Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “instrumental resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Pan-sharpening for microscopy

Techniques for generating full-spatial resolution, full spectral resolution image(s) from a 3D spectral-data cube for any spectral value within a given spectral range are provided without requiring the acquisition of all full-spatial resolution, full spectral resolution data by an instrument. The 3D spectral-data cube is generated from a limited number of full-spatial resolution, sparse spectral resolution data and a sparse-spatial resolution, full-spectral resolution data of the same area of the sample. The use of the 3D spectral-data cube reduces the data acquisition time.

Ovchinnikova, Olga S.↗

Nanoscale Three-Dimensional Imaging of Integrated Circuits Using a Scanning Electron Microscope and Transition-Edge Sensor Spectrometer

X-ray nanotomography is a powerful tool for the characterization of nanoscale materials and structures, but it is difficult to implement due to the competing requirements of X-ray flux and spot size. Due to this constraint, state-of-the-art nanotomography is predominantly performed at large synchrotron facilities. We present a laboratory-scale nanotomography instrument that achieves nanoscale spatial resolution while addressing the limitations of conventional tomography tools. The instrument combines the electron beam of a scanning electron microscope (SEM) with the precise, broadband X-ray detection of a superconducting transition-edge sensor (TES) microcalorimeter. The electron beam generates a highly focused X-ray spot on a metal target held micrometers away from the sample of interest, while the TES spectrometer isolates target photons with a high signal-to-noise ratio. This combination of a focused X-ray spot, energy-resolved X-ray detection, and unique system geometry enables nanoscale, element-specific X-ray imaging in a compact footprint. The proof of concept for this approach to X-ray nanotomography is demonstrated by imaging 160 nm features in three dimensions in six layers of a Cu-SiO 2 integrated circuit, and a path toward finer resolution and enhanced imaging capabilities is discussed.

47 OTHER INSTRUMENTATION↗

EPCAPE-PT-LANL Measurements: Proton Transfer Reaction Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: IONICON High-Resolution PTR-TOF-MS - Trace VOC Analyzer. Concentrations were calculated based on theoretical reaction rates of each species with H3O+. Details of the calculation are found in the PTR-MS Ionicon Manual. Data Notes: It is a high-resolution PTR-TOF-MS we have sub-selected relevant species. Contact us if you want additional data products from this instrument. Header: - CalculatedAcetonitrile[ppbv]: The concentration of acetonitrile expressed in parts per billion by volume (ppbv). - CalculatedAcetaldehyde[ppbv]: The concentration of acetaldehyde expressed in parts per billion by volume (ppbv). - CalculatedAcetone[ppbv]: The concentration of acetone expressed in parts per billion by volume (ppbv). - CalculatedAceticAcid[ppbv]: The concentration of acetic acid expressed in parts per billion by volume (ppbv). - CalculatedIsoprene[ppbv]: The concentration of isoprene expressed in parts per billion by volume (ppbv). - CalculatedMVK[ppbv]: The concentration of methyl vinyl ketone (MVK) and methacrolein (MACR) expressed in parts per billion by volume (ppbv). - CalculatedMEK[ppbv]: The concentration of methyl ethyl ketone (MEK) expressed in parts per billion by volume (ppbv). - CalculatedBenzene[ppbv]: The concentration of benzene expressed in parts per billion by volume (ppbv). - CalculatedToluene[ppbv]: The concentration of toluene expressed in parts per billion by volume (ppbv).

54 ENVIRONMENTAL SCIENCES↗

Generating high-resolution total canopy SIF emission from TROPOMI data: Algorithm and application

Solar-induced chlorophyll fluorescence (SIF) is a rapidly advancing front in modeling global terrestrial gross primary production (GPP). Canopy total SIF emissions (SIF total ) are mechanistically linked to the plant photosynthesis, and can be estimated from satellite observed SIF (SIF obs ) through radiative transfer modeling. However, the current satellite SIF obs and thus SIF total are available only at coarse spatial resolutions from several kilometers to tens of kilometers, inhibiting the application at fine spatial scales. Here, in this work, we proposed an algorithm to generate both global high-resolution SIF total (HSIF total ) and high-resolution SIF obs (HSIF obs ) at 1 km from low-resolution SIF obs (LSIF obs ) from the TROPOspheric Monitoring Instrument (TROPOMI), which has a spatial resolution at nadir of 3.5 km by 5.6–7 km. Our statistical method is based on the law of energy conservation and uses satellite derived fraction of absorbed photosynthetically active radiation, fluorescence efficiency, and the escape probability of fluorescence. We evaluated the accuracy of our HSIF total using the Orbiting Carbon Observatory-2 SIF (R 2 = 0.78). We found that the spatial resolution had clear effects on the relationship between HSIF total and GPP. We also compared HSIF total to 8-day averaged tower GPP from 135 flux sites and found that they were better correlated when HSIF total was averaged over a 1-km radius around the tower than when averaged over a larger radius. Our study provided a unique high-resolution HSIF total product, which will advance the estimation of GPP by extrapolating site-level relationships to the global scale.

54 ENVIRONMENTAL SCIENCES↗

SOFIA: Spectrometer Optimized for Facility Integrated Applications

Los Alamos National Laboratory researchers developed the Spectrometer Optimized for Facility Integrated Applications (SOFIA) for new capabilities in non-destructive nuclear material analysis, nuclear data measurements, and actinide science. SOFIA is the first ultra-high resolution gamma spectrometer technology based on low-temperature microcalorimeter designs. By precisely measuring the gamma rays passively emitted from radioactive and nuclear materials, SOFIA provides rapid, completely nondestructive analysis to improve the economics and timeliness of nuclear material analysis by reducing reliance on costly sampling and destructive analysis. By developing the first compact instrument based on ultrahigh resolution microcalorimeter gamma spectroscopy, the researchers intended to bring this technology into practical use in nuclear facilities and analytical laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution electron time-of-flight spectrometers for angle-resolved measurements at the SQS Instrument at the European XFEL

A set of electron time-of-flight spectrometers for high-resolution angle-resolved spectroscopy was developed for the Small Quantum Systems (SQS) instrument at the SASE3 soft X-ray branch of the European XFEL. The resolving power of this spectrometer design is demonstrated to exceed 10 000 (E/ΔE), using the well known Ne 1s –1 3p resonant Auger spectrum measured at a photon energy of 867.11 eV at a third-generation synchrotron radiation source. At the European XFEL, a width of ~0.5 eV full width at half-maximum for a kinetic energy of 800 eV was demonstrated. It is expected that this linewidth can be reached over a broad range of kinetic energies. An array of these spectrometers, with different angular orientations, is tailored for the Atomic-like Quantum Systems endstation for high-resolution angle-resolved spectroscopy of gaseous samples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft X-ray reflection ptychography

Scanning transmission X-ray microscopy and ptychography have become mature tools for high-resolution, element-specific imaging of nanoscale structures. However, transmission geometries impose stringent constraints on sample thickness and preparation, thereby limiting investigations of extended or bulk specimens, especially in the soft X-ray region. Here, we demonstrate reflection-geometry soft X-ray ptychography as a robust imaging mode. Instrumental feasibility and spatial resolution are established using a lithographically defined Siemens star and barcode test pattern on a multilayer substrate. We empirically demonstrate a full-pitch spatial resolution of ca. 45 nm from Fourier ring correlation analysis of the reconstructed object. The results highlight the potential of the reflection geometry for nondestructive X-ray studies of materials without the need for transmissive samples.

Guenzing, Damian [Lawrence Berkeley National Labor↗

GTC Follow-up Observations of Very Metal-poor Star Candidates from DESI

Abstract The observations from the Dark Energy Spectroscopic Instrument (DESI) will significantly increase the numbers of known extremely metal-poor stars by a factor of ∼10, improving the sample statistics to study the early chemical evolution of the Milky Way and the nature of the first stars. In this paper we report follow-up observations with high signal-to-noise ratio of nine metal-poor stars identified during the DESI commissioning with the Optical System for Imaging and Low-Resolution Integrated Spectroscopy (OSIRIS) instrument on the 10.4 m Gran Telescopio Canarias. The analysis of the data using a well-vetted methodology confirms the quality of the DESI spectra and the performance of the pipelines developed for the data reduction and analysis of DESI data.

79 ASTRONOMY AND ASTROPHYSICS↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Visible-to-THz near-field nanoscopy

Optical microscopy has a key role in research, development and quality control across a wide range of scientific, technological and medical fields. However, diffraction limits the spatial resolution of conventional optical instruments to about half the illumination wavelength. A technique that surpasses the diffraction limit in the wide spectral range between visible and terahertz frequencies is scattering-type scanning near-field optical microscopy (s-SNOM). The basis of s-SNOM is an atomic force microscope in which the tip is illuminated with light from the visible to the terahertz spectral range. By recording the elastically tip-scattered light while scanning the sample below the tip, s-SNOM yields near-field optical images with a remarkable resolution of 10 nm, simultaneously with the standard atomic force microscopic topography image. This resolution is independent of the illumination wavelength, rendering s-SNOM a versatile nanoimaging and nanospectroscopy technique for fundamental and applied studies of materials, structures and phenomena. This Review presents an overview of the fundamental principles governing the measurement and interpretation of near-field contrasts and discusses key applications of s-SNOM. We also showcase emerging developments that enable s-SNOM to operate under various environmental conditions, including cryogenic temperatures, electric and magnetic fields, electrical currents, strain and liquid environments. Furthermore, all these recent developments broaden the applicability of s-SNOMs for exploring fundamental solid-state and quantum phenomena, biological matter, catalytic reactions and more.

Hillenbrand, Rainer [CIC nanoGUNE BRTA and Departm↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

Enabling Ultralow Volume Analysis with a High-Resolution Ion Mobility Mass Spectrometry Platform

Of all the molecules thought to exist in the universe, it is estimated that researchers only know the chemical structures of 5% of them. Identifying the chemical structures of the remaining 95% has proven extremely challenging because many molecules exhibit low abundance, are contained in small volumes (e.g., <10 nL), do not readily ionize, exhibit similar structures to other molecules, etc. No single analytical technique exists to definitively identify the structure of an unknown molecule, and thus multiple different molecular measurements are typically made (i.e., multi-modal approach). Ion mobility (IMS) and mass spectrometry (MS) are two key tools that researchers use to determine the chemical structures of unknown molecules, and recently high-resolution and ultrahigh resolution IMS-MS instruments have provided greater confidence than ever before. However, HR-IMS-MS instruments typically exhibit low ion utilization efficiency, meaning they require large amounts of sample for an analysis (e.g., >10 µL). Unfortunately, this limitation prohibits the analysis of small volume samples where many unknown molecules exist. Described herein are the efforts made to enable the analysis of ultralow volumes with an HR-IMS-MS platform. A new scanning technique, termed a ‘stuttered traveling wave scan’, was developed as a replacement for the dual-gated scanning technique and works by halting the traveling waves after allowing ions to separate and then repeatedly restarting and stopping the traveling waves to incrementally move ions from the SLIM to the Orbitrap. Ions were stored inside the SLIM while the TWs were stopped, allowing the Orbitrap to perform high-resolution mass analysis. When the Orbitrap was ready, the TWs were restarted for short periods of time (<10 ms) to move ions from the SLIM to the Orbitrap. It was discovered that lower TW amplitudes and speeds than used during IMS separation were required to produce IMS peaks with the highest signal intensities and best resolving powers. The stuttered TW scan was found to produce similar resolutions and signal intensities compared to the dual-gated scanning technique. A new IMS design possessing an intersecting ‘tee’ with a reversible traveling wave was also developed to improve ion utilization efficiency during cyclic operation, which is necessary when only a single IMS spectrum can be acquired, such as when analyzing ultralow volume samples. The new capabilities described in this report lay the groundwork for acquiring HR-IMS-MS spectra of ultralow volume biological samples, such as single cells, where HR-IMS-MS can help elucidate the structures of unknown compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Intra-annual variations of regional total column ozone, aerosol optical depth, and water vapor from ground-based, satellite-based and model-based observations

The Microtops II ozonometer has been deployed to continuously measure the total column ozone (TCO), pre-cipitable water content (PWC) and aerosol optical thickness (AOT) at Atigre village (16.74° N, 74.37° E, 604 m above sea level, masl) located on the southeastern slope of Indian western Ghats. The Microtops II ozonometer measurements during the period from September 2017 to June 2018 were analyzed along with the retrieved products of Ozone Monitoring Instrument (OMI) and Moderate Resolution Imaging Spectroradiometer (MODIS) onboard NASA's Terra satellites and also the ERA-interim reanalysis model. We found that the TCO (or PWC) data from the OMI (or MODIS) and the ERA reanalysis model data products are in good agreement. The mea-surements showed strong seasonal variability such that TCO was lowest in the winter season but increased in the summer season, and both PWC and AOT were lowest in the post-monsoon season and increased in the summer season. In continuous ERA-interim reanalysis TCO observations, we found the three types of periodicities in the daily mean TCO as well as PWC (i) The weekly (7 days), (ii) quasi-biweekly (14 to 16 days), (iii) Madden Julian Oscillations (MJO) (30–60 days) oscillations. These oscillations depend on the periodic weather changes in the troposphere. We also observe that the average day to day variability in daily mean TCO observations in the observational period is about 1.4%, 1.1%, 2.62% in the Microtops II ozonometer, ERA-interim reanalysis, and OMI data respectively. We found the positive correlation between daily mean AOT and PWC in all seasons (except monsoon), which is maximum in the winter season, showing the hygroscopic nature of aerosols. The sources of water vapor and aerosol at our location are also studied using back-trajectory analysis.

Nade, Dada R.↗

A liquid hydrogen tube moderator arrangement for SNS second target station

Liquid hydrogen filled tubes arranged in a triangular shape surrounded by light-water premoderators were investigated as cold moderators coupled to a neutron production zone of a tungsten target fed by a 1.3 GeV proton beam in a short-pulse mode. A moderator concept optimized for the tube length, premoderator thickness, and target position was found to deliver the highest pulse-integrated neutron brightness suitable to send cold neutron beams for neutron scattering instrumentation geared toward medium resolution and small samples. Reducing the tube diameter from 50 to 10 mm boosts the cold neutron brightness (E < 10 meV) by a factor of 2.25, also with enhancements seen by downsizing the height of cylindrical moderators in earlier studies. Attempts were made to characterize this novel moderator system with regard to pulse shapes, local brightness distribution, and angular distribution of emission at the neutron emission port.

Gallmeier, Franz X. (ORCID:0000000171500764)↗

Sub-nanosecond time-resolved radiation measurement using x-ray focusing crystal spectrometers

Here, in this paper, we describe a technique using a crystal spectrometer, a silicon-diode detector, and a filtered photoconductive detector to monitor photon energies in the L-shell (0.9–1 keV) and K-shell regimes for nickel and copper hybrid X-pinch x-ray sources. The detectors, system cabling, and an 8 GHz digital oscilloscope in combination enable time resolution better than 200 ps for photoconductive detectors and 700 ps for silicon-diode detectors of the K- and L-shell radiation signals, respectively. We substantially improve the relative timing of signals obtained using the oscilloscope by using an x-ray streak camera with a crystal spectrometer to monitor the L-shell line spectra and, separately, the K-shell line spectra relative to the continuum burst to better than 17 ps time resolution. This combination of instruments enabled and validated a new method by which plasma conditions in nickel and copper X-pinches can be assessed immediately before and after the ~30 ps continuum x-ray burst produced by 370 kA hybrid X-pinches. In general, the method described here can be applied to observe otherwise highly filter-absorbed radiation in the presence of a broad spectrum of higher energy radiation by combining x-ray crystals and detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interstate-24 MOTION: Closing the Loop on Smart Mobility

We introduce the I-24 Mobility Technology Interstate Observation Network (MOTION), a transportation cyber-physical systems testbed under development in Tennessee. It consists of a six-mile freeway segment instrumented with 400 4K resolution cameras, processed by a real-time compute system to enable continuous performance monitoring of freeway traffic. The testbed is being developed to support next generation connected and autonomous vehicle technologies and advanced traffic management. When complete, the testbed will be the longest continuously observed freeway segment in the world. This article introduces the testbed, discusses the core design choices, and outlines the preliminary work conducted to support the design.

Gloudemans, Derek↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗