Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integrity attacks”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Discrete element modeling of indentation tests to investigate mechanisms of CO 2 -related chemomechanical rock alteration

During CO 2 injection into geological formations, petrophysical and geomechanical properties of host formations can be altered due to mineral dissolution and precipitation. Field and laboratory results have shown that sandstone and siltstone can be altered by CO 2 -water mixtures, but few quantitative studies have been performed to fully investigate underlying mechanisms. Based on the hypothesis that CO 2 -water mixtures alter the integrity of rock structure by attacking cements rather than grains, we attempt to explain the degradation of cementation due to long-term contact with CO 2 and water and mechanisms for changes in rock mechanical properties. Many sandstones, including calcite-cemented quartzitic sandstone, chlorite-cemented quartzitic sandstone, and hematite-cemented quartzitic sandstone, contain interparticle cements that are more readily affected by CO 2 -water mixtures than grains. A model that couples the discrete element method and the bonded-particle model is used to perform simulations of indentation tests on synthetic rocks with crystal and random packings. The model is verified against the analytical cavity expansion model and validated against laboratory indentation tests on Entrada sandstone with and without CO 2 alteration. Sensitivity analysis is performed for cementation microscopic parameters including stiffness, size, axial, and shear strength. The simulation results indicate that the CO 2 -related degradation of mechanical properties in bleached Entrada sandstone can be attributed to the reduction of cement size rather than cement strength. Finally, our study indicates that it is possible to describe the CO 2 -related rock alteration through particle-scale mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Omega-Limit Sets and Input-To-State Stability in Power Grids with Switching Equilibria

This paper studies a power transmission system with both conventional generators (CGs) and distributed energy assets (DEAs) providing frequency control. We consider an operating condition with demand aggregating two dynamic components: one that switches between different values on a finite set, and one that varies smoothly over time. Such dynamic operating conditions may result from protection scheme activations, external cyber-attacks, or due to the integration of dynamic loads, such as data centers. Mathematically, the dynamics of the resulting system are captured by a system that switches between a finite number of vector fields - or modes -, with each mode having a distinct equilibrium point induced by the demand aggregation. To analyze the stability properties of the resulting switching system, we leverage tools from hybrid dynamic inclusions and the concept of ..omega.. -limit sets from sets. Specifically, we characterize a compact set that is semi-globally practically asymptotically stable under the assumption that the switching frequency and load variation rate are sufficiently slow. For arbitrarily fast variations of the load, we use a level-set argument with multiple Lyapunov functions to establish input-to-state stability of a larger set and with respect to the rate of change of the loads. The theoretical results are illustrated via numerical simulations on the IEEE 39-bus test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Closed-Form Solution for Synchrophasor Data Correction under GPS Spoofing Attack

Phasor Measurement Units (PMUs) are increasingly being deployed to augment monitoring, protection and control applications in the power grid. PMUs rely on the Global Positioning System (GPS) for generation of time-synchronized and accurate measurements. However, civilian GPS signals, being unencrypted, are susceptible to GPS spoofing attacks (GSA). Hence ensuring the integrity of GPS-timing dependent synchrophasor data has become critical. In this paper, a closed-form analytical solution for estimating the GSA phase shift has been proposed and integrated to the spoofing detection & correction framework. Extensive simulations have been performed in order to verify the accuracy of the solution in determining the location and the phase shift of the compromised PMU. Time domain dynamic simulations presented in this paper demonstrate the applicability of the proposed solution for near-real-time detection of GSA, and this will enable faster detection and correction of phase angles of compromised synchrophasor data.

Synchrophasor, PMUs, GPS, Spoofing, Data Correctio↗

Blueprint: Open Worldwide Application Security Project Top 10 Common Weakness Enumerations for Electric Vehicle Supply Equipment

This report categorizes the top 10 security weaknesses in electric vehicle supply equipment (EVSE) using a similar approach by the Open Worldwide Application Security Project (OWASP) Top 10, and it describes example exploitations, methods for prevention, and related common weakness enumerations (CWEs) for each category. The weaknesses listed in this report could lead to security issues or vulnerabilities in EVSE if they are exploited by an attacker to compromise the confidentiality, integrity, or availability of a system. This report also recommends EVSE industry best practices and remediations for the identified weaknesses to use as guidelines for their secure products and systems.

33 ADVANCED PROPULSION SYSTEMS↗

Cdc13 N-Terminal Dimerization DNA Binding and Telomere Length Regulation

The essential yeast protein Cdc13 facilitates chromosome end replication by recruiting telomerase to telomeres, and together with its interacting partners Stn1 and Ten1, it protects chromosome ends from nucleolytic attack, thus contributing to genome integrity. Although Cdc13 has been studied extensively, the precise role of its N-terminal domain (Cdc13N) in telomere length regulation remains unclear. Here we present a structural, biochemical, and functional characterization of Cdc13N. The structure reveals that this domain comprises an oligonucleotide/oligosaccharide binding (OB) fold and is involved in Cdc13 dimerization. Biochemical data show that Cdc13N weakly binds long, single-stranded, telomeric DNA in a fashion that is directly dependent on domain oligomerization. When introduced into full-length Cdc13 in vivo, point mutations that prevented Cdc13N dimerization or DNA binding caused telomere shortening or lengthening, respectively. The multiple DNA binding domains and dimeric nature of Cdc13 offer unique insights into how it coordinates the recruitment and regulation of telomerase access to the telomeres.

59 BASIC BIOLOGICAL SCIENCES↗

Securing Smart Manufacturing: Detection of Cyber-Physical Attacks in CNC-Based Systems

As Industry 4.0 advances, the integration of computer numerical control (CNC) machines and advanced manufacturing technologies is transforming production into smart manufacturing systems that blend physical and digital processes as cyber-physical systems. However, this increased cyber-physical connectivity exposes manufacturing systems to cyber threats that can cause severe operational and financial disruptions. This paper presents a comparative study on cyber attacks and anomaly detection techniques in manufacturing, focusing on network traffic from CNC machines. The data extracted from network packets includes machine commands and control signals exchanged between the machine's interface and control system, crucial for maintaining operational integrity. We explore two types of cyber attacks, design modification and command injection, which pose substantial risks to CNC machine productivity and system integrity. Our investigation involves experiments on a real CNC system, highlighting the urgent need for effective detection mechanisms. To address these threats, we evaluate three anomaly detection methods: dynamic time warping (DTW), rolling average, and a deep learning, long short-term memory (LSTM) time-series-based autoencoder. Each is assessed for its effectiveness in identifying anomalous behaviors caused by the attacks. Our findings demonstrate the unique strengths and limitations of each detection technique, providing a deeper understanding of their applicability in realworld manufacturing environments. The comparative analysis indicates that while certain methods are highly effective against specific attack types, others offer broader applicability across different attacks. This study contributes to the accurate detection of anomalies in CNC machining processes, thereby enhancing the reliability and security of smart manufacturing systems against diverse cyber threats.

Williams, Bethanie [Tennessee Technological Univer↗

Cybersecurity Considerations for Hydrogen Infrastructure in Airport Environments

This report explores key cybersecurity concerns and best practices within environments that serve as reference points for the development of hydrogen fueling infrastructure for aviation. This cybersecurity analysis leverages prior NREL studies: 1) hydrogen fueling station component validation to identify vulnerabilities and failure events documented in physical equipment, and 2) electric aircraft charging infrastructure analysis to explore primary cybersecurity vulnerabilities. It reviews the criticality of digitized technologies in sustaining hydrogen fuel production, storage, and fueling systems, noting cybersecurity concerns that are universal to power systems and industrial control systems in general. In considering cybersecurity vulnerabilities within a future landscape of hydrogen energy for aviation applications, a reference architecture was intended to reveal the points of connection between assets and the potential sensors that are vulnerable to manipulation in the event of compromised access or communication within a SCADA system. A generalized reference architecture can help stakeholders, engineers, or strategists understand connections, criticalities, and standard practices when it comes to designing and planning for new systems. There are several gaps to account for in assessing the future of hydrogen production, storage, and fueling for aviation. Engaging stakeholders, including aircraft manufacturers, electric utilities, site property owners, and local communities, will inform decision-making around site structure, operations, and resources for future hydrogen fueling infrastructure to understand operational needs and cybersecurity awareness. Cybersecurity mitigation strategy must consider physical attack vectors that emerge with the integration of hydrogen systems into existing airport security requirements. The cybersecurity risk assessment contained in this report is an entry point into potential future granular-level analyses to be conducted as part of hazard and risk assessments for safe aviation hydrogen infrastructure, determining how the scale of hydrogen fuel infrastructure for aviation impacts the volume of cyber attack vectors, and what, if any, are the vulnerabilities associated with different types of on-board hydrogen systems. In this nascent development phase, assessing how best to integrate cybersecurity practices into an evolving U.S. aviation landscape provides critical insights into building increased awareness and stakeholder engagement to support a cyber-resilient infrastructure.

08 HYDROGEN↗

Integrated Cyber/Physical Grid Resiliency Modeling

This project explored coupling modeling and analysis methods from multiple domains to address complex hybrid (cyber and physical) attacks on mission critical infrastructure. Robust methods to integrate these complex systems are necessary to enable large trade-space exploration including dynamic and evolving cyber threats and mitigations. Reinforcement learning employing deep neural networks, as in the AlphaGo Zero solution, was used to identify "best" (or approximately optimal) resilience strategies for operation of a cyber/physical grid model. A prototype platform was developed and the machine learning (ML) algorithm was made to play itself in a game of 'Hurt the Grid'. This proof of concept shows that machine learning optimization can help us understand and control complex, multi-dimensional grid space. A simple, yet high-fidelity model proves that the data have spatial correlation which is necessary for any optimization or control. Our prototype analysis showed that the reinforcement learning successfully improved adversary and defender knowledge to manipulate the grid. When expanded to more representative models, this exact type of machine learning will inform grid operations and defense - supporting mitigation development to defend the grid from complex cyber attacks! This same research can be expanded to similar complex domains.

97 MATHEMATICS AND COMPUTING↗

ResDesign: Resilient by Design Platform for CPS Assessment and Validation

ResDesign project has developed integrated capabilities to help cyber physical system modelers and analysts to evaluate vulnerabilities and resilience of such systems using co-simulation-based attack testbed, graph-based visualization and monitoring tool, and Bayesian optimization-based co-design capability. The project demonstrates a collection of attack scenarios and use cases in an integrated software environment.

97 MATHEMATICS AND COMPUTING↗

STIDP: A US Department of Homeland Security program for countering explosives attacks at large public events and mass transit facilities

The Department of Homeland Security’s Standoff Technology Integration and Demonstration Program is designed to accelerate the development and integration of technologies, concepts of operations, and training to prevent explosives attacks at large public events and mass transit facilities. The program will address threats posed by suicide bombers, vehicle-borne improvised explosive devices, and leave-behind bombs. The program is focused on developing and testing explosives countermeasure architectures using commercial off-the-shelf and near-commercial standoff and remotely operated detection technologies in prototypic operational environments. An important part of the program is the integration of multiple technologies and systems to protect against a wider range of threats, improve countermeasure performance, increase the distance from the venue at which screening is conducted, and reduce staffing requirements. The program will routinely conduct tests in public venues involving successively more advanced technology, higher levels of system integration, and more complex scenarios. This paper describes the initial field test of an integrated countermeasure system that included infrared, millimeter-wave, and video analytics technologies for detecting person-borne improvised explosive devices at a public arena. The test results are being used to develop a concept for the next generation of integrated countermeasures, to refine technical and operational requirements for architectures and technologies, and engage industry and academia in solution development.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Cyber-attack detection and accommodation algorithm for energy delivery systems

Cyber-attack accommodation in a cyber-physical system is to ensure system operation, integrity and availability while maintaining a reasonable operational performance under attack. In this paper, we present a novel cyber-attack accommodation algorithm by estimating the true operational states of the system with new boundary & performance constrained resilient estimators while the system is continuously operating and is under attack. Our approach is based on combining data driven machine learning and physics based domain knowledge with traditional resilient estimation. The results were evaluated using a high fidelity model-based simulation environment.

97 MATHEMATICS AND COMPUTING↗

Using Discrete Event Simulation to Model Attacker Interactions with Cyber and Physical Security Systems

The number of connections between physical and cyber security systems is rapidly increasing due to centralized control from automated and remotely connected means. As the number of interfaces between systems continues to grow, the interactions and interdependencies between them cannot be ignored. Historically, physical and cyber vulnerability assessments have been performed independently. This independent evaluation omits important aspects of the integrated system, where the impacts resulting from malicious or opportunistic attacks are not easily known or understood. Here, we describe a discrete event simulation model that uses information about integrated physical and cyber security systems, attacker characteristics and simple response rules to identify key safeguards that limit an attacker's likelihood of success. Key features of the proposed model include comprehensive data generation to support a variety of sophisticated analyses, and full parameterization of safeguard performance characteristics and attacker behaviours to evaluate a range of scenarios. Lastly, we also describe the core data requirements and the network of networks that serves as the underlying simulation structure.

97 MATHEMATICS AND COMPUTING↗

Detection of False Data Injection Attacks in Battery Stacks Using Input Noise-Aware Nonlinear State Estimation and Cumulative Sum Algorithms

Grid-scale battery energy storage systems (BESSs) are vulnerable to false data injection attacks (FDIAs), which could be used to disrupt state of charge (SoC) estimation. Inaccurate SoC estimation has negative impacts on system availability, reliability, safety, and the cost of operation. In this article a combination of a Cumulative Sum (CUSUM) algorithm and an improved input noise-aware extended Kalman filter (INAEKF) is proposed for the detection and identification of FDIAs in the voltage and current sensors of a battery stack. The series-connected stack is represented by equivalent circuit models, the SoC is modeled with a charge reservoir model and the states are estimated using the INAEKF. Further, the root mean squared error of the states’ estimation by the modified INAEKF was found to be superior to the traditional EKF. By employing the INAEKF, this article addresses the research gap that many state estimators make asymmetrical assumptions about the noise corrupting the system. Additionally, the INAEKF estimates the input allowing for the identification of FDIA, which many alternative methods are unable to achieve. The proposed algorithm was able to detect attacks in the voltage and current sensors in 99.16% of test cases, with no false positives. Utilizing the INAEKF compared to the standard EKF allowed for the identification of FDIA in the input of the system in 98.43% of test cases.

25 ENERGY STORAGE↗

Secure Information Exchange Gateway for Electric Grid Operations

The major objectives of the SIEGate project were to improve the security posture and minimize the cyber-attack surface of electric utility control centers and to reduce the cost of maintaining control-room-to-control-room information exchange. Major project goals included the design, development, testing, and commercialization of a single security-hardened appliance that could meet industry needs for resisting cyber-attacks while protecting the confidentiality and integrity of a growing volume of real-time information needed to ensure the reliability of the bulk electric system and interoperating with existing data formats and networking technologies. The SIEGate project has achieved its goals and objectives. The SIEGate Design Document, issued in March 2012, presented SIEGate use cases, provided SIEGate requirements, established SIEGate design principles, and prescribed design functionality of SIEGate as well as the components that make up SIEGate. SIEGate Release Version 1.0 was posted in January 2014. Release Version 1.0.83, which was posted on March 28, 2014, fixed many issues discovered by early adopters and added several new features. Release Candidate 1.1, which added additional improvements and bug fixes, was posted in June 2014. SIEGate executables have been downloaded more than 300 times. SIEGate has been tested at PJM, Entergy, TVA, and Southern. Security testing and analysis of SIEGate has been conducted at PNNL and PJM. Alstom has provided a summary of recommended steps for commercialization of the SIEGate Appliance and identified two deployment models with immediate commercial application.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cyber Security Primer for DER Vendors Aggregators and Grid Operators

This report provides an introduction to cyber security for distributed energy resources (DER) - such as photovoltaic (PV) inverters and energy storage systems (ESS). This material is motivated by the need to assist DER vendors, aggregators, grid operators, and broader PV industry with cyber security resilience and describe the state-of-the-art for securing DER communications. The report outlines basic principles of cyber security, encryption, communication protocols, DER cyber security recommendations and requirements, and device-, aggregator-, and utility-level security best practices to ensure data confidentiality, integrity, and availability. Example cyber security attacks, including eavesdropping, masquerading, man-in-the-middle, replay attacks, and denial-of-service are also described. A survey of communication protocols and cyber security recommendations used by the DER and power system industry are included to elucidate the cyber security standards landscape. Lastly, a roadmap is presented to harden end-to-end communications for DER with research and industry engagement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Integrated Safety and Security Models for Comprehensive Reliability and Resiliency Evaluation

The security of the electric grid and supporting energy systems is crucial to national security. One of the complexities in analyzing the security of energy systems is the safety consequences that may result from accidents. For energy systems, the goal is to ensure that they operate as intended and that any consequences are mitigated or prevented. The integration of safety and security is paramount to protecting these systems from attacks and ensuring that large consequences are prevented. This report describes an integrated safety and security methodology to evaluate cybersecurity events that can lead to large consequences. This novel approach first describes how Systems-Theoretic Process Analysis (STPA) provides a digital causal analysis for Bayesian Networks (BNs). The use of STPA causal analysis provides a systematic approach to constructing BNs that adequately model cyber scenarios that result in consequences. When combined with the technical principles described in Risk-Informed Management of Enterprise Systems (RIMES), a comprehensive risk-informed cybersecurity analysis results that allows decision-makers to prioritize systems that most impact risk.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Methodology and Application of Physical Security Effectiveness Based on Dynamic Force-on-Force Modeling

This report describes the research and development being performed at INL towards a dynamic modeling and simulation framework to enable physical security optimization at commercial nuclear power plants. The framework is based on the dynamic modeling tool EMRALD and is demonstrated for applications that can result in physical security optimization. Two main applications are presented: 1. Integrating FLEX portable equipment performance with FOF models of a plant’s physical security posture, and 2. Location optimization of bullet resistant enclosure. The generic framework for modeling FLEX portable equipment is described in detail, followed by a case study modeling an adversarial attack aimed at causing a radiological release by sabotaging the plant’s power supply and its ultimate heat sink capabilities at a hypothetical PWR. Two distinct FLEX deployment strategies, series and parallel, are modeled with distinct timelines. The results of the adversarial attack modeled in a commercial FOF tool, AVERT, are integrated with the FLEX deployment model in EMRALD. Monte Carlo simulation is used to model the distribution of the timeline in FLEX deployment strategies. Thermal-hydraulic analysis of FLEX performance is performed in RELAP5 and integrated with the EMRALD simulations to provide more realistic timelines in the models. The results demonstrate that, even in the extreme case of a successful adversarial attack, deployment of FLEX equipment can result in a significantly high likelihood of preventing radiological release. The modeling and simulation framework of integrating FLEX equipment with FOF models enables the NPPs to credit FLEX portable equipment in the plant security posture, resulting in an efficient and optimized physical security. The objective of location optimization of BRE is to determine the best location in the plant for a new BRE being planned by the plant to enhance their physical security effectiveness. The plant physical security FOF model is integrated with EMRALD that performs Monte Carlo simulation to run different attack scenarios and a discrete set of potential BRE locations. Sensitivity analysis is used to determine the most effective location for the BRE. The optimization approach can be extended to wide applications such as location optimization of remotely operated weapons and other strategic fixed assets.

97 MATHEMATICS AND COMPUTING↗

Cyber/Physical Security Vulnerability Assessment Integration

Securing high value and critical assets is one of the biggest challenges facing this nation and others around the world. In modern integrated systems, there are four potential modes of attack available to an adversary: • physical only attack, • cyber only attack, • physical-enabled cyber attack, • cyber-enabled physical attack. Blended attacks involve an adversary working in one domain to reduce system effectiveness in another domain. This enables the attacker to penetrate further into the overall layered defenses. Existing vulnerability assessment (VA) processes and software tools which predict facility vulnerabilities typically evaluate the physical and cyber domains separately. Vulnerabilities which result from the integration of cyber-physical control systems are not well characterized and are often overlooked by existing assessment approaches. In this paper, we modified modification of the timely detection methodology, used for decades in physical security VAs, to include cyber components. The Physical and Cyber Risk Analysis Tool (PACRAT) prototype illustrates an integrated vulnerability assessment that includes cyber-physical interdependencies. Information about facility layout, network topology, and emplaced safeguards is used to evaluate how well suited a facility is to detect, delay, and respond to attacks, to identify the pathways most vulnerable to attack, and to evaluate how often safeguards are compromised for a given threat or adversary type. We have tested the PACRAT prototype on critical infrastructure facilities and the results are promising. Future work includes extending the model to prescribe the recommended security improvements via an automated cost-benefit analysis.

MacDonald, Douglas G.↗