Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “interval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Incremental Interval Assignment (IIA) for Scalable Mesh Preparation

Interval Assignment (IA) means selecting the number of mesh edges for each CAD curve. IIA is a discrete algorithm over integers. A priority queue iteratively selects compatible sets of intervals to increase in lock-step by integers. In contrast, the current capability in Cubit is floating-point Linear Programming with Branch-and-Bound for integerization (BBIA).

97 MATHEMATICS AND COMPUTING↗

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

Power outages cause significant economic and societal impacts. An increasing likelihood of extreme weather coupled with aging grid infrastructure is leading to a higher prevalence of extended power outages, which can leave customers without power for multiple days or even weeks. Planners at the facility, local, state, and federal levels are interested in resilience solutions to reduce the impacts of extended power outages. Resilience solutions—such as installing backup systems, integrating microgrid solutions, weatherizing buildings, and hardening distribution and transmission components—can reduce the consequences of extended power outages, but these solutions come with increased capital costs. Conducting cost-benefit analyses is important for determining which steps to take to mitigate the impact of power outages without investing in ineffective and cost-prohibitive resilience solutions. The expected benefits of resilience investments depend on the frequency of power outages of various durations, particularly extended outages lasting several hours, days, or weeks. A significant barrier to resilience planning is the lack of publicly available data on the frequency and duration of extended power outages. The absence of outage duration information severely limits the ability to conduct quantitative cost-benefit analyses of resilience investments. This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies. We developed a methodology to estimate customer outage durations for extended outage events using publicly available data on customer outages. Shorter-duration power outages are relatively common, with customers experiencing on average more than one power outage each year lasting fewer than 12 hours. An outage event lasting between 1 day and 1 week is expected to occur between once every 16 years and once every 42 years, depending on the region, with an average recurrence rate of once every 32 years across the contiguous United States.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing or timing system implementation tasks, it is often desirable to generate signal pulses with fine adjustable time intervals. In delay cell-based schemes, the time adjustment steps are limited by the propagation delays of the cells, which are typically 15 to 20 picoseconds per step and are sensitive to temperature and operating voltage. In this document, a purely digital scheme based on two vernier clocks with small frequency difference generated using cascaded PLL is reported. The scheme is tested in two families of low-cost FPGA and 0.67 and 0.97 picoseconds adjustable steps of the time intervals are achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exceedance Probabilities and Recurrence Intervals for Extended Power Outages in the United States

This report provides estimates of recurrence intervals and conditional exceedance probabilities for major power outages by U.S. region between 2015 and 2021. Additionally, we provide estimates for grid management, particularly outages caused by California’s public safety power shutoffs (PSPS), and for natural outages caused by major hurricanes. Outage recurrence intervals are the average number of years between outage events, and conditional exceedance probabilities are the likelihoods that a customer who experiences a major power outage will experience an outage exceeding a given duration. Major outage events are those that affect 10,000 or more customers, as defined by the U.S. Department of Energy’s (DOE’s) Electric Emergency Incident and Disturbance Report, called OE-417 (DOE 2020). These results can be applied to determine the likelihood of experiencing long-duration outages, which can be integrated into cost-benefit analyses of resilience solutions and broader energy resilience studies.

Ericson, Sean↗

300 Area VOC Program Slug Test Characterization Results for Selected Test/Depth Intervals for Wells 399-2-5, 399-3-22, and 399-4-14

Multiple, stress-level slug tests were performed at selected test/depth intervals within wells 399-2-5, 399-3-22, and 399-4-14 as part of the 300 Area volatile organic compound characterization program at the Hanford Site in Washington State. The temporary test screen lengths were characterized as the boreholes were advanced to their final drill depths and before their completion as monitor-well facilities. Following well completion, slug tests were performed in the final, completed well-screen sections. The objectives of the slug tests were to provide the vertical distribution of hydraulic conductivity with depth at these locations and to support selection of the final well screen-depth interval for each of these monitor-well facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Slug Test Characterization Results for Multi-Test/Depth Intervals Conducted During the Drilling of CERCLA Operable Unit OU ZP-1 Wells 299-W11-43, 299-W15-50, and 299-W18-16

The following report presents test descriptions and analysis results for multiple, stress level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) ZP-1 wells: 299-W11-43 (C4694/Well H), 299-W15-50 (C4302/Well E), and 299-W18-16 (C4303/Well D). These wells are located within south-central region of the Hanford Site 200-West Area (Figure 1.1). The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OU ZP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.

54 ENVIRONMENTAL SCIENCES↗

Slug Test Characterization Results for Multi-Test/Depth Intervals Conducted During the Drilling of CERCLA Operable Unit OU UP-1 Wells 299-W19-48, 699-30-66, and 699-36-70B

This report presents test descriptions and analysis results for multiple, stress-level slug tests that were performed at selected test/depth intervals within three Operable Unit (OU) UP-1 wells: 299-W19-48 (C4300/Well K), 699-30-66 (C4298/Well R), and 699-36-70B (C4299/Well P). These wells are located within, adjacent to, and to the southeast of the Hanford Site 200-West Area. The test intervals were characterized as the individual boreholes were advanced to their final drill depths. The primary objective of the hydrologic tests was to provide information pertaining to the areal variability and vertical distribution of hydraulic conductivity with depth at these locations within the OU UP-1 area. This type of characterization information is important for predicting/simulating contaminant migration (i.e., numerical flow/transport modeling) and designing proper monitor well strategies for OU and Waste Management Area locations.

54 ENVIRONMENTAL SCIENCES↗

Utilizing multimodal high-intensity interval training for a firefighter training academy during the COVID-19 pandemic

Firefighters typically undergo a 16–24-week training academy during which they perform a variety of traditional exercise programs such as cardiovascular, resistance, and concurrent training. Because of limited facility access, some fire departments seek alternative exercise programs, such as multimodal high-intensity interval training (MM-HIIT), which essentially combines resistance and interval training. Here, the primary purpose of this study was to assess the effect of MM-HIIT on body composition and physical fitness in firefighter recruits who completed a training academy during the coronavirus (COVID-19) pandemic. A secondary purpose was to compare the effects of MM-HIIT to previous training academies that implemented traditional exercise programs. Healthy and recreationally-trained recruits (n=12) participated in 2-3 days/week of MM-HIIT for 12 weeks and had several components of body composition and physical fitness measured before and after the program. Because of COVID-19-related gym closures, all MM-HIIT sessions were performed outdoors at a fire station with minimal equipment. These data were retroactively compared to a control group (CG) that previously completed training academies with traditional exercise programs. Subjects in the MM-HIIT group significantly improved several components of body composition and fitness, including fat mass, fat-free mass, body fat percentage, aerobic capacity, and muscular endurance (p < 0.005). Moreover, there were no significant differences for any dependent variable when MM-HIIT was compared to the CG (p≥0.005). These results suggest that MM-HIIT may serve as an effective substitute for traditional concurrent training paradigms that are typically used for firefighter academies.

60 APPLIED LIFE SCIENCES↗

Microbial communities in the liver and brain are informative for postmortem submersion interval estimation in the late phase of decomposition: A study in mouse cadavers recovered from freshwater

Introduction Bodies recovered from water, especially in the late phase of decomposition, pose difficulties to the investigating authorities. Various methods have been proposed for postmortem submersion interval (PMSI) estimation and drowning identification, but some limitations remain. Many recent studies have proved the value of microbiota succession in viscera for postmortem interval estimation. Nevertheless, the visceral microbiota succession and its application for PMSI estimation and drowning identification require further investigation. Methods In the current study, mouse drowning and CO 2 asphyxia models were developed, and cadavers were immersed in freshwater for 0 to 14 days. Microbial communities in the liver and brain were characterized via 16S rDNA high-throughput sequencing. Results Only livers and brains collected from 5 to 14 days postmortem were qualified for sequencing. There was significant variation between microbiota from liver and brain. Differences in microbiota between the cadavers of mice that had drowned and those only subjected to postmortem submersion decreased over the PMSI. Significant successions in microbial communities were observed among the different subgroups within the late phase of the PMSI in livers and brains. Eighteen taxa in the liver which were mainly related to Clostridium_sensu_stricto and Aeromonas , and 26 taxa in the brain which were mainly belonged to Clostridium_sensu_stricto , Acetobacteroides , and Limnochorda , were selected as potential biomarkers for PMSI estimation based on a random forest algorithm. The PMSI estimation models established yielded accurate prediction results with mean absolute errors ± the standard error of 1.282 ± 0.189 d for the liver and 0.989 ± 0.237 d for the brain. Conclusions The present study provides novel information on visceral postmortem microbiota succession in corpses submerged in freshwater which sheds new light on PMSI estimation based on the liver and brain in forensic practice.

Wang, Linlin↗

Adaptive Framework for Maintenance Scheduling Based on Dynamic Preventive Intervals and Remaining Useful Life Estimation

Data-based prognostic methods exploit sensor data to forecast the remaining useful life (RUL) of industrial settings to optimize the scheduling of maintenance actions. However, implementing sensors may not be cost-effective or practical for all components. Traditional preventive approaches are not based on sensor data; however, they schedule maintenance at equally spaced intervals, which is not a cost-effective approach since the distribution of the time between failures changes with the degradation state of other parts or changes in working conditions. This study introduces a novel framework comprising two maintenance scheduling strategies. In the absence of sensor data, we propose a novel dynamic preventive policy that adjusts intervention intervals based on the most recent failure data. When sensor data are available, a method for RUL prediction, designated k-LSTM-GFT, is enhanced to dynamically account for RUL prediction uncertainty. The results demonstrate that dynamic preventive maintenance can yield cost reductions of up to 51.8% compared to conventional approaches. The predictive approach optimizes the exploitation of RUL, achieving costs that are only 3–5% higher than the minimum cost achievable while ensuring the safety of critical systems since all of the failures are avoided.

Nunes, Pedro (ORCID:0000000180012172)↗

EVALUATION OF SPRING OPERATED RELIEF VALVE MAINTENANCE INTERVALS AND EXTENSION OF MAINTENANCE TIMES USING A WEIBULL ANALYSIS WITH MODIFIED BAYESIAN UPDATING

The Savannah River Site (SRS) spring operated pressure relief valve (SORV) maintenance intervals were evaluated using an approach provided by the American Petroleum Institute (API RP 581) for risk-based inspection technology (RBI). In addition, the impact of extending the inspection schedule was evaluated using Monte Carlo Simulation (MCS). The API RP 581 approach is characterized as a Weibull analysis with modified Bayesian updating provided by SRS SORV proof testing experience. Initial Weibull parameter estimates were updated as per SRS's historical proof test records contained in the Center for Chemical Process Safety (CCPS) Process Equipment Reliability Database (PERD). The API RP 581 methodology was used to estimate the SORV's probability of failing on demand (PFD), and the annual expected risk. The API RP 581 methodology indicates that the current SRS maintenance plan is conservative. Cost savings may be attained in certain mild service applications that present low PFD and overall risk. Current practices are reviewed and recommendations are made for extending inspection intervals. The paper gives an illustration of the inspection costs versus the associated risks by using API RP 581 Risk Based Inspection (RBI) Technology. A cost effective maintenance frequency balancing both financial risk and inspection cost is demonstrated.

02 PETROLEUM↗

An Arbitrary Time Interval Generator Base on Vernier Clocks with 0.67 ps Adjustable Steps Implemented in FPGA

In TDC testing and timing system implementations, it is often necessary to generate signal pulses with finely adjustable time intervals. In delay cell–based schemes, the adjustment resolution is constrained by the propagation delay of the cells—typically 15–20 ps per step—and is sensitive to temperature and supply voltage variations. This document presents a fully digital approach that uses two vernier clocks, generated by two stages of cascaded phase-locked loops (PLLs) with a slight frequency difference, to achieve adjustable timing intervals through accumulated phase differences. The scheme was validated on two families of low-cost FPGA devices, achieving adjustable step sizes of 0.67 ps and 0.97 ps.

Wu, Jin-yuan [Fermilab] (ORCID:0000000344329521)↗

VALIDATION OF SPRING OPERATED PRESSURE RELIEF VALVE TIME TO FAILURE AND THE IMPORTANCE OF STATISTICALLY SUPPORTED MAINTENANCE INTERVALS

The Savannah River Site operates a Relief Valve Repair Shop certified by the National Board of Pressure Vessel Inspectors to NB-23, The National Board Inspection Code. Local maintenance forces perform inspection, testing, and repair of approximately 1200 spring-operated relief valves (SORV) each year as the valves are cycled in from the field. The Site now has over 7000 certified test records in the Computerized Maintenance Management System (CMMS); a summary of that data is presented in this paper. In previous papers, several statistical techniques were used to investigate failure on demand and failure rates including a quantal response method for predicting the failure probability as a function of time in service. The non-conservative failure mode for SORV is commonly termed 'stuck shut'; industry defined as the valve opening at greater than or equal to 1.5 times the cold set pressure. Actual time to failure is typically not known, only that failure occurred some time since the last proof test (censored data). This paper attempts to validate the assumptions underlying the statistical lifetime prediction results using Monte Carlo simulation. It employs an aging model for lift pressure as a function of set pressure, valve manufacturer, and a time-related aging effect. This paper attempts to answer two questions: (1) what is the predicted failure rate over the chosen maintenance/ inspection interval; and do we understand aging sufficient enough to estimate risk when basing proof test intervals on proof test results?

42 ENGINEERING↗

Time interval distributions of nuclear events in a digital spectrometer

This study compares the theoretical formula for time interval density distributions (TIDs) in counters with pileup rejection to TIDs measured using a digital spectrometer with trapezoid filtering. The TIDs were derived from successive time stamps of 60 Co and 133 Ba γ rays detected with a HPGe spectrometer. The results demonstrate that the theoretical formula is applicable up to 40% count loss and can be used to retrospectively deduce the incident event rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonparametric Prediction Intervals of Wind Power via Linear Programming

This letter proposes a machine learning-based linear programming model that quickly establishes the nonparametric prediction intervals of wind power by integrating extreme learning machine and quantile regression. The proportions of quantiles can be adaptively determined via sensitivity analysis. The proposed method has been proven to be significantly efficient and reliable, with a high application potential in power systems.

extreme learning machine↗

Modified Eigen-Decomposition-based Interval Analysis (MEDIA) for Power System Dynamic State Estimation

The Bayesian approach has been used for the dynamic state estimation (DSE) of a power system. However, due to the complexity of noise resources, it is difficult to quantify measurement and process noise using probability density functions (PDFs). To overcome the difficulty, the authors of this paper propose a modified eigen-decomposition-based interval analysis (MEDIA) method, which employs bounds instead of PDFs to quantify the noise, and uses the eigen decomposition method to reduce the negative impact of the overestimation problem. Using the simulation data generated from IEEE 16-machine and IEEE 10-machine systems, it is shown that the proposed MEDIA method can estimate the hard boundaries of dynamic states in real time. Furthermore, comparison with the forward-backward propagation method and the extended set-membership filter also shows that the proposed MEDIA method performs better by providing narrower boundaries in the DSE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technical Specification Surveillance Interval Extension of Digital Equipment in Nuclear Power Plants: Review and Research. Light Water Reactor Sustainability Program report

The nuclear industry has been slow to incorporate digital technology into nuclear plant designs for several reasons, including: The high cost of design change modifications to implement them, versus simply replacing them with like for like technology when the components fail; Digital technology qualification issues, particularly in safety related applications that are susceptible to software common cause failure. This is a concern both for current operating plants as well as new builds; and, General familiarity and comfort with the existing analog technology on the part of the nuclear plant engineering staff, in spite of the superior performance and reduced maintenance costs of the digital replacements. At the same time, the nuclear industry is under significant cost pressure in the electric marketplace due to the abundance of natural gas generation and renewables. The industry would benefit by investment in new technologies that could lower future operating costs while addressing obsolescence and reliability issues of the current analog technologies. However, the industry has been unable to formulate the business cases to take advantage of these labor savings and production reliability improvements. This paper discusses another potential cost savings benefit of a transition to digital technology, extending the surveillance intervals of technical specification required equipment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geyser eruption intervals and interactions: Examples from El Tatio, Atacama, Chile

Here, we compare and contrast data collected in 2012 and 2014 from the El Tatio geyser field, Chile. We identify geyser systems that evolve over time, including changes in the interval between eruptions, development of new thermal features, and interactions between geysers. We study three different cases: (a) an isolated geyser, which is periodic and has nearly identical eruptions every cycle; (b) a geyser and coupled noneruptive pool, where the geyser has nonregular cycles and several preplay eruptions before the main eruption; and (c) two geysers and a mud volcano, which have nonregular cycles and are all interacting. Though geysers erupt with different styles, we recognize some common features: the conduit recharges with liquid during the quiescent period, bubbles enter the conduit before eruptions, and eruptions occur when water boils in the upper part of the conduit. The episodic addition of heat may govern the periodicity, while the depth where heat is added dictates the eruption style: conduits with deeper heat input are more likely to show preplay or minor eruptions. The interactions between thermal features can be explained by pressure transmission in subsurface permeable layers between geyser conduits.

58 GEOSCIENCES↗