Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “hydro electric power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

New Tool Evaluates the Financial Viability of Pumped Storage Hydropower

The rapidly evolving electricity system with increasing variable renewable energy (VRE) resources provides both opportunities and challenges for the power sector. With the significant ramps and intermittency associated with VRE resources, the requirements and need for additional flexible resources increase. Pumped storage hydropower (PSH) provides flexibility to the electricity grid to replace fossil fuel plants, which are responsible for 25% of U.S. emissions. PSH projects support various aspects of power system operations, including flexibility, ramping capability, energy, ancillary service, black start, and others. The significant potential of hydropower requires understanding the different value drivers to the electricity system specific to the location of a project and then optimizing the plant for the different system values. Thus, determining the value of PSH projects and their many services and contributions to the electricity system can be a challenge for potential developers, system owners, regulators, policy makers, and consultants.

13 HYDRO ENERGY↗

Quantifying Risk in an Uncertain Future: The Evolution of Resource Adequacy

As our power grids transition toward a decarbonized energy mix, ensuring reliability and provision of grid services remains paramount. The power system has always been heavily influenced by the weather - extreme temperatures determine the timing of peak demand, winter cold snaps can limit natural gas supply, gas turbine reliability and output are affected by ambient conditions, and hydro output varies seasonally and annually. However, as the grid increasingly relies on variable renewable energy (VRE), like wind and solar, the attention to reliability and weather conditions is increasingly important. The implications of changing reliability are large. The Electric Reliability Council of Texas (ERCOT) rolling blackouts from earlier this year impacted millions of people across the state and could be seen from space (Figure 1).

hydraulic turbines↗

How Fisheries Biologists Can Facilitate the Clean Energy Transition

Abstract Fisheries and aquatic biologists play a critical role in creating environmentally protective hydropower flow requirements that govern flow timing, frequency, magnitude, and rate of change. Hydropower's role in the U.S. electrical grid is expected to evolve in response to increased wind and solar generation as hydropower will be called upon to quickly ramp up and down in response to changes in wind and solar generation. For this reason, hydropower is expected to have increased value as fossil generation is phased out, even as rapid flow fluctuations linked with hydropower flexibility may strand fish, alter habitat, and create unsafe recreational conditions. We face a new challenge in facilitating the renewable energy transition—designing environmental flow requirements that protect against the impacts of flow fluctuations while allowing adequate hydropower flexibility to support a stable grid. In this paper, we discuss hydropower environmental flow requirements, operational flexibility, and electrical grid stability, their potential interactions, and opportunities to align environmental and power system needs to support healthy ecosystems, multiple water uses, and decarbonization of the electric grid.

13 HYDRO ENERGY↗

Life Cycle Emissions Factors for Electricity Generation Technologies

This dataset consists of a table containing the distribution of literature estimates of greenhouse gas emissions for the following electricity generation and storage technologies: biopower, coal, concentrating solar power, geothermal, hydrogen storage, hydropower, lithium-ion battery storage, natural gas, nuclear, ocean, oil, photovoltaic, pumped-storage hydropower, and wind. Quartile estimates of life cycle emissions factors in units of grams of carbon dioxide equivalent per kilowatt hour of generation (g CO2e/kWh) are provided for the following life cycle stages: one-time upstream, ongoing combustion, ongoing non-combustion, one-time downstream, and total. Literature estimates were compiled by the LCA Harmonization study and subsequent updates, as detailed in the factsheet which accompanies this dataset, https://www.nlr.gov/docs/fy21osti/80580.pdf .

01 COAL, LIGNITE, AND PEAT↗

Modeling the impact of extreme summer drought on conventional and renewable generation capacity: Methods and a case study on the Eastern U.S. power system

Across recent years, there has been a growing prevalence of extreme weather events throughout the United States, posing significant challenges to the reliable and resilient operation of power systems. Specifically, summer droughts threaten to severely reduce available generation capacity to meet regional electricity demand, potentially leading to power outages. This underscores the importance of accurate resource adequacy (RA) assessment to ensure the reliable operation of the nation’s energy infrastructure. Accurately evaluating the usable capacity of regional generation fleets is a challenging undertaking due to the intricate interactions between power systems and hydro-climatic systems. Here, this paper proposes a systematic and analytical framework to evaluate the impacts of extreme summer drought events on the available capacity of various generating technologies, incorporating both meteorological and hydrologic factors. The framework provides detailed plant-level capacity derating models for hydroelectric, thermoelectric, and renewable power plants, facilitating evaluations with high temporal and spatial resolution. The application of the proposed impact assessment framework to the 2025 generation fleet of the real-world power system within the PJM and SERC regions of the United States yields insightful results. By analyzing the daily usable capacity of 6,055 at-risk generators across the study region, it shows that the summer capacity deration is most significant for hydroelectric and once-through thermal power plants, followed by recirculating thermal power plants and combustion turbines. In the event of the recurrence of the 2007 southeastern summer drought event in the near future, the generation fleet could experience a substantial reduction in available capacity, estimated at approximately 8.5 GW, compared to typical summer conditions. The sensitivity analysis reveals that the usable capacity of the generation fleet would suffer an even more significant decrease under conditions of increasingly severe summer droughts. The proposed approach and the findings of this study provide valuable methodologies and insights, empowering stakeholders to bolster the resilience of power systems against the potentially devastating effects of future extreme drought events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Preparing the Power Sector to Navigate Climate and Water Risks

As the climate changes, so will water availability and other ambient conditions, threatening the reliability of today's power system and tomorrow's clean energy grid. That's why researchers at the National Renewable Energy Laboratory (NREL) - along with those at Sandia National Laboratories, Oak Ridge National Laboratory, the City University of New York, the Electric Power Research Institute, and the National Energy Technology Laboratory - are studying both regional and national climate and hydrologic changes to provide a comprehensive assessment of climate and water impacts and risks to the U.S. power grid.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

Impact of Quaternary Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Impact of Quaternary-Pumped Storage Hydropower on Frequency Response of U.S. Western Interconnection with High Renewable Penetrations: Preprint

As renewable penetration increases in the United States, maintaining stability and reliability of low-inertia power grid by providing sufficient frequency control capability becomes a challenge. Advanced pumped storage hydro technologies (APSH) will be expected to play an important role for future grid as not only an energy supplier, but also as an ancillary services provider. This paper studies the impact of using quaternary pumped storage hydropower (Q-PSH), as one of the newly proposed APSH technology, to provide primary frequency response. To quantify the impact of Q-PSH on frequency response of the U.S. Western Interconnection, a user-defined dynamic model of Q-PSH is developed on the GE Positive Sequence Load Flow (PSLF) platform and is implemented in a set of detailed U.S. Western Electricity Coordination Council (WECC) planning cases in which renewable penetration levels are 20%, 40%, 60% and 80%. Simulation results show that Q-PSH can help improve frequency nadir and settling frequency comparing to the conventional PSH.

frequency response↗

Economic dispatch for electricity merchant with energy storage and wind plant: State of charge based decision making considering market impact and uncertainties

Here this paper investigates how the market impact of electricity merchants and uncertainty of wind generation affect their co-optimized scheduling policy, specifically for merchants who have both energy storage and wind plants. In the existing literature, merchants' trading actions are usually assumed not to affect market prices; however, a large-scale energy storage merchant's actions can affect market prices. To this end, we approximate the electricity price by a linear function of the quantity of power traded by the merchant in the reward function to achieve decision-making incorporating the market impact. This paper utilizes the dynamic programming approach to analyze merchants' optimal multi-period decision-making incorporating market impact, uncertain wind generation, and energy storage constraints. First, our results demonstrate that for a merchant with co-located energy storage facilities and wind power plants, the energy storage's feasible state of charge (SOC) range can be segmented into four possible sub-ranges by three analytically developed SOC reference points. The unique optimal trading decision can be achieved by comparing the current energy inventory and the SOC references of the next period. Second, our results show that market impact and uncertainties substantially change the optimal storage scheduling policy by impacting the values of the reference points. To mitigate the negative effect of the merchant's market impact on buying and selling actions, the merchant may reduce the amount of generating or pumping electricity each period to maximize profit. Moreover, we identify and investigate the trade-off between market price and transaction quantity. Our findings provide co-optimized scheduling guidance for electricity merchants with co-located energy storage and renewable power plants systems.

17 WIND ENERGY↗

Comparison of Energy Storage and Arbitrage Options for Nuclear Power

Nuclear power is the most reliable source of clean energy and plays a crucial role in decarbonization efforts and national energy security. Achievement of Net-Zero targets depends on the deployment of new Nuclear Power Plants (NPPs) – both advanced reactors and large-scale Light-Water Reactors (LWRs) – as well as continuing operations at existing LWR plants. The Light-Water Reactor Sustainability (LWRS) program seeks to extend the lifetime of existing NPPs and improve their economic performance through research into plant modernization, Flexible Plant Operation and Generation (FPOG), risk-informed systems analysis, materials research, and physical security. The FPOG pathway investigates alternative revenue streams for LWRs. When electricity prices are driven low by an oversupply of renewable energy, steam and electricity from an NPP can be used to make value-added products while taking advantage of the low energy price; alternatively, this cheap energy can be stored chemically, electrically, or thermally, and used to regenerate-generate electricity at a later time when energy demand, and therefore the wholesale price of electricity, is higher in an economic concept called arbitrage. The purpose of this report is to investigate energy storage technologies that can store 500 MW of electricity from an LWR for a wide spectrum of durations.

13 HYDRO ENERGY↗

Energy Storage Technologies and U.S. Department of War Requirements

This report offers an overarching primer the energy storage market and assessment of each technology’s suitability for U.S. Department of War applications. We find that battery energy storage is the most promising technology for energy storage applications in terms of energy density and cost. While commercial and advanced Li-ion can satisfy certain electric mobility (e.g., cars, midsized vehicles) and electric flight application (e.g. drones) needs of DoW, next generation technologies like Li metal solid-state batteries, and conversion chemistries (Li-air, Li-CFx) are needed for heavy duty applications like armored vehicles, tanks, airplanes, jets. Batteries should also be supplemented with technologies such as supercapacitors and next-generation flywheels to provide short bursts of high energy for high power needs. Thermal energy storage solutions (sensible and latent heat) and fuel cells (PEMFC and SOFC) are good alternatives for supporting energy storage applications in terms of energy density and cost. Gravity-based energy storage promises the least energy density with high cost and should only be used for niche DoW applications. Of the different gravity energy storage technologies reviewed, pumped-hydro, flywheel, and compressed air energy storage are promising, while solid gravity energy storage appears the least attractive. Military facilities requiring 14 days of energy storage can benefit from flow batteries, especially commercial VFRBs and next generation iron-air systems. While VFRBs are expensive, iron-air batteries have the coupled benefits of low cost and good energy density promising 100+ hours of storage.

25 ENERGY STORAGE↗

Nine Canyon Long-Duration Energy Storage: A Feasibility Study

The Nine Canyon Long Duration Energy Storage (LDES) Feasibility Study explores the technical and economic viability of deploying advanced energy storage technologies at Energy Northwest's (EN) Nine Canyon (9C) Wind Project site in Benton County, Washington. Supported by the Washington State Department of Commerce and the U.S. Department of Energy’s Office of Electricity under its LDES Voucher Program, the study represents a collaborative effort between EN, Pacific Northwest National Laboratory (PNNL), and ARES North America. At the core of this effort is the development of a generalized techno-economic modeling framework and evaluation tool designed to assess the value proposition of LDES projects across a variety of contexts. The modeling tool is technology-agnostic and accommodates user-defined parameters such as rated power, energy duration, round-trip efficiency, capital and operational costs, and dispatch constraints. It also integrates economic inputs, including market prices, energy revenue structures, and financing parameters to evaluate performance through key metrics. The tool provides utilities with a transparent, adaptable platform to support decision-making, investment prioritization, and portfolio planning for various storage technologies. To guide scenario design and interpretation, the study first surveyed the LDES technology landscape, including lithium-ion batteries, flow batteries, non-hydro gravity storage, and thermo-mechanical systems, comparing cost trajectories, technical performance, safety and hazards, materials sourcing and recyclability, and spatial/siting considerations. This literature-grounded review highlights technology trade-offs and reinforces the need to align technology choice with site characteristics, use cases, and project objectives. A companion chapter examines ownership structures (EN ownership, third-party ownership, shared models) and offtake options (energy marketing, capacity/energy PPAs, time-of-use PPAs, block-delivery PPAs, and tolling), where PPAs (power purchase agreements) represent contractual arrangements for buying and selling electricity. The chapter also highlights implications for risk allocation, capital access, operational control, and revenue certainty. The study also evaluates supervisory control and data acquisition (SCADA) and transmission interconnection pathways, options include upgrading the existing SCADA or deploying a dedicated LDES controller, with attention to protection schemes, data telemetry, cybersecurity, and regulatory coordination with BPA. In addition, an ARES-specific geotechnical and hydrology assessment presented in the appendix screens multiple corridors for slope stability, bearing capacity, cut-and-fill magnitude, and stormwater behavior.

25 ENERGY STORAGE↗

Black start demonstrations of small hydropower plants with energy storage

The U.S. has at least 500 municipal, electric co-operative, and publicly owned utilities with hydropower plants. These are mostly grid-connected to support the national grid. However, due to small size (at most 10 MW) and low ramping capacity, many of these hydropower plants lack the capability to form local grids to provide backup power to critical loads (during grid outage) and rural areas. Energy storage, such as Li-Ion batteries or ultracapacitors, can be used to enable these capabilities. Because this technology is relatively new, proof-of-concept demonstrations are needed to de-risk the approach before it can be deployed at scale. Two field demonstrations have been performed to validate this approach, namely, a 375 kVA / 1.24 kWh ultracapacitor with Idaho Falls Power’s 3.6 MW Old Lower (OL), 8.9 MW Lower Bulb (LB), and 8.9 MW City Bulb (CB) hydropower plants; and a 250 kVA / 320 kWh Li-Ion battery with Fall River Electric Cooperative’s 5.5 MW Felt hydropower plant. The Idaho Falls Power demonstration showed the resilience benefits of hybridization, and the Fall River Electric demonstration showed what the minimal requirements are to retrofit a hydropower plant for black start. These demonstrations are funded by the U.S. Department of Energy Water Power Technologies Office HydroWIRES Initiative.

13 HYDRO ENERGY↗

Global Perspective of Energy Storage (2019 Annual Peer Review Report)

This report provides information about the DOE Office of Electricity Energy Storage Peer Review held in 2019 and includes posters reviewed in these categories: postdoctoral, validated reliability and safety performance, equitable regulatory environment and analytics, applied materials (Materials I), power electronics, industry acceptance, partnerships, and Materials I.

13 HYDRO ENERGY↗

An assessment of existing barriers to market adoption of thermal energy storage in buildings based on interviews with stakeholders

The United States administration recently established a goal of reducing greenhouse gas emissions by half below 2005 levels by 2030 and becoming a carbon-neutral economy by 2050. The transition to renewable energy sources may be significantly aided by energy storage. Energy storage could smooth the delivery of variable or intermittent renewable energy sources such as wind, hydro, and sun by storing excess renewable energy when it’s available and delivering it back when renewable energy production is low. Thermal energy storage (TES) is a way that stores thermal energy by heating or cooling a storage medium, which is then used for space heating and cooling, industrial processes, or power generation purposes later. This TES operation could lessen the demand for electricity in both the winter's and the summer's peak hours of electricity. While there are various studies that focus on the advancements and successes of TES technology, less attention is placed on its market adoption. Therefore, the current study undertakes survey-based interview research to understand the existing market barriers hindering TES application in buildings. A series of interviews were performed in this study with individuals from various backgrounds, ranging from homeowners to market specialists who work for TES manufacturers and utility companies. According to the responses obtained during the interviews, they strongly believe that TES has a high potential to contribute to the nation's grid stability and decarbonization goals, however, there are several barriers that prevent homeowners and heat pump manufacturers from investing in TES applications. The current study divided the responses from various background groups into categories to better understand the current challenges for TES applications in buildings. These responses range from payback concerns from homeowners to the need to develop a new metric to represent the benefits of TES from the heat pump and TES manufacturers. The findings from this study can be used by policymakers, utility companies, and manufacturers to better understand present obstacles and develop strategies to overcome them.

Prem Anand Jayaprabha, Jyothis Anand↗

Large Power Transformer Supply Chain Gap Analysis and Domestic Content Strategies for Hydropower Rehabilitation: Supplemental Report

Large Power Transformers (LPTs) are indispensable to U.S. hydropower operations, serving as generator step-up (GSU) units that interconnect hydro facilities to the transmission grid. Yet the LPT supply chain faces mounting stress from aging infrastructure, limited domestic production, and long lead times. Currently, more than 80% of LPT demand is met through imports, with primary suppliers including Mexico, South Korea, Brazil, Austria, and Canada. Domestic manufacturers supply only about 20% of units, constrained by bottlenecks in high-grade Grain-Oriented Electrical Steel (GOES), copper conductors, bushings, and on-load tap changers (OLTCs). Hydropower rehabilitation projects in particular face additional challenges due to custom design requirements, remote siting, and regulatory needs around domestic content. Regional cost disparities, driven by transportation logistics, labor markets, and import price volatility, further exacerbate project risks. To address these vulnerabilities, coordinated action is required: strengthening domestic capacity for GOES and secondary components, developing near-site assembly hubs, and leveraging IRS domestic content safe harbors to incentivize U.S. manufacturing. This addendum refines the 2024 NREL Hydropower Supply Chain Gap Analysis by focusing specifically on critical issues related to LPT domestic manufacturing capacity and key considerations for hydropower developers and asset owners.

13 HYDRO ENERGY↗

Integrated Carbon Capture and Storage in Hydrogen Production: A Combined Techno-Economic and Life Cycle Assessment

This paper presents a coupled techno-economic and life cycle assessment of “blue” hydrogen to be produced at a hydrogen facility through steam methane reforming (SMR) equipped with carbon capture and storage (CCS). Blue hydrogen was modeled in ChemCAD, while an integrated asset model represented the carbon capture and storage chain. An unabated carbon dioxide (CO 2 ) configuration release 11.99 kgCO 2 -eq/ kgH 2 . Capturing ≥95% of the CO 2 stream lowers the carbon footprint to 6.59 kgCO 2 -eq/kgH2 but raises the levelized cost of hydrogen (LCOH) from $\$$1.82/kgH 2 (no CO 2 capture) to $\$$3.22/kgH 2 ; the U.S. 45Q tax credit reduces it to $\$$2.59/kgH 2 . Incorporating CCS reduces the levelized net present value from $\$$0.87/kgH 2 to $\$$0.74/kgH 2 , owing to additional capture, transport, and storage costs. Supplying SMR with low-carbon electricity, especially nuclear, wind, or hydro, delivers the lowest carbon footprint relative to geothermal or grid mixes. Sensitivity analysis identifies that hydrogen sales price, internal rate of return, and CCS cost as the strongest economic levers, while electricity demand dominates residual lifecycle emissions. The results underscore a clear trade-off; substantial CO 2 reductions are achievable, but only with higher production costs, making supportive policy instruments, access to clean power, and robust hydrogen markets essential for large-scale deployment of blue hydrogen.

carbon capture↗

Options for Resilient and Flexible Power Systems in Select South American Economies

This presentation provides highlights from the published report TP-6A50-75431, which summarizes opportunities for Argentina, Brazil, Chile and Colombia to adapt to the new forces buffeting electricity sectors around the globe to ensure reliable, affordable, sustainable and resilient power systems. Special attention is placed on the potential role for natural gas to help ensure flexible and resilient power systems in those countries.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY,↗