Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “lightning flash density”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

88 records · Page 5

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytic framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19 month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological impulsive VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). The underlying vertical distribution of impulsive VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within a 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose standard deviation increases as r(exp 2). Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic estimates. LDAR bulk flash detection efficiency is predicted to be above 90% to 94-113 km range from the network centroid and to fall below 10% at ranges greater than 200-240 km.

Boccippio, D. J.↗

Transfer of electrical space charge from corona between ground and thundercloud: Measurements and modeling

The evolution of the vertical electric field profile deduced from simultaneous field measurements at several levels below a thundercloud shows the development of a space charge layer at least up to 600 m. The average charge density in the whole layer from 0 m to 600 m can reach about 1 nC m(exp -3). The ions are generated at the ground by corona effect and the production rate is evaluated with a new method from the comparison of field evolutions at the ground and at altitude after a lightning flash. The modeling of the relevant processes shows tht ground corona accounts for the observed field evolutions and that the aerosol particles concentration has a very large effect on the evolution of corona ions. However, with a realistic value for this concentration a large amount of ground corona ions reach the level of 600 m.

Soula, Serge↗

Forecasting Lightning Threat Using WRF Proxy Fields

Objectives: Given that high-resolution WRF forecasts can capture the character of convective outbreaks, we seek to: 1. Create WRF forecasts of LTG threat (1-24 h), based on 2 proxy fields from explicitly simulated convection: - graupel flux near -15 C (captures LTG time variability) - vertically integrated ice (captures LTG threat area). 2. Calibrate each threat to yield accurate quantitative peak flash rate densities. 3. Also evaluate threats for areal coverage, time variability. 4. Blend threats to optimize results. 5. Examine sensitivity to model mesh, microphysics. Methods: 1. Use high-resolution 2-km WRF simulations to prognose convection for a diverse series of selected case studies. 2. Evaluate graupel fluxes; vertically integrated ice (VII). 3. Calibrate WRF LTG proxies using peak total LTG flash rate densities from NALMA; relationships look linear, with regression line passing through origin. 4. Truncate low threat values to make threat areal coverage match NALMA flash extent density obs. 5. Blend proxies to achieve optimal performance 6. Study CAPS 4-km ensembles to evaluate sensitivities.

McCaul, E. W., Jr.↗

Lightning danger and advanced warning times obtainable from field mills

The rate of charge moment generation derived from Maxwell current densities at the ground is compared with the rate of charge moment removal by lightning for the initial stages of a small thunderstorm cell. It is shown that the current moment in the cell increased with time at a rate of 4.5 (A m/s) during the first seven minutes following detection of electrical activity on the ground. At the time of the first lightning flash which neutralized 0.48 (kC m) a charge moment of over 8 (kC m) had been separated. Theoretical and practical implications of these measurements are discussed.

Nisbet, John S.↗

Evaluation of NASA SPoRT's Pseudo-Geostationary Lightning Mapper Products in the 2011 Spring Program

NASA's Short-term Prediction Research and Transition (SPoRT) program is a contributing partner with the GOES-R Proving Ground (PG) preparing forecasters to understand and utilize the unique products that will be available in the GOES-R era. This presentation emphasizes SPoRT s actions to prepare the end user community for the Geostationary Lightning Mapper (GLM). This preparation is a collaborative effort with SPoRT's National Weather Service partners, the National Severe Storms Laboratory (NSSL), and the Hazardous Weather Testbed s Spring Program. SPoRT continues to use its effective paradigm of matching capabilities to forecast problems through collaborations with our end users and working with the developers at NSSL to create effective evaluations and visualizations. Furthermore, SPoRT continues to develop software plug-ins so that these products will be available to forecasters in their own decision support system, AWIPS and eventually AWIPS II. In 2009, the SPoRT program developed the original pseudo geostationary lightning mapper (PGLM) flash extent product to demonstrate what forecasters may see with GLM. The PGLM replaced the previous GLM product and serves as a stepping-stone until the AWG s official GLM proxy is ready. The PGLM algorithm is simple and can be applied to any ground-based total lightning network. For 2011, the PGLM used observations from four ground-based networks (North Alabama, Kennedy Space Center, Oklahoma, and Washington D.C.). While the PGLM is not a true proxy product, it is intended as a tool to train forecasters about total lightning as well as foster discussions on product visualizations and incorporating GLM-resolution data into forecast operations. The PGLM has been used in 2010 and 2011 and is likely to remain the primary lightning training tool for the GOES-R program for the near future. This presentation will emphasize the feedback received during the 2011 Spring Program. This will discuss several topics. Based on feedback from the 2010 Spring Program, SPoRT created two variant PGLM products, which NSSL produced locally and provided in real-time within AWIPS for 2011. The first is the flash initiation density (FID) product, which creates a gridded display showing the number of flashes that originated in each 8 8 km grid box. The second product is the maximum flash density (MFD). This shows the highest PGLM value for each grid point over a specific period of time, ranging from 30 to 120 minutes. In addition to the evaluation of these two new products, the evaluation of the PGLM itself will be covered. The presentation will conclude with forecaster feedback for additional improvements requested for future evaluations, such as within the 2012 Spring Program.

Stano, Geoffrey T.↗

Nitrogen Oxides and Ozone from B-747 Measurements (NOXAR) During POLINAT-2 and SONEX: Overview and Case Studies on Continental and Marine Convection

In the framework of the project POLINAT 2 (Pollution in the North Atlantic Flight Corridor) we measured NO(x) (NO and NO2) and ozone on 85 flights through the North Atlantic Flight Corridor (NAFC) with a fully automated system permanently installed aboard an in-service Swissair B-747 airliner in the period of August to November 1997. The averaged NO(x) concentrations both in the NAFC and at the U.S. east coast were similar to that measured in autumn 1995 with the same system. The patchy occurrence of NO(x) enhancements up to 3000 pptv over several hundred kilometers (plumes), predominately found over the U.S. east coast lead to a log-normal NO(x) probability density function. In three case studies we examine the origins of such plumes by combining back-trajectories with brightness temperature enhanced (IR) satellite imagery, lightning observations from the U.S. National Lightning Detection Network (NLDN) and the Optical Transient Detector (OTD) satellite. We demonstrate that the location of NO(x) plumes can be well explained with maps of convective influence. We show that the number of lightning flashes in cluster of marine thunderstorms is proportional to the NO(x) concentrations observed several hundred kilometers downwind of the anvil outflows. From the fact that in autumn the NO(x) maximum was found several hundred kilometers off the U.S. east coast, it can be inferred that thunderstorms triggered over the warm Gulf Stream current are major sources for the regional upper tropospheric NO(x) budget in autumn.

Jeker, Dominique P.↗

Lightning-Generated Whistler Waves Observed by Probes On The Communication/Navigation Outage Forecast System Satellite at Low Latitudes

Direct evidence is presented for a causal relationship between lightning and strong electric field transients inside equatorial ionospheric density depletions. In fact, these whistler mode plasma waves may be the dominant electric field signal within such depletions. Optical lightning data from the Communication/Navigation Outage Forecast System (C/NOFS) satellite and global lightning location information from the World Wide Lightning Location Network are presented as independent verification that these electric field transients are caused by lightning. The electric field instrument on C/NOFS routinely measures lightning ]related electric field wave packets or sferics, associated with simultaneous measurements of optical flashes at all altitudes encountered by the satellite (401.867 km). Lightning ]generated whistler waves have abundant access to the topside ionosphere, even close to the magnetic equator.

Holzworth, R. H.↗

Characteristics of return stroke electric fields produced by lightning flashes at distances of 1 to 15 kilometers

Electric field derivative signals from single and multiple lightning strokes are presented. For about 25 pct. of all acquired waveforms, produced by return strokes, stepped leaders or intracloud discharges, type and distance of the signal source are known from the observations by an all sky video camera system. The analysis of the electric field derivative waveforms in the time domain shows a significant difference in the impulse width between return stroke signals and those of stepped leaders and intracloud discharges. In addition, the computed amplitude density spectrum of return stroke waveforms lies by a factor of 10 above that of stepped leaders and intracloud discharges in the frequency range from 50 to 500 kHz.

Hopf, CH.↗

Nitrogen Oxides and Ozones from B-747 Measurements (NOXAR) during POLINAT 2 and SONEX: Overview and Case-Studies on Continental and Marine Convection

In the framework of the project POLINAT 2 (Pollution in the North Atlantic Flight Corridor) we measured NO(x) (NO and NO2) and ozone on 98 flights through the North Atlantic Flight Corridor (NAFC) with a fully automated system permanently installed aboard an in-service Swissair B-747 airliner in the period of August to November 1997. The averaged NO, concentrations both in the NAFC and at the U.S. east coast were similar to that measured in autumn 1995 with the same system. The patchy occurrence of NO(x), enhancements up to 3000 pptv over several hundred kilometers (plumes), predominately found over the U.S. east coast lead to a log-normal NO(x) probability density function. In three case-studies we examine the origins of such plumes by combining back-trajectories with brightness temperature enhanced (IR) satellite imagery, with lightning observations from the U.S. National Lightning Detection Network (NLDN) or with the Optical Transient Detector (OTD) satellite. For frontal activity above the continental U.S., we demonstrate that the location of NO(x) plumes can be well explained with maps of convective influence. For another case we show that the number of lightning flashes in a cluster of marine thunderstorms is proportional to the NO(x) concentrations observed several hundred kilometers downwind of the anvil outflows and suggest that lightning was the dominant source. From the fact that in autumn the NO, maximum was found several hundred kilometers off the U.S. east coast, it can be inferred that thunderstorms triggered over the warm Gulf Stream current are an important source for the regional upper tropospheric NO(x) budget in autumn.

Jeker, Dominique↗

A Diagnostic Analysis of the Kennedy Space Center LDAR Network: Data Characteristics - 1

An analytical framework is developed in which to analyze climatological VHF (66 MHz) radiation measurements taken by the Kennedy Space Center Lightning Detection and Ranging (LDAR) network. A 19-month noise-filtered sample of LDAR observations is examined using this framework. It is found that the climatological VHF source density as observed by LDAR falls off approximately 10 dB every 71 km of ground range away from the network centroid (a 31 km e-folding scale). From this framework it is inferred that the underlying source distribution is likely inverse exponential in amplitude, with a log-slope of 126-147 mW(sup -1/2). The underlying vertical distribution of VHF sources is approximately normally distributed with a mean altitude of 9 km and a standard deviation of 2.7 km; this implies that the loss of below-horizon sources has a negligible effect on column-integrated source densities within 200 km ground range. At medium to far ranges, location errors are primarily radial and have a slightly asymmetric distribution whose first moment increases as range squared. Error moments estimated from observed lightning are significantly higher than those from aircraft-based signal generator or analytic solution estimates, suggesting that timing errors arising from poor signal identification and discrimination may dominate over timing errors arising from nominal sensor resolution. The VHF source properties of individual LDAR-observed flashes are computed and an analytic expression for flash detection efficiency vs. range is derived. This reveals nearly constant flash detection efficiency to 80-94 km range from the network centroid.

Boccippio, D. J.↗

Evaluation of Lightning Incidence to Elements of a Complex Structure: A Monte Carlo Approach

There are complex structures for which the installation and positioning of the lightning protection system (LPS) cannot be done using the lightning protection standard guidelines. As a result, there are some "unprotected" or "exposed" areas. In an effort to quantify the lightning threat to these areas, a Monte Carlo statistical tool has been developed. This statistical tool uses two random number generators: a uniform distribution to generate origins of downward propagating leaders and a lognormal distribution to generate returns stroke peak currents. Downward leaders propagate vertically downward and their striking distances are defined by the polarity and peak current. Following the electrogeometrical concept, we assume that the leader attaches to the closest object within its striking distance. The statistical analysis is run for 10,000 years with an assumed ground flash density and peak current distributions, and the output of the program is the probability of direct attachment to objects of interest with its corresponding peak current distribution.

Mata, Carlos T.↗

Evaluation of Lightning Incidence to Elements of a Complex Structure: A Monte Carlo Approach

There are complex structures for which the installation and positioning of the lightning protection system (LPS) cannot be done using the lightning protection standard guidelines. As a result, there are some "unprotected" or "exposed" areas. In an effort to quantify the lightning threat to these areas, a Monte Carlo statistical tool has been developed. This statistical tool uses two random number generators: a uniform distribution to generate the origin of downward propagating leaders and a lognormal distribution to generate the corresponding returns stroke peak currents. Downward leaders propagate vertically downward and their striking distances are defined by the polarity and peak current. Following the electrogeometrical concept, we assume that the leader attaches to the closest object within its striking distance. The statistical analysis is run for N number of years with an assumed ground flash density and the output of the program is the probability of direct attachment to objects of interest with its corresponding peak current distribution.

Mata, Carlos T.↗

Determination of a Limited Scope Network's Lightning Detection Efficiency

This paper outlines a modeling technique to map lightning detection efficiency variations over a region surveyed by a sparse array of ground based detectors. A reliable flash peak current distribution (PCD) for the region serves as the technique's base. This distribution is recast as an event probability distribution function. The technique then uses the PCD together with information regarding: site signal detection thresholds, type of solution algorithm used, and range attenuation; to formulate the probability that a flash at a specified location will yield a solution. Applying this technique to the full region produces detection efficiency contour maps specific to the parameters employed. These contours facilitate a comparative analysis of each parameter's effect on the network's detection efficiency. In an alternate application, this modeling technique gives an estimate of the number, strength, and distribution of events going undetected. This approach leads to a variety of event density contour maps. This application is also illustrated. The technique's base PCD can be empirical or analytical. A process for formulating an empirical PCD specific to the region and network being studied is presented. A new method for producing an analytical representation of the empirical PCD is also introduced.

Rompala, John T.↗

A thundercloud electric field sounding - Charge distribution and lightning

An instrumented free balloon measured electric fields and field changes as it rose through a thundercloud above Langmuir Laboratory, New Mexico. The variation of the electric field with altitude implied that the cloud contained negative space charge of density -0.6 to -4 nC/cu m between 5.5 and 8.0 km MSL. The environmental temperature at these levels ranged from -5 to -20 C. The measurements imply that the areal extent of this negative charge center was significantly greater than that of the cloud's intense precipitation shafts. At altitudes greater than 8 km, the instrument ascended past net positive charge. In addition, positive space charge adjacent to the earth's surface (concentration 0.6 nC/cu m and in the lowest portion of the cloud (1.0 nC/cu m) is inferred from the measurements. Electric field changes from intracloud lightning were interpreted by using a simple model for the developing streamer of the initial phase. Thunder source reconstructions provided estimates for the orientation of lightning channels. Seven 'streamers' so analyzed propagated on the average, at 50,000 m/s and carried a current of 390 A. The mean charge dissipated during a flash was 30 C.

Weber, M. E.↗

Automated Identification of Initial Storm Electrification and End-of-Storm Electrification Using Electric Field Mill Sensors

Kennedy Space Center (KSC) operations are located in a region which experiences one of the highest lightning densities across the United States. As a result, on average, KSC loses almost 30 minutes of operational availability each day for lightning sensitive activities. KSC is investigating using existing instrumentation and automated algorithms to improve the timeliness and accuracy of lightning warnings. Additionally, the automation routines will be warning on a grid to minimize under-warnings associated with not being located in the center of the warning area and over-warnings associated with encompassing too large an area. This study discusses utilization of electric field mill data to provide improved warning times. Specifically, this paper will demonstrate improved performance of an enveloping algorithm of the electric field mill data as compared with the electric field zero crossing to identify initial storm electrification. End-of-Storm-Oscillation (EOSO) identification algorithms will also be analyzed to identify performance improvement, if any, when compared with 30 minutes after the last lightning flash.

initial storm electrification↗

Lightning Jump Algorithm Development for the GOES·R Geostationary Lightning Mapper

Current work on the lightning jump algorithm to be used in GOES‐R Geostationary Lightning Mapper (GLM)'s data stream is multifaceted due to the intricate interplay between the storm tracking, GLM proxy data, and the performance of the lightning jump itself. This work outlines the progress of the last year, where analysis and performance of the lightning jump algorithm with automated storm tracking and GLM proxy data were assessed using over 700 storms from North Alabama. The cases analyzed coincide with previous semi‐objective work performed using total lightning mapping array (LMA) measurements in Schultz et al. (2011). Analysis shows that key components of the algorithm (flash rate and sigma thresholds) have the greatest influence on the performance of the algorithm when validating using severe storm reports. Automated objective analysis using the GLM proxy data has shown probability of detection (POD) values around 60% with false alarm rates (FAR) around 73% using similar methodology to Schultz et al. (2011). However, when applying verification methods similar to those employed by the National Weather Service, POD values increase slightly (69%) and FAR values decrease (63%). The relationship between storm tracking and lightning jump has also been tested in a real‐time framework at NSSL. This system includes fully automated tracking by radar alone, real‐time LMA and radar observations and the lightning jump. Results indicate that the POD is strong at 65%. However, the FAR is significantly higher than in Schultz et al. (2011) (50‐80% depending on various tracking/lightning jump parameters) when using storm reports for verification. Given known issues with Storm Data, the performance of the real‐time jump algorithm is also being tested with high density radar and surface observations from the NSSL Severe Hazards Analysis & Verification Experiment (SHAVE).

Schultz. E.↗