Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “leak test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

RELAP5-3D Simulation of PG-27 Test at the HTTF Facility

The High Temperature Test Facility (HTTF) at Oregon State University (OSU) is a quarter scaled integral-effect test facility designed to examine the transient phenomena occurring in a Modular Hight Temperature Gas-cooled Reactor (MHTGR). It is specifically designed to handle the pressurized and depressurized conduction cooldown (PCC and DCC) events. The PCC event is an accident scenario in which there is a loss of forced convection of the coolant through the system. However, the pressure boundary remains intact. This study focuses on the Reactor Excursions and Leak Analysis Program (RELAP)5-3D simulation of the PG-27 test (PCC phenomena) and the sensitivity of those simulations from the material properties and primary helium mass flow rate standpoint. The aim is to capture a reasonable one-dimensional picture of a three dimensional phenomena. The simulation will help in the code assessment and in understanding the various unknown parameters involved. The presented results will demonstrate the code is able to capture the detailed one-dimensional physics accurately. However, input parameters to the code (i.e., the primary mass flow rate, refractory material thermal conductivity, and heat capacity at elevated temperatures) impact the fuel temperature the most. This work will discuss the sensitivity of simulations to the identified input parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

The Qualification of Sealability and Creep Relaxation of Additively Manufactured Zytel Gaskets for PEM Fuel Cells

The purpose of this thesis is to study the feasibility of low-cost additive manufacturing of gaskets for proton exchange membrane fuel cells exposed to extreme temperature conditions ranging from -55°C to 100°C. With the growing popularity and decreasing costs of additive manufacturing technologies, specifically Material Extrusion (ME), research is being conducted to determine the feasibility of ME components. Thermally cycled PEMFCs may exhibit accelerated gasket deterioration, therefore, the mechanical stability of material extruded gaskets following a harsh thermal cycle must be assessed. The feasibility of the material extruded gaskets will be proven by manufacturing optimization and mechanical testing. The target material for this study is Zytel by DuPont Chemical. The mechanical stability will be assessed via sealability and creep relaxation testing according to ASTM F37B and ASTM F38B respectively. Because the capabilities to conduct sealability testing at temperature were not available, each specimen was thermally soaked and allowed to return to room temperature prior to testing. As a result of sealability experiments, the 100°C-soaked specimens resulted in lower leak rates with a higher precision when compared to specimens soaked at -55°C and 22°C at across all compressive loads. It was observed from results from creep relaxation testing that there is thermal contraction and expansion occurring at 55°C and 100°C respectively, which can be observed by the resultant graphs. The recoverability of thermally cycled specimens are better than those that just experienced a high temperature hold. After the seven-day thermal cycle, the samples stabilized and maintained their structure.

Lazarin, Robert↗

Full Submersion Water Testing of SAVY-4000 Nuclear Material Storage Containers

SAVY-4000 (SAVY) containers are the primary container used at Technical Area (TA) TA-55 plutonium facility for the prevention of water ingress to mitigate against a criticality event. The basis for water resistance of these containers has long been attributed to the Polytetrafluoroethylene (PTFE) membrane that is assembled on the outermost surface of the filter assembly. On August 22nd a test of a container used inside of a glovebox was performed that brought into question this long-standing-basis. This test was performed by inverting a SAVY-lid onto a specialized piece of equipment for evaluating the integrity of the PTFE membrane. During the test water was observed passing through the filter indicating that the filter membrane was no longer preventing the ingress of water through the filter. The assumption after making this observation was that alpha-particles were rapidly degrading the membrane creating a leak path through the underlying aluminosilicate media (Fiberfrax®). The apparatus used was designed to only test the lid rather than the entire SAVY assembly. A test plan, PA-PLAN-01921, was developed to investigate whether a fully assembled container with a fully degraded PTFE membrane would be capable of meeting the criteria defined in PA-RD-1009 of not allowing more than 200 ml of water to enter the container with a water column of 6-inches applied over a 2-hour period. This report provides the results of the testing performed against PA-PLAN-01921.

36 MATERIALS SCIENCE↗

NRAP-Open-IAM: Generic Aquifer Component Development and Testing

The Generic Aquifer Model calculates the concentrations of dissolved salt and dissolved CO 2 surrounding a leaking legacy well. The Generic Aquifer model can also estimate the size of an “impact plume” where concentration changes exceed user-specified thresholds. The model is a component of NRAP-Open-IAM, an open-source Integrated Assessment Model (IAM) developed by the National Risk Assessment Partnership (NRAP) to perform risk assessment for geologic CO 2 storage. The input parameters were selected to cover a wide range of groundwater aquifers and leakage rates. The generic aquifer model was developed using a generative adversarial deep learning network, trained using a large synthetic dataset of STOMP multiphase flow simulations. The deep learning model predictions of dissolved salt and dissolved CO 2 in the aquifer compare well to the original STOMP simulation results. The extent of aquifer impacted by leaking CO 2 or brine is calculated using a user-defined mass fraction threshold. The aquifer impact volumes calculated based on STOMP simulation results compare well to those calculated based on the deep learning model. In a provided python script, gridded observation results from the generic aquifer component of NRAP-Open-IAM are converted to HDF5 format files for monitoring design with the DREAM code.

54 ENVIRONMENTAL SCIENCES↗

Public data from three US states provide new insights into well integrity

Significance There are over 900,000 active oil and gas wells in the United States. Estimates of the percentage of these wells that leak during their lifetime have been limited by data availability. We mined publicly available records from state regulatory databases and synthesized the results of various well testing methods into a uniform dataset that describes the integrity of 105,031 wells. Our analysis of the dataset provides insight into regional well leakage frequencies in three US states (Colorado, New Mexico, and Pennsylvania), spatial and temporal leakage trends among vertical and directional wells, and the characteristics of leaked fluids. Our findings demonstrate the value of statewide well testing programs and highlight the challenges of interpreting disparate interjurisdictional well testing data.

04 OIL SHALES AND TAR SANDS↗

Formation of Composite SiC/SiC Joints by Embedded Wire Chemical Vapor Deposition

The joining of ceramic monoliths or composites to date has primarily been limited to the formation of brittle monolithic joints using heterogeneous (dissimilar) materials, similar to brazing in metals. The development of a damage-tolerant joint layer by SiC fiber reinforcements is demonstrated here. Tube workpieces made of SiC fiber-SiC matrix composite are joined using a nonwoven SiC fiber mat densified by embedded wire chemical vapor deposition (EWCVD), creating a fiber-reinforced weld-like joint by homogeneous joining. EWCVD uses a localized heating method to target deposition and growth to the joint region specifically, while minimizing thermal damage to the surrounding composite tube material. X-ray computed tomography (XCT) is used to nondestructively characterize as-made joints for relative density, adhesion, and composition. In situ XCT analysis during mechanical testing revealed crack deflections in the bonding layer, which indicates a toughening mechanism typical of ceramic matrix composite phase. Gas permeation testing of these proof-of-concept composite joints identified relatively high leak rates in comparison to fully coated SiC/SiC composite tube workpieces. In conclusion, the novelty of the composite joining method and current technology challenges, including gas permeability, are discussed in comparison with traditional ceramic joints and materials.

SiC↗

OES CO 2 Pipeline FEED Project Design Basis Memorandum

The OES CO₂ Pipeline project will move captured carbon dioxide from two ethanol facilities near Gibson City, Illinois, roughly 7.8 miles southeast to three injection wells outside Anchor, where it will be permanently stored underground. The system is designed to handle up to 4.5 million metric tonnes per year of dense-phase CO₂ at pressures up to 2,500 psig, using 16-inch mainline pipe and 10.750-inch laterals made from API 5L X-60 and X-65 steel. Wall thicknesses vary depending on location, with thinner pipe in open country, heavier wall at road crossings, and the heaviest where the pipe passes under highways or railroads via horizontal directional drill. The pipe gets a fusion-bonded epoxy coating, with an added abrasion-resistant layer wherever it's bored or drilled. Major water crossings will use HDD rather than open trenching. The pipeline will be cathodically protected, equipped with SCADA-compatible pressure and temperature instrumentation, and monitored for leaks using a computational pipeline monitoring system per API RP 1130. Hydrostatic testing will be performed at 1.25 times design pressure, and an ILI caliper run will follow to catch any construction defects. Several items, including fracture toughness requirements, specific NDE methods, and ILI tool selection, are left for the detailed design phase. The whole system falls under 49 CFR Part 195 and ASME B31.4, and Gulf Interstate Engineering prepared this document as the FEED-level design basis under the CarbonSAFE Phase III program.

09 BIOMASS FUELS↗

Reducing Methane Emissions with an Engine Fuel Reformer

Southwest Research Institute (SwRI) designed and demonstrated a compact, plasma-based fuel reformer designed to reduce methane leaks from natural-gas engines used in pipeline compression and industrial power applications. The system uses pulsed electrical discharges to convert a small portion of methane (CH4) into hydrogen (H2) and light hydrocarbons, promoting more complete combustion and reducing unburned methane in the exhaust. The reformer was evaluated through bench-scale testing, high-flow facility testing, and engine-integration testing on representative low-speed and high-speed natural-gas engines. Measured methane-leak reductions ranged from 1 to 27 percent, depending on engine type and operating condition, while reformer energy consumption remained below one percent of total engine output. Design refinements addressed thermal and electrical challenges, resulting in reliable operation with minimal impact on engine control systems. The project achieved all performance objectives within budget and schedule, produced a patentable pulsed-power system design, and established a scalable, energy-efficient pathway for mitigating methane leaks from existing natural-gas engine infrastructure.

03 NATURAL GAS↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Methane Mitigation Using Linear Motor Leak Recovery Compressor

GTI Energy (GTI), in collaboration with The University of Texas at Austin - Center for Electromechanics (UT‑CEM), designed, fabricated, and tested a linear motor–driven compressor intended to mitigate methane emissions at natural gas facilities across transmission, storage, gathering, and processing sectors of the gas value chain.

02 PETROLEUM↗

Corrosion of 316H Stainless Steel Specimens in Two FLiBe (LiF-BeF 2 ) Salt Batches

This milestone was originally envisioned for completion in FY21 and was delayed due to the COVID-19 response and difficulties in fabricating fluoride salts. To complete the milestone, commercial FLiBe was compared to a batch of FLiBe produced by the conventional hydrofluorination process. However, the batch was stopped early due to an HF leak and the salt did not undergo the final H2 sparging. Subsequent static compatibility testing of 316H specimens in 316H capsules resulted in small mass losses for the commercial FLiBe and much larger mass losses for the 2nd batch of FLiBe.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fitness For Service Assessment of a Corroded Heat Exchanger

Within the Fermi National Accelerator complex, there exist various water systems that support accelerator operations. One of these systems is extremely vital to the operation of the machine; that is the cooling system. The cooling system consists of nine relatively large heat exchangers that take untreated pond water and use it to cool the process fluid that further cools machine components. Over the 30 years these heat exchangers have been in operation, they have undergone significant material loss on the channels. This material loss, due to various forms of corrosion such as galvanic and microbiologically influenced corrosion (MIC) and possibly others, has deteriorated more than 80% of the nominal wall thickness of some of the exchangers and placed them in a questionable state. ASME FFS-1 (API 579) has been applied to address the condition of the heat exchangers due to their noncompliance with the governing code, BPVC Sec. VIII Div. 1. The assessments encompassed ASME FFS-1 parts 4: General Metal Loss and 9: Crack Like Flaw using level 1, 2, and 3 analysis techniques based on inspection data obtained by API 510 inspections. Level 1 and 2 assessments were deemed unfit for the corroded regions due to their location relative to a major structural discontinuity (channel to tube-sheet joint), so a level 3 analysis was conducted according to ASME Sec. VIII Div. 2 (design by analysis) rules for pressure vessels. Supplemental information included pond water tests to determine an accurate future corrosion allowance due to lacking inspection history. A leak before break (LBB) route was chosen to evaluate the possibility of leaking prior to the onset of failure. The analysis of one heat exchanger shows that the possibility the channel will develop a pinhole leak over 2.5 more years of operation should not be overlooked, but burst was unlikely from operation. The use of fracture mechanics show, that if a through-wall crack were to develop, it would not propagate further than the channel geometry and cause a leak not greater than 35 GPM. Using ASME Section XI Code Case N-705-1, allowing us to operate with a leak until the next outage given certain operating conditions and developing a leak mitigation procedure, this heat exchanger is deemed fit-for-service.

Humenik, Alex [Fermilab]↗

An Engineered Minimal-Set Stimulus for Periodic Information Leakage Fault Detection on a RISC-V Microprocessor

Recent evaluations of counter-based periodic testing strategies for fault detection in Microprocessor (μP) have shown that only a small set of counters is needed to provide complete coverage of severe faults. Severe faults are defined as faults that leak sensitive information, e.g., an encryption key on the output of a serial port. Alternatively, fault detection can be accomplished by executing instructions that periodically test the control and functional units of the μP. In this paper, we propose a fault detection method that utilizes an ’engineered’ executable program combined with a small set of strategically placed counters in pursuit of a hardware Periodic Built-In-Self-Test (PBIST). We analyze two distinct methods for generating such a binary; the first uses an Automatic Test Generation Pattern (ATPG)-based methodology, and the second uses a process whereby existing counter-based node-monitoring infrastructure is utilized. We show that complete fault coverage of all leakage faults is possible using relatively small binaries with low latency to fault detection and by utilizing only a few strategically placed counters in the μP.

42 ENGINEERING↗

First Annual Report on Development of Microwave Resonant Cavity Transducer for Fluid Flow Sensing: Development of Sensor Performance Model of Microwave Cavity Flow Meter for Advanced Reactor High Temperature Fluids

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. Feasibility of the sensor was initially investigated with analytical derivations and with COMSOL RF Module computer simulations of resonant frequency spectral shift due to uniform load. We also investigated the mechanical integrity of the flowmeter’s membrane through analytical modelling and COMSOL Structural Mechanics Module computer simulations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the material’s yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure. Using results from models, we have developed an initial design for a microwave K-band sensor. A cylindrical resonator prototype was fabricated from brass for the initial tests. The external dimensions of the cavity are matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed consisting of a piping Tee with a bulkhead WR-42 microwave waveguide installed in a leak-proof assembly. A microwave waveguide circulator was installed in the setup to suppress the effect of reflections at the cavity entrance by increasing the isolation between the input and the output port. Preliminary spectral characterization of cavity spectral response was performed with a portable PXIe chassis microwave VNA with a custom GUI. Preliminary dry tests of the transducer response were conducted with a set of calibrated weights. Transducer frequency shift was shown to be monotonically increasing with increasing pressure. The next steps will involve investigation of the transducer performance for water flow sensing.

42 ENGINEERING↗

Distributed Optical Fiber Sensor Systems: Application to Natural Gas Pipeline Monitoring

Distributed fiber optic sensing is a cutting-edge technology that has found extensive applications in the monitoring of pipelines. Considering the low backscattering level of standard single-mode fiber as fiber under test, a Rayleigh enhanced optical fiber embedded within the tight-buffered cable is demonstrated in field testing. We analyzed the increased backscattering fiber cable's vibration performance to the conventional single-mode telecom fiber using a custom-built Φ-OTDR interrogator system. Thereafter, using a 4-inch steel pipeline with a flow rate of 5, 10, 15, and 20 ft/s and a fixed pressure level of 1000 psi, we field-tested the sensor system for monitoring natural gas pipeline acoustic vibrations. We also field tested Brillouin optical time domain analysis (BOTDA) system for pipeline hoop strain monitoring under various pressure conditions. The pilot-scale testing results presented in this study suggested that pipeline operators can accurately perform flow monitoring, leak detection, and pressure monitoring for pipeline integrity monitoring.

Lalam, Nageswara↗

BioID/LID System Cartridge Testing Report

LLNL produced two lots of lyophilized LAMP assay containing cartridges, LNL022818 and LNL071818, for testing on Gen3 BioID systems. Thirty-nine cartridges were tested for lot LNL022818. All thirty-nine cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Five different templates were tested on these 39 cartridges. The BioID system detected 79.1% true positives and 9.3% false positives along with 98.9% true negatives and 2.9% false negatives for cartridge lot LNL022818. Thirty cartridges were tested for lot LNL071818. It was noted early that due to a manufacturing issue with the cartridges related to incomplete sonic welding of the cartridge, a large fraction of lot LNL071818 cartridges leaked. Insufficient funds were available to replace this lot of cartridges. Twenty three of 30 cartridges performed as expected regarding correct positive control (IPC) and negative control (NTC) reactions. Four different templates were tested on these 30 cartridges. The BioID system detected 77% true positives and 23% false positives along with 96.9% true negatives and 3.1% false negatives for cartridge lot LNL071818. For all tested cartridges using DNA template, DNA was added at a final concentration of 25 pg/ul. All reactions contained positive control DNA at 2.5 pg/ul.

42 ENGINEERING↗