Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heterogeneous benchmark”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of the INSTANT-HPS PN Transport Code to the C5G7 Benchmark Problem

INSTANT is the INL's next generation neutron transport solver to support high-fidelity multi-physics reactor simulation INSTANT is in continuous development to extend its capability Code is designed to take full advantage of middle to large cluster (10-1000 processors) Code is designed to focus on method adaptation while also mesh adaptation will be possible. It utilizes the most modern computing techniques to generate a neutronics tool of full-core transport calculations for reactor analysis and design. It can perform calculations on unstructured 2D/3D triangular, hexagonal and Cartesian geometries. Calculations can be easily extended to more geometries because of the independent mesh framework coded with the model Fortran. This code has a multigroup solver with thermal rebalance and Chebyshev acceleration. It employs second-order PN and Hybrid Finite Element method (PNHFEM) discretization scheme. Three different in-group solvers - preconditioned Conjugate Gradient (CG) method, preconditioned Generalized Minimal Residual Method (GMRES) and Red-Black iteration - have been implemented and parallelized with the spatial domain decomposition in the code. The input is managed with extensible markup language (XML) format. 3D variables including the flux distributions are outputted into VTK files, which can be visualized by tools such as VisIt and ParaView. An extension of the code named INSTANTHPS provides the capability to perform 3D heterogeneous transport calculations within fuel pins. C5G7 is an OECD/NEA benchmark problem created to test the ability of modern deterministic transport methods and codes to treat reactor core problems without spatial homogenization. This benchmark problem had been widely analyzed with various code packages. In this transaction, results of the applying the INSTANT-HPS code to the C5G7 problem are summarized.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast multipurpose Monte Carlo simulation for proton therapy using multi- and many-core CPU architectures

Purpose: Accuracy in proton therapy treatment planning can be improved using Monte Carlo (MC) simulations. However the long computation time of such methods hinders their use in clinical routine. This work aims to develop a fast multipurpose Monte Carlo simulation tool for proton therapy using massively parallel central processing unit (CPU) architectures. Methods: A new Monte Carlo, called MCsquare (many-core Monte Carlo), has been designed and optimized for the last generation of Intel Xeon processors and Intel Xeon Phi coprocessors. These massively parallel architectures offer the flexibility and the computational power suitable to MC methods. The class-II condensed history algorithm of MCsquare provides a fast and yet accurate method of simulating heavy charged particles such as protons, deuterons, and alphas inside voxelized geometries. Hard ionizations, with energy losses above a user-specified threshold, are simulated individually while soft events are regrouped in a multiple scattering theory. Elastic and inelastic nuclear interactions are sampled from ICRU 63 differential cross sections, thereby allowing for the computation of prompt gamma emission profiles. MCsquare has been benchmarked with the GATE/GEANT4 Monte Carlo application for homogeneous and heterogeneous geometries. Results: Comparisons with GATE/GEANT4 for various geometries show deviations within 2%–1 mm. In spite of the limited memory bandwidth of the coprocessor simulation time is below 25 s for 10{sup 7} primary 200 MeV protons in average soft tissues using all Xeon Phi and CPU resources embedded in a single desktop unit. Conclusions: MCsquare exploits the flexibility of CPU architectures to provide a multipurpose MC simulation tool. Optimized code enables the use of accurate MC calculation within a reasonable computation time, adequate for clinical practice. MCsquare also simulates prompt gamma emission and can thus be used also for in vivo range verification.

60 APPLIED LIFE SCIENCES↗

SU-C-BRC-03: Development of a Novel Strategy for On-Demand Monte Carlo and Deterministic Dose Calculation Treatment Planning and Optimization for External Beam Photon and Particle Therapy

Purpose: Accurate and fast dose calculation is a prerequisite of precision radiation therapy in modern photon and particle therapy. While Monte Carlo (MC) dose calculation provides high dosimetric accuracy, the drastically increased computational time hinders its routine use. Deterministic dose calculation methods are fast, but problematic in the presence of tissue density inhomogeneity. We leverage the useful features of deterministic methods and MC to develop a hybrid dose calculation platform with autonomous utilization of MC and deterministic calculation depending on the local geometry, for optimal accuracy and speed. Methods: Our platform utilizes a Geant4 based “localized Monte Carlo” (LMC) method that isolates MC dose calculations only to volumes that have potential for dosimetric inaccuracy. In our approach, additional structures are created encompassing heterogeneous volumes. Deterministic methods calculate dose and energy fluence up to the volume surfaces, where the energy fluence distribution is sampled into discrete histories and transported using MC. Histories exiting the volume are converted back into energy fluence, and transported deterministically. By matching boundary conditions at both interfaces, deterministic dose calculation account for dose perturbations “downstream” of localized heterogeneities. Hybrid dose calculation was performed for water and anthropomorphic phantoms. Results: We achieved <1% agreement between deterministic and MC calculations in the water benchmark for photon and proton beams, and dose differences of 2%–15% could be observed in heterogeneous phantoms. The saving in computational time (a factor ∼4–7 compared to a full Monte Carlo dose calculation) was found to be approximately proportional to the volume of the heterogeneous region. Conclusion: Our hybrid dose calculation approach takes advantage of the computational efficiency of deterministic method and accuracy of MC, providing a practical tool for high performance dose calculation in modern RT. The approach is generalizable to all modalities where heterogeneities play a large role, notably particle therapy.

60 APPLIED LIFE SCIENCES↗

Monte Carlo study of LDR seed dosimetry with an application in a clinical brachytherapy breast implant

A Monte Carlo (MC) study was carried out to evaluate the effects of the interseed attenuation and the tissue composition for two models of {sup 125}I low dose rate (LDR) brachytherapy seeds (Medi-Physics 6711, IBt InterSource) in a permanent breast implant. The effect of the tissue composition was investigated because the breast localization presents heterogeneities such as glandular and adipose tissue surrounded by air, lungs, and ribs. The absolute MC dose calculations were benchmarked by comparison to the absolute dose obtained from experimental results. Before modeling a clinical case of an implant in heterogeneous breast, the effects of the tissue composition and the interseed attenuation were studied in homogeneous phantoms. To investigate the tissue composition effect, the dose along the transverse axis of the two seed models were calculated and compared in different materials. For each seed model, three seeds sharing the same transverse axis were simulated to evaluate the interseed effect in water as a function of the distance from the seed. A clinical study of a permanent breast {sup 125}I implant for a single patient was carried out using four dose calculation techniques: (1) A TG-43 based calculation, (2) a full MC simulation with realistic tissues and seed models, (3) a MC simulation in water and modeled seeds, and (4) a MC simulation without modeling the seed geometry but with realistic tissues. In the latter, a phase space file corresponding to the particles emitted from the external surface of the seed is used at each seed location. The results were compared by calculating the relevant clinical metrics V{sub 85}, V{sub 100}, and V{sub 200} for this kind of treatment in the target. D{sub 90} and D{sub 50} were also determined to evaluate the differences in dose and compare the results to the studies published for permanent prostate seed implants in literature. The experimental results are in agreement with the MC absolute doses (within 5% for EBT Gafchromic film and within 7% for TLD-100). Important differences between the dose along the transverse axis of the seed in water and in adipose tissue are obtained (10% at 3.5 cm). The comparisons between the full MC and the TG-43 calculations show that there are no significantdifferences for V{sub 85} and V{sub 100}. For V{sub 200}, 8.4% difference is found coming mainly from the tissue composition effect. Larger differences (about 10.5% for the model 6711 seed and about 13% for the InterSource{sup 125}) are determined for D{sub 90} and D{sub 50}. These differences depend on the composition of the breast tissue modeled in the simulation. A variation in percentage by mass of the mammary gland and adipose tissue can cause important differences in the clinical dose metrics V{sub 200}, D{sub 90}, and D{sub 50}. Even if the authors can conclude that clinically, the differences in V{sub 85}, V{sub 100}, and V{sub 200} are acceptable in comparison to the large variation in dose in the treated volume, this work demonstrates that the development of a MC treatment planning system for LDR brachytherapy will improve the dose determination in the treated region and consequently the dose-outcome relationship, especially for the skin toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung

Purpose: To compare analytic and Monte Carlo–based algorithms for proton dose calculations in the lung, benchmarked against anthropomorphic lung phantom measurements. Methods and Materials: A heterogeneous anthropomorphic moving lung phantom has been irradiated at numerous proton therapy centers. At 5 centers the treatment plan could be calculated with both an analytic and Monte Carlo algorithm. The doses calculated in the treatment plans were compared with the doses delivered to the phantoms, which were measured using thermoluminescent dosimeters and film. Point doses were compared, as were planar doses using a gamma analysis. Results: The analytic algorithms overestimated the dose to the center of the target by an average of 7.2%, whereas the Monte Carlo algorithms were within 1.6% of the physical measurements on average. In some regions of the target volume, the analytic algorithm calculations differed from the measurement by up to 31% in the internal gross target volume (iGTV) (46% in the planning target volume), over-predicting the dose. All comparisons showed a region of at least 15% dose discrepancy within the iGTV between the analytic calculation and the measured dose. The Monte Carlo algorithm recalculations showed dramatically improved agreement with the measured doses, showing mean agreement within 4% for all cases and a maximum difference of 12% within the iGTV. Conclusions: Analytic algorithms often do a poor job predicting proton dose in lung tumors, over-predicting the dose to the target by up to 46%, and should not be used unless extensive validation counters the consistent results of the present study. Monte Carlo algorithms showed dramatically improved agreement with physical measurements and should be implemented to better reflect actual delivered dose distributions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forensic characterization of surrogate nuclear explosion debris: radiochemical and spectroscopic strategies for method validation

Surrogate nuclear explosion debris (SNED) has emerged as a critical platform for advancing post-detonation nuclear forensic analysis in the absence of readily accessible historic materials. SNED enables controlled investigation and validation of analytical methodologies used to interrogate the chemical, isotopic, radiological, and microstructural signatures preserved in nuclear explosion debris. This review presents an integrated assessment of destructive and non-destructive analytical techniques commonly employed within decision-driven nuclear forensic workflows. Each technique is discussed individually while highlighting how it contributes to different stages of post-detonation analysis. Core methods – including gamma and alpha spectrometry, ICP-MS, TIMS, SIMS, SEM-EDS, XRF, LIBS, vibrational spectroscopy, and X-ray absorption spectroscopy – are critically evaluated with respect to forensic maturity, information content, and matrix limitations. Emphasis is placed on the role of SNED in benchmarking multi-modal workflows and identifying gaps in reproducing heterogeneity, fractionation, and radiation-driven evolution relevant to forensic attribution.

X-ray spectroscopic methods↗

EXTENSION OF THE 1D FOUR-GROUP ANALYTIC NODAL METHOD TO FULL MULTIGROUP

In the mid 80’s, a four-group/two-region, entirely analytical 1D nodal benchmark appeared. It was readily acknowledged that this special case was as far as one could go in terms of group number and still achieve an analytical solution. In this work, we show that by decomposing the solution to the multigroup diffusion equation into homogeneous and particular solutions, extension to any number of groups is a relatively straightforward exercise using the mathematics of linear algebra.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experimental analysis of spatial correlation effects on capillary trapping of supercritical CO 2 at the intermediate laboratory scale in heterogeneous porous media

Several numerical studies have demonstrated that the heterogeneous nature of typical sedimentary formations can favorably dampen the accumulation of mobile CO 2 phase underneath the caprock. Core flooding experiments have also shown that contrasts in capillary entry pressure can lead to buildup of nonwetting fluid phase (NWP) at interfaces between facies. Explicit representation of geological heterogeneity at the intermediate (cm-to-m) scale is a powerful approach to identify the key mechanisms that control multiphase flow dynamics in porous media. The ability to carefully control flow regime and permeability contrast at a scale that is relevant to CO 2 plume dynamics in saline formations offers valuable information to understand immiscible displacement processes and provides a benchmark for mathematical models. To provide insight into the impact of capillary heterogeneity on flow dynamics and trapping efficiency of supercritical CO 2 under successive drainage and imbibition conditions, we present an experimental investigation conducted in a synthetic sand reservoir. By mimicking the interplay of governing forces at reservoir conditions via application of surrogate fluids, we performed three immiscible displacement experiments to observe the entrapment of NWP in heterogeneous porous media. Capillary trapping performance is evaluated for each scenario through spatial and temporal variations of NWP saturation; for this reason we adopted X-ray attenuation to precisely measure phase saturation throughout the flow domain and apply spatial moment analysis. Furthermore, the sweeping performance of two different permeability fields with comparable variance but distinct spatial correlation was compared against a homogeneous base case with equivalent mean permeability by means of spatial moment analysis.

58 GEOSCIENCES↗

MLCommons Science Benchmarks

Benchmarks are a cornerstone of modern machine learning practice, providing standardized eval- uations that enable reproducibility, comparison, and scientific progress. Yet, as AI systems particularly deep learning models become increasingly dynamic, traditional static benchmarking approaches are losing their relevance. Models rapidly evolve in architecture, scale, and capability; datasets shift; and deployment contexts continuously change, creating a moving target for evaluation. Without adaptive benchmarking frame- works, both scientific assessment and real-world de- ployment risk becoming misaligned with actual system behavior. Drawing on our experience from MLCommons, educa- tional initiatives, and government programs such as the DOE s Million Parameter Consortium, we identify key barriers that hinder the broader adoption and utility of benchmarking in AI. These include substantial resource demands, limited access to specialized hardware, lack of expertise in benchmark design, and uncertainty among practitioners about how to relate benchmark results to their own application domains. Moreover, current benchmarks often emphasize peak performance on leadership-class hardware, offering limited guidance for more diverse, real-world deployment scenarios. We argue that benchmarking itself must become dy- namic in order to incorporate evolving models, updated data, and heterogeneous computational platforms while maintaining transparency, reproducibility, and inter- pretability. Democratizing this process requires not only technical innovation, but also systematic educational efforts spanning undergraduate to professional levels to develop sustained expertise in benchmark design and use. Finally, benchmarks should be framed and com- municated to support application-relevant comparisons, enabling both developers and users to make informed, context-sensitive decisions. Advancing dynamic and inclusive benchmarking practices will be essential to ensure that evaluation keeps pace with the evolving AI landscape and supports responsible, reproducible, and accessible AI deployment.

Hawks, Benjamin G. [Fermilab]↗

Graph-Based Attention Mechanisms for Solving the AC Optimal Power Flow Problem in Electrical Power Networks

With the increasing complexity and data availability in modern power systems, learning-based approaches to AC Optimal Power Flow (AC OPF) have garnered significant attention. In particular, the structure of smart grids lends itself naturally to graph-based representations, where Graph Neural Networks (GNNs) can capture spatial and relational dependencies. This paper investigates attention-based GNN architectures tailored to heterogeneous graph representations of electric grids. We evaluate two major paradigms: relational attention, which distinguishes between edge types during message passing, and meta-path attention, which captures high-level semantics through multi-hop, typed paths. Using a large corpus of public AC OPF scenarios, we benchmark representative models of each type of attention. Our results demonstrate the benefits of heterogeneous attention-based models in accurately capturing grid dynamics; heterogeneous attention models achieve superior performance in both standard and perturbed settings. The findings highlight the importance of semantic-aware architectures for improving prediction robustness and interpretability in power system applications.

Trigui, Ali [Qubit Engineering Inc.]↗

A hybrid finite element-spectral boundary integral approach: Applications to dynamic rupture modeling in unbounded domains

The finite element method (FEM) and the spectral boundary integral method (SBI) have both been widely used in the study of dynamic rupture simulations along a weak interface. Here, we present a hybrid method that combines FEM and SBI through the consistent exchange of displacement and traction boundary conditions, thereby benefiting from the flexibility of FEM in handling problems with nonlinearities or small-scale heterogeneities and from the superior performance and accuracy of SBI. We validate the hybrid method using a benchmark problem from the Southern California Earthquake Center's dynamic rupture simulation validation exercises.We further demonstrate the capability and computational efficiency of the hybrid scheme for resolving off-fault heterogeneities by studying a 2D in-plane shear crack in two different settings: one where the crack is embedded in a high-velocity zone and another where it is embedded in a low-velocity zone. Finally, we discuss the potential of the hybrid method for addressing a wide range of problems in geophysics and engineering.

58 GEOSCIENCES↗

Heterogeneous CPU+GPU-Enabled Simulations for DFTB Molecular Dynamics of Large Chemical and Biological Systems

We introduce a new heterogeneous CPU+GPU-enhanced DFTB approach for the routine and efficient simulation of large chemical and biological systems. Here, compared to homogenous computing with conventional CPUs, heterogeneous computing approaches exhibit substantial performance with only a modest increase in power consumption, both of which are essential to upcoming exascale computing initiatives. We show that DFTB-based molecular dynamics is a natural candidate for heterogeneous computing since the computational bottleneck in these simulations is the diagonalization of the Hamiltonian matrix, which is performed several times during a single molecular dynamics trajectory. To thoroughly test and understand the performance of our heterogeneous CPU+GPU approach, we examine a variety of algorithmic implementations, benchmarks of different hardware configurations, and applications of this methodology on several large chemical and biological systems. Finally, to demonstrate the capability of our implementation, we conclude with a large-scale DFTB MD simulation of explicitly solvated HIV protease (3,974 atoms total) as a proof-of-concept example of an extremely large/complex system which, to the best of our knowledge, is the first time that an entire explicitly-solvated protein has been treated at a quantum-based MD level of detail.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating spectral cloud effective radius retrievals from the Enhanced MODIS Airborne Simulator (eMAS) during ORACLES

Satellite remote sensing retrievals of cloud effective radius (CER) are widely used for studies of aerosol–cloud interactions. Such retrievals, however, rely on forward radiative transfer (RT) calculations using simplified assumptions that can lead to retrieval errors when the real atmosphere deviates from the forward model. Here, coincident airborne remote sensing and in situ observations obtained during NASA's ObseRvations of Aerosols above CLouds and their intEractionS (ORACLES) field campaign are used to evaluate retrievals of CER for marine boundary layer stratocumulus clouds and to explore impacts of forward RT model assumptions and other confounding factors. Specifically, spectral CER retrievals from the Enhanced MODIS Airborne Simulator (eMAS) and the Research Scanning Polarimeter (RSP) are compared with polarimetric retrievals from RSP and with CER derived from droplet size distributions (DSDs) observed by the Phase Doppler Interferometer (PDI) and a combination of the Cloud and Aerosol Spectrometer (CAS) and the Two-Dimensional Stereo Probe (2D-S). The sensitivities of the eMAS and RSP spectral retrievals to assumptions about the DSD effective variance (CEV) and liquid water complex index of refraction are explored. CER and CEV inferred from eMAS spectral reflectance observations of the backscatter glory provide additional context for the spectral CER retrievals. The spectral and polarimetric CER retrieval agreement is case dependent, and updating the retrieval RT assumptions, including using RSP polarimetric CEV retrievals as a constraint, yields mixed results that are tied to differing sensitivities to vertical heterogeneity. Moreover, the in situ cloud probes, often used as the benchmark for remote sensing CER retrieval assessments, themselves do not agree, with PDI DSDs yielding CER values 1.3–1.6 µm larger than CAS and with CEV roughly 50 %–60 % smaller than CAS. Implications for the interpretation of spectral and polarimetric CER retrievals and their agreement are discussed.

Meyer, Kerry [NASA Goddard Space Flight Center (GS↗

The IAEA coordinated research programme on HTGR uncertainty analysis: Phase I status and Ex. I-1 prismatic reference results

The quantification of uncertainties in design and safety analysis of reactors is today not only broadly accepted, but in many cases became the preferred way to replace traditional conservative analysis for safety and licensing analysis. The use of a more fundamental methodology is also consistent with the reliable high fidelity physics models and robust, efficient, and accurate codes available today. To facilitate uncertainty analysis applications a comprehensive approach and methodology must be developed and applied, in contrast to the historical approach where sensitivity analysis were performed and uncertainties then determined by a simplified statistical combination of a few important input parameters. New methodologies are currently under development in the OECD/NEA Light Water Reactor (LWR) Uncertainty Analysis in Best-Estimate Modelling (UAM) benchmark activity. High Temperature Gas-cooled Reactor (HTGR) designs require specific treatment of the double heterogeneous fuel design and large graphite quantities at high temperatures. The IAEA has therefore launched a Coordinated Research Project (CRP) on HTGR Uncertainty Analysis in Modelling (UAM) in 2013 to study uncertainty propagation specifically in the HTGR analysis chain. Two benchmark problems are defined, with the prismatic design represented by the General Atomics (GA) MHTGR-350 and a 250 MW modular pebble bed design similar to the Chinese HTR-PM. Work has started on the first phase and the current CRP status is reported in the paper. A comparison of the Serpent and SCALE/KENO-VI reference Monte Carlo results for Ex. I-1 of the MHTGR-350 design is also included. It was observed that the SCALE/KENO-VI Continuous Energy (CE) k ∞ values were 395 pcm (Ex. I-1a) to 803 pcm (Ex. I-1b) higher than the respective Serpent lattice calculations, and that within the set of the SCALE results, the KENO-VI 238 Multi-Group (MG) k ∞ values were up to 800 pcm lower than the KENO-VI CE values. The use of the latest ENDF-B-VII.1 cross section library in Serpent lead to ~180 pcm lower k ∞ values compared to the older ENDF-B-VII.0 dataset, caused by the modified graphite neutron capture cross section. Furthermore, the fourth beta release of SCALE 6.2 likewise produced lower CE k∞ values when compared to SCALE 6.1, and the improved performance of the new 252-group library available in SCALE 6.2 is especially noteworthy. A SCALE/TSUNAMI uncertainty analysis of the Hot Full Power variant for Ex. I-1a furthermore concluded that the 238 U(n,γ) (capture) and 235 U(View the MathML source) cross-section covariance matrices contributed the most to the total k ∞ uncertainty of 0.58%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantum Electrodynamics Coupled-Cluster at Scale: High-Performance Implementation for Complex Systems

Coupled-cluster theory (CC) is a highly accurate and versatile method for simulating complex interactions within quantum systems. The extension of CC theory to model mixed electron-photon processes with quantum electrodynamics (QED) has improved our capability to predict cavity-modified chemistry, a field where photons are used as cost-effective and eco-friendly alternatives to catalyze/inhibit chemical reactions. However, calculations with CC methods, even without incorporating QED effects, are often prohibitively expensive. Simulations of larger systems require scalable infrastructures that exist for traditional CC methods but not for QED-CC methods. As such, we present a GPU-enabled, high-performance, open-source implementation of the quantum electrodynamics coupled-cluster method with single and double excitations (QED-CCSD) within the ExaChem quantum chemistry software package. ExaChem relies on the Tensor Algebra for Many-body Methods (TAMM) infrastructure: a parallel heterogeneous tensor library designed to achieve scalable performance on modern heterogeneous supercomputing platforms. Furthermore, we discuss theoretical foundations, algorithmic details, and numerical benchmarks to showcase the larger systems that ExaChem can simulate and how the integration of photonic degrees-of-freedom alters their ground-state properties.

Basis sets↗

Cell Dancoff-based embedded self-shielding capability for doubly heterogeneous particulate fuels in SCALE/Polaris

Polaris is a two-dimensional (2D) transport lattice physics capability in the SCALE code system for light-water reactor (LWR) analysis. SCALE/Polaris is being extended to treat doubly heterogeneous particulate fuels in LWRs with accident-tolerant fuels and prismatic high-temperature gas-cooled reactor (HTGR) fuel. Recently, a Dancoff-based Wigner-Seitz approximation capability based on the embedded self-shielding method (DWA-ESSM) was implemented into Polaris for efficient computation. A new double heterogeneity treatment capability based on DWA-ESSM in conjunction with the Hebert's collision probability method for double heterogeneity was developed and implemented for Polaris. The new capability was verified by performing benchmark calculations for the prismatic HTGR fuel compact problems with various design parameters through a code-to-code comparison between the Polaris and continuous-energy Monte Carlo results. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Analysis Framework for Investigating the Trade-offs Between System Performance and Energy Consumption in a Heterogeneous Computing Environment

Rising costs of energy consumption and an ongoing effort for increases in computing performance are leading to a significant need for energy-efficient computing. Before systems such as supercomputers, servers, and datacenters can begin operating in an energy-efficient manner, the energy consumption and performance characteristics of the system must be analyzed. In this paper, we provide an analysis framework that will allow a system administrator to investigate the tradeoffs between system energy consumption and utility earned by a system (as a measure of system performance). We model these trade-offs as a bi-objective resource allocation problem. We use a popular multi-objective genetic algorithm to construct Pareto fronts to illustrate how different resource allocations can cause a system to consume significantly different amounts of energy and earn different amounts of utility. We demonstrate our analysis framework using real data collected from online benchmarks, and further provide a method to create larger data sets that exhibit similar heterogeneity characteristics to real data sets. This analysis framework can provide system administrators with insight to make intelligent scheduling decisions based on the energy and utility needs of their systems.

Friese, Ryan↗