Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “isotope quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

ORNL Contributions to the ENDF/B-VIII.1 Library [Slides]

For uranium and plutonium isotopes, evaluation work is converging to a stable configuration with an overall satisfactory benchmark performance (more information on the validation tests after CSEWG). Strontium evaluation was included in the repository library and successfully tested by processing codes relative to an alternative quantification of the external function. Cerium covariance matrices were updated to address review comments on the magnitude of the uncertainty. For future uncertainty quantification, theoretical observables should be properly decoupled from current measured guidelines. Tests to correctly include LP (from resonance parameters) fitted to measured energy-averaged data are in progress. Current ENDF files contains experimental LP data.

07 ISOTOPE AND RADIATION SOURCES↗

Capillary absorption spectroscopy for high temporal resolution measurements of stable carbon isotopes in soil and plant-based systems

Capillary Absorption Spectroscopy (CAS) is a relatively new analytical technique for performing stable isotope analysis. Here, we demonstrate the utility of CAS by recording and quantifying variation in 13C in controlled and biologically relevant applications. We calibrated CAS system response to increased 13CO2, with an observed ~4‰ increase in measured Δ13C for each 0.03 ppm shift in 13CO2 concentration. We leveraged this calibration to quantify rates of biogeochemical processes using a 13C tracer. For example, we monitored microbial respiration of 13C-glucose within an agricultural soil at 10 s quantification intervals and results demonstrated 8.6% ± 0.4 of added glucose was converted to 13CO2 within 1.5 h of incubation. We expanded the demonstration by adapting a rhizobox to permit continuous monitoring of 13CO2 in a soil (as distinct from plant) headspace to track the timing and quantify respiration rates of fresh plant photosynthate and observed a 3.5 h delay between plant exposure to a13CO2 tracer and the first signs of respiration by soil biota. These experiments highlight CAS is effective in producing high temporal resolution quantification of 13CO2 and demonstrate potential applications.

13CO2↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Measuring the β-decay Properties of Neutron-rich Exotic Pm, Sm, Eu, and Gd Isotopes to Constrain the Nucleosynthesis Yields in the Rare-earth Region

Abstract The β -delayed neutron-emission probabilities of 28 exotic neutron-rich isotopes of Pm, Sm, Eu, and Gd were measured for the first time at RIKEN Nishina Center using the Advanced Implantation Detector Array (AIDA) and the BRIKEN neutron detector array. The existing β -decay half-life ( T 1/2 ) database was significantly increased toward more neutron-rich isotopes, and uncertainties for previously measured values were decreased. The new data not only constrain the theoretical predictions of half-lives and β -delayed neutron-emission probabilities, but also allow for probing the mechanisms of formation of the high-mass wing of the rare-earth peak located at A ≈ 160 in the r -process abundance distribution through astrophysical reaction network calculations. An uncertainty quantification of the calculated abundance patterns with the new data shows a reduction of the uncertainty in the rare-earth peak region. The newly introduced variance-based sensitivity analysis method offers valuable insight into the influence of important nuclear physics inputs on the calculated abundance patterns. The analysis has identified the half-lives of 168 Sm and of several gadolinium isotopes as some of the key variables among the current experimental data to understand the remaining abundance uncertainty at A = 167–172.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear data uncertainty quantification for the nuclide inventory of a Calvert Cliffs spent fuel sample

The impact of nuclear data cross section uncertainties and covariance matrices on the nuclide vector of spent nuclear fuel was investigated; This exercise was carried out for the Calvert Cliffs fuel assembly D047 benchmark available in the SFCOMPO database. Sample P irradiated in rod MKP109 for 4 cycles up to a burnup of approximately 44 GWd/MTU was selected for the analysis. Nuclear data uncertainties were taken from the most recent libraries released by evaluation projects JEFF, ENDF/B and JENDL, and were propagated using the SANDY code via a stochastic sampling approach. This paper provides a quantification of the uncertainty on the concentration of several actinides and fission products relevant for spent fuel management. Uncertainties generally below 5 % were predicted for the concentrations of most of the uranium, neptunium and plutonium isotopes relevant for SNF applications. Curium isotopes carry larger uncertainties that might exceed 10 %. The contribution of cross section uncertainties on the concentrations of fission products was found to be marginal with the exception of a few nuclides. These results can be significantly affected by the lack of evaluated covariance matrices for the capture cross section of several fission products. Burnup tracers such as {sup 148}Nd and {sup 137}Cs have negligible uncertainties because of the power normalisation imposed in every stochastic calculation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retaining Geochemical Signatures during Aragonite-Calcite Transformation at Hydrothermal Conditions

Transformation of aragonite, a mineral phase metastable at Earth’s surface, to calcite widely occurs in both sedimentary and metamorphic systems with the presence of an aqueous phase. The transformation process can affect geochemical signatures of aragonite (a protolith). This study focused on quantification of the retention of Mg/Ca and Sr/Ca ratios, and δ18O during the transformation process as well as evaluation of the transformation rate. To investigate the effect of transformation from aragonite to calcite on elemental and stable isotope ratios, we conducted a series of experiments in NaCl solutions at temperatures between 120 and 184 °C. Two additional experiments at 250 °C were conducted to estimate the transformation rate of aragonite to calcite. Protolith materials consist of (1) synthetic (Mg; Sr-bearing or non-Mg; Sr bearing) needle-shaped microcrystals of aragonite (<5 µm in size) and (2) larger chips (>100 µm in size) of natural aragonite. X-ray diffraction (XRD) showed that microcrystals successfully transformed to calcite within 30 h and scanning electron microscopy (SEM) yielded a change in the crystal size to >10 µm in rhombohedral shape. Electron backscatter diffraction (EBSD) of the larger aragonite chips showed that transformation to randomly oriented calcite occurred at the rims and along the cracks while the core retained an aragonite crystal structure. Isotope-ratio mass spectrometry (IRMS) analyses showed that calcite δ18O was controlled by temperature and δ18O of the solution. The obtained calibration curve of isotope fractionation factor versus temperature is consistent with other studies. Inductively coupled plasma optical emission spectroscopy (ICP-OES) analyses showed that calcite partially or completely retained Mg/Ca and Sr/Ca ratios through the transformation.

58 GEOSCIENCES↗

Status, Challenges, and Plans for Consistent Modeling and Evaluation of Fission Data: Nubar, PFNS, and FPY [Slides]

This presentation discusses the importance of consistent evaluations for fission observables. Currently, prompt fission quantities (e.g., neutron multiplicity, neutron energy spectrum, and fission product yields) are evaluated independently of one another, either with separate models or data-only/non-model evaluations (few – if any – shared model inputs) and inconsistencies can arise in evaluated data (e.g. NSE 190, 258 (2018)). They have found that consistent, model-based evaluations lead to more physical constraints on free parameters in the model, more robust predictions for other observables and other isotopes, that there are correlations between the uncertainties on different observables, and that uncertainties can be propagated to unmeasured quantities. They are working on developing models to the point where fission observables are calculated at the quality needed for an evaluation. They are striving to consistently calculate fission observables, such as $\bar{v}$, PFNS, and FPY, to a quality suitable for an evaluation. Current evaluations for fission observables use separate models for each observable (with minimal shared input) or are purely data driven. LANL models, such as the Monte Carlo CGMF and deterministic BeoH, have different strengths; the similar fission fragment initial conditions and decay models leads to consistency between the two codes (FPY can be connected to $\bar{v}$ and PFNS, even when calculated by different codes). Work is underway by Lovell to optimize the models and Neudecker is working to perform detailed uncertainty quantification. The PFNS, in particular, presents a significant challenge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Role of surface diffusion in formation of unique reactivity for graphite oxidation: Time-resolved measurements in a pulsed diffusion reactor

Quantification of oxidation kinetics is essential to develop graphitic materials for diverse applications: from refractories found in gas-cooled nuclear reactors to catalysts needed for chemical manufacturing. In this work, using well-defined highly oriented pyrolytic graphite, low-pressure isotopic transient experiments combined with controlled annealing periods, we resolve the role of surface diffusion and quantify oxidation kinetics with nanomole-precision. We observe an unexpected increase in reactivity following annealing which is explained by the role of surface diffusion increasing the probability for trapping mobile oxygen at more reactive edge sites. Here, the locus of adsorption and spillover to the basal plane is distinct from the trapping location creating a more active oxygen species. Isotopic products reflect the population dynamics of oxygen added at the edge and surface diffusion that relocates basal plane oxygen to more reactive edge sites. Since this process proceeds in parallel with direct oxidation reactions, it is not likely to be observed using steady-state or conventional ‘bulk’ characterization techniques. Our unique time-resolved non-equilibrium measurement in a well-defined transport regime, enables observation of three distinct behaviors: short-term deactivation due to the balance of rates in oxygen supply/product formation, reactivity increases due to surface diffusion and longer-term reactivity increase with oxygen accumulation.

36 MATERIALS SCIENCE↗

An automated workflow that generates atom mappings for large‐scale metabolic models and its application to Arabidopsis thaliana

SUMMARY Quantification of reaction fluxes of metabolic networks can help us understand how the integration of different metabolic pathways determines cellular functions. Yet, intracellular fluxes cannot be measured directly but are estimated with metabolic flux analysis (MFA), which relies on the patterns of isotope labeling of metabolites in the network. The application of MFA also requires a stoichiometric model with atom mappings that are currently not available for the majority of large‐scale metabolic network models, particularly of plants. While automated approaches such as the Reaction Decoder Toolkit (RDT) can produce atom mappings for individual reactions, tracing the flow of individual atoms of the entire reactions across a metabolic model remains challenging. Here we establish an automated workflow to obtain reliable atom mappings for large‐scale metabolic models by refining the outcome of RDT, and apply the workflow to metabolic models of Arabidopsis thaliana . We demonstrate the accuracy of RDT through a comparative analysis with atom mappings from a large database of biochemical reactions, MetaCyc. We further show the utility of our automated workflow by simulating 15 N isotope enrichment and identifying nitrogen (N)‐containing metabolites which show enrichment patterns that are informative for flux estimation in future 15 N‐MFA studies of A. thaliana . The automated workflow established in this study can be readily expanded to other species for which metabolic models have been established and the resulting atom mappings will facilitate MFA and graph‐theoretic structural analyses with large‐scale metabolic networks.

59 BASIC BIOLOGICAL SCIENCES↗

Fission Product Quantification and Burnup Analysis via Gamma Spectrometry of the AGR-5/6/7 TRISO Fuel Experiment

Five capsules containing varying configurations of TRISO fuel compacts were irradiated in the most recent Advanced Gas Reactor (AGR) TRISO test campaign, AGR-5/6/7. As part of the post-irradiation examination (PIE) of this work all the fuel compacts and capsule graphite holders were measured with the Precision Gamma Scanner (PGS) to determine isotopic activities and locations using gamma spectrometry. Measuring the compacts allowed for the comparison of physics model depletion calculations with the measured compact activity to validate models. These measurements also are used to find compacts of interest with low fission product retention that may be tested in subsequent PIE. Measurements of the holders can confirm fission product distribution and migration. Of the isotopes measured, Cs-137 and Cs-134 were used to estimate location of failed particles as well as determine a measured burnup estimation. Results from Capsule 1 compacts and the holder indicate many fuel particle failures occurred. There are high amounts of cesium in the holder near Stack 9 of Capsule 1 that corresponds to low fractions?measured-to-calculated (M/C) ratio?of cesium remaining in those compacts. All other capsules had cesium retention ratios near 1. The isotope 110mAg had less consistent results. Capsule 2 compacts exhibited a M/C of 0.20, much lower than anticipated for the temperatures these compacts underwent. Capsule 3 experienced much higher temperatures, >1300C and had an average M/C of 0.75. These are the opposite results than what was predicted by past AGR experiments for the relationship between temperature and isotope retention. Capsule 4 and 5 showed good fission product retention and agreement with the physics model predictions. The burnup results from the PGS measurements showed strong agreement between the physics models and the measured values. Using a ratio of Cs-134/Cs-137 to calculate the burnup match closely with the physics models. Additionally, the Cs-137 burnup results were less accurate but extremely close to the model results.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biomolecular budget of persistent, microbial-derived soil organic carbon: The importance of underexplored pools

The details of how soil microorganisms contribute to stable soil organic carbon pools are a pressing knowledge gap with direct implications for soil health and climate mitigation. It is now recognized that microbial necromass contributes substantially to the formation of stable soil carbon. However, the quantification of necromass in soils has largely been limited to model molecules such as aminosugar biomarkers. The abundance and chemical composition of other persistent microbial residues remain unresolved, particularly concerning how these pools may vary with microbial community structure, soil texture, and management practices. We use yearlong soil incubation experiments with an isotopic tracer to quantify the composition of persistent residues derived from microbial communities inhabiting sand or silt dominated soil with annual (corn) or perennial (switchgrass) monocultures. Persistent microbial residues were recovered in diverse soil biomolecular pools including metabolites, proteins, lipids, and mineral-associated organic matter (MAOM). The relative abundances of microbial contributions to necromass pools were consistent across cropping systems and soil textures. The greatest residue accumulation was not recovered in MAOM but in the light density fraction of soil debris that persisted after extraction by chemical fractionation using organic solvents. Necromass abundance was positively correlated with microbial biomass abundance and revealed a possible role of cell wall morphology in enhancing microbial carbon persistence; while gram-negative bacteria accounted for the greatest contribution to microbial-derived carbon by mass at one year, residues from gram-positive Actinobacteria and Firmicutes showed greater durability. Together these results offer a quantitative assessment of the relative importance of diverse molecular classes for generating durable soil carbon.

54 ENVIRONMENTAL SCIENCES↗

252 Cf yield calibration method for nuclear material accountancy and safeguards practitioners

Californium-252 is an isotope commonly encapsulated as a physically small but strong spontaneous fission neutron source for applications in industry, academia, and research. Within the nuclear safeguards community, a well-characterized 252 Cf source is often used as an accessible alternative for plutonium in calibrations measurements, which require the absolute source strength. Current methods of source strength quantification can provide an accurate estimate, approximately 1% uncertainty under optimal conditions, but are typically costly and time consuming. An alternative method was developed to determine 252 Cf source strength using passive neutron correlation counting (PNCC). The PNCC method enables institutions and facilities to perform 252 Cf source calibration measurements in-house using detection systems that are common within the nuclear safeguards community. This novel method was previously successfully demonstrated using neutron multiplicity well counters. However, the previous evaluation utilized detection systems with high neutron detection efficiencies, greater than 60%. The purpose of the current study is to extend the previous evaluation and demonstrate the feasibility of the PNCC 252 Cf calibration method for suite of coincidence counters with lower neutron detection efficiencies, between 15% and 35%, which are more commonly encountered in the field, as well as to provide a step-by-step guide to using the method. The neutron source used in this evaluation was previously certified by the National Institutes of Science and Technology (NIST), which provides a reference for the accuracy of the PNCC method. In conclusion, the present source yield calculations demonstrate excellent agreement with a NIST calibration technique and achieve a standard uncertainty below the target 1%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-collector ICP-MS method for quantification of plutonium, uranium, and americium in hair and nails of occupationally or medically exposed individuals

The 239 Pu, 238 U, and 241 Am concentrations and 239 Pu/ 240 Pu, 235 U/ 238 U, and 236 U/ 238 U atom ratios were measured in the hair and nail samples from individuals who donated their bodies to the United States Transuranium and Uranium Registries. Further, the concentration of 239 Pu ranged from 0.22–15.8 ng/kg. The 240 Pu/ 239 Pu isotopic ratios ranged from 0.026 to 0.127 which is consistent with weapons-grade plutonium. Concentration of uranium fell between 1.84 µg/kg and 29.5 µg/kg and 235 U/ 238 U ratios ranged from 4.8×10 -3 to 7.6×10 -3 . Elevated 236 U/ 238 U atom ratios were measured in two cases and ranged from 5.0×10 -6 – 2.4×10 -5 indicating exposure to spent or reprocessed uranium material. The concentration of 241 Am was measured in four hair samples and ranged from 0.02–0.21 ng/kg.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detection and Quantification of Nitrogen Compounds in Martian Solid Samples by the Sample Analysis at Mars (SAM) Instrument Suite

The Sample Analysis at Mars (SAM) instrument suite on the Mars Science Laboratory (MSL) Curiosity Rover detected both reduced and oxidized nitrogen-bearing compounds during the pyrolysis of surface materials from three sites at Gale Crater. Preliminary detections of nitrogen species include NO, HCN, ClCN, CH3CN, and TFMA (trifluoro-Nmethyl-acetamide). On Earth, nitrogen is a crucial bio-element, and nitrogen availability controls productivity in many environments. Nitrogen has also recently been detected in the form of CN in inclusions in the Martian meteorite Tissint, and isotopically heavy nitrogen (delta N-15 approx +100per mille) has been measured during stepped combustion experiments in several SNC meteorites. The detection of nitrogen-bearing compounds in Martian regolith would have important implications for the habitability of ancient Mars. However, confirmation of indigenous Martian nitrogen bearing compounds will require ruling out their formation from the terrestrial derivatization reagents (e.g. N-methyl-N-tert-butyldimethylsilyl-trifluoroacetamide, MTBSTFA and dimethylformamide, DMF) carried for SAM's wet chemistry experiment that contribute to the SAM background. The nitrogen species we detect in the SAM solid sample analyses can also be produced during laboratory pyrolysis experiments where these reagents are heated in the presence of perchlorate, a compound that has also been identified by SAM in Mars solid samples. However, this does not preclude a Martian origin for some of these compounds, which are present in nanomolar concentrations in SAM evolved gas analyses. Analysis of SAM data and laboratory breadboard tests are underway to determine whether nitrogen species are present at higher concentrations than can be accounted for by maximum estimates of nitrogen contribution from MTBSTFA and DMF. In addition, methods are currently being developed to use GC Column 6, (functionally similar to a commercial Q-Bond column), to separate and identify unretained compounds such as NO, N2O, and NO2, which are difficult to detect by EGA-MS due to mass interferences at 30, 44 and 46, respectively. Here we present evolved gas analysis-mass spectrometry (EGA-MS) and gas chromatography mass spectrometry (GC-MS) data on the identification and quantification of these nitrogen-bearing compounds, and suggestions for their origins

Stern, Jennifer C.↗

Evaluate opportunities for monitoring the oxidation states of technetium in both organic and aqueous phases using Raman spectroscopy

An important isotope in the nuclear fuel cycle, 99 Tc is characterized by its long half-life of 2.1 × 10 5 years and its beta emission. It is generated through the fission of 235 U. As the burnup levels of nuclear waste continue to rise, the concentration of technetium in spent fuel increases, leading to a heightened interest in its quantification during the reprocessing of spent nuclear fuel. In HNO3 environments, technetium predominantly exists as TcO 4 − ; however, it tends to interfere with reducing agents, decreasing the separation efficiency for actinides. Therefore, accurate quantitative determination of technetium is critical to controlling its distribution and mitigating its negative effect on the reprocessing of spent fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

NanoSIP: NanoSIMS Applications for Microbial Biology

High-resolution imaging with secondary ion mass spectrometry (nanoSIMS) has become a standard method in systems biology and environmental biogeochemistry and is broadly used to decipher ecophysiological traits of environmental microorganisms, metabolic processes in plant and animal tissues, and cross-kingdom symbioses. When combined with stable isotope-labeling—an approach we refer to as nanoSIP—nanoSIMS imaging offers a distinctive means to quantify net assimilation rates and stoichiometry of individual cell-sized particles in both low- and high-complexity environments. While the majority of nanoSIP studies in environmental and microbial biology have focused on nitrogen and carbon metabolism (using 15 N and 13 C tracers), multiple advances have pushed the capabilities of this approach in the past decade. The development of a high-brightness oxygen ion source has enabled high-resolution metal analyses that are easier to perform, allowing quantification of metal distribution in cells and environmental particles. New preparation methods, tools for automated data extraction from large data sets, and analytical approaches that push the limits of sensitivity and spatial resolution have allowed for more robust characterization of populations ranging from marine archaea to fungi and viruses. Further, NanoSIMS studies continue to be enhanced by correlation with orthogonal imaging and ‘omics approaches; when linked to molecular visualization methods, such as in situ hybridization and antibody labeling, these techniques enable in situ function to be linked to microbial identity and gene expression. Here we present an updated description of the primary materials, methods, and calculations used for nanoSIP, with an emphasis on recent advances in nanoSIMS applications, key methodological steps, and potential pitfalls.

07 ISOTOPE AND RADIATION SOURCES↗