Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image charge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Charge-coupled device imaging spectroscopy of Mars. II - Results and implications for Martian ferric mineralogy

Materials similar to nanophase ferric oxides are presently seen to dominate the spectral behavior of the Martian surface in the visible-to-near-IR, in view of imaging spectroscopic observations of Mars. Attention is accordingly given to models for the formation of hematite and other ferric minerals in both current terrestrial environments and in the current and past, possibly wetter Martian climate. It is noted that imaging spectroscopy is an ideal tool for high spatial resolution spacecraft and telescopic studies of the Martian surface.

Bell, James F., III↗

Charge-coupled device imaging spectroscopy of Mars. I - Instrumentation and data reduction/analysis procedures

This paper describes the collection, reduction, and analysis of 0.4-1.0-micron Mars imaging spectroscopy data obtained during the 1988 and 1990 oppositions from Mauna Kea Observatory and provides a general outline for the acquisition and analysis of similar imaging spectroscopy data sets. The U.H. 2.24-m Wide Field Grism CCD Spectrograph was used to collect 13 3D image cubes covering 90 percent of the planet south of 50 deg N in the 0.4-0.8 micron region and covering 55 percent of the planet south of 50 deg N in the 0.5-1.0 micron region. Spectra extracted from these image cubes reveal the detailed character of the Martian near-UV to visible spectrum. Images at red wavelengths reveal the 'classical' albedo markings at 100-500 km spatial resolution while images at blue wavelengths show little surface feature contrast and are dominated by condensate clouds/hazes and polar ice.

Bell, James F., III↗

A Synthesis of Star Calibration Techniques for Ground-Based Narrowband Electron-Multiplying Charge-Coupled Device Imagers Used in Auroral Photometry

A technique is presented for the periodic and systematic calibration of ground-based optical imagers. It is important to have a common system of units (Rayleighs or photon flux) for cross comparison as well as self-comparison over time. With the advancement in technology, the sensitivity of these imagers has improved so that stars can be used for more precise calibration. Background subtraction, flat fielding, star mapping, and other common techniques are combined in deriving a calibration technique appropriate for a variety of ground-based imager installations. Spectral (4278, 5577, and 8446 A ) ground-based imager data with multiple fields of view (19, 47, and 180 deg) are processed and calibrated using the techniques developed. The calibration techniques applied result in intensity measurements in agreement between different imagers using identical spectral filtering, and the intensity at each wavelength observed is within the expected range of auroral measurements. The application of these star calibration techniques, which convert raw imager counts into units of photon flux, makes it possible to do quantitative photometry. The computed photon fluxes, in units of Rayleighs, can be used for the absolute photometry between instruments or as input parameters for auroral electron transport models.

Grubbs, Guy II↗

Altering Interline Transfer In A CCD To Reduce Saturation

In proposed interline-transfer timing scheme for charge-coupled-device (CCD) video imaging array, charges accumulated during some fraction of frame period swept out and dumped to prevent overloading and saturation in intensely illuminated photosites. Excess charges swept out at highest possible rate, while charges used for imaging read out at rate lower but was highest rate that provides complete transfer of charge on array and handled by subsequent signal-processing equipment.

Rentsch, Edward M.↗

Nanometer-Scale Imaging of Inhomogeneous Active Charge Carriers in Arsenic-Doped CdTe Thin Films

We report nanometer-scale imaging of active carrier distribution of As-doped CdTe films by scanning capacitance microscopy (SCM). We developed SCM sample preparation for CdTe by ion-milling followed by thermal processing. The nanometer-resolution carrier delineation for CdTe was validated by imaging on a CdTe cross-section sample made by a molecular beam epitaxy layer stack with As-doping concentrations of 10^15 ~10^18 /cm 3 . We found that the carrier distribution in As-doped films was significantly nonuniform, with inhomogeneity ranging from sub-um to a few um and concentration variation of one order of magnitude (low 10^16 to low 10^17 /cm 3 ). This nonuniformity is distributed randomly, independent of grain structure and grain boundary (GB). We used Kelvin probe force microscopy (KPFM) and cathodoluminescence (CL) to further map the surface potential and radiative illumination on the same area as the SCM image. Higher potential and lower CL intensity were found on GBs but not on SCM contrast, illustrating positive GB charging and GB recombination but not GB-distinguished doping. The overall KPFM potential image is in rough agreement with the SCM carrier distribution, in terms of Fermi-level position relative to the bandgap edge - thus resulting in the band-edge potential fluctuation. Nonuniform carrier concentration, potential fluctuation, and defect recombination can all together cause the Voc deficit of the As-doped CdTe device.

14 SOLAR ENERGY↗

The Ranicon - A resistive anode image converter

A versatile photon and charged particle imaging system is described. The Ranicon employs a microchannel electron multiplier plate to convert each detected event into a charge signal. This charge pulse is proximity-focused onto a large-area resistive anode plate equipped with pickup electrodes on its edges. Each event is located electronically by the ratios of the charges collected at the edges or by the differences of the signals' risetimes. One- or two-dimensional pictures are built up by storing events digitally (e.g., a core memory) or in analog form (e.g., a storage oscilloscope). Compact laboratory models have been constructed and tested. Operating characteristics, applications, limitations, and advantages of the Ranicon are discussed.

Lampton, M.↗

Soft X-ray and XUV imaging with a charge-coupled device /CCD/-based detector

A soft X-ray/XUV imaging camera which uses a thinned, back-illuminated, all-buried channel RCA CCD for radiation sensing has been built and tested. The camera is a slow-scan device which makes possible frame integration if necessary. The detection characteristics of the device have been tested over the 15-1500 eV range. The response was linear with exposure up to 0.2-0.4 erg/sq cm; saturation occurred at greater exposures. Attention is given to attempts to resolve single photons with energies of 1.5 keV.

Loter, N. G.↗

Neutrino event selection in the MicroBooNE liquid argon time projection chamber using Wire-Cell 3D imaging, clustering, and charge-light matching

An accurate and efficient event reconstruction is required to realize the full scientific capability of liquid argon time projection chambers (LArTPCs). The current and future neutrino experiments that rely on massive LArTPCs create a need for new ideas and reconstruction approaches. Wire-Cell, proposed in recent years, is a novel tomographic event reconstruction method for LArTPCs. The Wire-Cell 3D imaging approach capitalizes on charge, sparsity, time, and geometry information to reconstruct a topology-agnostic 3D image of the ionization electrons prior to pattern recognition. A second novel method, the many-to-many charge-light matching, then pairs the TPC charge activity to the detected scintillation light signal, thus enabling a powerful rejection of cosmic-ray muons in the MicroBooNE detector. A robust processing of the scintillation light signal and an appropriate clustering of the reconstructed 3D image are fundamental to this technique. In this paper, we describe the principles and algorithms of these techniques and their successful application in the MicroBooNE experiment. A quantitative evaluation of the performance of these techniques is presented. Using these techniques, a 95% efficient pre-selection of neutrino charged-current events is achieved with a 30-fold reduction of non-beam-coincident cosmic-ray muons, and about 80% of the selected neutrino charged-current events are reconstructed with at least 70% completeness and 80% purity.

3D imaging↗

Surface Charge and Nanoparticle Chromophore Coupling to Achieve Fast Exciton Quenching and Efficient Charge Separation in Photoacoustic Imaging (PAI) and Photothermal therapy (PTT)

Abstract An organic semiconductor nanoparticle (OSN) with surface charge strategy is proposed, which displays excellent photothermal conversion performance. The donor–acceptor hybrid organic semiconductor Y6 is selected as a photothermal chromophore into nanoparticle by self‐assembly, which affords long wavelength absorption, sub‐bandgap emission, and high photon‐to‐thermal conversion. Y6 in OSN adopts closed packing comparing to that in single crystal. The surface charge in OSN causes super‐quenching of the photon excitons, which enhances the nonradiative transition to improve photothermal effect. Lower energy level electronic states are created, which breaks up the bandgap limit and leads to long wavelength emission over 1100 nm. Photothermal therapy and photoacoustic imaging are applied successfully, indicating the success of the new methodology in designing photothermal conversion materials.

Pharmacology & Pharmacy↗

Electronic pictures from charged-coupled devices

Imaging system uses charge-coupled devices (CCD's) to generate TV-like pictures with high resolution, sensitivity, and signal-to-noise ratio. It combines detectors for five spectral bands as well as processing and control circuitry all on single silicon chip.

Mccann, D. H.↗

Preliminary results from a single-photon imaging X-ray charge coupled device /CCD/ camera

A CCD camera is described which has been designed for single-photon X-ray imaging in the 1-10 keV energy range. Preliminary results are presented from the front-side illuminated Fairchild CCD 211, which has been shown to image well at 3 keV. The problem of charge-spreading above 4 keV is discussed by analogy with a similar problem at infrared wavelengths. The total system noise is discussed and compared with values obtained by other CCD users.

Griffiths, R. E.↗

Subtleties in the flat-fielding of charge-coupled device /CCD/ images

Astronomical photometry with CCDs will often involve relatively low signal levels (less than 1000 charge carriers per pixel), at which nonlinear effects sometimes become significant. These effects will probably play a role in the processing of Space Telescope data. The problem apparently arises because signal charges are not read out equally completely from all columns and all pixels. It is shown that, although a first-order correction can be made by subtracting a low-level flat field from all frames before conventional processing, higher accuracy can be achieved by modeling the response with a nonlinear function.

Baum, W. A.↗

Time-resolved site-selective imaging of predissociation and charge transfer dynamics: the CH 3 I B-band

The predissociation dynamics of the 6s (B 2 E) Rydberg state of gas-phase CH 3 I were investigated by time-resolved Coulomb-explosion imaging using extreme ultraviolet (XUV) free-electron laser pulses. Inner-shell ionization at the iodine 4d edge was utilized to provide a site-specific probe of the ensuing dynamics. The combination of a velocity-map imaging (VMI) spectrometer coupled with the pixel imaging mass spectrometry (PImMS) camera permitted three-dimensional ionic fragment momenta to be recorded simultaneously for a wide range of iodine charge states. In accord with previous studies, initial excitation at 201.2 nm results in internal conversion and subsequent dissociation on the lower-lying A-state surface on a picosecond time scale. Examination of the time-dependent yield of low kinetic energy iodine fragments yields mechanistic insights into the predissociation and subsequent charge transfer following multiple ionization of the iodine products. The effect of charge transfer was observed through differing delay-dependencies of the various iodine charge states, from which critical internuclear distances for charge transfer could be inferred and compared to a classical over-the-barrier model. Time-dependent photofragment angular anisotropy parameters were extracted from the central slice of the Newton sphere, without Abel inversion, and highlight the effect of rotation of the parent molecule before dissociation, as observed in previous works. Our results demonstrate the ability to perform three-dimensional ion imaging at high event rates and showcase the potential benefits of this approach, particularly in relation to further time-resolved studies at free-electron laser facilities.

74 ATOMIC AND MOLECULAR PHYSICS↗

Charged Bosons Made of Fermions in Bilayer Structures with Strong Metallic Screening

Two-dimensional monolayer structures of transition metal dichalogenides (TMDs) have been shown to allow many higher-order excitonic bound states, including trions (charged excitons), biexcitons (excitonic molecules), and charged biexcitons. Here, we report here experimental evidence and the theoretical basis for a new bound excitonic complex, consisting of two free carriers bound to an exciton in a bilayer structure. Our experimental measurements on structures made using two different materials show a new spectral line at the predicted energy with two different TMD materials (MoSe 2 and WSe 2 ) with both n- and p-doping, if and only if all the required theoretical conditions for this complex are fulfilled, in particular, only in the presence of a parallel metal layer that significantly screens the repulsive interaction between the like-charge carriers. Because these four-carrier bound states are charged bosons, they could eventually be the basis for a new path to superconductivity without Cooper pairing.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Charge Detector for the Imaging Calorimeter for ACCESS (ICA)

NASA's Advanced Cosmic Ray Experiment for the Space Station (ACCESS) Mission is planned to consist of a transition radiation detector (TRD) and a thin ionization calorimeter. In order to measure the charge of the primary cosmic ray, it is necessary for the calorimeter to have its own charge detector. Silicon detectors are chosen for the charge detector because of their excellent resolution, small size and nearly square shape. Monte Carlo simulations are performed to find the probability of misidentifying protons as alpha particles due to backscattered radiation from the calorimeter. Simulations were also used to investigate identifying primary cosmic rays that fragmented in the TRD before reaching the calorimeter. For this study algorithms have been developed for determining a direction of the core shower in the calorimeter. These algorithms are used to find the approximate location of the primary particle in the silicon detectors. Results show the probability to misidentify the charge depends upon the energy and direction of the primary particles.

Lee, Jeongin↗

Texas Instruments /TI/ 800 x 800 charge-coupled device /CCD/ image sensor

Very-large area high-performance CCD image sensors with 800 x 800 pixel format have been successfully fabricated and operated on the basis of a three-level polysilicon gate technology. They are thinned to 8 microns over the entire 12.2 x 12.2 mm active area, and are used in the rear illumination mode. The light transfer characteristic has a gamma value of 1.000 + or - 0.002 over most of the dynamic range. Analysis of the noise behavior shows that the device SNR is shot-noise-limited over most of the dynamic range. Simple on-chip signal processing can be performed using an integration well to noiselessly collect signal charge from multiple pixels prior to reading out the charge. A UV-sensitive phosphor has been applied to the chip, yielding a device capable of imaging at wavelengths from the vacuum UV to the near IR.

Blouke, M. M.↗

Solid state television camera

The design, fabrication, and tests of a solid state television camera using a new charge-coupled imaging device are reported. An RCA charge-coupled device arranged in a 512 by 320 format and directly compatible with EIA format standards was the sensor selected. This is a three-phase, sealed surface-channel array that has 163,840 sensor elements, which employs a vertical frame transfer system for image readout. Included are test results of the complete camera system, circuit description and changes to such circuits as a result of integration and test, maintenance and operation section, recommendations to improve the camera system, and a complete set of electrical and mechanical drawing sketches.

Source record↗