Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “infusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

IT infusion

Infusing IT technology is a perennial challenge. The Technology Infusion and Maturity Assessment approach of Cornford & Hicks is shown applied to an example of IT infusion: moedl-based V&V of spacecraft software.

technical keywords↗

A Successful Infusion Process for Enabling Lunar Exploration Technologies

The NASA Vision for Space Exploration begins with a more reliable flight capability to the International Space Station and ends with sending humans to Mars. An important stepping stone on the path to Mars encompasses human missions to the Moon. There is little doubt throughout the stakeholder community that new technologies will be required to enable this Vision. However, there are many factors that influence the ability to successfully infuse any technology including the technical risk, requirement and development schedule maturity, and, funds available. This paper focuses on effective infusion processes that have been used recently for the technologies in development for the lunar exploration flight program, Constellation. Recent successes with Constellation customers are highlighted for the Exploration Technology Development Program (ETDP) Projects managed by NASA Glenn Research Center (GRC). Following an overview of the technical context of both the flight program and the technology capability mapping, the process is described for how to effectively build an integrated technology infusion plan. The process starts with a sound risk development plan and is completed with an integrated project plan, including content, schedule and cost. In reality, the available resources for this development are going to change over time, necessitating some level of iteration in the planning. However, the driving process is based on the initial risk assessment, which changes only when the overall architecture changes, enabling some level of stability in the process.

Over, Ann P.↗

Research Infusion Collaboration: Finding Defect Patterns in Reused Code

The 'Finding Defect Patterns in Reused Code' Research Infusion Collaboration was performed by Jet Propulsion Laboratory/Caltech under Contract 104-07-02.679 102 197 08.14.4. This final report describes the collaboration and documents the findings, including lessons learned.The research infusion collaboration characterized, using Orthogonal Defect Classification, defect reports for code that will be reused in mission-critical software on Deep Space Network Antenna controllers. Code reuse is estimated to be 90%, so it is important to identify systemic defects, or patterns, prior to reuse of this code. The work also identified ways to avoid certain types of defects and to test more efficiently.The primary objectives of the project were:to analyze defect patterns of the code to be reused based on the defects'Orthogonal Defect Classification (ODC)and to achieve a successful infusion of ODC to a project.

orthogonal defect classification (ODC)↗

Infusion Processing of Phenylethynyl Terminated Imides by High Temperature RTM and VARTM

Fabrication of composite structures using infusion processes such as resin transfer molding (RTM) and vacuum assisted resin transfer molding (VARTM) is generally more affordable than conventional autoclave techniques. Recent efforts have focused on adapting both technologies for the fabrication of high temperature (HT) resistant composites. Due to their low melt viscosity and long melt stability, certain phenylethynyl terminated imides (PETI) can be processed into composites using these high temperature out-of-autoclave processes. In the current study, two PETI resins, LARC(TradeMark) PETI-330 and LARC(TradeMark) PETI-8 have been used to make test specimens using both RTM and VARTM. For aerospace applications, a void fraction of less than 2% is desired. Traditionally, RTM has had the advantage over VARTM for generating composites with low void content. However, the process is limited in terms of size. Work at NASA LaRC has incorporated modifications to the thermal cycle used in laminate fabrication that have reduced the void content significantly (typically 1-3%) using the current HT-VARTM process. For composite fabrication by both RTM and VARTM, the resins were infused into three carbon fiber preforms (T650-35-3k 5HS, IM7-6k 5HS, and IM7-6k Uniweave) at 316 C and 260 C respectively and cured up to 371 C. The details of the RTM processing carried out at the University of Akron are discussed in this work along with a brief description of the HT-VARTM processing carried out at NASA-LaRC. Photomicrographs of the panels were taken and void contents were determined by acid digestion. Mechanical properties (short beam shear, SBS) of the panels fabricated by both infusion processes were determined at room temperature as well as at various elevated temperatures. The results of this work are presented herein.

Ghose, Sayata↗

Process Optimization of Bismaleimide (BMI) Resin Infused Carbon Fiber Composite

Engineers today are presented with the opportunity to design and build the next generation of space vehicles out of the lightest, strongest, and most durable materials available. Composites offer excellent structural characteristics and outstanding reliability in many forms that will be utilized in future aerospace applications including the Commercial Crew and Cargo Program and the Orion space capsule. NASA's Composites for Exploration (CoEx) project researches the various methods of manufacturing composite materials of different fiber characteristics while using proven infusion methods of different resin compositions. Development and testing on these different material combinations will provide engineers the opportunity to produce optimal material compounds for multidisciplinary applications. Through the CoEx project, engineers pursue the opportunity to research and develop repair patch procedures for damaged spacecraft. Working in conjunction with Raptor Resins Inc., NASA engineers are utilizing high flow liquid infusion molding practices to manufacture high-temperature composite parts comprised of intermediate modulus 7 (IM7) carbon fiber material. IM7 is a continuous, high-tensile strength composite with outstanding structural qualities such as high shear strength, tensile strength and modulus as well as excellent corrosion, creep, and fatigue resistance. IM7 carbon fiber, combined with existing thermoset and thermoplastic resin systems, can provide improvements in material strength reinforcement and deformation-resistant properties for high-temperature applications. Void analysis of the different layups of the IM7 material discovered the largest total void composition within the [ +45 , 90 , 90 , -45 ] composite panel. Tensile and compressional testing proved the highest mechanical strength was found in the [0 4] layup. This paper further investigates the infusion procedure of a low-cost/high-performance BMI resin into an IM7 carbon fiber material and the optical, chemical, and mechanical analyses performed.

Ehrlich, Joshua W.↗

Vacuum Infusion Process Development for Conformal Ablative Thermal Protection System Materials

Conformal ablators are low density composite materials comprised of a flexible carbon felt based fibrous substrate and a high surface area phenolic matrix. These materials are fabricated to near net shape by molding the substrate, placing in a rigid matched mold and infusing with liquid resin through a vacuum assisted process. The open mold process, originally developed for older rigid substrate ablators, such as PICA, wastes a substantial amount of resin. In this work, a vacuum infusion process a type of liquid composite molding where resin is directly injected into a closed mold under vacuum is advanced for conformal ablators. The process reduces waste over the state-of-the-art technique. Small, flat samples of Conformal Phenolic Impregnated Carbon Ablator are infused using the new approach and subjected to a range of curing configurations and conditions. Resulting materials are inspected for quality and compared to material produced using the standard process. Lessons learned inform subsequent plans for process scale up.

TPS↗

Recent development on nitrogen infusion work towards high Q and high gradient

A quality factor as high as 2 × 1010 at 1.5 GHz was achieved at a gradient of 35 MV/m by 800 °C annealing and N-infusion at 140 °C. A comparison of the field dependence of the surface resistance after N-infusion with a recent theoretical model that extends the calculation of the BCS surface resistance to high rf fields suggests an increase in the quasiparticles¿ relaxation time with increasing infusion temperature, which could be due to a decreasing density of subgap states. Nb coupons treated similarly showed the formation of thicker oxynitride layer on the surface beneath thin dielectric Nb2O5 layer. A plausible explanation for the improved Q0 is that the oxynitride layer on the Nb surface adds additional electron scattering within RF penetration depth.

Dhakal, P.↗

Novel nonwetting solid-infused surfaces for superior fouling mitigation

Fouling is a ubiquitous issue in several environmental and energy applications. Here we introduce novel nonwetting solid-infused surfaces (SIS) with superior anti-fouling characteristics that are durable than conventional nonwetting surfaces in a dynamic flow environment. A systematic study is presented to elucidate the fouling mitigation performance of SIS in comparison to lubricant-infused surface (LIS) and conventional smooth surface. Copper tubes with SIS, LIS or smooth inner walls are fabricated and subjected to accelerated calcium sulfate fouling in a flow fouling experimental setup. Fouling on the various surface types is quantified in terms of asymptotic fouling resistance, and the fundamental morphological differences in the interactions of the foulant and the various surface types are analyzed. Based on a systematic sweep of the parameter combinations using design of experiments and Taguchi analysis, an analytical dependence of asymptotic fouling resistance on the governing parameters namely, Reynolds number, foulant concentration and temperature is derived. The analytical model is shown to predict the asymptotic fouling resistance to within 20% accuracy with a 95% confidence. In addition, for the first time, the effects of shear durability on the fouling mitigation performance of LIS vis-à-vis SIS are studied. It is shown that the novel nonwetting SIS offers a robust option for superior fouling mitigation over LIS in the long run.

42 ENGINEERING↗

Hepatic Arterial Infusion Chemotherapy Using Fluorouracil Followed by Systemic Therapy Using Oxaliplatin Plus Fluorouracil and Leucovorin for Patients with Unresectable Liver Metastases from Colorectal Cancer

The purpose of this study was to assess retrospectively the sequential treatment of hepatic arterial infusion (HAI) chemotherapy followed by systemic therapy using oxaliplatin plus 5-flourouracil (5-FU) and leucovorin, namely, FOLFOX, for patients with liver metastases from colorectal cancer. We reviewed 20 patients with unresectable liver metastases from colorectal cancer. Patients were initially treated with HAI chemotherapy until disease progression (5-fluorouracil, 1000 mg/m{sup 2} intra-arterial infusion, weekly) and then with FOLFOX thereafter (FOLFOX4, n = 13; modified FOLFOX6, n = 7). Adverse events, tumor response, and time to progression for each therapy were evaluated retrospectively, and overall survival was estimated. Toxicity of HAI chemotherapy was generally mild. Of 20 patients, adverse events leading to treatment discontinuation occurred in only 1 patient (5%) during initial therapy using HAI chemotherapy, while 9 patients (45%) exhibited adverse events during subsequent FOLFOX therapy. For HAI chemotherapy and FOLFOX, objective response rates were 85.0% and 35.0%, respectively, and median time to progression was 11.6 and 5.1 months, respectively. Median overall survival was 30.1 months. In conclusion, the sequence of HAI chemotherapy followed by FOLFOX is a promising treatment strategy for the long-term use of active chemotherapeutic agents, leading to a superior tumor response and fewer toxic effects in patients with unresectable liver metastases from colorectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of convection heat transfer on multiscale rough superhydrophobic and liquid infused surfaces

Multiscale rough superhydrophobic or slippery liquid infused porous surfaces have gained much interest in recent years for their improved transport phenomena properties. While there have been several studies on drag reduction and condensation on non-wetting surfaces, convection heat transfer that is important in many thermal and thermochemical applications has not been addressed systematically. Here, this article utilizes a fractal description of rough surface topographies to develop analytical models for the Nusselt number and the thermal hydraulic factor for fluid flow and heat transfer inside a cylinder with non-wetting surfaces. For air-infused superhydrophobic surfaces, the model considers the dynamic stability of the air/fluid interface in the asperities. Using the analytical formulations and the stability criteria, systematic studies are presented on the effects of the fractal surface parameters, cylinder radius and Reynolds number on the convective heat transfer characteristics, from which surface texture design maps are developed for maximizing the convection heat transfer. It is shown that multiscale non-wetting surfaces are most effective in the range of lower Reynolds number and small cylinder radius for achieving the best convective heat transfer and thermal hydraulic performance. Applying the models to actual non-wetting surface topographies fabricated using electrodeposition and chemical etching, it is shown that contrary to prevailing notion, superhydrophobicity, characterized by the highest contact angles, does not always lead to the maximum convective heat transfer performance, and that under certain fluid flow conditions, hydrophobic surfaces may offer a greater thermal performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Next Generation Hydrogen Storage Vessels Enabled by Carbon Fiber Infusion with a Low Viscosity, High Toughness System

Onboard hydrogen storage for fuel cell vehicles holds considerable commercial promise which could be accelerated by lower cost storage vessels. In past years, the use of lower cost reinforcing fiber had been studied as an intuitive avenue to reduce vessel costs. Although the matrix resin does not play a large role in bearing stress loads in many areas of a filament wound pressure vessel, the matrix is relied upon for stress transfer between fibers and appears to play an important role in certain regions of the vessel construction such as the “tangent region” where the cylinder section transitions to the dome. Also, the matrix resin can play a role in the damage tolerance of vessels after impact events. Furthermore, the effect of dry spots or voids in the laminate can affect stress transfer between fibers in a manner that is challenging to quantify. Therefore, excess fiber must be used to account for this variability in performance. Unfortunately, in the case hydrogen pressure vessels the cost of the vessel is strongly dependent on the amount of carbon-fiber used in the design and manufacturing. An extensive investigation on the use of non-traditional fabrication processes enabled by an ultra-low viscosity thermoset resin (<10 cP) with high fracture toughness was conducted to determine the opportunity to reduce carbon-fiber usage and the associated high cost. The hypothesis was based on enabling a lower variation in vessel performance from a reduction in void defects (often found with traditional wet-winding) and a more defect-tolerant vessel resulting from use of a matrix resin with high fracture toughness. These two features were anticipated to justify a more aggressive design approach to the vessel winding pattern. From the work in this project, the potential use of the vacuum infusion approach to produce high quality vessels was validated. However, the team recognized the need to re-optimize the design, the dry-process, and the vacuum infusion process at each scale-up stage. During the planning phase, the critical need to re-optimize at this frequency was under-estimated. Also, the team identified the lack of industry testing standards on subscale parts for providing predictive value of vessel performance. Therefore, significant effort is needed to produce statistically significant numbers of vessels. To produce such numbers of vessels the project needed in retrospect to partner closely with a series vessel manufactures to develop a proof of concept production line to make the vessels. However, without the appropriate data, a manufacturing partner was challenging to fully engage during this timeline. New technologies relying on changing raw materials and manufacturing processes carry inherent risks. This project did not reach its ultimate objectives of demonstrated a vessel with lower carbon-fiber. But some companies expressed interest in learning from the partial successes of this project for future challenges in pressure vessel applications.

08 HYDROGEN↗

Resistance to outflow of cerebrospinal fluid after central infusions of angiotensin

Infusions of artificial cerebrospinal fluid (CSF) into the cerebroventricles of conscious rats can raise CSF pressure (CSFp). This response can be modified by some neuropeptides. One of these, angiotensin, facilitates the rise in CSFp. We measured CSFp in conscious rats with a computerized system and evaluated resistance to CSF outflow during infusion of artificial CSF, with or without angiotensin, from the decay kinetics of superimposed bolus injections. Angiotensin (10 ng/min) raised CSFp (P less than 0.05) compared with solvent, but the resistance to CSF outflow of the two groups was similar (P greater than 0.05). Because CSFp was increased by angiotensin without an increase in the outflow resistance, a change in some volume compartment is likely. Angiotensin may raise CSFp by increasing CSF synthesis; this possibility is supported, since the choroid plexuses contain an intrinsic isorenin-angiotensin system. Alternatively, angiotensin may dilate pial arteries, leading to an increased intracranial blood volume.

NASA Discipline Cardiopulmonary↗

Infusing Software Engineering Technology into Practice at NASA

We present an ongoing effort of the NASA Software Engineering Initiative to encourage the use of advanced software engineering technology on NASA projects. Technology infusion is in general a difficult process yet this effort seems to have found a modest approach that is successful for some types of technologies. We outline the process and describe the experience of the technology infusions that occurred over a two year period. We also present some lessons from the experiences.

software assurance↗

A Fast Technology Infusion Model for Aerospace Organizations

A multi-year Fast Technology Infusion initiative proposes a model for aerospace organizations to improve the cost-effectiveness by which they mature new, in-house developed software and hardware technologies for space mission use. The first year task under the umbrella of this initiative will provide the framework to demonstrate and document the fast infusion process. The viability of this approach will be demonstrated on two technologies developed in prior years with internal Jet Propulsion Laboratory (JPL) funding. One hardware technology and one software technology were selected for maturation within one calendar year or less. The overall objective is to achieve cost and time savings in the qualification of technologies. At the end of the recommended three-year effort, we will have demonstrated for six or more in-house developed technologies a clear path to insertion using a documented process that permits adaptation to a broad range of hardware and software projects.

technology readiness level↗

Evaluation of RTM370 Polyimide Composites by Resin Film Infusion (RFI)

RTM370 imide oligomer based on 2,3,3',4'-biphenyl dianhydride (a-BPDA), 3,4'-oxydianiline (3,4'-ODA) and terminated with the 4-phenylethynylphthalic (PEPA) endcap has been shown to exhibit a low melt viscosity (10-30 poise) at 280 C with a pot-life of 1-2 h and a high cured glass-transition temperature (Tg) of 370 C. RTM370 resin has been successfully infused into fiberglass-stitched T650-35 carbon-fabric preforms (ranged from 3- to 6-mm thick) by resin film infusion (RFI). The resulting composite panels were inspected by ultrasonic C-scan and by photomicrographs before and after post-curing as a quality control. Mechanical tests such as unnotched compression (UNC), open-hole compression (OHC), and short-beam shear strength (SBS) at ambient and elevated temperatures were performed before and after isothermal aging at 288 C for 1000 h to assess high-temperature performance. Thermal cycling of RTM370 stitched composites was also conducted from -54 C to 288 C for up to 1600 cycles to evaluate the microcrack resistance of RTM370 polyimide composites fabricated by RFI.

Polyimide↗

Open-Hole Testing of Resin Infused Carbon Composite Laminates to Facilitate Damage Growth and Failure Analysis Tools for Structural Design

In manufacturing of carbon-fiber reinforced composite aircraft structures, resin infusion offers a highly repeatable process for manufacturing structural components with resin content control, low labor requirements, and complex curvatures. To further understand the structural capabilities of res-in infused composites (RIC), this study – as part of the NASA-led Hi-Rate Composite Aircraft Manufacturing project efforts – performed open hole tension (OHT) and open hole compression (OHC) testing on RIC laminates. This testing provides information on the damage morphology and growth characteristics of RICs, which fuels the development and evaluation of analysis tools for progressive damage growth and failure responses. X-ray computed tomography (XCT) was implemented on each OHC and OHT specimen prior to mechanical testing to identify preexisting damage and/or defects. Two OHT and OHC specimens were loaded monotonically to failure and an additional OHT and OHC specimen were loaded intermittently at defined conditions and XCT scanned after each run. From the data obtained in this study, damage mechanisms leading to failure were identified, damage morphology and size were assessed, and damage initiation and failure loads were measured.

HiCAM↗

End-hole Versus Microvalve Infusion Catheters in Patients Undergoing Drug-Eluting Microspheres-TACE for Solitary Hepatocellular Carcinoma Tumors: A Retrospective Analysis

Introduction: Pre-transplant locoregional therapy for hepatocellular carcinoma (HCC) during bridge-to-transplant impacts recurrence and survival rates following liver transplantation. Optimizing the effectiveness of transarterial chemoembolization (TACE) in this population is imperative, and microvalve infusion catheters offer a means of such improvement. Methods: All treatment-naive patients with solitary HCC tumors < 6.5 cm who underwent drug-eluting microspheres (DEM) TACE between 04/2015 and 08/2017 were retrospectively reviewed. Eighty-eight included patients underwent DEM-TACE with either standard end-hole catheters (EH) or microvalve infusion catheters (MVI). The EH (n = 70) and MVI (n = 18) cohorts had similar baseline tumor size, laboratory values, and tumor etiologies. Results: Initial objective response rates were significantly higher in MVI vs. EH (100% vs. 76.5%, p = 0.019). There was no difference in adverse events between groups (p = 0.265). MVI patients exhibited lower AST (p = 0.003) and ALT (p = 0.044) at 6 months. Blinded pathological analysis of explanted livers showed greater concentrations of microspheres within the tumor relative to the surrounding tissue in MVI explants (88.7 ± 10.6%) versus the EH explants (55.3 ± 32.7%) (p = 0.002). There was significantly higher percentage tumor necrosis in the MVI group (89.0 ± 2.2%) compared with the EH group (56.1 ± 44.5%) (p = 0.006). Conclusion: In this retrospective study of a single-center cohort, DEM-TACE procedures with MVI were associated with improved tumor response, increased deposition of microspheres within tumor tissue, and higher percentage tumor necrosis at explant relative to those performed using EH catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advancing molecular machine learning representations with stereoelectronics-infused molecular graphs

Molecular representation is a critical element in our understanding of the physical world and the foundation for modern molecular machine learning. Previous molecular machine learning models have used strings, fingerprints, global features and simple molecular graphs that are inherently information-sparse representations. However, as the complexity of prediction tasks increases, the molecular representation needs to encode higher fidelity information. This work introduces a new approach to infusing quantum-chemical-rich information into molecular graphs via stereoelectronic effects, enhancing expressivity and interpretability. Learning to predict the stereoelectronics-infused representation with a tailored double graph neural network workflow enables its application to any downstream molecular machine learning task without expensive quantum-chemical calculations. We show that the explicit addition of stereoelectronic information substantially improves the performance of message-passing two-dimensional machine learning models for molecular property prediction. We show that the learned representations trained on small molecules can accurately extrapolate to much larger molecular structures, yielding chemical insight into orbital interactions for previously intractable systems, such as entire proteins, opening new avenues of molecular design. Finally, we have developed a web application (simg.cheme.cmu.edu) where users can rapidly explore stereoelectronic information for their own molecular systems.

Boiko, Daniil A↗