Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image retrieval”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fidelity-preserving enhancement of ptychography with foundational text-to-image models

Ptychographic phase retrieval enables high-resolution imaging of complex samples but often suffers from artifacts such as grid pathology and multislice crosstalk, which degrade reconstructed images. We propose a plug-and-play (PnP) framework that integrates physics model-based phase retrieval with text-guided image editing using foundational diffusion models. By employing the alternating direction method of multipliers, our approach ensures consensus between data fidelity and artifact removal subproblems, maintaining physical consistency while enhancing image quality. Artifact removal is achieved using a text-guided diffusion image editing method (LEDITS++) with a pre-trained foundational diffusion model, allowing users to specify artifacts for removal in natural language. Demonstrations on simulated and experimental datasets show significant improvements in artifact suppression and structural fidelity, validated by metrics such as peak signal-to-noise ratio and diffraction pattern consistency. This work highlights the combination of text-guided generative models and model-based phase retrieval algorithms as a transferable and fidelity-preserving method for high-quality diffraction imaging.

image editing↗

Using DSCOVR EPIC as a Transfer Radiometer to Scale Multiple VIIRS Sensors Over Tropical Earth Views

The NASA CERES project provides Energy Balanced and Filled (EBAF) product climate-quality observed TOA and computed surface fluxes to the climate community. The CERES instruments are on board the Terra, Aqua, Suomi-NPP, and NOAA-20 satellites. The CERES project radiometrically scales the MODIS and VIIRS imager visible channel radiances to the Aqua- MODIS reference to retrieve consistent imager cloud properties between sensors, which are used to retrieve cloud properties required for converting CERES radiance observations into fluxes. The NPP, NOAA-20, and the future NOAA-21 VIIRS imagers will be in the same sun- synchronous orbit but spaced equally apart, which means that no simultaneous nadir overpasses (SNO) may be used to inter-calibrate the VIIRS imagers to each one another. Currently, the CERES project uses Aqua-MODIS to radiometrically scale between VIIRS imagers. Once the Terra and Aqua satellites start drifting toward the terminator, Aqua-MODIS can no longer be utilized as the transfer radiometer between VIIRS sensors and there will be no SNOs in common between either MODIS and or VIIRS imagers. The DSCOVR satellite orbits the Lagrange-1 (L1) point about 1.5 million kilometers from Earth. The Earth Polychromatic Imaging Camera (EPIC) instrument on the Earth-facing side of DSCOVR takes images ranging from the UV to the NIR of the sunlit side of the Earth. While the EPIC sensor has no onboard calibration systems, multiple inter-calibration studies have indicated that the EPIC instrument response is radiometrically stable. The stability of the EPIC instrument allows it to be used as a transfer radiometer between all MODIS and VIIRS imagers and is especially suited for drifting orbits because EPIC imager frequently samples the Earth diurnally. The study will demonstrate the use of EPIC as a transfer radiometer to radiometrically scale the NPP and NOAA-20 VIIRS imagers. The scaling factors will be compared with the scaling factors using Aqua-MODIS as the transfer radiometer.

Conor Haney↗

Is the bang worth the buck? A RAID performance study

Expecting a high data delivery rate as well as data protection, the Lister Hill National Center for Biomedical Communications procured a RAID system to house image files for image delivery applications. A study was undertaken to determine the configuration of the RAID system that would provide for the fastest retrieval of image files. Average retrieval times with single and with concurrent users were measured for several stripe widths and several numbers of disks for RAID levels 0, 0+1 and 5. These are compared to each other and to average retrieval times for non-RAID configurations of the same hardware. Although the study in ongoing, a few conclusions have emerged regarding the tradeoffs among the different configurations with respect to file retrieval speed and cost.

Hauser, Susan E.↗

Reconstruction of simulated electrostatic potentials by automatic differentiation-based phase retrieval in electron microscopy imaging

Measuring interfacial electrostatic potentials is vital to understanding many fundamental materials properties. A variety of TEM methods exist for measuring electric potentials from the phase shift produced on an electron wave as it passes through a sample. However, most are either experimentally challenging or poorly suited to resolving nanoscale features. Here, we demonstrate the viability of a simple, automatic differentiation-based exit wave reconstruction from a focal series of images to accurately measure nanoscale electric potentials. Here, the analysis suggests that under optimal measurement conditions, electric potentials can be resolved to less than 0.06 V in magnitude and less than 1 nm in spatial extent.

36 MATERIALS SCIENCE↗

Uncertainty of Passive Imager Cloud Optical Property Retrievals to Instrument Radiometry and Model Assumptions: Examples from MODIS

The optical and microphysical structure of clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS on the NASA EOS Terra and Aqua platforms, simultaneous global-daily 1 km retrievals of cloud optical thickness (COT) and effective particle radius (CER) are provided, as well as the derived water path (WP). The cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate retrieval datasets for various two-channel retrievals, typically a VISNIR channel paired with a 1.6, 2.1, and 3.7 m spectral channel. The MOD06 forward model is derived from on a homogeneous plane-parallel cloud. In Collection 5 processing (completed in 2007 with a modified Collection 5.1 completed in 2010), pixel-level retrieval uncertainties were calculated for the following non-3-D error sources: radiometry, surface spectral albedo, and atmospheric corrections associated with model analysis uncertainties (water vapor only). The latter error source includes error correlation across the retrieval spectral channels. Estimates of uncertainty in 1 aggregated (Level-3) means were also provided assuming unity correlation between error sources for all pixels in a grid for a single day, and zero correlation of error sources from one day to the next. I n Collection 6 (expected to begin in late summer 2013) we expanded the uncertainty analysis to include: (a) scene-dependent calibration uncertainty that depends on new band and detector-specific Level 1B uncertainties, (b) new model error sources derived from the look-up tables which includes sensitivities associated with wind direction over the ocean and uncertainties in liquid water and ice effective variance, (c) thermal emission uncertainties in the 3.7 m band associated with cloud and surface temperatures that are needed to extract reflected solar radiation from the total radiance signal, (d) uncertainty in the solar spectral irradiance at 3.7 m, and (e) addition of stratospheric ozone uncertainty in visible atmospheric corrections. A summary of the approach and example Collection 6 results will be shown.

Cloud Properties Observations↗

Ground-based Validation of the EOS Multi-angle Imaging SpectroRadiometer (MISR) Aerosol Retrieval Algorithms and Science Data Products

A plan for the ground-based validation of MISR aerosol retrieval is outlined. Activities occur in two phases: (1) pre-launch, work is focused on technique development and MISR algorithm validation using conventional ground-base methods and a MISR simulator (AirMISR) operating from the ER-2 aircraft to simulate MISR on-orbit observations. (2) Post-launch, the validation program relies on ground campaigns, underflights wit the MISR simulator and the use of local measurements fo aerosol loading and properties and irradiance measurements derived from the AERONET and ISIS networks.

algorithm↗

Variable Sampling Mapping

The performance of an optical system (for example, a telescope) is limited by the misalignments and manufacturing imperfections of the optical elements in the system. The impact of these misalignments and imperfections can be quantified by the phase variations imparted on light traveling through the system. Phase retrieval is a methodology for determining these variations. Phase retrieval uses images taken with the optical system and using a light source of known shape and characteristics. Unlike interferometric methods, which require an optical reference for comparison, and unlike Shack-Hartmann wavefront sensors that require special optical hardware at the optical system's exit pupil, phase retrieval is an in situ, image-based method for determining the phase variations of light at the system s exit pupil. Phase retrieval can be used both as an optical metrology tool (during fabrication of optical surfaces and assembly of optical systems) and as a sensor used in active, closed-loop control of an optical system, to optimize performance. One class of phase-retrieval algorithms is the iterative transform algorithm (ITA). ITAs estimate the phase variations by iteratively enforcing known constraints in the exit pupil and at the detector, determined from modeled or measured data. The Variable Sampling Mapping (VSM) technique is a new method for enforcing these constraints in ITAs. VSM is an open framework for addressing a wide range of issues that have previously been considered detrimental to high-accuracy phase retrieval, including undersampled images, broadband illumination, images taken at or near best focus, chromatic aberrations, jitter or vibration of the optical system or detector, and dead or noisy detector pixels. The VSM is a model-to-data mapping procedure. In VSM, fully sampled electric fields at multiple wavelengths are modeled inside the phase-retrieval algorithm, and then these fields are mapped to intensities on the light detector, using the properties of the detector and optical system, for comparison with measured data. Ultimately, this model-to-data mapping procedure enables a more robust and accurate way of incorporating the exit-pupil and image detector constraints, which are fundamental to the general class of ITA phase retrieval algorithms.

Smith, Jeffrey, S.↗

On the use of DSCOVR EPIC to monitor the visible calibration stability of polar orbiting imagers to improve the next edition of the CERES climate data record.

The NASA CERES project has provided the climate quality observed TOA and computed surface fluxes to the scientific community. CERES instruments are onboard the Terra, Aqua, NPP, and NOAA-20 spacecraft. CERES uses MODIS and VIIRS imagers to retrieve cloud properties needed to convert CERES footprint radiance observations into fluxes using empirically derived angular directional models obtained during early CERES record. CERES utilizes geostationary sensors to infer the regional diurnal fluxes in between Terra and Aqua CERES observations. The imagers are also used to radiometrically scale the geostationary sensors (GEO) radiances to the imager calibration reference to ensure that the GEO derived cloud properties and broadband TOA fluxes are consistent in both space and time. Both the imager and GEO retrieved cloud properties are used to compute the surface fluxes. The Aqua-MODIS, SNPP-VIIRS, and NOAA-20 VIIRS afternoon imagers will also need to be radiometrically scaled to the same common calibration reference. Although all three imagers employ onboard solar diffusers, the calibration is not consistent over time due to instrument anomalies and ageing of the onboard calibrators. The CERES imager and GEO calibration group (IGCG) has been tasked to remove the imager channel calibration drifts for the next CERES reprocessing effort. The team will rely primarily on deep convective clouds, desert, and polar ice invariant targets to monitor the imager channel stability. The team uses ray-matched radiance pairs to radiometrically scale the SNPP and NOAA-20 VIIRS sensors to Aqua-MODIS. The radiometric scaling is further validated using geostationary imagers as transfer radiometers. The DSCOVR satellite was launched on February 25, 2015 and orbits around the L1 Lagrange point directly between the Earth and the sun. The EPIC instrument onboard DSCOVR employs a CCD array to image the Earth approximately every 2-hours. The EPIC sensor contains no onboard calibration systems. However, multiple inter-calibration studies have shown that the EPIC imager is very stable in time. This is likely due to the DSCOVR satellite being located about a 1.5M km from the Earth, where very little Earth reflected solar radiation degrades the optics. The excellent radiometric stability of EPIC allows the CERES IGCG to utilize the EPIC observations as a stable reference for monitoring the calibration stability of the three afternoon imagers, as well as to validate the radiometric scaling factors between them. Examples of the imager relative calibration using EPIC before and after radiometric scaling will be shown along with the results from the use of invariant targets to remove imager calibration drifts.

DSCOVR-EPIC↗

A Method for Retrieving Ground Flash Fraction from Satellite Lightning Imager Data

A general theory for retrieving the fraction of ground flashes in N lightning observed by a satellite-based lightning imager is provided. An "exponential model" is applied as a physically reasonable constraint to describe the measured optical parameter distributions, and population statistics (i.e., mean, variance) are invoked to add additional constraints to the retrieval process. The retrieval itself is expressed in terms of a Bayesian inference, and the Maximum A Posteriori (MAP) solution is obtained. The approach is tested by performing simulated retrievals, and retrieval error statistics are provided. The ability to retrieve ground flash fraction has important benefits to the atmospheric chemistry community. For example, using the method to partition the existing satellite global lightning climatology into separate ground and cloud flash climatologies will improve estimates of lightning nitrogen oxides (NOx) production; this in turn will improve both regional air quality and global chemistry/climate model predictions.

Koshak, William J.↗

High-Resolution Imaging of Unstained Polymer Materials

Electron microscopy has played an important role in polymer characterization. Traditionally, electron diffraction is used to study crystalline polymers while transmission electron microscopy is used to study microphase separation in stained block copolymers and other multiphase systems. We describe developments that eliminate the barrier between these two approaches - it is now possible to image polymer crystals with atomic resolution. The focus of this Review is on high-resolution imaging (30 Å and smaller) of unstained polymers. Recent advances in hardware allow for capturing numerous (as many as 105) low-dose images from an unperturbed specimen; beam damage is a significant barrier to high-resolution electron microscopy of polymers. Machine-learning-based software is then used to sort and average the images to retrieve pristine structural information from a collection of noisy images. Acknowledging the heterogeneity in polymer samples prior to averaging is essential. Molecular conformations in a wide range of amphiphilic block copolymers, polymerized ionic liquids, and conjugated polymers can be gleaned from two-dimensional projections (2D), three-dimensional (3D) tomograms, and four-dimensional (4D) scanning transmission electron microscopy (STEM) data sets where 2D diffraction patterns are taken as a function of position. Some methods such as phase contrast STEM have been used to image closely related materials such as metal-organic frameworks but not polymers. With improvements in hardware and software, such methods may soon be applied to polymers. Our goal is to provide a comprehensive understanding of the strategies toward the high-resolution imaging of radiation sensitive polymer materials at different length scales.

36 MATERIALS SCIENCE↗

Optimized retrievals of precipitable water fields from combinations of VAS satellite and conventional surface observations

VISSR (visible and infrared spin-scan radiometer) atmospheric sounder (VAS) radiances and conventional surface temperature and dewpoint data are used in several combinations within a regression approach to determine the optimum resolution and accuracy of precipitable water (PW) fields retrieved from satellite observations. Point retrievals at radiosonde stations are used to determine the numerical accuracy of each retrieval technique, and image sequences of the retrieved PW fields are used to determine the temporal stability and spatial coherence of mesoscale PW features. VAS channels 5, 6, 7, and 8 and the surface dewpoint contribute the most information to regression-based retrievals of PW. The most accurate PW retrievals are obtained when radiances are averaged to a resolution of 15 to 60 km. A physical 'split-window' approach provides better PW estimates than regression when only the 11- and 12-micron VAS channels are available or when radiosonde-based training is limited to only one time period.

Robinson, W. D.↗

yourSky: Custom Sky-Image Mosaics via the Internet

yourSky (http://yourSky.jpl.nasa.gov) is a computer program that supplies custom astronomical image mosaics of sky regions specified by requesters using client computers connected to the Internet. [yourSky is an upgraded version of the software reported in Software for Generating Mosaics of Astronomical Images (NPO-21121), NASA Tech Briefs, Vol. 25, No. 4 (April 2001), page 16a.] A requester no longer has to engage in the tedious process of determining what subset of images is needed, nor even to know how the images are indexed in image archives. Instead, in response to a requester s specification of the size and location of the sky area, (and optionally of the desired set and type of data, resolution, coordinate system, projection, and image format), yourSky automatically retrieves the component image data from archives totaling tens of terabytes stored on computer tape and disk drives at multiple sites and assembles the component images into a mosaic image by use of a high-performance parallel code. yourSky runs on the server computer where the mosaics are assembled. Because yourSky includes a Web-interface component, no special client software is needed: ordinary Web browser software is sufficient.

Jacob, Joseph↗

Space Images for NASA/JPL

Space Images for NASA/JPL is an Apple iPhone application that allows the general public to access featured images from the Jet Propulsion Laboratory (JPL). A back-end infrastructure stores, tracks, and retrieves space images from the JPL Photojournal Web server, and catalogs the information into a streamlined rating infrastructure.

Boggs, Karen↗

Land Surface Temperature Measurements from EOD MODIS Data

We made more tests of the version 2.0 daily Level 2 and Level 3 Land-Surface Temperature (LST) code (PGE 16) jointly with the MODIS Science Data Support Team (SDST). After making minor changes a few times, the PGE16 code has been successfully integrated and tested by MODIS SDST, and recently has passed the inspection at the Goddard Distributed Active Archive Center (DAAC). We conducted a field campaign in the area of Mono Lake, California on March 10, 1998, in order to validate the MODIS LST algorithm in cold and dry conditions. Two MODIS Airborne Simulator (MAS) flights were completed during the field campaign, one before noon, and another around 10 pm PST. The weather condition for the daytime flight was perfect: clear sky, the column water vapor measured by radiosonde around 0.3 cm, and wind speed less than a half meter per second. The quality of MAS data is good for both day and night flights. We analyzed the noise equivalent temperature difference (NE(delta)T) and the calibration accuracy of the seven MAS thermal infrared (TIR) bands, that are used in the MODIS day/night LST algorithm, with daytime MAS data over four flat homogeneous study areas: two on Grant Lake (covered with ice and snow, respectively), one on Mono Lake, and another on the snow field site where we made field measurements. NE(delta)T ranges from 0.2 to 0.6 k for bands 42, 45, 46, and 48. It ranges from 0.8 to 1.1 K for bands 30-32. The day and night MAS data have been used to retrieve surface temperature and emissivities in these bands. A simple method to correct the effect of night thin cirrus has been incorporated into the day/night LST algorithm in dry atmospheric conditions. We compared the retrieved surface temperatures with those measured with TIR spectrometer, radiometers and thermistors in the snow test site, and the retrieved emissivity images with topographic map. The daytime LST values match well within 1 K. The night LST retrieved from MAS data is 3.3 K colder than those from field measurements most likely because of the effect of haze at night. The good agreement among the regional averaged surface temperatures obtained from LST values retrieved at different resolutions increased our confidence in the MODIS day/night LST algorithm.

Wan, Zheng-Ming↗

Image databases: Problems and perspectives

With the increasing number of computer graphics, image processing, and pattern recognition applications, economical storage, efficient representation and manipulation, and powerful and flexible query languages for retrieval of image data are of paramount importance. These and related issues pertinent to image data bases are examined.

Gudivada, V. Naidu↗

General approaches for shear-correcting coordinate transformations in Bragg coherent diffraction imaging. Part II

X-ray Bragg coherent diffraction imaging (BCDI) has been demonstrated as a powerful 3D microscopy approach for the investigation of sub-micrometre-scale crystalline particles. The approach is based on the measurement of a series of coherent Bragg diffraction intensity patterns that are numerically inverted to retrieve an image of the spatial distribution of the relative phase and amplitude of the Bragg structure factor of the diffracting sample. This 3D information, which is collected through an angular rotation of the sample, is necessarily obtained in a non-orthogonal frame in Fourier space that must be eventually reconciled. To deal with this, the approach currently favored by practitioners (detailed in Part I) is to perform the entire inversion in conjugate non-orthogonal real- and Fourier-space frames, and to transform the 3D sample image into an orthogonal frame as a post-processing step for result analysis. In this article, which is a direct follow-up of Part I, two different transformation strategies are demonstrated, which enable the entire inversion procedure of the measured data set to be performed in an orthogonal frame. The new approaches described here build mathematical and numerical frameworks that apply to the cases of evenly and non-evenly sampled data along the direction of sample rotation ( i.e. the rocking curve). The value of these methods is that they rely on the experimental geometry, and they incorporate significantly more information about that geometry into the design of the phase-retrieval Fourier transformation than the strategy presented in Part I. Finally, two important outcomes are (1) that the resulting sample image is correctly interpreted in a shear-free frame and (2) physically realistic constraints of BCDI phase retrieval that are difficult to implement with current methods are easily incorporated. Computing scripts are also given to aid readers in the implementation of the proposed formalisms.

36 MATERIALS SCIENCE↗