Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “klystron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Improvements in X-band transmitter phase stability through klystron body temperature regulation

This article describes the techniques used and experimental results obtained in improving transmitter stability by control of the klystron body temperature. Related work in the measurement of klystron phase control parameters (pushing factors) is also discussed. The contribution of waveguide temperature excursions to uplink phase stability is presented. Suggestions are made as to the direction of future work in this area.

Perez, R. M.↗

Multi-frequency klystron designed for high efficiency

A multi-frequency klystron has an electron gun which generates a beam, a circuit of bunch-align-collect (BAC) tuned cavities that bunch the beam and amplify an RF signal, a collector where the beam is collected and dumped, and a standard output cavity and waveguide coupled to a window to output RF power at a fundamental mode to an external load. In addition, the klystron has additional bunch-align-collect (BAC) cavities tuned to a higher harmonic frequency, and a harmonic output cavity and waveguide coupled via a window to an additional external load.

47 OTHER INSTRUMENTATION↗

Experimental study of a low radio frequency power driven relativistic klystron amplifier

Using particle in cell simulation codes, a low radio frequency (rf) power driven relativistic klystron amplifier is designed according to the beam with current of 7.5 kA and voltage of 750 kV with special measures to avoid the mode competition. Simulated power reaches 1.7 GW when the driven rf power is 7.0 kW, the corresponding gain is 53.9 dB. Also the experiment is carried out on a telsa-typed accelerator, whose beam is with current of 8 kA and voltage of 800 kV. The measured rf output power reaches 2.04 GW in the experiment when the input rf power is 62 kW and frequency 2.850 GHz, the corresponding gain is 45.1 dB and efficiency is 32%. The maximum gain reaches 46.7 dB when the input decreases to 39 kW, the corresponding output rf power is 1.84 GW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Start-to-end modelling of a mode-locked optical klystron free electron laser amplifier

A free electron laser (FEL) in a mode-locked optical klystron (MLOK) configuration is modelled using start-to-end simulations that simulate realistic electron beam acceleration and transport before input into a full three-dimensional FEL simulation code. These simulations demonstrate that the MLOK scheme is compatible with the present generation of radiofrequency accelerator designs. A train of few-optical cycle pulses is predicted with peak powers similar to those of the equivalent conventional FEL amplifier. The role of electron beam energy modulation in these results is explained and the limitations of some simulation codes discussed. It is shown how seeding the FEL interaction using a High Harmonic seed laser can improve the coherence properties of the output.

43 PARTICLE ACCELERATORS↗

Factors influencing the microwave pulse duration in a klystron-like relativistic backward wave oscillator

In this paper, we analyze the factors that affect the microwave pulse duration in a klystron-like relativistic backward wave oscillator (RBWO), including the diode voltage, the guiding magnetic field, the electron beam collector, the extraction cavity, and the gap between the electron beam and the slow wave structure (SWS). The results show that the microwave pulse duration increases with the diode voltage until breakdown occurs on the surface of the extraction cavity. The pulse duration at low guiding magnetic field is generally 5-10 ns smaller than that at high magnetic field due to the asymmetric electron emission and the larger energy spread of the electron beam. The electron beam collector can affect the microwave pulse duration significantly because of the anode plasma generated by bombardment of the electron beam on the collector surface. The introduction of the extraction cavity only slightly changes the pulse duration. The decrease of the gap between the electron beam and the SWS can increase the microwave pulse duration greatly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and 3D simulation of a two-cavity wide-gap relativistic klystron amplifier with high power injection

By using an electromagnetic particle-in-cell (PIC) code, an S-band two-cavity wide-gap klystron amplifier (WKA) loaded with washers/rods structure is designed and investigated for high power injection application. Influences of the washers/rods structure on the high frequency characteristics and the basic operation of the amplifier are presented. Generally, the rod structure has great impacts on the space-charge potential depression and the resonant frequency of the cavities. Nevertheless, if only the resonant frequency is tuned to the desired operation frequency, effects of the rod size on the basic operation of the amplifier are expected to be very weak. The 3-dimension (3-D) PIC simulation results show an output power of 0.98 GW corresponding to an efficiency of 33% for the WKA, with a 594 keV, 5 kA electron beam guided by an external magnetic field of 1.5 Tesla. Moreover, if a conductive plane is placed near the output gap, such as the electron collector, the beam potential energy can be further released, and the RF power can be increased to about 1.07 GW with the conversion efficiency of about 36%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-efficiency overmoded klystron-like relativistic backward wave oscillator with low guiding magnetic field

A klystron-like relativistic backward wave oscillator with a ratio of transverse dimension to free-space wavelength being about four is presented. In the beam-wave interaction region, the electron beam interacts with surface wave and volume wave simultaneously. The cathode holder plays an important role in the reflection of backward waves. A guard electrode, an electron collector ring, and a reflection ring are used to optimize the beam-wave interaction. The particle in cell simulation results reveal that microwaves with a power of 2 GW and a frequency of 12.3 GHz are generated with an efficiency of 42% when the diode voltage is 400 kV, the beam current 12 kA, and the magnetic field 0.48 T.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and analysis of a radio frequency extractor in an S-band relativistic klystron amplifier

A radio frequency (RF) extractor converts the energy of a strongly modulated intense relativistic electron beam (IREB) into the energy of high power microwave in relativistic klystron amplifier (RKA). In the aim of efficiently extracting the energy of the modulated IREB, a RF extractor with all round coupling structure is proposed. Due to the all round structure, the operating transverse magnetic mode can be established easily and its resonant property can be investigated with an approach of group delay time. Furthermore, the external quality factor can be low enough. The design and analysis of the extractor applied in an S-band RKA are carried out, and the performance of the extractor is validated with three-dimensional (3D) particle-in-cell simulations. The extraction efficiency reaches 27% in the simulation with a totally 3D model of the whole RKA. The primary experiments are also carried out and the results show that the RF extractor with the external quality factor of 7.9 extracted 22% of the beam power and transformed it into the high power microwave. Better results are expected after the parasitic mode between the input and middle cavities is suppressed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase locking of an S-band wide-gap klystron amplifier with high power injection driven by a relativistic backward wave oscillator

Theoretical analyses and preliminary experiments on the phase-locking characteristics of an inductively loaded 2-cavity wide-gap klystron amplifier (WKA) with high power injection driven by a GW-class relativistic backward wave oscillator (RBWO) are presented. Electric power of the amplifier and oscillator is supplied by a single accelerator being capable of producing dual electron beams. The well phase-locking effect of the RBWO-WKA system requires the oscillator have good frequency reproducibility and stability from pulse to pulse. Thus, the main switch of the accelerator is externally triggered to stabilize the diode voltage and then the working frequency. In the experiment, frequency of the WKA is linearly locked by the RBWO. With a diode voltage of 530 kV and an input power of {approx}22 MW, an output power of {approx}230 MW with the power gain of {approx}10.2 dB is obtained from the WKA. As the main switch is triggered, the relative phase difference between the RBWO and the WKA is less than {+-}15 Degree-Sign in a single shot, and phase jitter of {+-}11 Degree-Sign is obtained within a series of shots with duration of about 40 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gigawatt peak power generation in a relativistic klystron amplifier driven by 1 kW seed-power

An S-band high gain relativistic klystron amplifier driven by kW-level RF power is proposed and studied experimentally. In the device, the RF lossy material is introduced to suppress higher mode excitation. An output power of 1.95 GW with a gain of 62.8 dB is obtained in the simulation. Under conditions of an input RF power of 1.38 kW, a microwave pulse with power of 1.9 GW, frequency of 2.86 GHz, and duration of 105 ns is generated in the experiment, and the corresponding gain is 61.4 dB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved power capacity in a high efficiency klystron-like relativistic backward wave oscillator by distributed energy extraction

With the efficiency increase of a klystron-like relativistic backward wave oscillator, the maximum axial electric field and harmonic current simultaneously appear at the end of the beam-wave interaction region, leading to a highly centralized energy exchange in the dual-cavity extractor and a very high electric field on the cavity surface. Thus, we present a method of distributed energy extraction in this kind of devices. Particle-in-cell simulations show that with the microwave power of 5.1 GW and efficiency of 70%, the maximum axial electric field is decreased from 2.26 MV/cm to 1.28 MV/cm, indicating a threefold increase in the power capacity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An X-band overmoded relativistic klystron

An X-band overmoded relativistic klystron is proposed, the operation mode of which is the TM{sub 02} mode. The drift tube could not cut off the TM{sub 01} mode; isolating the buncher cavity from the input cavity is achieved by introducing a sectional RF lossy material. Microwaves are extracted from the modulated electron beam using a cylindrical waveguide, rather than a coaxial waveguide; thereby, the output structure is significantly simplified. Particle-in-cell simulations show that microwaves with power of 1.28 GW and frequency of 9.30 GHz can be obtained, corresponding to an efficiency of 32% and relative bandwidth of about 8%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An S-band high gain relativistic klystron amplifier with high phase stability

For the purpose of coherent high power microwave combining, an S-band high gain relativistic klystron amplifier with high phase stability is presented and studied. By the aid of 3D particle-in-cell code and circuit simulation software, the mechanism of parasitic oscillation in the device is investigated. And the RF lossy material is adopted in the simulation and experiment to suppress the oscillation. The experimental results show that with an input RF power of 10 kW, a microwave pulse with power of 1.8 GW is generated with a gain of 52.6 dB. And the relative phase difference fluctuation between output microwave and input RF signal is less than ±10° in 90 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental study on parasitic mode suppression using FeSiAl in relativistic klystron amplifier

Experimental study of parasitic mode suppression using electromagnetic attenuate material FeSiAl in an S-band Relativistic Klystron Amplifier (RKA) is presented in this paper. The FeSiAl powder is coated and sintered onto the inner surface of a drift tube which locates between the input and the middle cavity of the RKA. Cold tests show that the attenuate rate of the tube against parasitic mode TE{sub 11} is about 50%. Experiments carried out on the Torch-01 accelerator present that the tube is effective in suppressing the parasitic mode. Two typical outputs are obtained. When the diode voltage is on a moderate level, the RKA operates well and the parasitic mode is totally suppressed. The pulse length of the High Power Microwave (HPM) almost equals the electron beam pulse length and the HPM average output power is about 300 MW, with a power efficiency of 10%. When the diode voltage is on a higher level, the output power and efficiency rise but the parasitic mode oscillation occurred and the pulse length is shortened. By contrast, the parasitic mode oscillation is too strong for the RKA to operate normally with un-sintered drift tube. The experimental study implies that FeSiAl is effective in suppressing the parasitic mode oscillation in a certain extent. However, total suppression needs a deeper attenuate rate and further investigation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An X-band high-impedance relativistic klystron amplifier with an annular explosive cathode

The feasibility of employing an annular beam instead of a solid one in the X-band high-impedance relativistic klystron amplifier (RKA) is investigated in theory and simulation. Small-signal theory analysis indicates that the optimum bunching distance, fundamental current modulation depth, beam-coupling coefficient, and beam-loaded quality factor of annular beams are all larger than the corresponding parameters of solid beams at the same beam voltage and current. An annular beam RKA and a solid beam RKA with almost the same geometric parameters are compared in particle-in-cell simulation. Output microwave power of 100 MW, gain of 50 dB, and power conversion efficiency of 42% are obtained in an annular beam RKA. The annular beam needs a 15% lower uniform guiding magnetic field than the solid beam. Our investigations demonstrate that we are able to use a simple annular explosive cathode immersed in a lower uniform magnetic field instead of a solid thermionic cathode in a complicated partially shielding magnetic field for designing high-impedance RKA, which avoids high temperature requirement, complicated electron-optical system, large area convergence, high current density, and emission uniformity for the solid beam. An equivalent method for the annular beam and the solid beam on bunching features is proposed and agrees with the simulation. The annular beam has the primary advantages over the solid beam that it can employ the immersing uniform magnetic field avoiding the complicated shielding magnetic field system and needs a lower optimum guiding field due to the smaller space charge effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a Ku band miniature multiple beam klystron

The design of a miniature multiple beam klystron (MBK) working in the Ku-band frequency range is presented in this article. Starting from the main design parameters, design of the electron gun, the input and output couplers and radio frequency section (RF-section) are presented. The design methodology using state of the art commercial electromagnetic design tools, analytical formulae as well as noncommercial design tools are briefly presented in this article.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A novel technique for tuning of co-axial cavity of multi-beam klystron

Multi-beam Klystrons (MBKs) have gained wide acceptances in the research sector for its inherent advantages. But developing a robust tuning technique for an MBK cavity of coaxial type has still remained a challenge as these designs are very prone to suffer from asymmetric field distribution with inductive tuning of the cavity. Such asymmetry leads to inhomogeneous beam-wave interaction, an undesirable phenomenon. Described herein is a new type of coaxial cavity that has the ability to suppress the asymmetry, thereby allowing tuning of the cavity with a single tuning post.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Retrofitting the 5045 Klystron for Higher Efficiency

The 5045 klystron has been in production and accelerating particles at SLAC National Accelerator Laboratory for over 25 years. Although the design has undergone some changes there are still significant opportunities for improvement in performance. Retrofitting the 5045 for higher efficiencies and a more mono-energetic spent beam profile is presented.

43 PARTICLE ACCELERATORS↗