Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid cooling system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fission Surface Power Technology Demonstration Unit Test Results

The Fission Surface Power (FSP) Technology Demonstration Unit (TDU) is a system-level demonstration of fission power technology intended for use on manned missions to Mars. The Baseline FSP systems consists of a 190 kWt UO2 fast-spectrum reactor cooled by a primary pumped liquid metal loop. This liquid metal loop transfers heat to two intermediate liquid metal loops designed to isolate fission products in the primary loop from the balance of plant. The intermediate liquid metal loops transfer heat to four Stirling Power Conversion Units (PCU), each of which produce 12 kWe (48 kW total) and reject waste heat to two pumped water loops, which transfer the waste heat to titanium-water heat pipe radiators. The FSP TDU simulates a single leg of the baseline FSP system using an electrically heater core simulator, a single liquid metal loop, a single PCU, and a pumped water loop which rejects the waste heat to a Facility Cooling System (FCS). When operated at the nominal operating conditions (modified for low liquid metal flow) during TDU testing the PCU produced 8.9 kW of power at an efficiency of 21.7% resulting in a net system power of 8.1 kW and a system level efficiency of 17.2%. The reduction in PCU power from levels seen during electrically heated testing is the result of insufficient heat transfer from the NaK heater head to the Stirling acceptor, which could not be tested at Sunpower prior to delivery to GRC. The maximum PCU power of 10.4 kW was achieved at the maximum liquid metal temperature of 875 K, minimum water temperature of 350 K, 1.1 kg/s liquid metal flow, 0.39 kg/s water flow, and 15.0 mm amplitude at an efficiency of 23.3%. This resulted in a system net power of 9.7 kW and a system efficiency of 18.7 %.

fission power technology↗

Cryogenic liquid transfer system reduces residual boiloff

System for transferring cryogenic liquids to a dewar prevents boiloff of residual liquid by venting the boiloff to the atmosphere during the transfer tube cooling period. The system is most useful with liquids having very small heat of vaporization.

Hegland, D. E.↗

The helium system of the maser installation at the Goonhilly satellite-communication earth station

A travelling-wave solid-state maser anlplifier is used to provide the first stage of amplification in the receiving system at the communication-satellite earth-station at Goonhilly Downs. While the maser itself was built by an industrial research laboratory, the auxiliary supplies and equipment essential for the operation of the maser were designed and built by staff of the Post Office Research Station. A major part of this auxiliary equipment consists of apparatus for handling the helium refrigerant.

GROUND STATION↗

Using Liquid Natural Gas Fuel to Cryogenically Cool and Enhance a Hybrid Electric Aircraft Power System

A previous system study identified significant increases in range and number of urban air mobility (UAM) missions by replacing the all battery power system of a notional UAM vehicle with an advanced diesel hybrid using conventional diesel or liquid natural gas (LNG) fuels (at constant vehicle design gross weight). Some benefits were realized using the LNG's cryogenic properties to reduce some electrical component losses and cooling requirements. Significant questions were raised concerning volume and thermal management considerations for all studied systems. The notional, baseline vehicle was a hybrid helicopter / airplane design capable of vertical take-off and landing (VTOL), balancing high cruise efficiency with reasonable hover capability. A subsequent power system assessment using the same notional vehicle and mission was performed that identified increased volume and power requirements for the active cooling required. The cooling airflow could also generate additional drag on the vehicle during operation. For the notional vehicle studied, the additional volume identified by the subsequent study would not affect vehicle mold line and therefore drag. However, the additional drag from cooling airflow and the power to circulate it as needed would impact power system and vehicle mission performance. Vehicle and mission models were updated and rerun. Updated results still indicated significant benefits in range and number of UAM missions, but reduced the benefit by 12-15%. Hold time for the hybrid systems also generally increased a few minutes because of reduced power available for charging from the power for required cooling flows. Vehicle weights, thermal loads, and cooling airflows from the updated analyses were similar to previous results.

systems analysis↗

Hemodynamic and Thermal Responses to Head and Neck Cooling in Men and Women

Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. Configurations of these systems include passive ice vests and circulating liquid cooling garments (LCGs) in the forms of vests, cooling caps and combined head and neck cooling systems. However, little information is available oil the amount or heat that can be extracted from the body with these systems or the physiologic changes produced by routine operation of these systems. The objective of this study was to determine the operating characteristics and the physiologic change, produced by short term use of one commercially available thermal control system.

Ku, Yu-Tsuan E.↗

You can't eat moon rocks

The effects produced by the aerospace program are investigated. The technology developed from aerospace-related research, development, and manufacturing has been made available to the public for its use through the NASA Technology Utilization Program. A description is presented of 'spinoffs' of NASA's aerospace programs which are used on a daily basis by the public. Attention is given to the liquid cooled garment technology, meal systems for the elderly, the zinc-rich coating, the emergency blanket, the flexible urethane foam Temper Foam, the 'Fog-Away Coating', and composite graphite equipment.

Kubokawa, C. C.↗

Study of solid state photomultiplier

Available solid state photomultiplier (SSPM) detectors were tested under low-background, low temperature conditions to determine the conditions producing optimal sensitivity in a space-based astronomy system such as a liquid cooled helium telescope in orbit. Detector temperatures varied between 6 and 9 K, with background flux ranging from 10 to the 13th power to less than 10 to the 6th power photons/square cm-s. Measured parameters included quantum efficiency, noise, dark current, and spectral response. Experimental data were reduced, analyzed, and combined with existing data to build the SSPM data base included herein. The results were compared to analytical models of SSPM performance where appropriate models existed. Analytical models presented here were developed to be as consistent with the data base as practicable. Significant differences between the theory and data are described. Some models were developed or updated as a result of this study.

Hays, K. M.↗

Heat pipe cooling for scramjet engines

Liquid metal heat pipe cooling systems have been investigated for the combustor liner and engine inlet leading edges of scramjet engines for a missile application. The combustor liner is cooled by a lithium-TZM molybdenum annular heat pipe, which incorporates a separate lithium reservoir. Heat is initially absorbed by the sensible thermal capacity of the heat pipe and liner, and subsequently by the vaporization and discharge of lithium to the atmosphere. The combustor liner temperature is maintained at 3400 F or less during steady-state cruise. The engine inlet leading edge is fabricated as a sodium-superalloy heat pipe. Cooling is accomplished by radiation of heat from the aft surface of the leading edge to the atmosphere. The leading edge temperature is limited to 1700 F or less. It is concluded that heat pipe cooling is a viable method for limiting scramjet combustor liner and engine inlet temperatures to levels at which structural integrity is greatly enhanced.

Silverstein, Calvin C.↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aerodynamics↗

NASA’s Quiet Electric ENgines (QUEEN): Summary of the QUEEN V2 Test

A liquid-cooled electric ducted fan system was designed, built, and tested at the NASA Glenn Research Center. Main components of the system include a Commercial-Off- the-Shelf (COTS) fan and motor, and a custom-designed heat exchanger integrated into the fan duct. Fan speed, thrust, and cooling system thermal performance was measured in this static ground test of the propulsor. This propulsor prototype is one of NASA’s Quiet Electric ENgines (QUEENs) and is designated the ‘QUEEN V2.’ The Quiet Electric Engines are being developed for the 25% scale model of the Subsonic Aft Engine (SUSAN) Flight Research Vehicle and are intended to explore the potential of distributed electric propulsion for regional single-aisle aircraft. This test demonstrated the functionality of the QUEEN V2, quantified the thrust produced by the electrofan, and characterized the electrical and thermal performance of the system. Lessons learned will be used to guide development of future QUEEN prototypes.

Aeronautics-General↗

Artemis II Mission Performance of the Orion Active Thermal Control System

The Orion spacecraft has recently completed Artemis II, the first crewed mission around the moon in 54 years. This test flight demonstrated vehicle capability as the foundation for all future missions under the Artemis program. As a major system of Orion, the Active Thermal Control System (ATCS) successfully managed crew and vehicle heat loads to provide adequate cooling and thermal comfort for the duration of the Artemis II mission. Thermal control on the Orion vehicle is managed through two redundant cooling loops in the Crew Module (CM) that absorb heat loads from the cabin and Air Revitalization System (ARS) heat exchangers, the Liquid Cooling Garment (LCG) heat exchanger, and the avionics cold plates, and then transfer those heat loads to the Service Module (SM) radiator loops and/or the Phase Change Material (PCM) and ammonia boilers when required through thermal configuration or mission phase. During Artemis II, Orion did not necessitate any supplemental cooling from ammonia boilers until service module separation, allowing the maximum availability of ammonia cooling prior to entry. This presentation will provide an overview of the Orion ATCS major subsystems, highlight the performance during key mission phases, and comment on the applicability of the observed thermal response to future Artemis missions.

Ellie Thurston↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

Molecular absorption cryogenic cooler for liquid hydrogen propulsion systems

A light weight, long life molecular absorption cryogenic cooler (MACC) system is described which can use low temperature waste heat to provide cooling for liquid hydrogen propellant tanks for interplanetary spacecraft. Detailed tradeoff studies were made to evaluate the refrigeration system component interactions in order to minimize the mass of the spacecraft cooler system. Based on this analysis a refrigerator system mass of 31 kg is required to provide the .48 watts of cooling required by a 2.3 meter diameter liquid hydrogen tank.

Klein, G. A.↗