Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “imaging instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Chemistry imaging and distribution analysis of rare earth elements in coal using LIBS and LA-ICP-MS instruments

Currently, demand for rare earth elements (REEs) increased significantly. Coal is actively evaluated as potential economic sources for extraction of REEs. Here, in this work, laser-induced breakdown spectroscopy (LIBS) was evaluated for rapid estimation of REEs content and their distribution in the natural coal samples. The results were compared with similar laser ablation–inductively coupled plasma–mass spectrometry (LA-ICP-MS) measurements. Thirteen coal samples (nine standard samples and five natural samples) were used in this study. Powder samples were pressed into pellets while coal chunks were directly ablated for data recording. Pellets of the powder standard samples were used to optimize the data acquisition system and then data recorded with this optimized system was used to identify the proper data acquisition and analysis models. After establishing the proper data acquisition system and analysis model using the standard samples, natural coal samples in powder form and their chunks were utilized to record LIBS and LA-ICP-MS spectra. Multivariate calibration models were developed using four of the natural samples, which were evaluated by predicting the REE content in the fifth sample. Principal component analysis was performed on the LIBS data obtained from the natural samples and it classified all the samples with high accuracy. Two-dimensional (2D) elemental mapping on coal chunk samples was also performed using both LIBS and LA-ICP-MS to study the distribution of REEs in the samples. The resulting elemental images and their correlations can be used to infer mineral distributions.

01 COAL, LIGNITE, AND PEAT↗

Phase II Final Technical Report: Dynamic Gamma-ray Imaging for In Vivo Tracking of Microelement Transport Across Plant-Microbial Systems

The Department of Energy Office of Biological and Environmental Research (DOE BER) Mesoscale to Molecules Bioimaging Technology Program aims to develop new imaging and measurement technology to enable in situ and dynamic imaging across a range of spatial and temporal scales. Various imaging modalities are required to span the complete spatiotemporal landscape for bioenergy and environmental bioimaging needs. The high-resolution gamma-ray spectroscopy, imaging, and sensitivity of new high-purity germanium (HPGe) instruments provide a unique opportunity to complement and enhance these research goals. The HPGe-based Gamma-ray Imager for Plant Research (GIPR) developed here provides non-invasive, in vivo measurements to dynamically track the uptake and distribution of multiple gamma-emitting radioactive elements simultaneously as they move from the soil microbiome into living plants. The hand portable GIPR utilizes commercially available radioisotopes to provide spatial and temporal imaging of plant microelement exchange for the broader scientific community.

Kiser, Matthew↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Laboratory-Based Micro-X-ray Computed Tomography of Energy Materials at Idaho National Laboratory

Abstract The Idaho National Laboratory (INL) has implemented laboratory-based micro-X-ray computed tomography in a laboratory equipped for the examination of highly radioactive samples. This capability provides nondestructive three-dimensional volumetric information on samples to inform subsequent traditional destructive examinations as well as real-world inputs for high-fidelity scientific modeling. Samples can be imaged with spatial resolutions ranging from several hundred nm/voxel up to ~ 100 µm/voxel. The best usable spatial resolution achieved to date is 384 nm/voxel with this instrument, while the highest radiological dose rate of a sample imaged is ~ 60 R/h β/γ on contact. Advanced data analysis, including custom tomographic reconstruction and segmentation methods, have also been developed to support this capability. In addition to traditional digital X-ray radiography and tomography, this instrument is also able to visualize in situ tensile and compression testing as well as perform diffraction contrast tomography. This work describes the X-ray computed tomography post-irradiation examination capabilities at INL, as well as detailing a variety of applications this instrument has examined.

36 MATERIALS SCIENCE↗

Tracing cosmic gas in filaments and halos: Low-redshift insights from the kinematic Sunyaev-Zel’dovich effect

In this work, we leverage cosmic microwave background (CMB) data from the Atacama Cosmology Telescope (ACT) and LSS data from the imaging survey conducted by the Dark Energy Spectroscopic Instrument (DESI) to study the distribution of gas around galaxy groups at low redshift, z ≈ 0.3, via the kinematic Sunyaev-Zel'dovich (kSZ) effect. In particular, we perform velocity-weighted stacking on the photometric galaxies from the Bright Galaxy Survey (BGS) to isolate the monopole and quadrupole of the kSZ signal, orienting the stacked images along 2D filaments identified using the Hessian of the projected gravitational potential. We find a 7.2σ detection in the monopole of the signal (i.e., the gas density profile) and a 4σ detection in the quadrupole (m = 2), constituting the first measurement of the alignment between gas distribution and the cosmic web through the kSZ effect. As it is a linear probe of the local gas density, the kSZ has heightened sensitivity to the warm-hot intergalactic medium (WHIM), which is believed to house the majority of the "missing baryons."Mapping out the gas density at low redshifts, as enabled by our measurements, is crucial for weak lensing surveys, for which the impact of baryons on small scales is a major impediment. We compare the anisotropic signal against two hydrodynamical simulations, TNG300-1 and Illustris, which have very different baryonic feedback prescriptions. We find that the anisotropic signal measured in the data is comparable but slightly larger and more extended compared with the simulations. Further, this suggests that there is excess accretion and feedback taking place through the filaments, hinting at the possible presence of spin-filament alignment of the BGS objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Quantitative approaches for multiscale structural analysis with atomic resolution electron microscopy

Atomic-resolution imaging with scanning transmission electron microscopy is a powerful tool for characterizing the nanoscale structure of materials, in particular features such as defects, local strains, and symmetry-breaking distortions. In addition to advanced instrumentation, the effectiveness of the technique depends on computational image analysis to extract meaningful features from complex datasets recorded in experiments, which can be complicated by the presence of noise and artifacts, small or overlapping features, and the need to scale analysis over large representative areas. Here, we present image analysis approaches which synergize real and reciprocal space information to efficiently and reliably obtain meaningful structural information with picometer scale precision across hundreds of nanometers of material from atomic-resolution electron microscope images. Damping superstructure peaks in reciprocal space allows symmetry-breaking structural distortions to be disentangled from other sources of inhomogeneity and measured with high precision. Real-space fitting of the wavelike signals resulting from Fourier filtering enables absolute quantification of lattice parameter variations and strain, as well as the uncertainty associated with these measurements. Implementations of these algorithms are made available as an open source python package.

36 MATERIALS SCIENCE↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Chatbots can guide experimentalists to avoid many common mistakes in measuring fluorescence spectra

The concepts of fluorescence spectroscopy are well established, yet the experimental collection of a spectrum is susceptible to a range of errors. A recent study showed that chatbots – derived from substantial advances in artificial intelligence – can provide practical assistance to the experimentalist during collection of absorption spectra and thereby achieve improved quality. Fluorescence, while the complement of absorption, is prone to a far richer array of experimental errors encompassing environmental factors, instrumental settings, and experimentalist mistakes. Here, 10 chatbots (ChatGPT 5, Gemini 2.5 Pro, Microsoft Copilot, Meta AI Llama 4, Claude Sonnet 4.5, X.ai Grok 4, Perplexity Pro, DeepSeek V3.1, Z.ai GLM-4.6, and KIMI K2) have been evaluated for the suitability in providing quality-improvement advice to the experimentalist during acquisition of fluorescence spectra. Significant opportunities for practical assistance are noted, although intervention by a domain expert is often required. Here, if combined with image recognition and/or signal processing, chatbots embedded in instruments may enable real-time guidance during fluorescence data acquisition.

Artificial intelligence↗

ARMing the Edge: Demonstration of Edge Computing Field Campaign Report

Edge computing enables “next-to-instrument” control and intelligent data volume reduction and the potential for autonomous, adaptive measurement strategies such as for automated control of scan strategies for Doppler lidar (DL). Instruments with narrow bandwidth connections (e.g., ship and remote sites) can do scene determination and save phenomenon-appropriate data. For example, Doppler spectrum can be saved when clouds are detected by the instrument or automatic moment detection can take place in camera images and only preserve spectrum when non-monomodal spectra are detected. Automated control at the edge involves changing the sampling (temporal or scanning strategy) of an instrument to suit the phenomena both present and being studied (Jackson et al. 2020). Both data processing and instrument control introduces the possibility of a software-defined instrument.

54 ENVIRONMENTAL SCIENCES↗

In-orbit performance of the soft X-ray imaging telescope Xtend aboard XRISM

Here, we present a summary of the in-orbit performance of the soft X-ray imaging telescope Xtend onboard the X-Ray Imaging and Spectroscopy Mission (XRISM), based on in-flight observation data, including first-light celestial objects, calibration sources, and results from the cross-calibration campaign with other currently operating X-ray observatories. XRISM/Xtend has a large field of view of ${38{^{\prime }_{.}}5}$ $\times$ ${38{^{\prime }_{.}}5}$, covering an energy range of 0.4–13 keV, as demonstrated by the first-light observation of the galaxy cluster Abell 2319. It also features an energy resolution of 170–180 eV at 6 keV, which meets the mission requirement and enables us to resolve He-like and H-like Fe K$\alpha$ lines. Throughout the observation during the performance verification phase, we confirm that two issues identified in the Soft X-ray Imager (SXI) onboard the previous Hitomi mission—light leakage and crosstalk events—are addressed and suppressed in the case of Xtend. A joint cross-calibration observation of the bright quasar 3C 273 results in an effective area measured to be $\sim$420 cm$^{2}$ at1.5 keV and $\sim$310 cm$^{2}$ at 6.0 keV, which matches values obtained in ground tests. We also continuously monitor the health of Xtend by analyzing overclocking data, calibration source spectra, and day-Earth observations; the readout noise is stable and low, and contamination is negligible even one year after launch. A low background level compared with other major X-ray instruments onboard satellites, combined with the largest grasp ($\Omega _{\rm eff}\sim 60$ cm$^2$ deg$^2$) of Xtend, will not only support Resolve analysis, but also enable significant scientific results on its own. This includes near-future follow-up observations and transient searches in the context of time-domain and multi-messenger astrophysics.

instrumentation: detectors: Xtend↗

Adaptively coupled phase retrieval in multi-peak Bragg coherent diffraction imaging

Recent advances in Bragg coherent diffraction imaging (BCDI) experimental techniques permit routine measurement of multiple Bragg peaks from a single crystalline grain. The resulting images contain the full lattice distortion vector field which can be differentiated to provide lattice strain and rotation. With the advent of fourth-generation synchrotron light sources, such multi-peak datasets are produced at high rates, facilitating the need for rapid phase retrieval of the multiple peaks and subsequent image analysis. Here we describe and demonstrate a new implementation of a coupled phase retrieval technique for multi-peak BCDI which simultaneously treats each Bragg peak of the dataset and produces a three-dimensional image of the crystal's morphology and lattice distortion field. In addition, this method uses the redundant information contained in the various Bragg diffraction patterns to detect and suppress spurious signal appearing on the detector in a subset of the measurements. Compared with manual data editing, adaptive coupling produces a more consistent phase profile in reciprocal space and sharper surfaces in direct space, with no significant difference in computational cost. These improvements reduce the need for manual preprocessing and enable robust high-throughput analysis of multi-peak BCDI data, supporting near-real-time strain microscopy at modern synchrotron facilities.

36 MATERIALS SCIENCE↗

Mapping the gas density with the kinematic Sunyaev-Zel’dovich and patchy screening effects: A self-consistent comparison

The secondary anisotropies of the cosmic microwave background (CMB) provide a wealth of astrophysical and cosmological information. Pairing measurements of the CMB temperature map obtained by DR5 of the Atacama Cosmology Telescope (ACT) with the imaging survey conducted by the Dark Energy Spectroscopic Instrument for the purposes of target selection, DECaLS DR9, we investigate two effects that are sensitive to the gas density 𝜏: kinematic Sunyaev-Zel’dovich (kSZ) and patchy screening or anisotropic screening (resulting from the Thomson scattering of CMB photons away from the line-of-sight by free electrons). In particular, we measure the stacked profiles of the gas density around luminous red galaxies (LRGs) at a mean redshift of 𝑧 ≈ 0.7. We detect the kSZ signal at 7.2⁢𝜎, and we find a signal at ∼ 4.1⁢𝜎 for the patchy screening estimator, which is in excess relative to the kSZ signal. We attribute this excess to contamination from CMB lensing. Here, we demonstrate the effect of lensing using 𝑁-body simulations, and we show that the screening signal is dominated by it. Accounting for lensing, our measurement places a 95% upper bound on the optical depth of the Extended DESI LRG sample of 𝜏 < 2.5 10 −4 for a mean value of the sample of 𝜏 ≈ 1.6 10 −4 . Furthermore, via hydro simulations, we show that the underlying optical depth signal measured by both effects (after removing the CMB lensing contribution) is in perfect agreement when adopting either a compensated aperture photometry (CAP) filter or a high-pass filter. Consistent with previous measurements, we see evidence for excess baryonic feedback around DESI LRGs in the patchy screening measurement. In the future, when both effects can be measured with high signal-to-noise, one can measure the amplitude ratio between them, which is proportional to the root-mean-square velocity of the host halo sample, and even place constraints on velocity-sensitive models such as modified gravity and phantom dark energy.

Astrophysical & cosmological simulations↗

Determination of Scale Bar for AGHCF Metallography Data

The DOE Nuclear Energy Advanced Reactor Technologies (ART) Fast Reactor Program (FRP) has supported the development of several databases containing information on the safety performance of fast reactors, components, and fuels. This growing collection of legacy experimental data, operating data, and analysis is available online to registered users. Metallography data represents one of the most critical types of post-irradiation examination (PIE) data being collected, organized, and archived in several ART Fast Reactor Databases (https://frdb.ne.anl.gov), including the Metallic Fuels Irradiation & Physics Database (FIPD), Out-of-Pile Transient Database (OPTD), and TREAT (the Transient Reactor Test Facility) Experimental Relational Database (TREXR). These databases contain three principal sets of metallography data. The first set comprises metallography data from Experimental Breeder Reactor-II (EBR-II) and Fast Flux Test Facility (FFTF) irradiated fuel pins examined in the Hot Fuel Examination Facility (HFEF). The second set consists of metallography data from EBR-II irradiated fuel pins examined in the Alpha-Gamma Hot Cell Facility (AGHCF). The third set includes metallography data from transient-tested fuel pins (including both out-of-pile furnace tests and TREAT tests) examined in AGHCF. Since both the second and third sets were generated in AGHCF, they are governed by identical specifications. The metallography data in the databases consist of digital images scanned from either positive or negative photographic films. To analyze the microstructure of a fuel pin, a series of preparatory steps are required, including sectioning, epoxy mounting, mechanical grinding and polishing, and etching. Following sample preparation, specimens are transferred for metallographic examination. The AGHCF and HFEF metallography data were generated using optical microscopes manufactured by Leitz and Bausch and Lomb (B&L). Images were recorded on Polaroid film at preset magnifications. Magnification verification for the Leitz and B&L metallographs was conducted every two months prior to 1989 and at least every six months from 1989 through the conclusion of the IFR program. Magnifications determined from imaging of microslide standards were compared to the instrument settings for magnifications ranging from 50× to 500×. If the magnifications determined from standards deviated from the instrument settings, adjustments were made to the bellows extension until agreement was achieved. The specifications for AGHCF and HFEF legacy metallography data have been established based on available hard-copy and digital records, most of which have been incorporated into the data repositories associated with FIPD, OPTD, and TREXR. Detailed specifications including hard-copy records, digitized records, cutting diagrams and sectioning schemes, high-magnification photographs, photomosaics (composites), information tags, scale bars, and magnification verification procedures can be found in a separate report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Optical Test Bench (SYSM 5620 Final Report)

The National Ignition Facility (NIF) is a research facility that focuses on High Energy Density Science and Inertial Confinement Fusion. In the NIF, 192 laser beams are directed into a miniscule Target Capsule to generate an implosion – this is called a NIF Shot. Many NIF Users conduct experiments using different Targets and laser inputs to generate reactions that are of interest to the scientific community. Those reactions are monitored using various Target Diagnostic instruments, including Shot Time Photography – which provides crucial images of the Target as the implosion occurs. A subset of these NIF Users is less interested in the reaction itself and more interested in subjecting materials or devices to the intense environment that these reactions can create. Using the Target as a source of x-rays, neutrons, or blast loading for particular materials has been significant to the shock physics community and to those who work in extreme design spaces. However, the Material and Radiation Effects team – that performs these experiments on behalf of the NIF Users – has not been able to make good use of the existing Shot Time Photography Diagnostics. The STP cameras are focused on the Targets rather than the MRE Customers’ materials, the current system is not oriented to have a good view of the MRE Customers’ materials, and the cameras are limited in their capabilities (black and white, poor resolution, etc.). As MRE experiments increase in quantity and importance to the scientific community, the desire for visual monitoring of the experiments to substantiate models and inform other data is also rising.

42 ENGINEERING↗

Morgan State University Air Quality Monitor Field Campaign Report

This activity was to enable us to install air quality and meteorological instrumentation such as an automated Air Quality Drone, PurpleAir Sensor, and Sensit Ramp Air Quality Sensor. This installation formed part of the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Coast-Urban-Rural Atmospheric Gradient Experiment (CoURAGE) at the Baltimore site. Figure 1 shows the aerial image of the CoURAGE Baltimore site with all the installed instruments.

47 OTHER INSTRUMENTATION↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗