At least 91 records · Page 5

Constant-temperature hot-wire anemometer practice in supersonic flows. II - The inclined wire

The performance of a constant-temperature inclined hot-wire in a supersonic flow is critically examined. It is shown that calibration techniques applicable to subsonic flow, such as the cosine cooling law cannot be used when the flow is supersonic. Calibration and measurement procedures appropriate to supersonic flow are suggested, together with the possible limits on their validity. Experimental results for different wires indicate that the sensitivities do not seem to depend on flow direction according to any simple correlation. When the sensitivity exhibits a strong dependence on flow direction, the wire should be discarded to avoid errors due to nonlinear effects.

Smits, A. J.↗

A high-performance constant-temperature hot-wire anemometer

A high-performance constant-temperature hot-wire anemometer has been designed based on a system theory analysis that can be extended to arbitrary order. A motivating factor behind the design was to achieve the highest possible frequency response while ensuring overall system stability. Based on these considerations, the design of the circuit and the selection of components is discussed in depth. Basic operating instructions are included in an operator's guide. The analysis is used to identify operating modes, observed in all anemometers, that are misleading in the sense that the operator can be deceived by interpreting an erroneous frequency response. Unlike other anemometers, this instrument provides front panel access to all the circuit parameters which affect system stability and frequency response. Instructions are given on how to identify and avoid these rather subtle and undesirable operating modes by appropriate adjustment of the controls. Details, such as fabrication drawings and a parts list, are provided to enable others to construct the instrument.

Watmuff, Jonathan H.↗

Calibration of Hot Wire Anemometers. (Latest Citations from the Aerospace Database)

The bibliography contains citations concerning calibration methods and measurement correction schemes for hot wire anemometers. Coverage includes static and dynamic calibration of sensors having single, multiple, cross, and ring wire configurations. Correction methods to account for yaw angle, low-velocity flow, microgravity, wall proximity, and highly fluctuating turbulence, velocity, or temperature are covered. Correction methods are also referenced for installations having multiple sensors. Hot film and laser anemometers, and the use of anemometers in specific industrial and aerospace applications are extensively covered in separate biblographies. (Contains 50-250 citations and includes a subject term index and title list.)

HOT WIRE ANEMOMETERS↗

Additive manufacturing enabled hot-wire apparatus with suppressed edge effect error

This invention describes a method of structuring a metal or metal coated wire in a manner such that it provides enhanced accuracy when used in a hot-wire apparatus for transient thermal conductivity measurements for low-density materials. This is accomplished by using a diameter varying structure with two ends of the wire of sufficiently small diameter that the edge-effect induced error can be reduced by generating a more uniform temperature profile along the wire, whereas in conventional apparatus the temperatures always drop at the ends of a finite wire due to its ends that are being cooled by the wire-supports.

36 MATERIALS SCIENCE↗

The Analysis of Turbulent Flow by Hot Wire Signals

When measuring velocities in turbulent gas flow, approximation signal analysis with hot wire anemometers having one and two wire probes are used. A numeric test of standard analyses shows the resulting systemmatic error increases quickly with increasing turbulent intensity. Since it also depends on the turbulence structure, it cannot be corrected. The use of such probes is thus restricted to low turbulence. By means of three wire probes (in two dimensional flows with X wire probes) in principle, instantaneous values of velocity can be determined, and an asymmetric arrangement of wires has a theoretical advantage.

Bartenwerfer, M.↗

Hybrid approach to data reduction for multi-sensor hot wires

A hybrid approach to implementing the calibration equations for a multisensor hot-wire probe is discussed. The approach combines some of the speed of a look-up approach with the moderate storage requirements of direct calculation based on functional fitting. Particular attention is given to timing and storage comparisons for an X-wire probe. The method depends on the oft-employed concept of an effective cooling velocity which is a function only of the bridge output voltage.

Hooper, C. L.↗

Constant temperature hot wire anemometry data reduction procedure

The theory and data reduction procedure for constant temperature hot wire anemometry are presented. The procedure is valid for all Mach and Prandtl numbers, but limited to Reynolds numbers based on wire diameter between 0.1 and 300. The fluids are limited to gases which approximate ideal gas behavior. Losses due to radiation, free convection and conduction are included.

Klopfer, G. H.↗

Hot-wire anemometry for in-flight measurement of aircraft wake vortices

An airborne hot-wire anemometry system capable of providing data concerning the vortex structure in the wake of a preceding aircraft has been used in several flight studies. The design features of this technique and the operational experience with it are described. This development program has resulted in a flight-test technique that can make accurate velocity measurements in flow regimes where large velocity gradients occur.

Jacobsen, R. A.↗

Gravitationally defined velocities for a low speed hot-wire calibration

A technique to provide the reference velocity for a low speed hot-wire calibration is described. A pivoted arm falls under the action of gravity and the resulting velocity field can be used to define the transfer function coefficients in a modified Collis and Williams (1959) relationship. In nominal agreement with a published result, a deviation from this relationship for a film Reynolds number such that Re exp n of less than about 0.24 is observed.

Haw, R. C.↗

Frequency Responses Of Hot-Wire Anemometers

Report describes theoretical study of frequency response of constant-temperature hot-wire anemometer, with view toward increasing frequency response while maintaining stable operation in supersonic flow. Effects of various circuit parameters discussed.

Watmuff, Jonathan H.↗

Hot-wire anemometry for turbulence measurements in helium-air mixtures

The use of extended hot-wire anemometry involving an interfering probe is shown to permit measurements of variable density turbulence such as arises in the mixing of helium and air. The methods of calibration and data reduction leading to time series in one or more velocity components, in the mass fraction of helium, and in the mixture density are described. Typical results in various flows to which the technique has been applied are discussed.

Libby, P. A.↗

Constant-Operating-Resistance Hot-Wire Probe

Effects of lead-wire-resistance changes with temperature nullified. Constant-operating-resistance hot-wire probe uses two sets of leads. Exposed to identical conditions, comparison of resistance gives change in sensing element itself. Data taken in more convenient manner, with advantage of not having to constantly check for possible changes in lead resistance and consequently readjust potentiometer.

Stainback, P. C.↗