Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image denoising”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

81 records · Page 5

DR-RINS: Digital real-time relative intensity noise suppressor for pump–probe spectroscopy and microscopy

Relative intensity noise (RIN) inherent in fiber lasers poses a serious obstacle to their use in pump–probe spectroscopy and imaging. RIN can be removed through an analog balanced detector, or, as we have previously shown, software adaptive noise cancellation (ANC) on digitized signals. One major drawback to software ANC is the added time required for digitizing and post-processing. In this article, we describe a design for ANC on a field-programmable gate array (FPGA), making use of high-level synthesis tools and fixed-point arithmetic to achieve real-time laser RIN suppression at 25 MHz sample rates. Unlike the software-ANC approach, the FPGA-ANC device can serve as a dedicated drop-in denoiser, placed between the detectors and a commercial lock-in amplifier. We demonstrate its application to transient absorption spectroscopy and microscopy, lowering the noise floor to ~17 dB above the shot noise limit. Furthermore, we demonstrate a dramatic improvement in data acquisition time from ~6 h to ~5 min in a real-time imaging scenario.

47 OTHER INSTRUMENTATION↗

Joint ptycho-tomography with deep generative priors

Abstract Joint ptycho-tomography is a powerful computational imaging framework to recover the refractive properties of a 3D object while relaxing the requirements for probe overlap that is common in conventional phase retrieval. We use an augmented Lagrangian scheme for formulating the constrained optimization problem and employ an alternating direction method of multipliers (ADMM) for the joint solution. ADMM allows the problem to be split into smaller and computationally more efficient subproblems: ptychographic phase retrieval, tomographic reconstruction, and regularization of the solution. We extend our ADMM framework with plug-and-play (PnP) denoisers by replacing the regularization subproblem with a general denoising operator based on machine learning. While the PnP framework enables integrating such learned priors as denoising operators, tuning of the denoiser prior remains challenging. To overcome this challenge, we propose a denoiser parameter to control the effect of the denoiser and to accelerate the solution. In our simulations, we demonstrate that our proposed framework with parameter tuning and learned priors generates high-quality reconstructions under limited and noisy measurement data.

97 MATHEMATICS AND COMPUTING↗

Advancing the Limits of InSAR to Detect Crustal Displacement from Low-Magnitude Earthquakes through Deep Learning

Detecting surface deformation associated with low-magnitude (M w ≤ 5) seismicity using interferometric synthetic aperture radar (InSAR) is challenging due to the subtlety of the signal and the often challenging imaging environments. However, low-magnitude earthquakes are potential precursors to larger seismic events, and thus characterizing the crustal displacement associated with them is crucial for regional seismic hazard assessment. We combine InSAR time-series techniques with a Deep Learning (DL) autoencoder denoiser to detect the magnitude and extent of crustal deformation from the M w = 3.4 Gallina, New Mexico earthquake that occurred on 30 July 2020. Although InSAR alone cannot detect event-related deformation from such a low-magnitude seismic event, application of the DL method reveals maximum displacements as small as (±2.5 mm) in the vicinity of both the fault and earthquake epicenter without prior knowledge of the fault system. This finding improves small-scale displacement discernment with InSAR by an order of magnitude relative to previous studies. We additionally estimate best-fitting fault parameters associated with the observed deformation. The application of the DL technique unlocks the potential for low-magnitude earthquake studies, providing new insights into local fault geometries and potential risks from higher-magnitude earthquakes. This technique also permits low-magnitude event monitoring in areas where seismic networks are sparse, allowing for the possibility of global fault deformation monitoring.

58 GEOSCIENCES↗

Regularization by denoising diffusion models for solving inverse PDE problems with application to full waveform inversion

Partial differential equation (PDE)-governed inverse problems are fundamental across various scientific and engineering applications; yet they face significant challenges due to nonlinearity, ill-posedness, and sensitivity to noise. Here, we introduce a computational framework, regularization by denoising using diffusion models for partial differential equations (RED-DiffEq), by integrating physics-driven inversion and data-driven learning. RED-DiffEq leverages pretrained diffusion models as a regularization mechanism for PDE-governed inverse problems. We apply RED-DiffEq to solve the full waveform inversion problem in geophysics, a challenging seismic imaging technique that seeks to reconstruct high-resolution subsurface velocity models from seismic measurement data. Our method shows enhanced accuracy and robustness compared to benchmark methods. Additionally, it exhibits strong generalization and domain decomposition capacity, enabling the inversion of more complex velocity models with larger domains than those used in training the diffusion model. Our framework can also be directly applied to diverse PDE-governed inverse problems.

Shan, Siming [Yale University, New Haven, CT (Unit↗

Physics-driven learning of Wasserstein GAN for density reconstruction in dynamic tomography

Object density reconstruction from projections containing scattered radiation and noise is of critical importance in many applications. Existing scatter correction and density reconstruction methods may not provide the high accuracy needed in many applications and can break down in the presence of unmodeled or anomalous scatter and other experimental artifacts. Incorporating machine-learning models could prove beneficial for accurate density reconstruction, particularly in dynamic imaging, where the time evolution of the density fields could be captured by partial differential equations or by learning from hydrodynamics simulations. In this work, we demonstrate the ability of learned deep neural networks to perform artifact removal in noisy density reconstructions, where the noise is imperfectly characterized. Here, we use a Wasserstein generative adversarial network (WGAN), where the generator serves as a denoiser that removes artifacts in densities obtained from traditional reconstruction algorithms. We train the networks from large density time-series datasets, with noise simulated according to parametric random distributions that may mimic noise in experiments. The WGAN is trained with noisy density frames as generator inputs, to match the generator outputs to the distribution of clean densities (time series) from simulations. A supervised loss is also included in the training, which leads to an improved density restoration performance. In addition, we employ physics-based constraints such as mass conservation during the network training and application to further enable highly accurate density reconstructions. Our preliminary numerical results show that the models trained in our frameworks can remove significant portions of unknown noise in density time-series data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crystallographic variant mapping using precession electron diffraction data

In this work, we developed three methods to map crystallographic variants of samples at the nanoscale by analyzing precession electron diffraction data using a high-temperature shape memory alloy and a VO2 thin film on sapphire as the model systems. The three methods are (I) a user-selecting-reference pattern approach, (II) an algorithm-selecting-reference-pattern approach, and (III) a k-means approach. In the first two approaches, Euclidean distance, Cosine, and Structural Similarity (SSIM) algorithms were assessed for the diffraction pattern similarity quantification. We demonstrated that the Euclidean distance and SSIM methods outperform the Cosine algorithm. We further revealed that the random noise in the diffraction data can dramatically affect similarity quantification. Denoising processes could improve the crystallographic mapping quality. With the three methods mentioned above, we were able to map the crystallographic variants in different materials systems, thus enabling fast variant number quantification and clear variant distribution visualization. The advantages and disadvantages of each approach are also discussed. We expect these methods to benefit researchers who work on martensitic materials, in which the variant information is critical to understand their properties and functionalities.

Crystallographic variant mapping↗

Automatic recognition system for document digitization in nuclear power plants

With the increasing number of data-driven models in nuclear applications, large volumes of numerical data are required to accurately model and predict the health status of a plant component. However, many historical operation logs that contain useful information are not fully utilized due to the lack of a systematic approach of digitization. To overcome this issue, this study proposes an automatic pipeline for extracting information from handwritten tabular documents collected from nuclear power plants. In our pipeline, we first denoise scanned documents with morphological operations, and then extract relevant parts from individual pages using both traditional computer vision and neural network methods. Handwriting recognition is applied to obtain text and numbers. As the most challenging step is how to crop only relevant information, the main focus of our paper is to detect tables and cells from scanned handwritten documents. Here we evaluate the efficiency and accuracy of our proposed method on handwritten operational reports obtained from a real-world case study. The results demonstrate the high accuracy and practicality of our proposed method.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DeepMC: a deep learning method for efficient Monte Carlo beamlet dose calculation by predictive denoising in magnetic resonance-guided radiotherapy

Abstract Emerging magnetic resonance (MR) guided radiotherapy affords significantly improved anatomy visualization and, subsequently, more effective personalized treatment. The new therapy paradigm imposes significant demands on radiation dose calculation quality and speed, creating an unmet need for the acceleration of Monte Carlo (MC) dose calculation. Existing deep learning approaches to denoise the final plan MC dose fail to achieve the accuracy and speed requirements of large-scale beamlet dose calculation in the presence of a strong magnetic field for online adaptive radiotherapy planning. Our deep learning dose calculation method, DeepMC, addresses these needs by predicting low-noise dose from extremely noisy (but fast) MC-simulated dose and anatomical inputs, thus enabling significant acceleration. DeepMC simultaneously reduces MC sampling noise and predicts corrupted dose buildup at tissue-air material interfaces resulting from MR-field induced electron return effects. Here we demonstrate our model’s ability to accelerate dose calculation for daily treatment planning by a factor of 38 over traditional low-noise MC simulation with clinically meaningful accuracy in deliverable dose and treatment delivery parameters. As a post-processing approach, DeepMC provides compounded acceleration of large-scale dose calculation when used alongside established MC acceleration techniques in variance reduction and graphics processing unit-based MC simulation.

Engineering↗