Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laser interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measuring Liquid Drops In Gas Flow

Nonintrusive optical technique enables measurement of drops of water ingested through aircraft-engine nacelle. Drops photographed by light of laser beam directed across nacelle inlet. Beam shaped by beam expander and slit into sheet 9 mm thick. Exposure time only 10 ns- length of laser pulse, and drop motion therefore frozen in each of series of photographs. Fluorescent dye added to water improves edge definition of photographic images of drops; scattered laser light and its interference effects filtered out and only light at fluorescence wavelength photographed. Technique used in research on ingestion of water from heavy rain or wheel spray, but adapts to any droplet-laden gas stream.

Parikh, Pradip G.↗

Optically-Tuned Far-Infrared Device

Spacing of visible interference pattern determines frequency of infrared radiation. Variable photoconductivity grating formed by interference of two visible laser beams intersecting on surface of proposed AlGaAs device substituted for fixed metal grating. Proposed device provides higher output-power density and greater tunability.

Katz, Joseph↗

Investigation of the 176 Yb Interference Correction during Determination of the 176 Hf/ 177 Hf Ratio by Laser Ablation and Solution Analysis on the Neoma MC-ICP-MS

We utilized the Neoma™, a recently released MC-ICP-MS platform offered by ThermoFisher Scientific, to assess the behavior of the Lu-Yb-Hf system during laser ablation analyses of various zircon standards as well as solution-based analyses of the JMC-475 Hf standard doped with varying quantities of Yb and Lu. The primary goal of this work was to characterize the behavior of the Yb interference correction on the Neoma™ platform since this is one of the biggest issues in the Hf isotope analysis community and because the Neoma™ platform will supplant the Neptune™ series instrument. During laser ablation analysis, we found that the overall data quality scales proportionally with the total Hf signal intensity, with higher signal analyses producing extremely accurate (within 1 ε Hf unit) and precise (sub ε Hf unit within-run standard errors) data. At low Yb signals (<0.1 V 173 Yb), we were not able to produce an accurate internal Yb mass bias factor. However, utilizing an empirical approach allows for the application of session-specific relationships between the Yb and Hf mass bias factors, determined by analysis of standards of varying Yb content, to produce accurate ε Hf values from zircons with higher Yb/Hf ratios even where the total Hf signal intensity is relatively low. Similar behavior was observed in the solution analyses. Lastly, while the behavior of the Yb interference correction on the Neoma™ platform appears comparable to the Neptune™ series MC-ICP-MS, further work will help refine the understanding of the controls on mass bias behavior, oxide formation, session-to-session stability, etc.

36 MATERIALS SCIENCE↗

Artificial laser intensity oscillations associated with beam splitters.

Investigation of the interference-fringe jitter, due to wavelength instability in a laser, that gives rise to pulse-shape blurring intensity variations. The obtained results suggest that the problem can be controlled by using a perfectly flat splitter, or more easily by using a large-angle wedged splitter that either casts many fringes upon the detector element or casts none if the detector is sufficiently far from the splitter.

Kuehn, D. M.↗

Laser scattering induced holograms in lithium niobate

A 3.0-mm thick poled single crystal of lithium niobate doped with 0.1 mole% iron was exposed to a single beam and then to two intersecting beams of an argon ion laser operating at 515-nm wavelength. Laser scattering induced holograms were thus written and analyzed. The presence of diffraction cones was observed and is shown to result from the internally recorded interference pattern resulting from the interference of the original incident laser beam with light scattered from material inhomogeneities. This phenomenon is analyzed using Ewald sphere construction techniques which reveal the geometrical relationships existing for the diffraction cones.

Magnusson, R.↗

Interference microscopy study of the preplasma formed on an iron target surface exposed to high-power femtosecond laser pulses

The characteristic scale of spread of the plasma formed on the surface of a bulk iron target irradiated by a femtosecond laser pulse with an intensity of 10{sup 16} W cm{sup −2} is measured by time-resolved interference microscopy using femtosecond pulses emitted by a Cr : forsterite laser system with an intensity contrast of 10{sup 7}. The chosen technique is demonstrated to be efficient in such measurements. It is shown experimentally that, as a result of laser pulse impact, the displacement of a plasma layer with a density exceeding critical does not exceed 30 nm. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electronic Coherence and Coherent Dephasing in the Optical Control of Electrons in Graphene

Electronic coherence is of utmost importance for the access and control of quantum-mechanical solid-state properties. Using a purely electronic observable, the photocurrent, we measure a lower bound of the electronic coherence time of 22 ± 4 fs in graphene. The photocurrent is ideally suited to measure electronic coherence, as it is a direct result of coherent quantum-path interference, controlled by the delay between two ultrashort two-color laser pulses. The maximum delay for which interference between the population amplitude injected by the first pulse interferes with that generated by the second pulse determines the electronic coherence time. In particular, numerical simulations reveal that the experimental data yields a lower bound on the electronic coherence time, masked by coherent dephasing due to the broadband absorption in graphene. Overall, we expect that our results will significantly advance the understanding of coherent quantum control in solid-state systems ranging from excitation with weak fields to strongly driven systems.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Integrated particles sensor formed on single substrate using fringes formed by diffractive elements

Integrated sensors are described using lasers on substrates. In one embodiment, a first sensor forms a laser beam and uses a quartz substrate to sense particle motion by interference of the particles with a diffraction beam caused by a laser beam. A second sensor uses gradings to produce an interference. In another embodiment, an integrated sensor includes a laser element, producing a diverging beam, and a single substrate which includes a first diffractive optical element placed to receive the diverging beam and produce a fringe based thereon, a scattering element which scatters said fringe beam based on particles being detected, and a second diffractive element receiving scattered light.

Gharib, Morteza↗

Pulsed Lidar for Measurement of C02 Concentrations for the ASCENDS Mission - Update

We have been developing a laser-based sounding technique for the remote measurement of the tropospheric CO2 concentrations from orbit for NASA is ASCENDS mission. The mission's goals are to provide measurements of tropospheric CO2 abundance with global-coverage, a few hundred km spatial and monthly temporal resolution. These are needed to better understand CO2 fluxes and the processes that regulate CO2 storage by the land and oceans. For the lIP, we are developing and demonstrating the lidar techniques and key lidar technology that will permit measurements of the CO2 column abundance in the lower troposphere from aircraft. Our final goal is to demonstrate the key capabilities needed for a space lidar and mission approach for the ASCENDS mission. We use a pulsed lidar technique, which is much less sensitive to errors from cloud and atmospheric scattering and to noise from solar background. It allows continuous measurements of CO2 mixing ratio in the lower troposphere during day and night. Our approach uses the 1570nm CO2 band and a two-wavelength laser absorption spectrometer, which continuously measures at nadir from a circular polar orbit. It directs the narrow co-aligned laser beams from the instrument's lasers toward nadir, and measures the energy of the laser echoes reflected from land and water surfaces. It uses a pair of tunable laser transmitters, which allowing measurement of the extinction from a single selected CO2 absorption line in the 1570 nm band and from a line pair in the Oxygen A-band near 765 nm. These regions have temperature insensitive absorption lines are free from interference from other gases. The lasers pulse at 10KHz, use tunable diode seed lasers followed by laser amplifiers, and have MHz spectral widths. During the measurement the lasers are stepped across the selected lines at a kHz rate. The receiver uses a 1-m class telescope and photon sensitive detectors and measures the background light and energies of the laser echoes from the surface. The extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and off line echo pulse energies via the integrated path differential absorption (IPDA) technique. Our technique exploits the atmospheric pressure broadening of the lines to weight the measurement sensitivity to the atmospheric column below 5 km. Pulsed laser signals, time gated receiver are used to isolate the surface laser echo signals and to exclude photons scattered from clouds and aerosols. We have successfully demonstrated many key aspects of the approach and lidar technology in the laboratory. We have demonstrated CO2 column measurements in airborne flights during the summers of 2009 and 2010. These included measurements from 3-l3 km altitudes made over a variety of surfaces and through thin and broken clouds. We demonstrated initial airborne measurements of O2 column density to 10 km altitudes during the summer 2010 flights. More details approach, key technologies, and demonstration measurements will be given in the presentation.

Abshire, James↗

Dual-Line Detection Rayleigh Scattering Measurements of Density and Temperature

Measurements of the laser Rayleigh scattering signal in a flow to determine density and temperature have been commonly employed in open flames and in wind tunnel environments. In these measurements, the density or reciprocal temperature is correlated with the Rayleigh scattering signal intensity. A major advantage of Rayleigh scattering for these applications is the simple experimental arrangement allowed by this technique. Intensity-based Rayleigh scattering measurements of density and temperature have been limited to relatively clean flows in open environments so that interference from particle scattering and laser scattering is minimal. A new approach, using dual-line detection Rayleigh (DLDR) scattering extends the applicability of Rayleigh scattering measurements of density and temperature to enclosed environments where surface scattering interference is high. Depending on particle size and optical properties, this approach may also reduce interference from particle scattering.

Annen, Kurt↗

Collisional effects in laser detection of tropospheric OH

The use of laser-induced fluorescence to measure OH in the troposphere is discussed. It is noted that quantitative laser detection of OH requires knowledge of collisional processes affecting the measurements and interference effects due to OH generated by laser photolytic processes. Collisions induce quenching of the excited A-state, as well as vibrational and rotational energy transfer in the excited and ground states. It is noted that the state-specific nature of these processes is important, especially the rotational level dependence of quenching and vibrational transfer in excited OH. Also important is the temperature dependence according to which quenching cross sections sharply increase with decreasing temperature. Laboratory experiments studying these collisional processes are described, and their implications for laser detection of tropospheric OH are examined.

Crosley, David R.↗

The Interference of the Dynamically Squeezed Vibrational Wave Packets

An electronic excitation of a molecule by a sequence of two femtosecond phase-locked laser pulses is considered. In this case the interference between the vibrational wave packets induced by each of the subpulses within a single molecule takes place. It is shown that due to the dynamical squeezing effect of a molecular vibrational state the interference of the vibrational wave packets allows one to measure the duration of a femtosecond laser pulse. This can be achieved experimentally by measuring the dependence of the integral fluorescence of the excited molecule on the delay time between the subpulses. The interference can lead to a sharp peak (or to a down-fall) in that dependence, the width of which is equal to the duration of the laser pulse. It is shown that finite temperature of the medium is favorable for such an experiment.

Vinogradov, An. V.↗

On-chip polarimetry for high-throughput screening of nanoliter and smaller sample volumes

A polarimetry technique for measuring optical activity that is particularly suited for high throughput screening employs a chip or substrate (22) having one or more microfluidic channels (26) formed therein. A polarized laser beam (14) is directed onto optically active samples that are disposed in the channels. The incident laser beam interacts with the optically active molecules in the sample, which slightly alter the polarization of the laser beam as it passes multiple times through the sample. Interference fringe patterns (28) are generated by the interaction of the laser beam with the sample and the channel walls. A photodetector (34) is positioned to receive the interference fringe patterns and generate an output signal that is input to a computer or other analyzer (38) for analyzing the signal and determining the rotation of plane polarized light by optically active material in the channel from polarization rotation calculations.

Bornhop, Darryl J.↗

Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator

We describe a direct magneto-optical approach to measuring the magnetic field driven by a narrow pulse width (<10 ns), 20 kA electrical current flow in the transmission line of a high energy pulsed power accelerator. The magnetic field and electrical current are among the most important operating parameters in a pulsed power accelerator and are critical to understanding the properties of the radiation output. However, accurately measuring these fields and electrical currents using conventional pulsed power diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element sensing crystal sensor that is highly resistant to electromagnetic interference and does not require external calibration. Here, we focus on device theory, operating parameters, results from an experiment on a high energy pulsed power accelerator, and comparison to a conventional electrical current shunt sensor.

42 ENGINEERING↗

Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid

We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.

Owens, Israel [Sandia National Laboratories (SNL-N↗

Receiver Signal to Noise Ratios for IPDA Lidars Using Sine-wave and Pulsed Laser Modulation and Direct Detections

Integrated path differential absorption (IPDA) lidar can be used to remotely measure the column density of gases in the path to a scattering target [1]. The total column gas molecular density can be derived from the ratio of the laser echo signal power with the laser wavelength on the gas absorption line (on-line) to that off the line (off-line). 80th coherent detection and direct detection IPDA lidar have been used successfully in the past in horizontal path and airborne remote sensing measurements. However, for space based measurements, the signal propagation losses are often orders of magnitude higher and it is important to use the most efficient laser modulation and detection technique to minimize the average laser power and the electrical power from the spacecraft. This paper gives an analysis the receiver signal to noise ratio (SNR) of several laser modulation and detection techniques versus the average received laser power under similar operation environments. Coherent detection [2] can give the best receiver performance when the local oscillator laser is relatively strong and the heterodyne mixing losses are negligible. Coherent detection has a high signal gain and a very narrow bandwidth for the background light and detector dark noise. However, coherent detection must maintain a high degree of coherence between the local oscillator laser and the received signal in both temporal and spatial modes. This often results in a high system complexity and low overall measurement efficiency. For measurements through atmosphere the coherence diameter of the received signal also limits the useful size of the receiver telescope. Direct detection IPDA lidars are simpler to build and have fewer constraints on the transmitter and receiver components. They can use much larger size 'photon-bucket' type telescopes to reduce the demands on the laser transmitter. Here we consider the two most widely used direct detection IPDA lidar techniques. The first technique uses two CW seeder lasers, one on-line and one offline that are intensity modulated by two different frequency sine-waves signals before being amplified by a common laser amplifier. The receiver uses narrowband amplitude demodulation, or lock-in, Signal processing at the given laser modulation frequencies [3,4]. The laser transmitter operates in a quasi CW mode with the peak power equal to twice the average power. The on-line and off-line lasers can be transmitted at the same time without interference. Another direct detection technique uses a low duty cycle pulsed laser modulation [5,6] with the laser wavelengths alternating between on-line and off-line on successive pulses. The receiver uses time resolved detection and can also provide simultaneous target range measurement. With a lower laser duty cycle it requires a much higher peak laser power for the same average power.

Sun, Xiaoli↗

Simple, passive design for large optical trap arrays for single atoms

We present an approach for trapping cold atoms in a two-dimensional (2D) optical trap array generated with a 4f filtering scheme and custom transmission mask without any active device. The approach can be used to generate arrays of bright or dark traps, or both simultaneously with a single wavelength for forming two-species traps. We demonstrate the design by creating a 2D array of 1225 dark trap sites, where single Cs atoms are loaded into regions of near-zero intensity in an approximately Gaussian profile trap. Moreover, we demonstrate a simple solution to the problem of out-of-focus trapped atoms, which occurs due to the Talbot effect in periodic optical lattices. Using a high power yet low cost spectrally and spatially broadband laser, out-of-focus interference is mitigated, leading to near perfect removal of Talbot plane traps.

74 ATOMIC AND MOLECULAR PHYSICS↗