Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “laboratory evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Bit error rate measurement for evaluation of a fiber optic link

Digital fiber-optic data-link terminal modules are being developed in a number of laboratories, and often the modules take the form of black boxes without convenient access to internal signals. This paper discusses types of measurements which can be made using only the digital terminals of the link. Bit-error-rate (BER) vs signal-power data can, of course, provide a means for proving overall link performance, but it can also be used to determine certain internal parameters of the receiver. The theoretical dependence of the BER-vs-light-signal-power curve shape on receiver input-noise equivalent power and comparator slicing level is discussed. BER-vs-light-signal-power measurements obtained with an experimental link are presented and interpreted with the aid of the theoretical curves. The effects of other problems, such as hum or oscillation, on the BER data are mentioned. Sensitivity of the system BER to bit rate is also discussed, with application to determining system operating limits. Since BER measurements are simple to make and can easily be automated, they may prove to be a useful means for either laboratory evaluation or production-line acceptance testing of sealed terminal modules.

Bergman, L. A.↗

Measurements of microlens performance

We present results of laboratory evaluations of several microlens types that have been designed and fabricated at the Lockheed Research and Development Division. The microlenses include wideband and dispersive types, in isolation and in arrays, and fabricated with binary or grayscale methods. Different lens pixel geometries are considered, including square, hexagonal, and skewed microlenses. We describe our micro-optics laboratory testbed which has been designed for the evaluation of individual lenslets or 2D arrays at selected spectral wavelengths. Measurement capabilities include focal length, point-spread functions, wavefront quality, and modulation transfer functions. Our present effort focuses on the results of point spread function measurements and their comparison with design predictions.

Shough, D.↗

PV Module Operating Temperature - Data and Resources

The Photovoltaic Systems Evaluation Laboratory (PSEL) at Sandia National Laboratories (SNL) in Albuquerque, NM has an extensive test site where PV modules and other system components are deployed and monitored for testing and evaluation. For this dataset PV Performance Labs has assembled one year of measurements from the Systems Long-Term Evaluation (SLTE) project (formerly known as PV Lifetime) providing the main variables needed to investigate and validate PV module operating temperature models: irradiance, ambient temperature, wind speed and back-of-module temperature. For use with more advanced thermal modeling, an estimate of down-welling long-wave radiation is also included.

14 SOLAR ENERGY↗

Modal testing with Asher's method using a Fourier analyzer and curve fitting

An unusual application of the method proposed by Asher (1958) for structural dynamic and modal testing is discussed. Asher's method has the capability, using the admittance matrix and multiple-shaker sinusoidal excitation, of separating structural modes having indefinitely close natural frequencies. The present application uses Asher's method in conjunction with a modern Fourier analyzer system but eliminates the necessity of exciting the test structure simultaneously with several shakers. Evaluation of this approach with numerically simulated data demonstrated its effectiveness; the parameters of two modes having almost identical natural frequencies were accurately identified. Laboratory evaluation of this approach was inconclusive because of poor experimental input data.

Gold, R. R.↗

Computer-Based Laboratory For Engine-System Monitors

Laboratory evaluates artificially intelligent engine-system monitors without potentially hazardous measurements on actual engines. Monitor enhances engine controller by detecting undesirable trends and counteracting them. Once proved in laboratory, monitor will then be tried on real engine.

Aguilar, Robert B.↗

Dynamic Evaluation of the Upper Tyler Formation and Well Stimulation Fluid Interactions Using Micro-CT Imaging

Abundant concentrations of swelling clays in the oil-bearing upper Tyler Formation inhibit unconventional well stimulation techniques and associated long-term oil and gas production success. Laboratory evaluation of the geochemical interactions between the formation material and various stimulation fluids may help identify innovative approaches that provide a solution to successful well stimulation and subsequent oil production. The objective of this research was to understand the complexities of well stimulation fluid and clay mineral interactions within the Tyler Formation and identify potential fracturing fluid formulations that mitigate swelling properties of the clays in the reservoir to enhance stimulation success and promote long-term oil and gas production. Collaboration with the National Energy Technology Laboratory (NETL), utilizing their Tescan DynaTOM micro-CT analysis instrumentation, provided an innovative approach to understand real-time, dynamic interactions of the formation material and various potential stimulation fluids. Results are anticipated to identify key mechanisms occurring at the micro-scale level and provide insight into modified stimulation techniques uniquely suited for successful production applications.

enhanced oil recovery↗

Infrared technology and applications; Proceedings of the Meeting, Cannes, France, November 26-29, 1985

The present conference on state-of-the-art IR systems and components technologies and their applications encompasses developments in IR systems design, production technologies, IR component testing, IR systems evaluations, laboratory and industrial applications, and aerospace ranging sensor and surveillance sensor applications. Attention is given to IR zoom lens telescopes, large zinc sulphide windows for airborne applications, thermal imaging system evaluation, minimum resolvable temperature difference measurement methods, industrial use of IR spectroscopy, platinum silicide sensor imagery, and recent developments in laser rangefinders.

Baker, Lionel R.↗

Accurate, reliable prototype earth horizon sensor head

The design and performance is described of an accurate and reliable prototype earth sensor head (ARPESH). The ARPESH employs a detection logic 'locator' concept and horizon sensor mechanization which should lead to high accuracy horizon sensing that is minimally degraded by spatial or temporal variations in sensing attitude from a satellite in orbit around the earth at altitudes in the 500 km environ 1,2. An accuracy of horizon location to within 0.7 km has been predicted, independent of meteorological conditions. This corresponds to an error of 0.015 deg-at 500 km altitude. Laboratory evaluation of the sensor indicates that this accuracy is achieved. First, the basic operating principles of ARPESH are described; next, detailed design and construction data is presented and then performance of the sensor under laboratory conditions in which the sensor is installed in a simulator that permits it to scan over a blackbody source against background representing the earth space interface for various equivalent plant temperatures.

Schwarz, F.↗

Crowd-Sourced Technology Challenge for Improving Visual Color Detection of Hydrazine and Monomethylhydrazine Vapors in Spacecraft Environments

NASA currently uses a visual colorimetric detection method for potential hydrazine, monomethylhydrazine (MMH), or unsymmetrical dimethylhydrazine (UDMH) contamination in the International Space Station. Astronauts exposed to propellants or their residues during extravehicular activities may transfer contaminants into the airlock. The colorimetric detection method employs the Contamination Detection Kit (CDK), which uses a potassium tetrachloroaurate redox reaction with the propellant hydrazine vapors and a color comparison card to determine airborne concentrations. Seeking ideas for improvement, the NASA Tournament Lab (NTL) crowdsourced a way to tackle the challenge of detecting hydrazine and MMH vapors using colorimetric detection methods. This Rid the Rocket competition drew over 200 participants and 20 submissions from around the world proposing innovative ways to develop a new chemical colorimetric detection method for hydrazine and MMH vapors on spacecraft. Using a phased approach to evaluate contestants, NASA eventually narrowed the field to five finalists from the United States, Romania, Taiwan, and India. Concept papers and hardware submissions were judged on feasibility, creativity, and ability to detect hydrazine and MMH vapors before being sent to the NASA White Sands Test Facility for laboratory evaluation. Finalists employed variations of sampling methods and color-detection chemistry using a variety of sampling pumps and indicator pads or solutions—including those employing potassium or hydrogen tetrachloroaurate, para -dimethylaminobenzaldehyde (PDAB), and modifiers including sodium metasilicate and cetyltrimethylammonium bromide—to enhance gold nanoparticle formation and surface plasmon resonance (SPR) resulting in visual blue to purple color development. This paper presents a summary of the crowdsourced submissions and results of laboratory testing.

Crowd-Sourced↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Human-in-the-Loop Evaluation of Dynamic Multi-Flight Common Route Advisories

Flights often experience large delays when they are routed around weather. Multi-flight common route advisories provide delay recovery by suggesting time-saving re-routes for groups of flights whose current weather-avoidance routes have become outdated because the weather has dissipated and/or moved away. A laboratory evaluation of these advisories was conducted by four subject matter experts having extensive experience in traffic flow management operations. These experts provided a total of 120 data points in the airspace of Houston Center. The multi-flight common route tool provides time-saving route change advisories taking into account flight plans, wind fields, and the spatio-temporal evolution of predicted convective weather. It is not designed to account for complex operational factors such as non-standard sector traversal and interactions with local traffic management initiatives; hence a relatively low percentage (37%) of advisories generated by the tool were rated as acceptable. However, a high percentage (81%) of advisories were rated as acceptable after the subject matter experts used the tool's user interface to make route modifications that accounted for relevant operational factors not considered by the tool. The workload associated with using the tool, as measured by the NASA Task Load Index, was quite low (1.1 on a scale of 0 to 10). The results of this evaluation make a good case for human-automation teaming to design operationally valid weather re-routes for delay recovery.

Traffic Flow Management↗

Signal analysis techniques for incipient failure detection in turbomachinery

Signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery were developed, implemented and evaluated. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques were implemented on a computer and applied to dynamic signals. A laboratory evaluation of the methods with respect to signal detection capability is described. Plans for further technique evaluation and data base development to characterize turbopump incipient failure modes from Space Shuttle main engine (SSME) hot firing measurements are outlined.

Coffin, T.↗

High Speed Digital Camera Technology Review

A High Speed Digital Camera Technology Review (HSD Review) is being conducted to evaluate the state-of-the-shelf in this rapidly progressing industry. Five HSD cameras supplied by four camera manufacturers participated in a Field Test during the Space Shuttle Discovery STS-128 launch. Each camera was also subjected to Bench Tests in the ASRC Imaging Development Laboratory. Evaluation of the data from the Field and Bench Tests is underway. Representatives from the imaging communities at NASA / KSC and the Optical Systems Group are participating as reviewers. A High Speed Digital Video Camera Draft Specification was updated to address Shuttle engineering imagery requirements based on findings from this HSD Review. This draft specification will serve as the template for a High Speed Digital Video Camera Specification to be developed for the wider OSG imaging community under OSG Task OS-33.

Clements, Sandra D.↗

Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and field evaluations a single vendor was recommended for use by NASA/IJSA Safety personnel. Vendor selection criteria, as well as the results from both laboratory and field testing of the multi-gas analyzers, are presented as part of this paper.

Lueck, D. E.↗

Investigation of the tone-burst tube for duct lining attenuation measurement

The tone burst technique makes practical the laboratory evaluation of potential inlet and discharge duct treatments. Tone burst apparatus requires only simple machined parts and standard components. Small, simply made, lining samples are quickly and easily installed in the system. Two small electromagnetric loudspeaker drivers produce peak sound pressure level of over 166 db in the 3-square-inch sample duct. Air pump available in most laboratories can produce air flows of over plus and minus Mach 0.3 in the sample duct. The technique uses short shaped pulses of sound propagated down a progressive wave tube containing the sample duct. The peak pressure level output of the treated duct is compared with the peak pressure level output of a substituted reference duct. The difference between the levels is the attenuation or insertion loss of the treated duct. Evaluations of resonant absorber linings by the tone burst technique check attenuation values predicted by empirical formulas based on full scale ducts.

Soffel, A. R.↗

Use of a silver-based sanitizer to accelerate Escherichia coli die-off on fresh-cut lettuce and maintain produce quality during cold storage: Laboratory and pilot-plant scale tests

Outbreaks and product recalls involving romaine and iceberg lettuce are frequently reported in the United States. Novel technologies are needed to inactivate pathogens without compromising product quality and shelf life. In this study, the effects of a process aid composed of silver dihydrogen citrate, glycerin, and lactic acid (SGL) on Escherichia coli and Listeria monocytogenes concentrations on lettuce immediately after washing and during cold storage were evaluated. Sensory and quality attributes of fresh-cut iceberg lettuce were also evaluated. Laboratory results indicated that application of SGL solution for 30 s as a first step in the washing process resulted in a 3.15 log reduction in E. coli O157:H7 immediately after washing. For E. coli O157:H7 a significant difference between SGL treatment and all other treatments was maintained until day 7. On day zero, SGL led to a 2.94 log reduction of L. monocytogenes. However, there was no significant difference between treatments with or without SGL regardless of storage time. Pilot-plant results showed that samples receiving SGL spray followed by chlorinated flume wash exhibited a greater reduction (1.48 log) in nonpathogenic E. coli populations at the end of shelf life than other treatments (p < 0.05). Additional pilot plant tests were conducted to investigate the hypothesis that SGL residues could continue to impact microbial survival on the final washed lettuce. Results show that pathogens introduced subsequent to flume washing of lettuce pretreated with SGL solution were not affected by antimicrobial residues. Here, the final quality and shelf life of flume washed lettuce were also unaffected by pretreatment with SGL. In conclusion, the results of this study demonstrate that this new technology has the potential to accelerate E. coli die-off on fresh-cut lettuce during cold storage and improve product safety, while not affecting quality throughout the shelf life of the finished products.

59 BASIC BIOLOGICAL SCIENCES↗

Signal Detection Techniques for Diagnostic Monitoring of Space Shuttle Main Engine Turbomachinery

An investigation to develop, implement, and evaluate signal analysis techniques for the detection and classification of incipient mechanical failures in turbomachinery is reviewed. A brief description of the Space Shuttle Main Engine (SSME) test/measurement program is presented. Signal analysis techniques available to describe dynamic measurement characteristics are reviewed. Time domain and spectral methods are described, and statistical classification in terms of moments is discussed. Several of these waveform analysis techniques have been implemented on a computer and applied to dynamc signals. A laboratory evaluation of the methods with respect to signal detection capability is described. A unique coherence function (the hyper-coherence) was developed through the course of this investigation, which appears promising as a diagnostic tool. This technique and several other non-linear methods of signal analysis are presented and illustrated by application. Software for application of these techniques has been installed on the signal processing system at the NASA/MSFC Systems Dynamics Laboratory.

Coffin, Thomas↗