycles to strain gauge failure, strains, and strain gauge failure modes were used to measure the effects of strain gauge coatings on composite fatigue life and strain gauge durability. The methods developed and measurements taken at the coupon scale in this study will be used to inform methods and designs for subsequent submerged subcomponent testing, full-scale testing, and standards development. The benefits of designing marine energy structures to informed standards and designs are decreased lifetime costs and increased reliability and energy production, ultimately leading to a sustainable and low-carbon energy system.

composite fatigue testing↗

Combined Load Diagram for a Wind Tunnel Strain-Gage Balance

Combined Load Diagrams for Direct-Read, Force, and Moment Balances are discussed in great detail in the paper. The diagrams, if compared with a corresponding combined load plot of a balance calibration data set, may be used to visualize and interpret basic relationships between the applied balance calibration loads and the load components at the forward and aft gage of a strain-age balance. Lines of constant total force and moment are identified in the diagrams. In addition, the lines of pure force and pure moment are highlighted. Finally, lines of constant moment arm are depicted. It is also demonstrated that each quadrant of a Combined Load Diagram has specific regions where the applied total calibration force is at, between, or outside of the balance gage locations. Data from the manual calibration of a Force Balance is used to illustrate the application of a Combined Load Diagram to a realistic data set.

Ulbrich, N.↗

Meta-Study of Particulate Detection Losses on Radioactive Air Sample Filters

Several mathematical relationships between air sample filter mass loading and the correlated analytical self-absorption factor were developed using data from other published research in this meta-study. Gross-alpha and -beta applications are addressed for this research. As filter media becomes loaded with particulate matter, there is potential for measurement losses due to self-absorption by mass loading. Components contributing to absorption include particulate dust, radioactive particulates, and filter material. Standards indicate a correction factor should be used when the penetration of radioactive material into the collection media or self-absorption of radiation by the material collected would reduce the detection rate by more than 5%. Previously, losses due to self-absorption have been reported up to 100% over a range up to ~10 mg∙cm -2 mass loading. These absorption losses then can be used to determine a correction factor for sample results. For low mass loadings (e.g., ≤0.1 mg∙cm -2 ) corrections factors in the 0.85 - 1 range have been recommended and used, while at higher mass loadings nearer to 10 mg∙cm -2 correction factors closer to 0 (representing near 100% losses) are used. Based on data from published studies, the different methods for relating percent loss due to self-absorption to mass loading include linear, exponential, quadratic, and trinomial derived functions. Where applicable, both forced zero and non-forced zero results were evaluated. From the derived functions evaluated, the trinomial function provided the best fit. Once the sample filter mass loading is known, the trinomial function can be applied to estimate losses and the corresponding self-absorption factor. When applied to routine operating conditions for radiological facility stacks monitored at the Pacific Northwest National Laboratory for an average sample filter mass loading of 0.09 ± 0.12 (2σ) mg∙cm -2 (excluding negative values and outliers) and a range from 0 - 0.24 mg∙cm -2 , the estimated trinomial function nominal self-absorption losses are less than 5% at 0.09 mg∙cm -2 and less than 10% at 0.24 mg∙cm -2 . The trinomial function is one method that may be used to adjust the activity results of an air sample when the sample-specific mass loading is determined. The application of no correction factor when the ANSI/HPS N13.1-2021 guidance of a 5% threshold for loss is not reached with typical stack sample mass loadings may be reasonable in high-efficiency particulate air filtered systems. For simplicity, it would be conservative in assigning the self-absorption correction factor at the 5% threshold (i.e., 0.95) for general uses but in cases of heavy mass loading to calculate the factor.

air sampling↗

Finite element approximations in transient analysis

Alternative techniques for finite element models for transient analyses are explored, using as an example a pinned-pinned beam. Attention is given to the relationships between desired accuracy and the available computer resources. Stiffness, mass, damping, and loading components approximations are examined with note taken of optimization methods. Generation of regular grid results indicates a linear relationship between the number of elements or degrees of freedom and the number of eigenvalues for a given accuracy. Comparisons of the finite element models in terms of accuracy/element or accuracy/degree of freedom were found to be inaccurate for determining model efficiency. Higher accuracies were available from lumped mass and damping models than assumptions of consistent loading, which was preferred to statically equivalent loading.

Melosh, R. J.↗

Hydrogen pipeline compressors annual progress report.

The objectives are: (1) develop advanced materials and coatings for hydrogen pipeline compressors; (2) achieve greater reliability, greater efficiency, and lower capital in vestment and maintenance costs in hydrogen pipeline compressors; and (3) research existing and novel hydrogen compression technologies that can improve reliability, eliminate contamination, and reduce cost. Compressors are critical components used in the production and delivery of hydrogen. Current reciprocating compressors used for pipeline delivery of hydrogen are costly, are subject to excessive wear, have poor reliability, and often require the use of lubricants that can contaminate the hydrogen (used in fuel cells). Duplicate compressors may be required to assure availability. The primary objective of this project is to identify, and develop as required, advanced materials and coatings that can achieve the friction, wear, and reliability requirements for dynamically loaded components (seal and bearings) in high-temperature, high-pressure hydrogen environments prototypical of pipeline and forecourt compressor systems. The DOE Strategic Directions for Hydrogen Delivery Workshop identified critical needs in the development of advanced hydrogen compressors - notably, the need to minimize moving parts and to address wear through new designs (centrifugal, linear, guided rotor, and electrochemical) and improved compressor materials. The DOE is supporting several compressor design studies on hydrogen pipeline compression specifically addressing oil-free designs that demonstrate compression in the 0-500 psig to 800-1200 psig range with significant improvements in efficiency, contamination, and reliability/durability. One of the designs by Mohawk Innovative Technologies Inc. (MiTi{reg_sign}) involves using oil-free foil bearings and seals in a centrifual compressor, and MiTi{reg_sign} identified the development of bearings, seals, and oil-free tribological coatings as crucial to the successful development of an advanced compressor. MiTi{reg_sign} and ANL have developed potential coatings for these rigorous applications; however, the performance of these coatings (as well as the nickel-alloy substrates) in high-temperature, high-speed hydrogen environments is unknown at this point.

08 HYDROGEN↗

Resilient and Corrosion-Proof Rolling Element Bearings Made from Superelastic Ni-Ti Alloys for Aerospace

Mechanical components (bearings, gears, mechanisms) typically utilize hardened construction materials to minimize wear and attain long life. In such components, loaded contact points (e.g., meshing gear teeth, bearing balls-raceway contacts) experience high contact stresses. The combination of high hardness and high elastic modulus often leads to damaging contact stress and denting, particularly during transient overload events such as shock impacts that occur during the launching of space vehicles or the landing of aircraft. In this webinar, Dr. DellaCorte will introduce the results of a research project that employs a superelastic alloy, Ni-Ti for rolling element bearing applications. Bearings and components made from such alloys can alleviate many problems encountered in advanced aerospace applications and may solve many terrestrial applications as well

intermetallics↗

Effect of occupant behavior on peak cooling and dehumidification loads in typical and high-efficiency homes

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure, installing the ductwork in conditioned space, and improving the building's airtightness results in significant reductions in externally-driven sensible and latent cooling loads. As a building's efficiency is improved, occupant-related internal gains become a larger portion of the building sensible and latent loads. Additionally, internal gains are highly uncertain compared to other load components. In this study, we use a stochastic approach to simulate occupant-related internal gains and compare the internal gains to other sensible and latent heat sources in four house efficiency levels in 10 U.S. climates using whole-building energy simulation software. We compare the expected range in occupant-related internal gains to other building characteristics such as cooling set point, air infiltration rate, and mechanical ventilation rate. We show that in high-efficiency homes, sensible internal gains vary from less than 10% to greater than 40% of the building sensible load under peak total cooling conditions depending on climate and internal gain profile. Likewise, latent internal gains vary from less than 10% to more than 60% of the building latent load under peak total cooling and peak dehumidification conditions depending on climate and internal gain profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parametric estimation of Poisson's ratio for thin hinged-hinged plates

Cornu's method is an elegant calculation besieged by an impractical approach to obtain accurate estimates for Poisson's ratio. Conventionally, Cornu's method requires several components, and each component can adversely affect the accuracy of the measurement. Furthermore, Cornu's conventional method requires a long beam because beams with short length-to-width ratios cause the estimate of Poisson's ratio to diverge from the true value of Poisson's ratio. We believe that, with the right modifications, Cornu's method can become an attractive approach to obtaining precise estimates for Poisson's ratio from mode shapes. Here we use finite element simulations to show how to use Cornu's method to estimate Poisson's ratio from a mode shape. Our modified Cornu's method removes knife-edges and loading components for a hinged-hinged plate under steady-state excitation. Given the true value of Poisson's ratio, as a performance specification, we show that simple parametric expressions can fit estimates for Poisson's ratio for different length-to-width ratios of thin hinged-hinged plates. Additionally, we show that estimates for Poisson's ratio from higher modes align with the results from the first mode and explain our expectation for this outcome. Furthermore, our results challenge the idea that anticlastic, monoclastic, and synclastic deformation uniquely correspond to positive, zero, and negative estimates of Poisson's ratio, respectively. With the emergence of materials-by-design, we expect that this parametric technique will be able to assist in experimental qualification of thin beam and plate structures with respect to the desired value of Poisson's ratio.

42 ENGINEERING↗

An active homopolar magnetic bearing with high temperature superconductor (HTS) coils and ferromagnetic cores

A proof-of-feasibility demonstration showed that high temperature superconductor (HTS) coils can be used in a high-load, active magnetic bearing in liquid nitrogen. A homopolar radial bearing with commercially wound HTS (Bi 2223) bias and control coils produced over 200 lb (890 N) radial load capacity (measured non-rotating) and supported a shaft to 14000 rpm. The goal was to show that HTS coils can operate stably with ferromagnetic cores in a feedback controlled system at a current density similar to that in Cu in liquid nitrogen. Design compromises permitted use of circular coils with rectangular cross section. Conductor improvements will eventually permit coil shape optimization, higher current density and higher bearing load capacity. The bias coil, wound with non-twisted, multifilament HTS conductor, required negligible power to carry its direct current. The control coils were wound with monofilament HTS sheathed in Ag. These dissipated negligible power for direct current (i.e. for steady radial load components). When an alternating current (AC) was added, the AC component dissipated power which increased rapidly with frequency and quadratically with AC amplitude. In fact at frequencies above about 2 hz, the effective resistance of the control coil conductor actually exceeds that of the silver which is in electrical parallel with the oxide superconductor. This is at least qualitatively understandable in the context of a Bean-type model of flux and current penetration into a Type II superconductor. Fortunately the dynamic currents required for bearing stability are of small amplitude. These results show that while twisted multifilament conductor is not needed for stable levitation, twisted multifilaments will be required to reduce control power for sizable dynamic loads, such as those due to unbalance.

Brown, G. V.↗

Constant current load matches impedances of electronic components

Constant current load with negative resistance characteristics actively compensates for impedance variations in circuit components. Through a current-voltage balancing operation the internal impedance of the diodes is maintained at a constant value. This constant current load circuit can be used in simple telemetry systems.

Alexander, R. M.↗

Wire-coil insert optimization for high-heat-load/flux synchrotron components

Many synchrotron components require high levels of internal-flow, forced-convection heat transfer to minimize surface temperatures, thermal gradients, and thermally induced stress on high-power beam-interacting surfaces. Wire-coil inserts, physically similar to a common spring, are mechanically fitted inside of component cooling passages to optimize heat transfer performance. They are routinely used in Advanced Photon Source (APS) front end and beamline high-heat-load/flux components to significantly enhance convection heat transfer-up to 400% compared to plain open passages. This has the additional benefit of greatly reducing coolant flow requirements for these components. Using several cooling passage sizes, five different wire sizes, and a range of pitch values, an experimental investigation conducted at the APS has determined the average heat transfer coefficient and resulting pressure loss as a function of water flow rate for 65 different wire-coil inserts. Data from this study have been non-dimensionalized and generalized to yield relationships that can be used to determine the heat transfer performance and resulting pressure loss for any given wire-coil insert that may be used at the APS. Through data reduction, the wire-coil insert characteristic dimensions have also been optimized to yield the highest heat transfer enhancement while minimizing the coolant flow requirements. These generalized expressions for wirecoil inserts will be presented, and they can be used by scientists and engineers during the component design process to evaluate achievable heat transfer performance and associated pressure loss, aiding in the establishment of optimized operating parameters and cooling passage flow distribution schemes.

43 PARTICLE ACCELERATORS↗