At least 91 records · Page 5

5ω Optical Thomson Scattering Report

The 5ω Optical Thomson Scattering system on the National Ignition Facility (NIF) is a diagnostic designed to measure temporally and spatially resolved plasma conditions in Inertial Confinement Fusion (ICF) Hohlraums. The system was proposed in 2014 and a phased approach to implementation was developed. In phase one the collection system was designed, built, and fielded on the NIF to be used for 3ω Thomson scattering measurements and background measurements near 211 nm (5ω. The initial commissioning experiment for the collection system was completed in Oct. 2016. Commissioning of the collection system continued through 2017 and the system is now fielded for a range of user experiments and regularly produces publication quality data. A dedicated 5ω probe laser was designed and built to allow Thomson scattering measurements in the presence of 2 MJ of 3ω drive energy. Due to scattered light (spectral reflections, laser-plasma instabilities, and unconverted drive energy) from the 3w drive lasers typical wavelengths (2ω and 4ω) fielded at other laser facilities like the Nova Laser Facility and the Omega Laser Facility were unable to meeting the signal to background requirements in design studies. A 10 Joule 5ω probe was proposed as a solution that met requirements. This 10 Joule laser was more energetic than previously fielded 5w lasers by 2-3 orders of magnitude. As part of a risk reduction plan, phase two of the project was to develop a 1 Joule, 5ω laser to demonstrate conversion efficiency >20% from 1ω to 5ω and make initial Thomson scattering measurements in the first few nanoseconds of an ICF laser pulse. Initial tests of the 5w conversion were completed at the Laboratory for Laser Energetics (LLE) and produced record 5ω energies. Based on these results from LLE, a 1 Joule, 5w laser system was designed for the NIF in 2018 and commissioning began in 2019. Commissioning of the 5ω laser system continued through 2023 and was eventually paused in Q1 of FY24 due to completing resource constraints. Commissioning of the 5w laser system proved incredibly challenging. Multiple issues were identified during commissioning and resolved, but issues remain. Currently there is not a clear understanding of why 5ω scattered has not been detected on the OTS collection system. Based on offline measurements, calculations, and preshot measurements the system appears to meet all requirements. Potential target physics issues have been investigated and do not appear to be an issue. The current hypothesis is that there is an error in one or more aspects of the offline testing not translating to expected performance when the system is fielded on the NIF. Additional full system testing in-situ utilizing the complete OTS system and NIF target chamber center time is needed to further test potential failure modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a robust damage analysis scheme at the National Ignition Facility

The onset of laser-induced damage in optical materials is a limiting factor in the design and operation of most high-energy laser systems. As such, significant effort has been dedicated to developing laser damage testing protocols and procedures to inform laser system design and operating limits. These tests typically rely on multiple laser exposures for statistical validation. Historically, small beam single fluence (N / 1) or ramped fluence (R / 1) tests have been used to quantify the “laser-induced damage threshold” of a material. However, due to various distributions in damage precursor populations, the laser fluence at which damage occurs for a given sample varies with beam size and is therefore better described as the onset of observed damage for that testing geometry. In conclusion, we document the development of irradiation, measurement, and analysis methods for damage testing resulting in damage initiation density as a function of incident fluence or ρ(ϕ) which is suitable for both small and large beam area testing and more conducive to extrapolating from one to the other.

Beam diameter↗

Impact of high-temperature annealing on hafnia-silica composite coatings deposited via ion beam sputtering for high-peak power 1064 nm lasers

The maximum power handling fluence of high-peak and average power laser systems is often limited by the laser damage of the coatings on optical components. Furthermore, these multilayer dielectric coatings are limited in their maximum power handling due to laser-damage-prone defects in the lower optical bandgap, higher optical index material. Some of these defects can be mitigated by thermal annealing to high temperatures, which can greatly reduce the linear absorbative precursors. Typically, hafnia and silica are the materials of choice for high-peak and average power laser systems in the ultraviolet through infrared spectral range; however, hafnia crystalizes readily when annealed at high temperatures. In this study, we prepare composite HfO 2 -SiO 2 coatings by co-sputtering hafnia and silica in an ion beam sputtering system and compare them to pure hafnia-based coatings. We demonstrate that crystallinity in hafnia can be completely suppressed when it is mixed with silica, such as the composite coatings in this study. High reflectors were fabricated and annealed, demonstrating that the multilayer dielectric stacks can survive high-temperature annealing and exhibit an excellent linear absorption of 0.2 +/- 1 ppm at 1064 nm. Short- and long-pulse laser damage was explored, demonstrating the complex relationship between linear absorption and the non-linear absorption which drives pulsed laser damage. These results provide an excellent route to the creation of very low linear absorption optical coatings, which also utilize low scattering materials that are best suited for high-peak and average power applications.

Harthcock, Colin [Lawrence Livermore National Labo↗

Applications of LIF to Document Natural Variability of Chlorophyll Content and Cu Uptake in Moss

Chlorophyll has long been used as a natural indicator of plant health and photosynthetic efficiency. Laser-induced fluorescence (LIF) is an emerging technique for understanding broad spectrum organic processes and has more recently been used to monitor chlorophyll response in plants. Previous work has focused on developing a LIF technique for imaging moss mats to identify metal contamination with the current focus shifting toward application to moss fronds and aiding sample collection for chemical analysis. Two laser systems (CoCoBi a Nd:YGa pulsed laser system and Chl-SL with two blue continuous semiconductor diodes) were used to collect images of moss fronds exposed to increasing levels of Cu (1, 10, and 100 nmol/cm 2 ) using a CMOS camera. The best methods for the preprocessing of images were conducted before the analysis of fluorescence signatures were compared to a control. The Chl-SL system performed better than the CoCoBi, with dynamic time warping (DTW) proving the most effective for image analysis. Manual thresholding to remove lower decimal code values improved the data distributions and proved whether using one or two fronds in an image was more advantageous. A higher DTW difference from the control correlated to lower chlorophyll a/b ratios and a higher metal content, indicating that LIF, with the aid of image processing, can be an effective technique for identifying Cu contamination shortly after an event.

59 BASIC BIOLOGICAL SCIENCES↗

Designing Track for Electrospinning Unit and Cost-Effective Laser Scanning System

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Designing a track for an electrospinning unit and cost-effective laser scanning system

Nanofibers are produced in the Targeted Systems Department (TSD) by applying a large voltage to the nanofiber fluid and the collection apparatus known as the electrospinner. The fiber is then shot out of nozzles and collected onto the electrospinner into a nanofiber mat. The problem is that since the nozzle heads are stationary, there is non-uniform deposition of nanofiber on the collection drum leading to variation in thickness of the produced nanofiber mat. To mitigate this issue, a reciprocating mechanism is designed to move the nozzle along the drum collector along with the ability to vary its stroke length. This design was realized using Siemens NX and several parts were printed using a 3D printer, but is, as of writing, untested. Second project involved providing an alternative method to scan a large sample that had undergone certain surface deformation by beam interaction and detect out of plane deformation such as micro-scale swelling and surface roughness. Systems to carry out this scanning already exist; however, they are expensive and produce many files that need to be stitched together and are cumbersome to deal with. The solution is to create a scanning system using an already purchased scanning laser and linear stage motor. The laser and stage motor were combined to produce length results that aligned with a digital microscope but differing height results.

Ruffolo, Leopoldo↗

Performance characterization of freeform finished surfaces of potassium dihydrogen phosphate using fluid jet polishing with a nonaqueous slurry

Abstract Potassium dihydrogen phosphate (KDP) and its deuterated analog (DKDP) are unique nonlinear optical materials for high power laser systems. They are used widely for frequency conversion and polarization control by virtue of the ability to grow optical-quality crystals at apertures suitable for fusion-class laser systems. Existing methods for freeform figuring of KDP/DKDP optics do not produce surfaces with sufficient laser-induced–damage thresholds (LIDT’s) for operation in the ultraviolet portion of high-peak-power laser systems. In this work, we investigate fluid jet polishing (FJP) using a nonaqueous slurry as a sub-aperture finishing method for producing freeform KDP surfaces. This method was used to selectively polish surface areas to different depths on the same substrate with removals ranging from 0.16 μm to 5.13 μm. The finished surfaces demonstrated a slight increase in roughness as the removal depth increased along with a small number of fracture pits. Laser damage testing with 351 nm, 1 ns pulses demonstrated excellent surface damage thresholds, with the highest values in areas devoid of fracture pits. This work demonstrates, for the first time, a method that enables fabrication of a waveplate that provides tailored polarization randomization that can be scaled to meter-sized optics. Furthermore, this method is based on FJP technology that incorporates a nonaqueous slurry specially designed for use with KDP. This novel nonaqueous FJP process can be also used for figuring other types of materials that exhibit similar challenging inherent properties such as softness, brittleness, water-solubility, and temperature sensitivity.

36 MATERIALS SCIENCE↗

Particle Beam Acceleration Using 3 Petawatt Laser Pulses

The Zettawatt-Equivalent Ultrashort pulse laser System (ZEUS) is presently operational at the Gerard Mourou Center for Ultrafast Optical Science (CUOS) at the University of Michigan. ZEUS is a significant upgrade of the previous high power laser systems at CUOS and consists of two beamlines thatoperate in perfect synchronization. The 500 TW beamline became operational in 2023, 2 PW operation started in 2025 and full 3 PW power levels will be available in 2026. It is presently the highest power laser system in the US. In this grant the high field science group at CUOS has leveraged this unique high power laser facility to investigate laser wake field acceleration (LWFA) in ultra-high power laser plasma interactions and have shown how this can scale for future electron–positron colliders at high energy. The dual beam experimental configuration enables flexibility for many frontier experiments in laser-driven acceleration research, in particular, enabling extended channelling/acceleration experiments, positron generation/acceleration experiments and proof-of-principle transverse pumping “dephasingless” electron acceleration experiment and theory. LWFA may be able to miniaturize particle accelerators for high energy physics and also enable new sources of ultrafast, extreme brightness and precise x-rays for a wide variety of applications. In laser wake field acceleration, an electron bunch “surfs” on the electron plasma wave (the “wake field”) generated by the ponderomotive force of an intense laser. The plasma wave has a strong longitudinal electric field that stays in phase with the relativistic driver. A relativistic charged particle may, therefore, remain in phase with the accelerating field over long distances and gain ultra-relativistic energies. The accelerating electric field strength that the plasma wave can support can be many orders of magnitude higher than that of conventional accelerators, which makes laser wakefield acceleration an exciting prospect as an advanced accelerator concept. In this research project we have investigated the scaling of this mechanism to laser powers of 2 PW and have measured the x-ray emission and radio frequency emission resulting from the acceleration process. We have also performed theoretical investigation of mechanisms to scale laser driven accelerators to much higher energy using dephasingless acceleration processes.

43 PARTICLE ACCELERATORS↗

Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (~1182 to 1000 cm –1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. Furthermore, the mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Laser calibration system and lost muons correction in the g-2 experiment

The Muon g-2 experiment at Fermilab has the main goal to measure the muon anomalous magnetic moment $a_{µ}$ = ($g$ − 2)/2 to a precision of 0.14 parts per million (ppm), which means 4 times improvement in precision with respect to the final result from BNL: $a_{µ}$ (expt. BNL) = 11659208.0(6.3) × 10$^{−10}$ (0.54 ppm) In this report I summarize the work done at the $g$-2 experiment during my summer internship at Fermilab. In the first two weeks my first task has been to replace the NIM logic used in the Laser Calibration System with a new FPGA. Then, I was involved in the Lost Muons analysis studying both real data and MonteCarlo simulations.

43 PARTICLE ACCELERATORS↗

Towards Portable Laser Desorption Postionization Mass Spectrometry Utilizing Microchip Laser Pulses

A 355 nm, 1.5 ns, up to 1 kHz microchip laser system has been tested to both yield ablation spots and postionize material within a plasma plume. A 30 µJ pulse energy microchip laser successfully ablated all samples: 6601 aluminum, 316 and 304 stainless steel, and Mo metal. While visible ablation craters were observed on all samples mentioned above, the stainless-steel samples displayed visible color changes in the resolidified iron, indicating ionization with the 355 nm pulses during ablation. Additionally, when used to intercept a plasma plume of Cs 2 CO 3 made with a separate laser system, the microchip laser pulses yielded Cs + emission signal otherwise not observed. With these experiments completed, the microchip laser has been successfully verified for readiness to be integrated into the front end of a mass spectrometer system as the ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Versatile system for ion energy measurements generated by pulsed laser ionization: Insights into electron-ion dynamics

Ion energy distributions generated by pulsed laser interactions with materials are essential for applications ranging from materials science to oncology. Ion energy characterization is particularly important for an emerging mass spectrometry technique called virtual-slit cycloidal mass spectrometry (VS-CMS). The ion energy distribution influences the design and performance of VS-CMS instruments, as well as the efficacy of laser-driven ionization methods in various fields. Several established techniques, including the retarding potential method, time-of-flight (TOF) analysis, and electrostatic energy analyzers, have been employed to measure ion energy distributions. The wide range of ion energies reported highlights the strong dependence of ion energy on laser parameters, target materials, and experimental conditions, as well as the necessity of making independent measurements of the ion energy distribution for specific laser systems and materials. This paper presents the design and characterization of a simple TOF-based apparatus for measuring ion energy distributions from pulsed laser ionization without external fields. This approach minimizes perturbation of electron-ion dynamics and enables simultaneous energy measurements at multiple spatial positions. Here, the apparatus was tested using a nanosecond pulsed Nd:YAG laser operating at 1064 nm, 532 nm, and 266 nm on solid copper sheets at various laser fluences. Simultaneous measurements at different distances provide new insights into ion-electron interactions post-ionization and demonstrate the influence of laser wavelength and fluence on ion energy distributions.

Ion energy↗

Optical characterization of the on-target OMEGA focal spot at high energy using the full-beam in-tank diagnostic

The full-beam in-tank (FBIT) diagnostic has been deployed to directly measure the target-plane beam fluence profile, when operated at high energy, of the OMEGA Laser System at the University of Rochester’s Laboratory for Laser Energetics. This article presents the results of early measurements taken with this diagnostic and discusses an improvement that has overcome performance limitations discovered during the initial testing. The diagnostic gives new insight into the ability of the OMEGA Laser System to provide uniform fluence profiles that are consistent across all 60 beams in the laser. Overall, the ultimate goal of the FBIT diagnostic is to allow accurate assessment of the fluence uniformity on a spherical target in 60-beam implosion experiments

47 OTHER INSTRUMENTATION↗

Advances in laser-based bremsstrahlung x-ray sources. I. Optimizing laser-accelerated electrons

In this work, we have performed a suite of kinetic simulations of relativistic laser–plasma interaction under settings relevant to recent and planned experiments on a variety of laser systems. The goal of the study is to illuminate the physics of laser–target coupling and to provide guidance for how to optimize these sources for applications. It is shown that the production of relativistic electrons is maximized when conditions of relativistic induced transparency (RIT) in dense plasmas can be achieved over a large interaction volume at the time of arrival of most intense part of the laser pulse. RIT is shown to enhance both the numbers of relativistic electrons and the energies of the electrons, leading to an increased x-ray dose. A variety of approaches to enhancing laser–target coupling are considered. These include optimizing the effects of low-density pre-plasma (arising either from finite laser pedestal or from the use of foam coatings) and of modifying the laser focusing geometry to reduce effects of filamentation and self-focusing. Evidence of a novel approach to achieving stable laser propagation over distances of tens of micrometers in a plasma gradient is also presented. These conditions coincide with plasma and laser conditions explored in recent experiments on the Omega EP laser system and compare favorably with an analytic criterion for stable laser propagation in relativistically underdense plasma obtained from a nonlinear Wentzel–Kramers–Brillouin analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A future of inertial confinement fusion without laser-plasma instabilities

From the beginning of inertial confinement fusion (ICF) research, laser-plasma instabilities excited by narrowband lasers have limited the hydrodynamic design space of all laser-based approaches to inertial fusion energy (IFE). With advances in broadband laser technologies, the next generation of ICF drivers will likely have large bandwidth that is engineered to mitigate laser-plasma instabilities, thereby expanding the hydrodynamic design space to include both robust high yields (>200−MJ) with large-energy laser systems (>4 MJ) and high gains (>10) with moderate-energy laser facilities (<2 MJ). State-of-the-art simulations indicate that laser bandwidths of a few percent are required to mitigate instabilities for IFE-relevant conditions. To test these models and demonstrate that high-bandwidth lasers mitigate laser-plasma instabilities, the Fourth-generation Laser for Ultrabroadband eXperiments will be used with the OMEGA Laser System. The goal is to provide the community with the confidence to invest in a multiple-beam high-bandwidth laser facility that will demonstrate the necessary ablation pressures for robust direct-drive ignition without detrimental levels of hot electrons that degrade the implosion performance. It is important to recognize that the highest performing ICF implosions will likely never be completely LPI free because of the significant advantages to maximizing the laser intensity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Refractive Index Adhesives for Laser Glass Cladding Applications (ABBREVIATED Report)

To eliminate parasitic light oscillations (amplified spontaneous emission (ASE)), high energy laser systems often utilize polymeric materials to adhere optically absorptive cladding materials to laser gain media (glass or crystal). Most of these polymeric optical adhesives are index matched to lower index gain media, and there was no capability to achieve refractive indices (RI) greater than 1.60 with low color, while also maintaining mechanical compliance to serve as adhesives for cladding applications. The completion of LDRD 23-FS-043 shows we can chemically develop novel suitable adhesive candidates with refractive indices above 1.64 at 532 nm while also exhibiting Shore A hardness between 50-90, with high optical clarity, low color, and minimal haze for films ~1-2 mm thick (84 %Transmission at 532 nm). This will enable us to begin mapping a process space to allow future customizable adhesive formulations for building a variety of laser systems with tunable refractive index matching for various gain and cladding media.

36 MATERIALS SCIENCE↗

High repetition-rate pulse shaping of a spectrally broadened Yb femtosecond laser

We demonstrate compression and shaping of few cycle pulses from a high average power ytterbium laser system. The pulses from a commercial 20 W, 100 kHz Yb laser system are spectrally broadened in two-stages using cascaded, gas-filled, stretched hollow-core fibers and then compressed and shaped in an acousto-optic modulator-based pulse-shaper. The pulse-shaper allows for compression, characterization, and shaping all in one system, producing ∼10 fs pulses with 30 μ J of energy.

Codere, Julia↗

Dynamic motion trajectory control with nanoradian accuracy for multi-element X-ray optical systems via laser interferometry

The past decades have witnessed the development of new X-ray beam sources with brightness growing at a rate surpassing Moore’s law. Current and upcoming diffraction limited and fully coherent X-ray beam sources, including multi-bend achromat based synchrotron sources and high repetition rate X-ray free electron lasers, puts increasingly stringent requirements on stability and accuracy of X-ray optics systems. Parasitic motion errors at sub-micro radian scale in beam transport and beam conditioning optics can lead to significant loss of coherence and brightness delivered from source to experiment. To address this challenge, we incorporated optical metrology based on interferometric length and angle sensing and real-time correction as part of the X-ray optics motion control system. A prototype X-ray optics system was constructed following the optical layout of a tunable X-ray cavity. On-line interferometric metrology enabled dynamical feedback to a motion control system to track and compensate for motion errors. The system achieved sub-microradian scale performance, as multiple optical elements are synchronously and continuously adjusted. This first proof of principle measurement demonstrated both the potential and necessity of incorporating optical metrology as part of the motion control architecture for large scale X-ray optical systems such as monochromators, delay lines, and in particular, X-ray cavity systems to enable the next generation cavity-based X-ray free electron lasers.

47 OTHER INSTRUMENTATION↗