Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Commissioning of the large-scale lead tungstate scintillating calorimeter

Here, we report on the installation and initial commissioning of a large-scale lead tungstate (PbWO4) scintillating crystal calorimeter developed for high-rate photon detection and precise energy measurement. The calorimeter comprises 1596 high-granularity, high-resolution scintillating crystals optimized for electromagnetic-shower detection over a wide energy range. Scintillation light from each crystal is read out by Hamamatsu R4125 photomultiplier tubes equipped with a custom voltage divider and front-end amplifier to ensure stable gain at high rates. All calorimeter modules were fabricated and characterized using a light-emitting diode–based optical test system prior to installation to verify uniformity and photodetector performance. After installation, the electromagnetic calorimeter was fully integrated into the experiment data acquisition and energy-based trigger systems. The optical response of the modules was equalized using the light-monitoring system, cosmic-ray muons, and photons from Compton-scattering events. Commissioning results demonstrate a reliably calibrated optical response and stable detector performance during the first run. These results validate the calorimeter design and commissioning methodology for large-scale scintillator-based photonic instrumentation.

Analog to digital converters↗

Historical Pattern Analysis of Global Geothermal Power Capacity Development: Preprint

Between 1913 and 1958, Italy was the only country with an operational geothermal power plant until New Zealand installed its first plant in 1958. At present, 24 countries are involved in the geothermal power market, and they have a combined installed capacity of 16,127 GW. This study analyzes the historical patterns of geothermal power capacity in the world and in individual countries to investigate the ideal global geothermal development pattern by examining the annual cumulative capacity (ACC) and the annual capacity addition (ACA) graphs of the historical development of geothermal power capacity in 24 countries. First, the global patterns are analyzed using these graphs in five periods (1945-1957, 1958-1976, 1977-1991, 1992-2002, and 2003-2020) that are marked by a series of characteristics of ACA peaks separated by two major troughs. Then, five characteristic patterns are developed in five periods globally. These patterns correspond to the early-stage linear, the first acceleration, the first steady-state linear, the second acceleration, and the second steady-state linear developments. A positive relationship exists between global patterns and the 5-year shifted oil-price curve: two major factors influenced global development: 1) increasing oil prices and increasing awareness of global climate change, and 2) global development of geothermal power. Last, we investigate these patterns in each country. The top ten countries, which comprise 93.3% of the world's total installed capacity are separated into five groups based on the availability and characteristics of patterns globally developed in five periods. Group-1 (the United States) has an installed capacity of 3,794 MW, Group-2 (Mexico and Philippines) 963-1935 MW, Group-3 (New Zealand, Italy, Iceland, and Japan) 601-1,037 MW, and Group-4 (Indonesia, Kenya, and Turkiye) 944-2,356 MW. The remaining 14 countries (6.7%), which are called Group 5, are still in an immature stage and have installed capacities of 7-262 MW and are not involved in pattern analysis. Overall, geothermal power in the world is in its third stage of development, which had its peak development after 1977. A fourth development peak may be expected to occur after this through business-as-usual cases. The biggest barrier to the development of the global geothermal power market is the risk associated with exploration and drilling. If risk mitigation systems and funds are employed, the growth of geothermal power production projects could accelerate.

GEOTHERMAL ENERGY↗

Historical Pattern Analysis of Global Geothermal Power Capacity Development

Between 1913 and 1958, Italy was the only country with an operational geothermal power plant until New Zealand installed its first plant in 1958. At present, 24 countries are involved in the geothermal power market, and they have a combined installed capacity of 16,127 GW. This study analyzes the historical patterns of geothermal power capacity in the world and in individual countries to investigate the ideal global geothermal development pattern by examining the annual cumulative capacity (ACC) and the annual capacity addition (ACA) graphs of the historical development of geothermal power capacity in 24 countries. First, the global patterns are analyzed using these graphs in five periods (1945-1957, 1958-1976, 1977-1991, 1992-2002, and 2003-2020) that are marked by a series of characteristics of ACA peaks separated by two major troughs. Then, five characteristic patterns are developed in five periods globally. These patterns correspond to the early-stage linear, the first acceleration, the first steady-state linear, the second acceleration, and the second steady-state linear developments. A positive relationship exists between global patterns and the 5-year shifted oil-price curve: two major factors influenced global development: 1) increasing oil prices and increasing awareness of global climate change, and 2) global development of geothermal power. Last, we investigate these patterns in each country. The top ten countries, which comprise 93.3% of the world's total installed capacity are separated into five groups based on the availability and characteristics of patterns globally developed in five periods. Group-1 (the United States) has an installed capacity of 3,794 MW, Group-2 (Mexico and Philippines) 963-1935 MW, Group-3 (New Zealand, Italy, Iceland, and Japan) 601-1,037 MW, and Group-4 (Indonesia, Kenya, and Turkiye) 944-2,356 MW. The remaining 14 countries (6.7%), which are called Group 5, are still in an immature stage and have installed capacities of 7-262 MW and are not involved in pattern analysis. Overall, geothermal power in the world is in its third stage of development, which had its peak development after 1977. A fourth development peak may be expected to occur after this through business-as-usual cases. The biggest barrier to the development of the global geothermal power market is the risk associated with exploration and drilling. If risk mitigation systems and funds are employed, the growth of geothermal power production projects could accelerate.

GEOTHERMAL ENERGY↗

Exploring Social Dynamics of Hard-Disk Drives Circularity with an Agent-Based Approach

By 2025, it is estimated that installed data storage in the U.S. will be 2.2 Zettabytes, generating about 50 million units of end-of-life hard-disk drives (HDDs) per year. The circular economy (CE) tackles waste issues by maximizing value retention in the economy, for instance, through reuse and recycling. However, the reuse of hard disk drives is hindered by the lack of trust organizations have toward other means of data removal than physically destroying HDDs. Here, an agent-based approach explores how organizations' decisions to adopt other data removal means affect HDDs' circularity. The model applies the theory of planned behavior to model the decisions of HDDs end-users. Results demonstrate that the attitude (which is affected by trust) of end-users toward data-wiping technologies acts as a barrier to reuse. Moreover, social pressure can play a significant role as organizations that adopt CE behaviors can set an example for others.

28 EE - Advanced Manufacturing Office (EE-5A)↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

Installation Quality Framework: Investment Return Approach for Energy Savings on Building Product Installation

A case study was conducted on 44 residential homes using both traditional house wrap and ZIP System systems to measure the overall airtightness and compare estimated energy usages. The labor, material, and overhead and profit (O&P) costs were analyzed and used to determine the optimal choice for long-term benefits in terms of cost and performance. The impact of insulation installation is considered a key factor in improving the strategy of reducing energy consumption. Improved installation practices can affect the airtightness of common wall assemblies to reduce the building energy performance gaps and provide insight on how to allocate resources better. A framework was developed to analyze operational costs and building energy performance to address how installation quality is a factor in the return of investment in building construction for heating and cooling systems within the thermal envelope. With this methodology, aggressive energy performance goals will be met while balancing the tradeoff between installation techniques and building systems efficiency based on the introduced probabilistic investment return (PIR) metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseload Hydrogen Production Using Nuclear and Renewable Energy: A Comparative Analysis

As the global push towards net zero carbon gains momentum, the demand for clean hydrogen is expected to grow rapidly across various sectors, including transportation, industries and electrical grids. To meet this growing hydrogen demand, baseload hydrogen production facilities capable of providing a continuous and reliable supply of hydrogen will be necessary throughout the world. This paper explores the technoeconomic feasibility of establishing baseload electrolytic hydrogen production facilities in the United States, utilizing different clean generation resources. The key criteria include maintaining a consistent supply of clean hydrogen without putting baseload demand stress to already vulnerable power grid. In order to do that, the proposed facilities will host onsite clean power generation and energy storage technologies. The proposed facilities can capitalize on available investment and production incentives and have ability to export excess electricity to the utility at a bulk price. Several scenarios are considered based on the clean energy resources to support the electrolysis process including light water reactors (LWRs) currently evaluating retirement options, wind, solar PVs, and advanced small modular reactors (SMRs). For each scenario, a hypothetical hydrogen production facility is considered in a location in the US where the primary generation resource is at its peak strength. Comparative analysis in this paper reveal that the nuclear power plants are most economically viable for baseload hydrogen production facilities, outperforming renewable-based facilities with significantly lower levelized cost of hydrogen (LCOH). Even under best-case scenarios for resource availability, incentives and export prices, renewable-based facilities face challenges due to daily and seasonal generation variability, resulting in large installation sizes and lower capacity factors. Among renewable-based facilities, complementarity hybrids, providing more stable power supply, demonstrate superior economics compared to facilities based on a single renewable technology. While LWR-powered facility can achieve a negative LCOH with incentives, SMR-powered facilities can provide economic hydrogen supply with LCOH below $1/kg with high temperature electrolysis option. The analysis in this paper underscores the pivotal role of nuclear energy in the future hydrogen economy.

08 - HYDROGEN↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks, With Minimum Sustainable Price Analysis: Q1 2023

The U.S. Department of Energy's (DOE's) Solar Energy Technologies Office (SETO) aims to accelerate the advancement and deployment of solar technology in support of an equitable transition to a decarbonized economy no later than 2050, starting with a decarbonized power sector by 2035. Its approach to achieving this goal includes driving innovations in technology, hardware, and soft cost reductions to make solar affordable and accessible for all. As part of this effort, SETO must track solar cost trends so it can focus its research and development (R&D) on the highest-impact activities. The benchmarks in this report are bottom-up cost estimates of all major inputs to PV and energy storage system installations. Bottom-up costs are based on national averages and do not necessarily represent typical costs in all local markets. Like last year's report, this year's report includes two distinct sets of benchmarks: minimum sustainable price (MSP) benchmarks and modeled market price (MMP) benchmarks. MSP benchmarks can be interpreted as the minimum price a company needs to charge to remain financially solvent in the long term based on the minimum sustainable prices of all inputs including minimum sustainable profit margins. MMP benchmarks can be interpreted as the actual cash sales price a company charges in the given benchmark period. These simplified estimates are useful for tracking technological progress, but they do not reflect all experiences. In fact, no individual estimate under any approach can reflect the diversity of the PV and storage manufacturing and installation industries. Our residential MMP benchmark ($2.90 per watt direct current [Wdc]) is 24% higher than the MSP benchmark ($2.34/Wdc) and 9% lower than our MMP benchmark ($3.18/Wdc) from Q1 2022 in 2022 U.S. dollars (USD). For community solar, our MMP benchmark ($1.75/Wdc) is 18% higher than our MSP benchmark ($1.49/Wdc). Our Q1 2022 benchmark report has no community solar system for comparison. For utility-scale systems with one-axis tracking, our MMP benchmark ($1.17/Wdc) is 22% higher than our MSP benchmark ($0.96/Wdc) and 10% higher than its counterpart ($1.07/Wdc) in Q1 2022 in 2022 USD.

14 SOLAR ENERGY↗

Q1 2023 U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks With Minimum Sustainable Price Analysis Data File

The U.S. Department of Energy's (DOE's) Solar Energy Technologies Office (SETO) aims to accelerate the advancement and deployment of solar technology in support of an equitable transition to a decarbonized economy no later than 2050, starting with a decarbonized power sector by 2035. Its approach to achieving this goal includes driving innovations in technology, hardware, and soft cost reductions to make solar affordable and accessible for all. As part of this effort, SETO must track solar cost trends so it can focus its research and development (R&D) on the highest-impact activities. The benchmarks in this report are bottom-up cost estimates of all major inputs to PV and energy storage system installations. Bottom-up costs are based on national averages and do not necessarily represent typical costs in all local markets. Like last year's report, this year's report includes two distinct sets of benchmarks: minimum sustainable price (MSP) benchmarks and modeled market price (MMP) benchmarks. MSP benchmarks can be interpreted as the minimum price a company needs to charge to remain financially solvent in the long term based on the minimum sustainable prices of all inputs including minimum sustainable profit margins. MMP benchmarks can be interpreted as the actual cash sales price a company charges in the given benchmark period. These simplified estimates are useful for tracking technological progress, but they do not reflect all experiences. In fact, no individual estimate under any approach can reflect the diversity of the PV and storage manufacturing and installation industries.

14 SOLAR ENERGY↗

Evaluation of Centralized Model Based FLISR in a Lab Setup

Utilities are installing advanced distribution management systems (ADMS) around the globe to improve the sensing and control of distribution systems. ADMS is becoming a critical component to improve the resiliency and reliability of distribution systems. These management systems host a multitude of applications that can be used to sense, control, and operate distribution systems. Fault location, isolation, and service restoration (FLISR) is one of the ADMS applications that is critical to improving resilience during fault conditions. FLISR applications use smart, controllable devices that are installed in the distribution system for FLISR operation. These controllable devices include distributed energy resources (DER) and reclosers. Evaluating such ADMS applications before installation in the field can help de-risk the field implementation and avoid costly failures in the field. This paper presents a background on experimental setup that are typically used to evaluate ADMS applications. This is followed by briefly presenting the setup used to evaluate the FLISR application in an off-the-shelf ADMS tool. Finally, results from the evaluation experiments are presented.

94 GMLC - Grid Modernization Laboratory Consortium↗

LBNF/DUNE Nitrogen Refrigeration System Update

The Deep Underground Neutrino Experiment (DUNE) is supported by the infrastructure of the Long Baseline Neutrino Facility (LBNF). The central feature of DUNE is the liquid argon filled cryostats, which house the neutrino detector components. In order to maintain the argon in a liquid state, heat must be continuously removed. Argon condensers will remove this heat, and liquefy the argon, through the evaporation of liquid nitrogen. The supply of liquid nitrogen relies heavily on a near-industrial scale nitrogen refrigeration/liquefaction system. The nitrogen system will be a closed loop, in which the liquid nitrogen is supplied to users and, after being vaporized, is recycled to the nitrogen liquefaction units to be liquefied again. The system will also include nitrogen generation, to increase inventory in the closed loop, as well as to make up for losses. All of this will be installed nearly one mile underground (1.5km) on the 4850 level of the Sanford Underground Research Facility (SURF). The final DUNE vision requires 400kW of liquid nitrogen cooling capacity. Based on the operation modes and phased installation of the experiment, modularity of this cooling capacity is required. Nitrogen liquefaction will occur in four units which will afford a wide operational range of production (nominally 100kW each). Due to the experiment’s location deep underground in an inactive gold mine, there are unique and challenging constraints. These include limited access, footprint, and utilities. This poster describes the engineering effort, and provides an overview of the refrigeration system. The design includes a unique compressor arrangement which is covered in detail. Pictures and models are included where possible to help visualize the system.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Conversion of METL Diagnostic Flowmeters to Permanent Magnet Based Electromagnetic Flowmeters

The Mechanisms Engineering Test Loop (METL) uses three flowmeters to monitor sodium circulation through the main loop, the Cold Trap leg, and the Plugging Meter leg. When constructed, the Cold Trap flowmeter (CTFM) and Plugging Meter flowmeter (PMFM) were equipped with permanent magnets and Hall Sensors. By October of 2019, during normal operations, both the CTFM and PMFM failed, producing either erroneous or zero signals. Repairs to the flowmeters were attempted in January of 2020 but failed to resolve the issues. Therefore, starting in March of 2021, a plan was developed to convert the installed flowmeters to more robust permanent magnet based electromagnetic flowmeters (EMFMs). The Cold Trap EMFM (CT EMFM) and Plugging Meter EMFM (PM EMFM) were fully installed by August of 2021. Initial testing and commissioning were completed in November of 2021. Finally, the first calibration runs were finished in March of 2022. This report discusses the design, conversion, and calibration of the as-built CTFM and PMFM to robust permanent magnet based EMFMs. During the design phase, theoretical models were used to estimate the signal output and required magnet sizes. Then, the CTFM and PMFM were disassembled and converted to EMFMs. After commissioning, the CT EMFM and PM EMFM were calibrated using a ‘Time Transfer Procedure’ carried out with METL Expansion Vessels and Test Vessel Two. The accuracy of the calibration was estimated through an uncertainty analysis. Finally, the report describes some lessons learned for future flowmeter conversions and follow-up work. In total, both METL EMFM’s met the desired performance targets. Testing data showed that the METL EMFMs provide a output signal of roughly 2 mV at 1 GPM and 250 °C. During calibration, flowrates between 0.7 GPM and 2.4 GPM were achieved. In this flow range, calibration coefficients of 0.485 and 0.935 were measured as with errors ranging from 15-5% and 16-5% for the CT EMFM and PM EMFM, respectively. Above 1.5 GPM, the error was assumed to be about 5% for both METL EMFMs. Several points will be considered for future follow-up work on the METL EMFM’s. First, the signal noise issues in the PM EMFM will be addressed. It is likely the source of the noise is due to some stray EMF from a heater. Secondly, the NdFeB magnets will be replaced with a grade that has a Curie temperature above 80 °C. For example, a few grades of NeFeB magnets have Curie temperatures which exceed 150 °C and some SmCo magnets have Curie temperatures as high as 500 °C. Third, more calibration runs will be completed in the range of 0.5-2.5 GPM. This will further improve the accuracy of the calibration coefficient. Fourth, calibration runs will be completed up to 5 GPM. This requires a larger pressure relief valve to be installed on the Expansion Vessel and Test Vessel 2, as well as a revised calibration procedure. Lastly, calibration runs will be completed to account for cold spots in the system, which reduced the inlet temperature of the METL EMFMs. Overall, these points will improve the calibration coefficients derived in this work and also improve the performance of the METL EMFMs.

42 ENGINEERING↗

Installation Assignment Durations and Patterns of Army Personnel

The purpose of this document is to report on the development of personnel assignment duration statistical metrics and statistical descriptions for groups of Army personnel aggregated by rank, career management field, and other descriptors for 32 Continental United States (CONUS) Army installations. This information can be used for generating evidence-based measures of personnel exposure times associated with environmental health considerations at the installation and career management field levels. Assignment duration statistical descriptions were developed to provide temporal metrics for groups of personnel at Army installations as foundational data to support a variety of assessments. Statistical results of personnel assignment durations at the installation level are provided in several formats. The 50th percentile assignment duration represents the median number of days personnel in groups aggregated by rank and career management field spend at the 32 CONUS Army installations in this study. Likewise, other duration percentiles (90th) and quartiles of assignment durations for groups aggregated by rank and career management field spend at each installation were developed. Assignment path analysis provide statistical descriptions of assignment durations at Army installations throughout increments of time (e.g., 5 years, 10 years). Key groupings of assignment paths were achieved by analyzing the duration of assignments at installations in chronological order from entry throughout specified increments of military service to generate the most common assignment paths across the 32 CONUS Army installations in this study. The developed assignment duration analytics and duration statistical descriptions provide foundational temporal metrics for groups of personnel at 32 CONUS Army installations to support a variety of assessments including those by human resource planners and environmental health specialists.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Arc Weld Robotic Arm & Enclosure Seismic Anchorage in B226

The Arc Weld Robotic Arm & Enclosure is adequately anchored by the details shown on sheets SKS-01 through SKS-03. Two different Hilti anchors have been provided to allow for installation flexibility. Existing documentation shows that the existing enclosure base has been anchored with 5/8”Ø Kwik Bolt TZ’s. As a result, it is believed that the existing holes are sized for that 5/8”Ø anchor. The first option is to install a 5/8”Ø Kwik Bolt TZ2, similarly to the existing conditions. The second option is to use a threaded insert anchor. Since the largest allowable diameter of HIS-N insert is 1/2”Ø based on the slab thickness, 2”x2” square plate washers with a 9/16”Ø hole will need to be installed on the top of the existing enclosure base plates to reduce the diameter of the existing holes. This is required for the anchorage to provide proper restraint in a seismic event.

42 ENGINEERING↗

Protection and Restoration Solutions to Reliable and Resilient Integration of Grid-connected PV Installations and Distributed Energy Resources: Design, Testbed, Proof of Work and Impact Studies (Final Report)

To gain a better understanding of the complex transients in a utility grid with a large number of solar PV installations coupled by PWM inverters during the protection and restoration period of the power grid, in this project a kW-level experimental system with dominating inverter-based resources and a hardware-in-loop simulation system with transmission and distribution models, as well as several SEL protective relays have been built and used. The major research findings of the project are summarized below in two perspectives: Experimental research: A self-organized ultra-high frequency solitary waveform is discovered and demonstrated in the hardware experimental system. Despite the familiarities, such a solitary waveform is distinct from any harmonics, transient, or resonance waves in that, it is 1) non-dispersive over time and space, 2) not associated with any active source or the linear superposition of sources, 3) half-cycle asymmetric, 4) not responding to filters or change of system characteristic resonance frequency, 5) ubiquitous as it occurs simultaneously everywhere in the system from DC supply, power lines, and the utility grid, and 6) explosive through tripping the protection or damaging susceptible devices or circuits. Analytical study: The nature of such a new waveform and an analytical explanation of its formation are studied based on related physics and non-linear science principles, with the following highlights: 1) such a new waveform follows the solutions to the Non-linear Schrödinger equation, so the classic linear perturbation theory is unable to explain or predict such a unique waveform as confirmed with the research team of RTDS; 2) the critical condition of occurrence of such a waveform is derived, which indicates that the breakings of solitary wave is a system synchronous issue between the utility grid in the 60Hz phasor domain and duty-ratio modulation of DC sources in the inverter switching frequency domain; 3) such a waveform carries energy mass so it could be detrimental; 4) such a waveform is deceiving as it is not readily detectable in the energy propagation direction by the primary protection equipment, while it is detrimental in the perpendicular direction of energy propagation, i.e. voltage direction. Thus, it has more likely challenges to the second primary equipment and devices, particularly at the weakest link and point such as aging insulation and inappropriate setting of susceptible devices. Therefore, such a waveform can be easily ignored in the aftermath investigation. The intellectual merits: The experimental discovery reveals certain unfamiliar transient phenomena that could challenge the integration of large-scale grid-connected solar PV installation during the group ride-through period of solar PV installations, commissioning of large-solar farms, or dramatic change of solar radiation conditions. Particularly, the research findings suggest that the occurrence of the unfamiliar transient phenomena is uniquely associated with the inverter-based solar PV installation, which is less likely to happen for rotary energy systems. The physics and non-linear science-based research work laid down an analytical path to the challenging transient stability problems including those that have been observed currently and future calls. Both experimental and analytical research results explain the limitation of many current research effects including some DoE research undertakings as well as possible solutions. The broader impacts: The research outcome of the project advances the understanding of the possible transient problems for the integration of inverter-based solar PV installation. It also highlights the theoretical and technical barriers for applying the conventional theory and technology to design and implement countermeasures against their adverse impacts of the large-scale solar PV installation and operation on grid reliability and security. More broadly, the research outcomes have shed some light on the open, fundamental challenges in the integration of large-scale solar photovoltaic energy into current and next-generation power grids across the country, and worldwide. The advanced physics and non-linear science-based analysis open up a path to harmonization of the renewables for societal energy needs via building a resilient and sustainable electric power infrastructure.

14 SOLAR ENERGY↗

Surface Water Quality Data from Beaver-Impacted Streams; Trail Creek and East River, Colorado 2025

This data package contains surface water chemistry measurements collected in 2025 to evaluate how beaver damming and low-tech process-based stream restoration influence water quality and metal mobility in mountainous headwater systems of the Upper Colorado River Basin. Sampling was conducted at Trail Creek (Taylor Park watershed, Colorado), a tributary undergoing restoration through installation of low-tech process-based structures (i.e., beaver dam analogs), and at off-channel beaver ponds within the East River floodplain (East River watershed, Colorado). Samples were collected along longitudinal transects spanning upstream control reaches, beaver-influenced ponded reaches, and downstream segments. Additional samples were collected from near-surface pore waters within a beaver dam seepage face. The dataset includes concentrations of major and trace elements measured by inductively coupled plasma–mass spectrometry (ICP-MS) and inductively coupled plasma–optical emission spectrometry (ICP-OES), major anions measured by ion chromatography (IC), and dissolved organic carbon (DOC; reported as non-purgeable organic carbon, NPOC). Samples were size-fractionated at 0.45 micrometers (µm), 0.22 µm, and 0.02 µm to distinguish particulate (>0.45 µm), colloidal (0.22–0.02 µm), and dissolved (<0.02 µm) fractions. The data package consists of comma-separated value (.csv) files containing tabulated chemical concentration data, sample metadata (site identifiers, geographic coordinates, sampling dates, fraction type), and quality control flags. All files are provided in open, non-proprietary formats that can be accessed using standard data analysis software such as Microsoft Excel, R, Python, MATLAB, or other programs capable of reading .csv files. Units, detection limits, and analytical methods are documented in accompanying metadata files. The dataset is designed to support analyses of (1) how beaver impoundment and restoration structures alter elemental partitioning and transport, (2) the role of iron and organic carbon in mediating trace metal mobility, and (3) reach-scale changes in water quality across restoration gradients. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

Anions↗

Exploring Social Dynamics of Hard-Disk Drives Circularity with an Agent-Based Approach: Preprint

By 2025, it is estimated that installed data storage in the US will be 2.2 Zettabytes, generating about 50 million units of end-of-life hard-disk drives (HDDs) per year. The circular economy tackles waste issues by maximizing value retention in the economy, for instance, through reuse and recycling. However, the reuse of hard disk drives is hindered by the lack of trust organizations have toward other means of data removal than physically destroying HDDs. Here, an agent-based approach explores how organizations’ decisions to adopt other data removal means affect HDDs circularity. The model applies the theory of planned behaviour to model the decisions of HDDs end-users. Results demonstrate that the attitude (which is affected by trust) of end-users toward data-wiping technologies acts as a barrier to reuse. Moreover, social pressure can play a significant role as organizations that adopt CE behaviours can set an example for others.

28 EE - Advanced Manufacturing Office (EE-5A)↗

Selection of Well Locations for Saturated Zone Monitoring at the E-Area Low Level Waste Facility

Savannah River Site (SRS) has adopted a revised approach to performance monitoring of the E- Area Low Level Waste Facility (ELLWF) that adds a saturated zone component to the existing vadose zone monitoring program (Kubilius, 2019). The revised monitoring approach specifies that eight additional water table wells be installed near Slit Trench 1 (ST1) and Engineered Trench 2 (ET2). Six wells will be installed at locations characterized in 2017 and 2018. These include four wells near ET2 (ELF001D, ELF002D, ELF003D, and ELF004D) at locations identified by Kubilius (2019) and two wells north of ST1 (ELF005D and ELF006D) at locations finalized in this report. Additionally, two wells (ELF007D and ELF008D) are to be installed at locations south of ST1 based on characterization work completed in 2020 and documented in this report. This area is near well cluster BGX-2 between the Mixed Waste Management Facility (MWMF) and the ELLWF. The area is upgradient of ELLWF and, contamination in the water table aquifer is sourced from MWMF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗