Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “human systems performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Full-wave and half-wave rectification in second-order motion perception

Microbalanced stimuli are dynamic displays which do not stimulate motion mechanisms that apply standard (Fourier-energy or autocorrelational) motion analysis directly to the visual signal. In order to extract motion information from microbalanced stimuli, Chubb and Sperling [(1988) Journal of the Optical Society of America, 5, 1986-2006] proposed that the human visual system performs a rectifying transformation on the visual signal prior to standard motion analysis. The current research employs two novel types of microbalanced stimuli: half-wave stimuli preserve motion information following half-wave rectification (with a threshold) but lose motion information following full-wave rectification; full-wave stimuli preserve motion information following full-wave rectification but lose motion information following half-wave rectification. Additionally, Fourier stimuli, ordinary square-wave gratings, were used to stimulate standard motion mechanisms. Psychometric functions (direction discrimination vs stimulus contrast) were obtained for each type of stimulus when presented alone, and when masked by each of the other stimuli (presented as moving masks and also as nonmoving, counterphase-flickering masks). RESULTS: given sufficient contrast, all three types of stimulus convey motion. However, only one-third of the population can perceive the motion of the half-wave stimulus. Observers are able to process the motion information contained in the Fourier stimulus slightly more efficiently than the information in the full-wave stimulus but are much less efficient in processing half-wave motion information. Moving masks are more effective than counterphase masks at hampering direction discrimination, indicating that some of the masking effect is interference between motion mechanisms, and some occurs at earlier stages. When either full-wave and Fourier or half-wave and Fourier gratings are presented simultaneously, there is a wide range of relative contrasts within which the motion directions of both gratings are easily determinable. Conversely, when half-wave and full-wave gratings are combined, the direction of only one of these gratings can be determined with high accuracy. CONCLUSIONS: the results indicate that three motion computations are carried out, any two in parallel: one standard ("first order") and two non-Fourier ("second-order") computations that employ full-wave and half-wave rectification.

Motion Perception/physiology↗

Human Readiness Levels Explained

The Human Readiness Level scale complements and supplements the existing technology readiness level scale to support comprehensive and systematic evaluation of human system aspects throughout a system’s life cycle. The objective is to ensure humans can use a fielded technology or system as intended to support mission operations safely and effectively. This article defines the nine human readiness levels in the scale, explains their meaning, and illustrates their application using a helmet-mounted display example.

60 APPLIED LIFE SCIENCES↗

Dynamic Instructions for Nuclear Power Plant Field Workers

Most tasks conducted at a nuclear power plant are guided by a procedure in one way or another. Some tasks must be conducted by strictly adhering to the prescribed steps, while other tasks use the procedures as a reference guide. Traditionally, the procedure process in the nuclear industry has been paper heavy. In recent years however, the nuclear industry has considered adopting more dynamic solutions to improve the efficiency of their work management process, advance human and system performance, as well as reduce the cost of handling paper copies of documentation. As a first step, many nuclear utilities in the U.S. deployed solutions that electronically route the documents through the review and approval processes and where the worker in the field uses an electronic copy of the instruction or procedure on a handheld device. These electronic copies are very similar to the format of the paper instruction but do have some additional capabilities to capture recorded input and notes.

47 OTHER INSTRUMENTATION↗

Characterization of Peripheral Neurophotonic Systems for High-Performance Human-Computer Interfaces (CRADA Final Report)

As part of the Cyclotron Road program, Morphosis Inc. sought to investigate a non-invasive neuromuscular sensing approach for use as an intuitive and secure human–computer interface. These highly miniaturized, wearable neural interfaces were completely non-invasive and maintained stable, high-bandwidth, long-term access to a user’s actions, intent, and identity, while offering an exceptionally high signal-to-noise ratio compared to contemporary neural recording technologies. The widespread adoption of neural interfaces had the potential to reshape how people interact with technology, with profound societal impacts. Millions worldwide suffered from movement and/or speech disabilities, and these tools had the potential to democratize access to technology to enhance autonomy and quality of life. More broadly, interfaces capable of accurately conveying intentions and safeguarding identities could serve as a cornerstone for privacy, trust, and personal authenticity in digital environments. The use of thought-driven control of digitally enabled devices and governance of digital identities had the potential to revolutionize relationships with technology, transforming how people learn, communicate, and interact with the world.

42 ENGINEERING↗

Aerospace Medicine and Biology: A continuing bibliography with indexes (supplement 259)

A bibliography containing 476 documents introduced into the NASA scientific and technical information system in May 1984 is presented. The primary subject categories included are: life sciences, aerospace medicine, behavioral sciences, man/system technology, life support, and planetary biology. Topics extensively represented were space flight stress, man machine systems, weightlessness, human performance, mental performance, and spacecraft environments. Abstracts for each citation are given.

Source record↗

CO2-O2 interactions in extension of tolerance to acute hypoxia

Objectives and results of experimental projects a re summarized. The scope of information desired included (1) physiological and performance consequences of exposures to simulated microgravity, in rest and graded physical activity, (2) separate influences of graded degrees of atmospheric hypercapnia and hypoxia, and (3) composite effects of hypoxia and hypercapnia. The research objectives were selected for close relevance to existing quantitative information concerning interactions of hypercapnia and hypoxia on respiratory and brain circulatory control. They include: (1) to determine influences of normoxic immersion on interrelations of pulmonary ventilation, arterial PCO2 and PO2, and brain blood flow, in rest and physical work; (2) to determine influence of normoxic immersion on respiratory reactivity to atmospheric hypercapnia at rest; (3) to determine influence of atmospheric hypoxia on respiratory reactivity to hypercapnia at rest and in work; and (4) to provide physiological baselines of data concerning adaptations in acute exposures to aid in investigation of rates of adaptation or deteriorations in physiological or performance capability during subsequent multi-day exposures. A list of publications related to the present grant period is included along with an appendix describing the Performance Measurement System (human perceptual, cognitive and psychomotor functions).

Lambertsen, C. J.↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S. Faragalla↗

Kinematic Sensors Evaluation for Spaceflight Exercise Data Collections

INTRODUCTION: On the International Space Station (ISS), exercise feedback from astronauts is very important to diagnose and mitigate any form-related injuries and ensure efficacious exercise prescriptions and systems. Going forward, exploration exercise efforts seek to gain further quantitative data of human and system performance. Currently, methods of collecting in-flight exercise data on the ISS are limited to marker-based motion capture (MoCap) where astronauts must wear reflective markers over their clothes and specialized cameras are used. The main objective of this work was to investigate the following alternative tracking options: markerless video-based MoCap and inertial measurement units (IMUs). These were compared against traditional marker-based MoCap to evaluate kinematic accuracy and inform feasible methods for future exercise data collections on the ISS, especially in support of future Vibration Isolation and Stabilization (VIS) system development. METHODS: Three test subjects performed a variety of flight-like resistance and aerobic exercises using the Miniature Exercise Device (MED-2), Concept-2 rowing ergometer, barbell mockup, bench (e.g., for bench press, hip thruster, and cycling), and a custom structure for dips. These were intended also to represent exercises which could be performed on the multi-modality European Enhanced Exploration Exercise Device (E4D) [1]. The marker-based MoCap data, collected through a 16-camera OptiTrack MoCap system, was regarded as the gold standard to compare the data against. Passive markers were affixed to each subject according to a modified full body Plug-in Gait marker set [2] with 46 total markers. The markerless MoCap data was collected using two GoPro Hero7 cameras and one GoPro Hero11 camera. For the IMU data, a full body set of 17 Xsens DOTs were placed on the subject: 10 upper body and 7 lower body IMUs. Biomechanical modeling and evaluation was conducted through OpenSim [3] (MoCap), OpenSense [4] (IMU), OpenCap [5] (markerless), ENABLE [6] (markerless), and other modeling software. Secondary objectives included comparing the volume of equipment, reducing mass and crew set-up time. RESULTS AND DISCUSSION: While there were issues with initial processing for the IMUs and markerless MoCap, the results aided in the understanding of each sensor, developing end-to-end processes, and identifying future needs. Some observed concerns with the markerless MoCap approaches included being cognizant of a cluttered background, number of people in field of view, camera number and placement. Some challenges with the IMUs included possible sliding, early deactivation possibly due to exercise pose, and large quantity sensor synchronization. Overall, the markerless MoCap option may be the preferred method of data collection and processing as it provides a solution for certain IMU shortcomings and may be least in equipment volume, upmass, and crew setup time. CONCLUSIONS: While this work was mainly focused on ISS data collection, these sensor data along with continued evaluation and development efforts will help to establish best methods for exercise data collection on Gateway, for other Artemis missions, and beyond. Details on the latest end-to-end processing of the data and results will be presented, along with lessons learned and recommended sensor selection and methods.

S Faragalla↗

Spaceflight Human System Standards

NASA created a new approach for human system integration and human performance standards. NASA created two documents a standard and a reference handbook. The standard is titled NASA Space Flight Human-System Standard (SFHSS) and consists of two-volumes: Volume 1- Crew Health This volume covers standards needed to support astronaut health (medical care, nutrition, sleep, exercise, etc.) Volume 2 Human Factors, Habitability and Environmental Health This volume covers the standards for system design that will maintain astronaut performance (ie., environmental factors, design of facilities, layout of workstations, and lighting requirements). It includes classic human factors requirements. The new standards document is written in terms so that it is applicable to a broad range of present and future NASA systems. The document states that all new programs prepare system-specific requirements that will meet the general standards. For example, the new standard does not specify a design should accommodate specific percentiles of a defined population. Rather, NASA-STD-3001, Volume 2 states that all programs shall prepare program-specific requirements that define the user population and their size ranges. The design shall then accommodate the full size range of those users. The companion reference handbook, Human Integration Design Handbook (HIDH), was developed to capture the design consideration information from NASA-STD-3000, and adds spaceflight lessons learned, gaps in knowledge, example solutions, and suggests research to further mature specific disciplines. The HIDH serves two major purposes: HIDH is the reference document for writing human factors requirements for specific systems. HIDH contains design guidance information that helps insure that designers create systems which safely and effectively accommodate the capabilities and limitations of space flight crews.

Holubec, Keith↗

Predicting Cognitive States Using Machine Learning Fusion Paradigms to Reduce Model Uncertainty

The development of a synergetic system between humans and technology is a challenge that the scientific community has been facing for many years. Our aeronautic research aims to enhance this synergy between humans and machines through predictive human performance modeling for systems to mitigate high-risk situations. By being able to predict and anticipate human states, the crew monitoring system should be able to adjust and support the pilot for aviation safety. Our work focusing on attention-related human performance-limiting states (AHPLS) that impact a pilot’s performance and introduce high-risk catastrophic situations [1]. For example, AHPLS has been cited as a causal factor in more than 50% of all loss control in flight and thus contributes significantly toward commercial aviation fatalities [1, 2]. Cognitive state and its physiological fingerprint can be valuable information for this detecting AHPLS, but human cognitive state detection is still a major limitation for these crew monitoring systems.

machine learning↗

Performance Risk Model (PRisM) Proof-of-Concept: An Operational Decision Support Tool to Predict Crew Performance in Space from Available Performance Tests

The Crew Health and Performance-Probabilistic Risk Assessment (CHP-PRA) team at NASA Glenn Research Center has developed a range of tools to evaluate astronaut health during spaceflight and to optimize the medical set required for missions. Among these, the Performance Risk Model (PRisM) represents a novel advancement, extending CHP-PRA’s focus beyond medical systems into the domain of human performance. Such tool could be pivotal in optimizing astronaut capabilities during space travel, thereby enhancing overall mission success. PRisM leverages data from well-established performance assessments conducted during previous crewed space missions and Earth analogs to strategically predict outcomes for planned tasks, even when direct performance testing has not been conducted for those specific tasks. To evaluate performance, PRisM references the various metrics outlined in NASA-STD-3001 and employs a methodology to integrate different performance scales. This framework analyzes the contribution of various human system task categories (HSTCs) to task execution and compares these contributions to the HSTCs’ involvement in other known tests. The model further employs a Monte Carlo simulation to sample performance scores from their distribution in operationally relevant tests such as those in Mulavara et al. (2018) and, by leveraging similarities in HSTC involvement, transfers this knowledge to actual mission tasks, such as those outlined in the "Human Exploration of Mars: Preliminary List of Crew Tasks”. The current PRisM proof-of-concept includes analyses of the impact of exercise and specific medications on astronauts’ performance, with provisions to incorporate additional countermeasures as data becomes available. Furthermore, the tool is customizable to include any system necessary to fully encompass the domain of human systems and can be adapted to evaluate performance for any spaceflight activities as requested by operational stakeholders. PRisM has the potential to assist the Human Research Program in exploring the capabilities trade space for optimized crew performance.

performance modeling↗

Integrating Human System Information with the Systems Platform for Aggregating and Relating Capabilities (SPARC)

Within Human Health and Performance, there exists a wealth of human system information that’s used a regular basis in support of NASA human exploration objectives, but the challenge is that all of this information was stored in multiple different locations and organized for specific uses, limiting its effectiveness and straining communication across multiple groups. To address this challenge, our project, the Systems Platform for Aggregating and Relating Capabilities (SPARC) was tasked with developing a new NASA internal web application that aggregates and relates multiple programs’ human system products, such as technical standards, program requirements and verifications, human system risks, research and evidence, and exploration capabilities, into one centralized platform that addresses the needs of human health and performance from multiple different perspectives. Using agile development methodologies, user-experience (UX) driven design principles, data visualization, and a strong emphasis on continuous improvement though consistent stakeholder engagement, the SPARC project released a beta version in less than 4 months, broadly launched version 1.0.0 Agency-wide three months after the beta, and has over 180 users in the first year of development. Our second year of development will see us moving from our initial capabilities to increasingly robust and complex integrations and visualizations, including Directed Acyclical Graphs (DAGs), natural language processing (NLP) for dynamic generation of relationships between the sources of truth, and an expansion into hierarchical levels of system design in support of the human exploration programs.

Data science↗

Resilience Engineering's Potential for Advanced Air Mobility (AAM)

The national airspace (NAS) will rapidly evolve in the next ten to twenty years. Plans for Advanced Air Mobility (AAM) during that period envision highly automated airspace management systems and electrically powered vehicles. AAM concepts also anticipate limited human roles. The goal of limiting the human role is to minimize the potential for misadventures, yet how the human role is limited needs to be carefully considered in order to also preserve the potential for human successes. The field of resilience engineering (RE) focuses on how systems can change in order to seize an opportunity or withstand an unforeseen challenge. RE methods rely on the use of empirical data to optimize the ability of any system to adapt. RE studies have shown how individual and team initiatives ensure resilient system performance by creating safety through flexibility. Benefits of the RE approach include improved awareness of operational circumstances and how system elements depend on each other, and the ability to allocate limited resources and prepare for surprise. RE offers the ability to account for and incorporate the human role as an essential element in order to ensure NAS systems’ resilient performance. Data on the human contribution to safe and resilient system performance, which is termed “work as done,” are available but are not being considered as the NAS evolves. We present an approach that describes how use of RE can enable the evolving NAS to adapt, and perform, in a resilient manner.

Aviation Safety↗

Human-Robot Interaction in High Vulnerability Domains

Future NASA missions will require successful integration of the human with highly complex systems. Highly complex systems are likely to involve humans, automation, and some level of robotic assistance. The complex environments will require successful integration of the human with automation, with robots, and with human-automation-robot teams to accomplish mission critical goals. Many challenges exist for the human performing in these types of operational environments with these kinds of systems. Systems must be designed to optimally integrate various levels of inputs and outputs based on the roles and responsibilities of the human, the automation, and the robots; from direct manual control, shared human-robotic control, or no active human control (i.e. human supervisory control). It is assumed that the human will remain involved at some level. Technologies that vary based on contextual demands and on operator characteristics (workload, situation awareness) will be needed when the human integrates into these systems. Predictive models that estimate the impact of the technologies on the system performance and the on the human operator are also needed to meet the challenges associated with such future complex human-automation-robot systems in extreme environments.

workload↗