Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high field sensitivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A full-ring variable-aperture cadmium zinc telluride system for whole-body single photon emission computed tomography: realistic simulations with phantoms

Single photon emission computed tomography (SPECT) is an imaging modality that has demonstrated its utility in a number of clinical indications. Despite this progress, a high sensitivity, high spatial resolution, multi-tracer SPECT with a large field of view suitable for whole-body imaging of a broad range of radiotracers for theranostics is not available. Purpose We have designed a cadmium zinc telluride (CZT) variable-aperture full-ring SPECT scanner instrumented with a broad-energy tungsten collimator intended to fill this technological gap. The final purpose is to provide a multi-tracer solution for brain and whole-body imaging. Our static SPECT scanner breaks the paradigm of the standard dual- and triple-head rotational SPECT systems, utilizing a larger detector area in each scan increasing the sensitivity. We provide a demonstration of the performance of our design using a realistic model of our detector with simulated body-sized 99mTc phantoms. Methods We developed a realistic model of our detector by using a combination of a Geant4 Monte Carlo simulation and a CZT detector response model based on a finite element model. Our approach models the characteristic low-energy tail effect in CZT that noticeably affects the sensitivity and the quality of the scatter correction in CZT detectors. We implement a modified dual energy window scatter correction adapted to include the CZT low-energy tail effect. A dedicated correction is also developed to eliminate the undesirable truncation observed in images given the presence of detector edges and gaps between detectors, due to the non-rotational nature of our device. Corrections for the attenuation, detector response and the presence of collimators are also included. The images are reconstructed using the maximum-likelihood expectation-maximization algorithm implemented in the reconstruction open software STIR. Detector and reconstruction performance are characterized with a Derenzo phantom and a body-sized National Electrical Manufacturers Association (NEMA) Image Quality (IQ) phantom containing 99mTc. Results Our SPECT design can resolve 6.4mm rods in a Derenzo phantom and obtain a good image contrast with the IQ phantom. Explicit testing of the gap and edge correction is provided, showing an excellent performance in eliminating the image truncation artifacts. Our modified scatter correction shows no overestimation of the contrast-recovery ratio for our realistic CZT detector model, as opposed to the cases without correction and with a standard dual-energy window scatter correction. Conclusions In this paper, we further demonstrate the performance of our design for whole-body imaging purposes. This adds to our previous demonstration of improved qualitative and quantitative 99mTc imaging for brain perfusion and 123I imaging for dopamine transport with respect to state-of-the-art NaI dual-head cameras. We show that our design performs similarly to the VERITON SPECT from Spectrum Dynamics, a commercial full-ring CZT SPECT camera, with the potential advantage of the broader energy range of application given by our custom-design tungsten collimators. Here, our device combines high sensitivity and image resolution with a broad-energy imaging application for the purpose of clinical imaging and theranostics of emerging radionuclides.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concept of Very-Asymmetric lepton Collider for dark matter search

Accelerator-based searches for dark matter are aiming for high sensitivity and need an experimental setup with high luminosity. This field of research is often called intensity frontier physics. One of the best motivated portals of interaction between dark matter and ordinary matter is a dark photon which could be observed as a resonance in the invariant mass of the decay products. Electron–positron collisions are known to be the cleanest interaction for such a study. In this paper we propose a scheme for a collider which allows for a luminosity of a few orders of magnitude higher than could be obtained in a conventional symmetric collider and with a few times higher accessible mass than is possible using a positron beam and a fixed target approach. The key concept is based on asymmetric energies: a high-energy circulating positron beam and a low-energy high-intensity electron beam, and optimization of the beam interaction region. We present here a configuration of a collision region of 10 MeV electron and 4 GeV positron beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy-resolved fast-neutron radiography using an event-mode neutron imaging detector

Energy-resolved fast-neutron radiography is a powerful non-destructive technique that can be used to remotely measure the quantity and distribution of elements and isotopes in a sample. This is done by comparing the energy-dependent neutron transmission of a sample with the known cross-sections of individual isotopes. The reconstruction of the composition is possible due to the unique features (e.g. resonances) in the cross-sections of individual isotopes. At short-pulsed (≲ 1 ns) neutron sources, such information is accessible via time-of-flight neutron imaging in principle, but requires a detector with nanosecond temporal resolution. Conventional neutron detectors can meet this requirement only by heavily compromising spatial resolution or efficiency. Here, we present a unique approach on fast neutron resonance radiography using a scintillator-based event-mode imaging detector at a short-pulsed neutron source, including first results on spatially mapped resonance profiles using MeV neutrons. The event mode approach applied in the presented detector allows recording of individual neutron interactions with nanosecond precision in time and sub-mm resolution in space. As a result, the entire available neutron energy spectrum can be measured for each pulse. At the same time, the use of a thick scintillator screen and lenses to focus the produced light results in a highly flexible field of view and a high interaction probability in the sensitive volume of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Primordial black hole dark matter: A quantitative parameter sensitivity comparison across formation mechanisms and particle candidates

Primordial black holes (PBHs) in the asteroid-mass window ( 10 17 – 10 22 g ) can account for all of the dark matter without violating any observational constraint, yet are routinely dismissed as fine-tuned. I put that dismissal to the test by applying three complementary sensitivity measures uniformly across a broad landscape: three noninflationary PBH production mechanisms, six classes of inflationary PBH models, and seven particle dark matter benchmarks, all evaluated against the same observable target. Three distinct naturalness universality classes emerge, determined entirely by the analytic structure of the abundance map rather than by the nature of the dark matter candidate. Biased-domain-wall PBHs, in their least model-dependent (free- V b ) form, have the same low sensitivity, Δ = 4.5 , as off-resonance weakly interacting massive particles and freeze-in particles ( Δ = 2 ), a sensitivity that, because it is constant over the entire parameter space of the construction, also coincides trivially with its own Wilson-normalized average within that parameter space (Section Definition and conventions), an equivalence that concerns only the space over which Δ is computed and is not a naturalness statement about the construction as a whole; a further reduction to Δ = 2 is possible only under the additional, independently motivated but not required, assumption that the domain-wall bias is generated by Planck-suppressed operators; early matter-domination PBHs occupy an intermediate tier alongside coannihilating weakly interacting massive particles (WIMPs), unified by a structural identity in which the sensitivity measure equals the logarithm of the ratio of the formation scale to the matter–radiation equality scale; first-order phase transition PBHs, once the more accurate super-exponential collapse probability is used in place of the single-exponential approximation, instead belong to the same highly sensitive tier as resonant WIMP annihilation and single-field inflationary collapse, for a structurally distinct reason; single-field ultraslow-roll inflationary collapse is severely tuned for a distinct reason: a double exponential in which the power spectrum amplitude is itself exponentially sensitive to the inflaton potential coefficients, on top of the exponential collapse sensitivity of the abundance map. My main conclusion is that the claim that PBH dark matter is generically fine-tuned conflates the worst case with a landscape spanning every naturalness tier. The Barbieri-Giudice sensitivity computed here and the Wilson-normalized measure of Iovino and Riotto answer distinct and mutually consistent questions about the same construction, a distinction I clarify within the two-layer decomposition.

Profumo, Stefano [University of California, Santa ↗

Pipeline Monitoring Using Highly Sensitive Vibration Sensor Based on Fiber Ring Cavity Laser

A vibration fiber sensor based on a fiber ring cavity laser and an interferometer based single-mode-multimode-single-mode (SMS) fiber structure is proposed and experimentally demonstrated. The SMS fiber sensor is positioned within the laser cavity, where the ring laser lasing wavelength can be swept to an optimized wavelength using a simple fiber loop design. To obtain a better signal-to-noise ratio, the ring laser lasing wavelength is tuned to the maximum gain region biasing point of the SMS transmission spectrum. A wide range of vibration frequencies from 10 Hz to 400 kHz are experimentally demonstrated. In addition, the proposed highly sensitive vibration sensor system was deployed in a field-test scenario for pipeline acoustic emission monitoring. An SMS fiber sensor is mounted on an 18” diameter pipeline, and vibrations were induced at different locations using a piezoelectric transducer. The proposed method was shown to be capable of real-time pipeline vibration monitoring.

47 OTHER INSTRUMENTATION↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Electrochemically decorated gold nanoparticles on CVD graphene ChemFET sensor for the highly sensitive detection of As(III)

Here, in this paper, we report a novel reusable receptor-free chemically sensitive field-effect transistor (ChemFET) sensor for the sensitive detection of As(III) using electrochemical doping of Au nanoparticles (AuNPs)-chemical vapour deposition (CVD) graphene (Gr) sensing film (AuNPs-Gr). The sensor consists of a single-gap gold electrode and a single layer of CVD graphene as a conducting/sensing channel decorated with a thin layer of electrochemically deposited AuNPs to catalyze the electroreduction of As(III) ions onto the sensing channel. A new detection strategy was proposed by measuring the resistance change rate of the AuNPs-Gr sensing channel modified between the source electrode and drain electrode, wherein the resistance change was caused by the electrochemical doping of As(0). The results indicated that the electrochemical doping of As(0) onto the sensing channel led to an increase in resistance through the doping interaction among As(0), AuNPs and graphene, enabling the proposed sensor to have an extraordinary detection performance with a high sensitivity. Moreover, the proposed sensor can be recycled by removing the As(0) deposited on the sensing film with the aid of a simple electrochemical oxidization process. Additionally, the mechanism of the sensing strategy based on the electrochemical n-doping of As(0) into the AuNPs-Gr sensing film was investigated using a top liquid gate electrode. The As(III) concentration detected by the AuNPs-Gr ChemFET sensor was as low as 0.001 μg/L, demonstrating that such sensors with a compatible sensing strategy can be used to detect As(III) with high sensitivity, easy fabrication, fast response and can be recycled.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantum Imaging of Ferromagnetic van der Waals Magnetic Domain Structures at Ambient Conditions

Recently discovered 2D van der Waals magnetic materials, and specifically iron–germanium–telluride (Fe5GeTe2), have attracted significant attention both from a fundamental perspective and for potential applications. Key open questions concern their domain structure and magnetic phase transition temperature as a function of sample thickness and external field, as well as implications for integration into devices such as magnetic memories and logic. Here we address key questions using a nitrogen-vacancy center based quantum magnetic microscope, enabling direct imaging of the magnetization of Fe5GeTe2 at submicrometer spatial resolution as a function of temperature, magnetic field, and thickness. This quantum imaging technique provides noninvasive, high-sensitivity measurements with high spatial resolution under ambient conditions, making it particularly well suited for probing 2D magnets. We employ spatially resolved measures, including magnetization variance and cross-correlation, and find a significant spread in transition temperature yet with no clear dependence on thickness down to 15 nm. We also identify previously unknown stripe features in the optical as well as magnetic images, which we attribute to modulations of the constituting elements during crystal synthesis and subsequent oxidation. Our results suggest that the magnetic anisotropy in this material does not play a crucial role in their magnetic properties, leading to a magnetic phase transition of Fe5GeTe2 which is largely thickness-independent down to 15 nm. Our findings could be significant in designing future spintronic devices, magnetic memories, and logic with 2D van der Waals magnetic materials.

Bindu, Bindu [Hebrew University of Jerusalem, Isra↗

Modeled sensitivity of multi-MA accelerator performance to electrode contaminant inventory

Significant particle-in-cell code development has enabled simulations of power flow in multi-MA accelerators to include the desorption of surface contaminants, their ionization into surface plasmas, and the impact of these plasmas on efficiency. The simulations base desorption on an Arrhenius equation, whose most significant unknown is the surface contaminant inventory. The sensitivity of power-flow simulations to this inventory is studied here using Sandia National Laboratories' Z accelerator with a 7-nH MagLIF load [Phys. Plasmas 17, 056303 (2010)]. Simulations are conducted in 3D cylindrical coordinates for the current-adder, or “convolute,” region of Z and in 2D for the final feed only. Simulated contaminant inventories are varied from 1 to 32 monolayers (MLs) in 2D, and 2 to 4 ML in 3D. The results reveal sensitivities to the local ratio of E/B⁠. The high B-field, low E-field region near the short-circuit load is insensitive to the contaminant inventory, where assumed values of 4–32 ML change the load current by ≤ 2%, and agree with experiment to within 2% at peak current. A 1-ML value is the outlier, increasing the load current by 5%, but still within measurement uncertainty. In contrast, the relatively higher E-field, lower B-field convolute region has slower contaminant desorption and higher-magnitude E-field penetration of the surface plasmas. The current loss in the convolute region does increase with contaminant inventory. The loss assuming 4 ML is 12% larger than for 2 ML, with 4 ML being the better match to experiment.

Arrhenius equation↗

Density weighted angular redshift fluctuations: a new cosmological observable

We propose the use of angular fluctuations in the galaxy redshift field as a new way to extract cosmological information in the Universe. This new probe $\delta z (\hat{\mathbf {n}})$ consists of the statistics of sky maps built by projecting redshifts under a Gaussian window of width σz centred upon a redshift zobs, and weighted by the galaxy density field. We compute the angular power spectrum of the $\delta z (\hat{\mathbf {n}})$ field in both numerical simulations and in linear perturbation theory. From these, we find that the $\delta z (\hat{\mathbf {n}})$ field (i) is sensitive to the underlying density and peculiar velocity fields; (ii) is highly correlated, at the $\gtrsim 60\, {{\ \rm per\ cent}}$ level, to the line-of-sight projected peculiar velocity field; (iii) for narrow windows (σz < 0.03), it is almost completely uncorrelated to the projected galaxy angular density field under the same redshift window; and (iv) it is largely unaffected by multiplicative and additive systematic errors on the observed number of galaxies that are redshift-independent over ~σz. We conclude that $\delta z (\hat{\mathbf {n}})$ is a simple and robust tomographic measure of the cosmic density and velocity fields, complementary to angular clustering, that will contribute to more complete exploitations of current and upcoming galaxy redshift surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Simultaneous Brillouin and piezoelectric coupling to a high-frequency bulk acoustic resonator

Bulk acoustic resonators support robust, long-lived mechanical modes, capable of coupling to various quantum systems. In separate works, such devices have achieved strong coupling to both superconducting qubits, via piezoelectricity, and optical cavities, via Brillouin interactions. In this work, we present a hybrid microwave–optical platform capable of coupling to bulk acoustic waves through cavity-enhanced piezoelectric and photoelastic interactions. The modular, tunable system achieves fully resonant and well-mode-matched interactions among a 3D microwave cavity, a high-frequency bulk acoustic resonator, and a Fabry–Perot cavity. We realize this piezo–Brillouin interaction in x-cut quartz, demonstrating the potential for strong optomechanical interactions and high cooperativity using optical cavity enhancement. We further show how this device functions as a bidirectional electro–opto–mechanical transducer, with transduction efficiency exceeding 10 − <#comment/> 8 , and a feasible path towards unity conversion efficiency. The high optical sensitivity and ability to apply a large resonant microwave field in this system also offers a tool for probing anomalous electromechanical couplings, which we demonstrate by investigating (nominally centrosymmetric) C a F 2 and revealing a parasitic piezoelectricity of 83 am/V. Such studies are an important topic for emerging quantum technologies, and highlight the versatility of this hybrid platform.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency Comb-Based Remote Methane Observation Network (Final Scientific/Technical Report)

ARPA-E investment in long-range, frequency comb-based methane detection has resulted in the first scalable, cost-effective continuous methane emissions system. At the onset of this ARPA-E MONITOR award, the dual-frequency comb spectrometer was a sprawling, expensive, laboratory-confined device which had only recently been demonstrated capable of measuring atmospheric trace gases over open-paths. Bringing the technology to the point of being able to monitor for and characterize methane emissions at oil and natural gas production facilities seemed an almost impossible task. Over the subsequent months and years, our team transitioned the Nobel-prize-winning frequency-comb-laser spectrometer technology to a field-deployed regional methane leak detection system. The spectrometer enables highly sensitive near-infrared absorption measurements of methane along kilometer-scale laser beam paths. The measurements are coupled with an atmospheric modeling and inversion framework to triangulate the location of emission sources and quantify the emission rates.

03 NATURAL GAS↗

High Q SRF cavity-based searches for beyond the standard model physics

The SRF technology developed for accelerators can be successfully applied to new applications, including quantum computing, dark matter searches and beyond the standard model physics. The ultra-high quality factor of SRF cavities can enable unprecedented sensitivity in fields outside of the usual accelerator applications, for examples fundamental and beyond the standard model physics. Applications of SRF cavities for gravitational waves searches are also being investigated. The SQMS Physics and Sensing thrust is working on this effort as it strives to combine SRF cavities with QIS, with a focus on BSM and fundamental physics.

Berlin, A.↗

XRISM Constraints on Unidentified X-Ray Emission Lines, Including the 3.5 keV Line, in the Stacked Spectrum of 10 Galaxy Clusters

We stack 3.75 Ms of early XRISM Resolve observations of 10 galaxy clusters to search for unidentified spectral lines in the E = 2.5–15 keV band (rest frame), including the E = 3.5 keV line reported in earlier low spectral resolution studies of cluster samples. Such an emission line may originate from the decay of the sterile neutrino, a warm dark matter (DM) candidate. No unidentified lines are detected in our stacked cluster spectrum, with the 3σ upper limit on the m s ∼ 7.1 keV DM particle decay rate (which corresponds to an E = 3.55 keV emission line) of Γ ∼ 1.0 × 10 −27 s −1 . This upper limit is 3–4 times lower than the one derived by Hitomi Collaboration from the Perseus observation but still 5 times higher than the XMM-Newton detection reported by E. Bulbul et al. in the stacked cluster sample. XRISM Resolve, with its high spectral resolution but small field of view, may reach the sensitivity needed to test the XMM-Newton cluster sample detection by combining several years worth of future cluster observations.

Astronomy and AstroPhysics↗

Quantitative comparisons of electron-scale turbulence measurements in NSTX via synthetic diagnostics for high-k scattering.

Two synthetic diagnostics are implemented for the high-k scattering system in NSTX [D. R. Smith, E. Mazzucato, W. Lee, H. K. Park, C. W. Domier, and N. C. Luhmann Jr., Rev. Sci. Instrum., 79, 123501 (2008)] allowing direct comparisons between synthetic and experimentally detected frequency and wavenumber spectra of electron-scale turbulence fluctuations. Synthetic diagnostics were formulated in real-space and in wavenumber space, and were deployed to realistic electron-scale simulations carried out with the GYRO code [J. Candy and R. E. Waltz, J. Comput. Phys. 186 (2003) 545]. A highly unstable ETG regime (electron temperature gradient mode) in a modest beta NSTX NBI-heated H-mode discharge was chosen for the analysis. Mapping the measured wavenumbers to field aligned coordinates showed that the high-k system is sensitive to fluctuations that are closer to the spectral peak in the density fluctuation wavenumber spectrum (streamers) than originally predicted. Analysis of synthetic spectra show that the frequency response of the detected fluctuations is dominated by Doppler shift and insensitive to the turbulence drive. The shape of the high-k density fluctuation wavenumber spectrum is sensitive to the ETG turbulence drive conditions, and can be reproduced in a sensitivity scan of the most pertinent turbulent drive terms in the simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Uni-layer magnets: a new concept for LTS and HTS based superconducting magnets

A novel geometrical configuration to form a magnetic field perpendicular to an aperture, created by an asymmetric current distribution, within a single layer, and using a continuous ideal current line, named the uni-layer (UL) magnet, is here presented. The idea is compared to existing concepts in superconducting magnets, namely, the $\cos{\theta}$ sector magnet, stress managed $\cos{\theta}$ and canted $\cos{\theta}$. The UL magnet allows for a design with a continuous unit length (no layer jump), and an increased minimum bending radius of the conductor in relation to traditional $\cos{\theta}$ and canted $\cos{\theta}$ designs. Further, the specific characteristics of the UL design are especially advantageous for strain-sensitive and prone to winding degradation high-temperature superconductors, in very high field accelerator magnet applications, in which, high efficiency in the use of conductor, and a small aperture are required. The advantages with regard to the design and fabrication of UL magnets in relation to other concepts are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗