Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Beam Characterization at the Neutron Radiography Facility

The quality of a neutron imaging beam directly impacts the quality of radiographic images produced using that beam. Fully characterizing a neutron beam, including determination of the beam’s effective length-to-diameter ratio, neutron flux profile, energy spectrum, image quality, and beam divergence, is vital for producing quality radiographic images. This project characterized the east neutron imaging beamline at the Idaho National Laboratory Neutron Radiography Reactor (NRAD). The experiments which measured the beam’s effective length-to-diameter ratio and image quality are based on American Society for Testing and Materials (ASTM) standards. An analysis of the image produced by a calibrated phantom measured the beam divergence. The energy spectrum measurements consist of a series of foil irradiations using a selection of activation foils, compared to the results produced by a Monte Carlo n-Particle (MCNP) model of the beamline. Improvement of the existing NRAD MCNP beamline model includes validation of the model’s energy spectrum and the development of enhanced image simulation methods. The image simulation methods predict the radiographic image of an object based on the foil reaction rate data obtained by placing a model of the object in front of the image plane in an MCNP beamline model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Instrumental and observational requirements for space-based imaging of magnetospheric emissions

Simulated images of extreme ultraviolet (EUV) emissions from energetic outflowing ions have been constructed to study techniques for remotely sensing the dynamic behavior of hot plasmas in the near-Earth environment. These calculations include realistic assumptions about the energetic ion outflow from high latitudes and take into account the effects of cold plasmaspheric and ionospheric ions. The energetic ion outflow is determined from a statistical study based on five years of measurements from the Energetic Ion Composition Spectrometer on Dynamics Explorer 1. The simulated images change significantly with viewing geometry and certain spacecraft locations are clearly favorable for observing emissions from energetic ions. For example, for a near equatorial orbit, viewing locations greater than 9 Earth radii are required to observe outflowing ions above the cold plasmaspheric background. We will discuss other important considerations for magnetospheric imaging including the sensitivity requirements of the detector. In particular, we consider the performance of multi-layer optics for EUV wavelengths.

Robinson, R. M.↗

A comparison of digitally simulated holographic images with actual holographic images

In making digitally generated holograms the digital computer and its associated plotting equipment degrade the quality of the hologram. It is necessary then to study the computer generated hologram in terms of these degradations. A computer simulated optical processor allows the results to be observed via computer simulated images. This research reports a method for optimizing the computer image reconstruction and compares these images with optically produced holographic images. The versatility of the simulated optical processor is illustrated by several spatial filtering and hologram reconstructions.

Calhoun, M. D.↗

Realistic simulation of reduced-dose CT with noise modeling and sinogram synthesis using DICOM CT images

Purpose: Reducing the patient dose while maintaining the diagnostic image quality during CT exams is the subject of a growing number of studies, in which simulations of reduced-dose CT with patient data have been used as an effective technique when exploring the potential of various dose reduction techniques. Difficulties in accessing raw sinogram data, however, have restricted the use of this technique to a limited number of institutions. Here, we present a novel reduced-dose CT simulation technique which provides realistic low-dose images without the requirement of raw sinogram data. Methods: Two key characteristics of CT systems, the noise equivalent quanta (NEQ) and the algorithmic modulation transfer function (MTF), were measured for various combinations of object attenuation and tube currents by analyzing the noise power spectrum (NPS) of CT images obtained with a set of phantoms. Those measurements were used to develop a comprehensive CT noise model covering the reduced x-ray photon flux, object attenuation, system noise, and bow-tie filter, which was then employed to generate a simulated noise sinogram for the reduced-dose condition with the use of a synthetic sinogram generated from a reference CT image. The simulated noise sinogram was filtered with the algorithmic MTF and back-projected to create a noise CT image, which was then added to the reference CT image, finally providing a simulated reduced-dose CT image. The simulation performance was evaluated in terms of the degree of NPS similarity, the noise magnitude, the bow-tie filter effect, and the streak noise pattern at photon starvation sites with the set of phantom images. Results: The simulation results showed good agreement with actual low-dose CT images in terms of their visual appearance and in a quantitative evaluation test. The magnitude and shape of the NPS curves of the simulated low-dose images agreed well with those of real low-dose images, showing discrepancies of less than +/−3.2% in terms of the noise power at the peak height and +/−1.2% in terms of the spatial frequency at the peak height. The magnitudes of the noise measured for 12 different combinations the phantom size, tube current, and reconstruction kernel for the simulated and real low-dose images were very similar, with differences of 0.1 to 4.7%. Thep value for a statistical testing of the difference in the noise magnitude ranged from 0.99 to 0.11, showing that there was no difference statistically between the noise magnitudes of the real and simulated low-dose images using our method. The strength and pattern of the streak noise in an anthropomorphic phantom was also consistent with expectations. Conclusions: A novel reduced-dose CT simulation technique was developed which uses only CT images while not requiring raw sinogram data. Our method can provide realistic simulation results under reduced-dose conditions both in terms of the noise magnitude and the textual appearance. This technique has the potential to promote clinical research for patient dose reductions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging infrared: Scene simulation, modeling, and real image tracking; Proceedings of the Meeting, Orlando, FL, Mar. 30, 31, 1989

Various papers on scene simulation, modeling, and real image tracking using IR imaging are presented. Individual topics addressed include: tactical IR scene generator, dynamic FLIR simulation in flight training research, high-speed dynamic scene simulation in UV to IR spectra, development of an IR sensor calibration facility, IR celestial background scene description, transmission measurement of optical components at cryogenic temperatures, diffraction model for a point-source generator, silhouette-based tracking for tactical IR systems, use of knowledge in electrooptical trackers, detection and classification of target formations in IR image sequences, SMPRAD: simplified three-dimensional cloud radiance model, IR target generator, recent advances in testing of thermal imagers, generic IR system models with dynamic image generation, modeling realistic target acquisition using IR sensors in multiple-observer scenarios, and novel concept of scene generation and comprehensive dynamic sensor test.

Triplett, Milton J.↗

The Blending ToolKit: A simulation framework for evaluation of galaxy detection and deblending

We present an open source Python library for simulating overlapping (i.e., blended) images of galaxies and performing self-consistent comparisons of detection and deblending algorithms based on a suite of metrics. The package, named Blending Toolkit (BTK), serves as a modular, flexible, easy-to-install, and simple-to-use interface for exploring and analyzing systematic effects related to blended galaxies in cosmological surveys such as the Vera Rubin Observatory Legacy Survey of Space and Time (LSST). BTK has three main components: (1) a set of modules that perform fast image simulations of blended galaxies, using the open source image simulation package GalSim; (2) a module that standardizes the inputs and outputs of existing deblending algorithms; (3) a library of deblending metrics commonly defined in the galaxy deblending literature. In combination, these modules allow researchers to explore the impacts of galaxy blending in cosmological surveys. Additionally, BTK provides researchers who are developing a new deblending algorithm a framework to evaluate algorithm performance and make principled comparisons with existing deblenders. BTK includes a suite of tutorials and comprehensive documentation. The source code is publicly available on GitHub at https://github.com/LSSTDESC/BlendingToolKit.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo Radiative Transfer Modeling of Lightning Observed in Galileo Images of Jupiter

We study lightning on Jupiter and the clouds illuminated by the lightning using images taken by the Galileo orbiter. The Galileo images have a resolution of 25 km/pixel and axe able to resolve the shape of the single lightning spots in the images, which have full widths at half the maximum intensity in the range of 90-160 km. We compare the measured lightning flash images with simulated images produced by our ED Monte Carlo light-scattering model. The model calculates Monte Carlo scattering of photons in a ED opacity distribution. During each scattering event, light is partially absorbed. The new direction of the photon after scattering is chosen according to a Henyey-Greenstein phase function. An image from each direction is produced by accumulating photons emerging from the cloud in a small range (bins) of emission angles. Lightning bolts are modeled either as points or vertical lines. Our results suggest that some of the observed scattering patterns axe produced in a 3-D cloud rather than in a plane-parallel cloud layer. Lightning is estimated to occur at least as deep as the bottom of the expected water cloud. For the six cases studied, we find that the clouds above the lightning are optically thick (tau > 5). Jovian flashes are more regular and circular than the largest terrestrial flashes observed from space. On Jupiter there is nothing equivalent to the 30-40-km horizontal flashes which axe seen on Earth.

Dyudine, U. A.↗

Modeling Images and Spectra of a Solar Flare Observed by RHESSI on 20 February 2002

We have analyzed a C7.5 limb flare observed by RHESSI on 20 February 2002. The RHESSI images appear to show two footpoints and a loop-top source. Our goal was to determine if the data are consistent with a simple steady-state model in which high-energy electrons are continuously injected at the top of a semicircular flare loop. A comparison of the RHESSI images with simulated images from the model has made it possible for us to identify spurious sources and fluxes in the RHESSI images. We find the RHESSI results are in many aspects consistent with the model if a thermal source is included between the loop footpoints, but there is a problem with the spectral index of the loop-top source. The thermal source between the footpoints is likely to be a low-lying loop interacting with the northern footpoint of a higher loop containing the loop-top source.

Sui, Linhui↗

Monitoring of chlorin-based photosensitiser localisation with dual-wavelength fluorescence imaging: numerical simulations

An approach to the estimation of chlorin-based photosensitiser localisation with dual-wavelength fluorescence imaging after topical application or intravenous injection is developed based on numerical simulations. Fluorescence imaging, which is commonly used for the monitoring of photosensitiser distribution within tissue, does not allow for its depth-resolved imaging. Chlorin-based photosensitisers feature two peaks in their absorption spectra corresponding to 402 and 662 nm, which allows for fluorescence excitation at two wavelengths with significantly different light penetration depths into biotissues. The ratio of fluorescence signals detected upon irradiation at different excitation wavelengths is shown to provide the information about photosensitiser localisation. The cases of exponential in-depth decay of the photosensitiser concentration and uniform photosensitiser distribution within the layer at a certain depth within the medium are analysed. These cases simulate topical application of photosensitiser and its intravenous injection and further accumulation in tumour, respectively. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Resolution requirements for a soil moisture imaging radar

Image simulation techniques were employed to establish the relationship between spatial resolution and the accuracy of soil moisture estimated by an imaging radar. A spaceborne synthetic aperture radar at an orbital altitude of 600 km, operating at 4.5 GHz with HH polarization configuration and covering a ground swath width of 143 km corresponding to an angle of incidence range extending between 7-22 degrees relative to the vertical, provided the images simulated by a 17.7 km x 19.3 km test site. The role of resolution was evaluated by simulating various sets of images with resolutions ranging from 20 m x 20 m to 1 km x 1 km. Each simulated image was subjected to a soil moisture prediction algorithm whose input is limited to the image intensity level. Results show that the 1 km x 1 km resolution provides the best prediction accuracy for most soil moisture distributions except for drought-like conditions for which the 100 m x 100 m resolution is found to be preferred. In general it was found that the soil moisture of about 90% of the pixels is predicted with an error of + or - 20% of field capacity or less.

Dobson, C.↗

Frequency and Clinical Significance of Previously Undetected Incidental Findings Detected on Computed Tomography Simulation Scans for Breast Cancer Patients

Purpose: To determine the frequency and clinical significance of previously undetected incidental findings found on computed tomography (CT) simulation images for breast cancer patients. Methods and Materials: All CT simulation images were first interpreted prospectively by radiation oncologists and then double-checked by diagnostic radiologists. The official reports of CT simulation images for 881 consecutive postoperative breast cancer patients from 2009 to 2010 were retrospectively reviewed. Potentially important incidental findings (PIIFs) were defined as any previously undetected benign or malignancy-related findings requiring further medical follow-up or investigation. For all patients in whom a PIIF was detected, we reviewed the clinical records to determine the clinical significance of the PIIF. If the findings from the additional studies prompted by a PIIF required a change in management, the PIIF was also recorded as a clinically important incidental finding (CIIF). Results: There were a total of 57 (6%) PIIFs. The 57 patients in whom a PIIF was detected were followed for a median of 17 months (range, 3-26). Six cases of CIIFs (0.7% of total) were detected. Of the six CIIFs, three (50%) cases had not been noted by the radiation oncologist until the diagnostic radiologist detected the finding. On multivariate analysis, previous CT examination was an independent predictor for PIIF (p = 0.04). Patients who had not previously received chest CT examinations within 1 year had a statistically significantly higher risk of PIIF than those who had received CT examinations within 6 months (odds ratio, 3.54; 95% confidence interval, 1.32-9.50; p = 0.01). Conclusions: The rate of incidental findings prompting a change in management was low. However, radiation oncologists appear to have some difficulty in detecting incidental findings that require a change in management. Considering cost, it may be reasonable that routine interpretations are given to those who have not received previous chest CT examinations within 1 year.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-pressure phase transition in 3-D printed nanolamellar high-entropy alloy by imaging and simulation insights

Abstract We report on the high-resolution imaging and molecular dynamics simulations of a 3D-printed eutectic high-entropy alloy (EHEA) Ni 40 Co 20 Fe 10 Cr 10 Al 18 W 2 consisting of nanolamellar BCC and FCC phases. The direct lattice imaging of 3D-printed samples shows the Kurdjumov–Sachs (K–S) orientation relation {111} FCC parallel to {110} BCC planes in the dual-phase lamellae. Unlike traditional iron and steels, this alloy shows an irreversible BCC-to-FCC phase transformation under high pressures. The nanolamellar morphology is maintained after pressure cycling to 30 GPa, and nano-diffraction studies show both layers to be in the FCC phase. The chemical compositions of the dual-phase lamellae after pressure recovery remain unchanged, suggesting a diffusion-less BCC–FCC transformation in this EHEA. The lattice imaging of the pressure-recovered sample does not show any specific orientation relation between the two resulting FCC phases, indicating that many grain orientations are produced during the BCC–FCC phase transformation. Molecular dynamics simulations on phase transformation in a nanolamellar BCC/FCC in K–S orientation show that phase transformation from BCC to FCC is completed under high pressures, and the FCC phase is retained on decompression aided by the stable interfaces. Our work elucidates the irreversible phase transformation under static compression, providing an understanding of the orientation relationships in 3-D printed EHEA under high pressures.

3-D Printing↗

Quantitative Analysis of HAADF–STEM Images of MoVTeTaO M1 Phase Catalyst for Propane Ammoxidation to Acrylonitrile

Abstract High‐angle annular dark‐field scanning transmission electron microscopy (HAADF–STEM) image simulations were performed to determine accurate metal distributions in the MoVTeTaO M1 phase catalyst for propane ammoxidation. QSTEM simulation, based on a multislice method with the frozen phonon approximation, was chosen because of the excellent agreement between experimental and simulated HAADF–STEM images. This simulation method successfully provided accurate metal distributions in the MoVTeTaO M1 phase and indicated significantly lower V occupancies of the linking sites 1, 2, 3, 4, and 7, and higher Ta occupancy in site 9 than the previously reported metal occupancies. This novel methodology for accurate HAADF–STEM image analysis is a valuable tool for accurate analysis of local chemical compositions in a wide range of ordered catalytic materials.

Woo, Jungwon↗

Biological Visualization, Imaging and Simulation(Bio-VIS) at NASA Ames Research Center: Developing New Software and Technology for Astronaut Training and Biology Research in Space

The Bio- Visualization, Imaging and Simulation (BioVIS) Technology Center at NASA's Ames Research Center is dedicated to developing and applying advanced visualization, computation and simulation technologies to support NASA Space Life Sciences research and the objectives of the Fundamental Biology Program. Research ranges from high resolution 3D cell imaging and structure analysis, virtual environment simulation of fine sensory-motor tasks, computational neuroscience and biophysics to biomedical/clinical applications. Computer simulation research focuses on the development of advanced computational tools for astronaut training and education. Virtual Reality (VR) and Virtual Environment (VE) simulation systems have become important training tools in many fields from flight simulation to, more recently, surgical simulation. The type and quality of training provided by these computer-based tools ranges widely, but the value of real-time VE computer simulation as a method of preparing individuals for real-world tasks is well established. Astronauts routinely use VE systems for various training tasks, including Space Shuttle landings, robot arm manipulations and extravehicular activities (space walks). Currently, there are no VE systems to train astronauts for basic and applied research experiments which are an important part of many missions. The Virtual Glovebox (VGX) is a prototype VE system for real-time physically-based simulation of the Life Sciences Glovebox where astronauts will perform many complex tasks supporting research experiments aboard the International Space Station. The VGX consists of a physical display system utilizing duel LCD projectors and circular polarization to produce a desktop-sized 3D virtual workspace. Physically-based modeling tools (Arachi Inc.) provide real-time collision detection, rigid body dynamics, physical properties and force-based controls for objects. The human-computer interface consists of two magnetic tracking devices (Ascention Inc.) attached to instrumented gloves (Immersion Inc.) which co-locate the user's hands with hand/forearm representations in the virtual workspace. Force-feedback is possible in a work volume defined by a Phantom Desktop device (SensAble inc.). Graphics are written in OpenGL. The system runs on a 2.2 GHz Pentium 4 PC. The prototype VGX provides astronauts and support personnel with a real-time physically-based VE system to simulate basic research tasks both on Earth and in the microgravity of Space. The immersive virtual environment of the VGX also makes it a useful tool for virtual engineering applications including CAD development, procedure design and simulation of human-system systems in a desktop-sized work volume.

Smith, Jeffrey↗

SU-E-J-89: Comparative Analysis of MIM and Velocity’s Image Deformation Algorithm Using Simulated KV-CBCT Images for Quality Assurance

Purpose: Deformable image registration (DIR) is used routinely in the clinic without a formalized quality assurance (QA) process. Using simulated deformations to digitally deform images in a known way and comparing to DIR algorithm predictions is a powerful technique for DIR QA. This technique must also simulate realistic image noise and artifacts, especially between modalities. This study developed an algorithm to create simulated daily kV cone-beam computed-tomography (CBCT) images from CT images for DIR QA between these modalities. Methods: A Catphan and physical head-and-neck phantom, with known deformations, were used. CT and kV-CBCT images of the Catphan were utilized to characterize the changes in Hounsfield units, noise, and image cupping that occur between these imaging modalities. The algorithm then imprinted these changes onto a CT image of the deformed head-and-neck phantom, thereby creating a simulated-CBCT image. CT and kV-CBCT images of the undeformed and deformed head-and-neck phantom were also acquired. The Velocity and MIM DIR algorithms were applied between the undeformed CT image and each of the deformed CT, CBCT, and simulated-CBCT images to obtain predicted deformations. The error between the known and predicted deformations was used as a metric to evaluate the quality of the simulated-CBCT image. Ideally, the simulated-CBCT image registration would produce the same accuracy as the deformed CBCT image registration. Results: For Velocity, the mean error was 1.4 mm for the CT-CT registration, 1.7 mm for the CT-CBCT registration, and 1.4 mm for the CT-simulated-CBCT registration. These same numbers were 1.5, 4.5, and 5.9 mm, respectively, for MIM. Conclusion: All cases produced similar accuracy for Velocity. MIM produced similar values of accuracy for CT-CT registration, but was not as accurate for CT-CBCT registrations. The MIM simulated-CBCT registration followed this same trend, but overestimated MIM DIR errors relative to the CT-CBCT registration.

60 APPLIED LIFE SCIENCES↗

TU-H-CAMPUS-IeP1-01: Bias and Computational Efficiency of Variance Reduction Methods for the Monte Carlo Simulation of Imaging Detectors

Purpose: Variance reduction techniques (VRTs) are employed in Monte Carlo simulations to obtain estimates with reduced statistical uncertainty for a given simulation time. In this work, we study the bias and efficiency of a VRT for estimating the response of imaging detectors. Methods: We implemented Directed Sampling (DS), preferentially directing a fraction of emitted optical photons directly towards the detector by altering the isotropic model. The weight of each optical photon is appropriately modified to maintain simulation estimates unbiased. We use a Monte Carlo tool called fastDETECT2 (part of the hybridMANTIS open-source package) for optical transport, modified for VRT. The weight of each photon is calculated as the ratio of original probability (no VRT) and the new probability for a particular direction. For our analysis of bias and efficiency, we use pulse height spectra, point response functions, and Swank factors. We obtain results for a variety of cases including analog (no VRT, isotropic distribution), and DS with 0.2 and 0.8 optical photons directed towards the sensor plane. We used 10,000, 25-keV primaries. Results: The Swank factor for all cases in our simplified model converged fast (within the first 100 primaries) to a stable value of 0.9. The root mean square error per pixel for DS VRT for the point response function between analog and VRT cases was approximately 5e-4. Conclusion: Our preliminary results suggest that DS VRT does not affect the estimate of the mean for the Swank factor. Our findings indicate that it may be possible to design VRTs for imaging detector simulations to increase computational efficiency without introducing bias.

60 APPLIED LIFE SCIENCES↗

Atomic Scale Studies of La/Sr Ordering in Colossal Magnetoresistant La 2-2x Sr 1+2x Mn 2 O 7 Single Crystals

To date, it is unclear whether chemical order (or disorder) is in any way connected to double exchange, electronic phase separation, or charge ordering (CO) in manganites. In this work, we carry out an atomic resolution study of the colossal magnetoresistant manganite La 2-2x Sr 1+2x Mn 2 O 7 (LSMO). We combine aberration-corrected electron microscopy and spectroscopy with spectroscopic image simulations, to analyze cation ordering at the atomic scale in real space in a number of LSMO single crystals. We compare three different compositions within the phase diagram: a ferromagnetic metallic material (x=0.36), an insulating, antiferromagnetic charge ordered (AF-CO) compound (x=0.5), which also exhibits orbital ordering, and an additional AF sample (x=0.56). Detailed image simulations are essential to accurately quantify the degree of chemical ordering of these samples. We find a significant degree of long-range chemical ordering in all cases, which increases in the AF-CO range. However, the degree of ordering is never complete nor can it explain the strongly correlated underlying ordering phenomena. Our results show that chemical ordering over distinct crystallographic sites is not needed for electronic ordering phenomena to appear in manganites, and cannot by itself explain the complex electronic behavior of LSMO.

36 MATERIALS SCIENCE↗

Geological terrain models

The initial phase of a program to determine the best interpretation strategy and sensor configuration for a radar remote sensing system for geologic applications is discussed. In this phase, terrain modeling and radar image simulation were used to perform parametric sensitivity studies. A relatively simple computer-generated terrain model is presented, and the data base, backscatter file, and transfer function for digital image simulation are described. Sets of images are presented that simulate the results obtained with an X-band radar from an altitude of 800 km and at three different terrain-illumination angles. The simulations include power maps, slant-range images, ground-range images, and ground-range images with statistical noise incorporated. It is concluded that digital image simulation and computer modeling provide cost-effective methods for evaluating terrain variations and sensor parameter changes, for predicting results, and for defining optimum sensor parameters.

Kaupp, V. H.↗