Sputtering ion source study program Final report, 29 Jan. - 15 Nov. 1962
Design, construction, assembly, and operation of ion source for solids
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design, construction, assembly, and operation of ion source for solids
Quantitative mass analysis of solid surfaces by sputtering ion source
Field evaporation of solid metal electrodes has been proposed as an ion source for an electrostatic propulsion device. The chief advantage over existing ion sources is the prospect of 100 percent fuel utilization efficiency. This advantage arises as a result of the elimination of the need for a gaseous precursor state for propellant ionization. The attainment of required high surface field strengths is achieved through field-induced extrusion of the electrode geometry at elevated temperatures. Contributions of both surface and bulk transport mechanisms are taken into account.
Modified sputtering ion source analyses of solids
Estimation of gross performance characteristics of low density electron bombardment ion source
We present two iterations of the Multicusp Ion Source Technology at MIT (MIST) sources, designed to fulfill the requirements of the HCHC-XX cyclotron design. The HCHC-XX is a novel compact cyclotron accelerating $H$$^{+}_{2}$. Beam is injected through a radio-frequency quadrupole buncher-accelerator (embedded in the cyclotron yoke) and utilizes so-called vortex motion during acceleration. If successful, it will deliver 10 mA of protons at 60 MeV in CW mode. This scheme requires a low-emittance, high-current initial beam with high $H$$^{+}_{2}$ purity. We briefly summarize the design and previous results of the MIST-1 ion source and, for the first time, the detailed design of the new and improved MIST-2, including the mechanical, electrical, and control system design. We further show experimental results of using the MIST-2 backplate on the MIST-1 body, present a study using different types of permanent magnets for confinement (including no magnets), and finally, we present first results of the MIST-2 in full operation. In this first commissioning run, we were able to increase the total extracted current from the MIST-2 to 7 mA—a factor of 2 over the MIST-1.
Particle accelerators are among the most important scientific tools of the modern era. Large accelerator complexes have supported scientific user facilities which have had an enormous societal impact spanning many decades and enabling the work of thousands of scientific users worldwide contributing to many Nobel prizes in physics, biology and chemistry [1]. Many of the large hadron facilities employ accelerator complexes which include cyclotrons, synchrotrons, storage rings, linear or tandem accelerators and deliver ion beams of very high-intensity and/or very high-energy to their user facilities. These accelerator complexes require the injection of high-intensity beams of ions which are produced within an ion source and formed within a plasma or by bombardment of a surface [2]. Increasingly, RF systems are being utilized, to generate these ion-rich plasmas due to their high reliability and minimal use of consumable components. This report will first discuss the basic mechanisms of ion formation and plasma generation as well as some specifics of RF/microwave generators, matching circuits and plasma coupling structures typically employed. A detailed discussion will then be given of the RF-driven negative ion source systems employed by US Spallation Neutron Source as well as those used in similar facilities located around the globe. REFERENCES [1]Vladimir Shiltsev, “Particle beams behind physics discoveries”, Physics Today 73, Issue 4, 32 (2020) [2]Robert Welton et al, “Negative hydrogen ion sources for particle accelerators: Sustainability issues and recent improvements in long-term operations”, Journal of Physics Conf Series, 2244 012045
Open ion source mass spectrometer used with omegatron mass spectrometer to measure atmospheric gas density and composition in thermosphere probe experiment
The U.S. Spallation Neutron Source (SNS) is a state-of-the-art neutron scattering facility delivering the world's most intense pulsed-neutron beams to a wide array of instruments which are used to conduct investigations in many fields of science and engineering. The accelerator system is fed by an RF-driven, multicusp, H - ion source which nominally provides pulsed beam currents of 50-60 mA (1ms, 60Hz). This report provides a discussion of ongoing design improvements to the SNS ion source and Low Energy Beam Transport (LEBT) as well as diagnostic upgrades undertaken since the previous ICIS conference. These improvements include (i) simple mechanical modifications to the source outlet aperture which resulted in dramatically increased extracted beam current and comparable or lower emittance at similar beam currents, (ii) design improvements to the LEBT chopper target which will enable full power beam-dumping during physics studies, (iii) refinement of the SNS Allison emittance scanner that has enabled the first reliable LEBT beam measurements at full beam power (65kV, 50-100mA, 1ms, 60Hz) on the SNS ion source test stand and (iv) the implementation of a thermal imaging camera for the monitoring the LEBT electrode temperatures. (v) The design of an advanced Cs system, capable of more efficient Cs utilization with significantly lower Cs losses from the source is also presented. Mechanical details, computational simulations and experimental results are discussed within the context of these improvements.
We experimentally proved the feasibility of a liquid-based target for Laser Ion Source (LIS) application. The target consists of melted metal gallium contained in a heated crucible. Ions current resulting from laser irradiation. Moreover, given the explosive ablation mechanism involved, each laser shot has been found to induce fluctuations in the surface level. It takes about 0.7 sec to recover the steady condition fully. Despite the maximum fluctuation being 2.7 mm (top-bottom maximum displacement), these fluctuations have shown no significant influence on total ion current and are independent of the temperature of the sample within the tested repetition rate. This study provides valuable insights into the potential of employing such a system for LIS.
High current electron bombardment ion source for production of low energy ion beams without metastable contamination
Here, the current Electron Cyclotron Resonance Ion Sources (ECRISs), constructed with Nb-Ti wires and the conventional racetrack-and-solenoid structure, have achieved operating frequencies up to 28 GHz and utilized about 90% of the critical current of the Nb-Ti wire. A Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system, which consists of an innovative hexagonal Closed-Loop Coil (CLC) and a set of solenoids, can generate higher magnetic fields (up to 150% ) while requiring only about 50% of the superconducting wire, enabling Nb-Ti wires to be used in the next-generation 45 GHz ECRIS. However, the assembly and cooling of such an efficient and compact magnet are particularly challenging due to the small radial gap between the CLC and solenoids, as well as the tight operating temperature margin. To address these challenges, a structure was developed that combines a three-section radially split solenoid mandrel with a series of shrink-fit reinforcement rings and cooling channels. This paper presents the detailed structure, manufacturing method, assembly procedure, impregnation method, mechanical Finite Element Analysis (FEA) comparison, and thermal FEA comparison.
An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.
Here, the Extended Electron Beam Ion Source (EEBIS) has been installed and commissioned at Brookhaven National Laboratory (BNL) hadron accelerator complex in the spring of 2023. EEBIS has replaced its predecessor, RhicEBIS, which provided ions for BNL hadron facilities for over a decade since 2009. The motivations for the source upgrade are to provide higher intensities of the Au 32+ ion beam for the Relativistic Heavy Ion Collider (RHIC) and to provide of an intense source of polarized 3 He 2+ ions for the future Electron Ion Collider (EIC) at BNL. EEBIS is and will continue to be the primary source for a variety of different ion species for the NASA Space Radiation Laboratory (NSRL) at BNL. EEBIS utilizes two identical, two-meter-long unshielded 5T warm bore superconducting solenoids, and it is operated with electron beam current up to 10 A, providing a high-capacity ion traps to fulfill the requirement for high intensity ion beams. The upstream solenoid contains a “short ion trap” with a length of 95 cm, while the “long ion trap” with a length of 178 cm is located inside the downstream solenoid bore. The main features of EEBIS are: * A Gas injection and ionization cell equipped with a Lorenz pulse valve * High-capacity ZAO non-evaporable getter (NEG) custom linear pumping units * In situ apparatus for pumping speed measurements to monitor NEG activation and saturation * “External drift tube” construction with differential pumping stages to provide space for Lorentz pulse valve and 3 He high-field polarization cell * A Ba oxide electron gun cathode. The design of EEBIS as well as the results of its commissioning and first-year operation are presented and discussed.
Use of pure isotope 86Kr instead of natural krypton in multiple-species ion source enables source to produce krypton ions separated from argon ions by tuning cylcotron with which source used. Addition of capability to produce and separate krypton ions at kinetic energies of 150 to 400 MeV necessary for simulation of worst-case ions occurring in outer space.
Sputtering ion source for analysis of solids
Electron bombardment of propellant gas using a mercury ion source
Plasma-ion source system for ground calibration of Bennett RF ion mass spectrometer