Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heterodyne”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Sensitivity Limitation of an Optical Heterodyne Spectrometer

We show an optical heterodyne spectrometer with picometer resolution and high sensitivity. Moreover, we report the quantum limit of detecting multi-mode light using heterodyne detection, and compare it to a typical down conversion source output.

Chapman, Joseph↗

Methodology for deriving the telescope focus function and its uncertainty for a heterodyne pulsed Doppler lidar

Doppler lidars provide two measured parameters, radial velocity and signal-to-noise ratio, from which winds and turbulent properties are routinely derived. Attenuated backscatter, which gives quantitative information on aerosols, clouds, and precipitation in the atmosphere, can be used in conjunction with the winds and turbulent properties to create a sophisticated classification of the state of the atmospheric boundary layer. Calculating attenuated backscatter from the signal-to-noise ratio requires accurate knowledge of the telescope focus function, which is usually unavailable. Inaccurate assumptions of the telescope focus function can significantly deform attenuated backscatter profiles, even if the instrument is focused at infinity. Here, we present a methodology for deriving the telescope focus function using a co-located ceilometer for pulsed heterodyne Doppler lidars. The method was tested with Halo Photonics StreamLine and StreamLine XR Doppler lidars but should also be applicable to other pulsed heterodyne Doppler lidar systems. The method derives two parameters of the telescope focus function, the effective beam diameter and the effective focal length of the telescope. Additionally, the method provides uncertainty estimates for the retrieved attenuated backscatter profile arising from uncertainties in deriving the telescope function, together with standard measurement uncertainties from the signal-to-noise ratio. The method is best suited for locations where the absolute difference in aerosol extinction at the ceilometer and Doppler lidar wavelengths is small.

54 ENVIRONMENTAL SCIENCES↗

Usefulness of the infrared heterodyne radiometer in remote sensing of atmospheric pollutants.

The application of narrow-band optical receivers to the problem of sensing atmospheric pollution is discussed. The emission/absorption lines of many major atmospheric pollutant molecules overlap the operating frequency bands of CO2 laser and CO laser heterodyne receivers. Several remote pollution sensing systems which are based upon utilization of these spectral overlaps are described, and an analysis of their potential is presented. The possibility of using other lasers (e.g.: the PbSnTe tunable diode laser) as local oscillators is also considered. Results of laboratory experiments with a CO2 laser heterodyne radiometer are presented.

Menzies, R. T.↗

N-type mercury-cadmium-telluride photoconductors in optical heterodyne communication systems.

Discussion of the performance of a photoconductive (Hg,Cd)Te detector/mixer in a carbon dioxide laser heterodyne communication system. The utility of computer simulation of the performance of an optical heterodyne detector/mixer is demonstrated. Certain unusual properties of this device are pointed out that, while having a substantial impact on device performance, have received little previous attention.

Cohen, S. C.↗

Infrared heterodyne solar radiometry.

An infrared heterodyne radiometer has sufficient sensitivity for application to high resolution spectrometric studies of the sun and the absorption of sunlight in the atmosphere. In the 10-micron region, the resolution can typically range from less than .0067/cm to .067/cm. The minimum detectable signal can approach 10 to the -24th power W/Hz. The infrared heterodyne radiometer (IHR) can also be used for atmospheric propagation studies at the emission frequencies of the CO2 laser for the examination of the feasibility of space-to-ground laser communication links.

Mcelroy, J. H.↗

High sensitivity infrared 10.6 micrometer heterodyne receiver development

The results are presented for a study on the design of an infrared 10.6-micrometer quantum-noise-limited optical receiver subsystem. Performance measurements of the HgCdTe photomixer preamplifier combination were carried out for photomixer temperatures up to 152 K and a photomixer frequency response of up to 420 MHz was obtained. Results of temperature and bias cycling of HgCdTe photomixers are reported. Design considerations for an operational 10.6 micrometer heterodyne receiver are presented. These consist of design data on required laser LO illumination, heat load levels for photomixer cooler, photomixer uniformity and the effects of photomixer impedance match on receiver sensitivity. Analysis and measurements of 10.6 micrometer heterodyne detection in an extrinsic photoconductive (p-type) HgCdTe photomixer are also presented.

Source record↗

Infrared heterodyne spectroscopy of astronomical and laboratory sources at 8.5 micron

The first infrared heterodyne spectrometer using tuneable semiconductor (PbSe) diode lasers has been constructed and was used near 8.5 micron to measure absorption line profiles of N2O in the laboratory and black body emission from the Moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz and the minimum detectable (black body) power was 1 x 10 to the minus 16th power watts for 8 minutes of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

Mumma, M.↗

Infrared heterodyne spectroscopy of CO2 on Mars

An infrared heterodyne spectrometer operating near 11 micrometers with a resolving power of 1,500,000 has been used to obtain spectral line profiles of carbon dioxide absorption in the Martian atmosphere. For a periodic calibration of the system sensitivity, a black body at 500 K was placed in front of the chopper. Atmospheric transmission was determined by measuring heterodyne signals from the moon and Mars as a function of the zenith angle.

Peterson, D. W.↗

Sensitivity limits of an infrared heterodyne spectrometer for astrophysical applications

A discussion and an evaluation of the degradation in sensitivity is given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness which results from the bandwidth being a function of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation in the sensitivity of a practical astronomical heterodyne spectrometer is approximately 30. Estimates of signal-to-noise ratios with which infrared line emission from astronomical sources of interest may be detected are given.

Abbas, M. M.↗

Heterodyne spectroscopy of astronomical and laboratory sources at 8.5 microns using diode laser local oscillators

The first 8.5 microns infrared heterodyne spectrometer has been constructed using tuneable semiconductor (PbSe) diode lasers and was used to measure absorption line profiles of N2O in the laboratory, as well as black-body emission from the moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz (6 millionths of a micron), and the minimum detectable (black-body) power was approximately 1 times 10 to the minus 16th power W for 8 min of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

Mumma, M.↗

Conclusions from the discussions on observational results of heterodyne spectroscopy in astronomy

Experimental results in astronomy obtained with the aid of infrared heterodyne detection techniques are considered, taking into account the detection of thermal emission with no dispersion at the intermediate frequency and observations involving molecular line detection. The tuning range of a heterodyne spectrometer and of a Fourier transform spectrometer is considered and attention is given to the selection of the appropriate technique for a specific investigative problem.-

Mumma, M.↗

Berkeley heterodyne interferometer

A prototype heterodyne stellar interferometer has been built in order to demonstrate the feasibility of heterodyne techniques in measuring angular diameters of bright infrared stars. The first system tests were performed in December 1972. Attention is given to investigations concerning the possibility that optical air turbulence within the structure of the solar telescope employed can possibly destroy the phase coherence of the fringe signals.

Betz, A.↗

Sensitivity limits of an infrared heterodyne spectrometer for astrophysical applications

A discussion and an evaluation of the degradation in sensitivity are given for a heterodyne spectrometer employing a HgCdTe photodiode mixer and tunable diode lasers. The minimum detectable source brightness is considered as a function of the mixer parameters, transmission coefficient of the beam splitter, and local oscillator emission powers. The degradation in the minimum detectable line source brightness that results from the bandwidth being a fraction of the line width is evaluated and plotted as a function of the wavelength and bandwidth for various temperature to mass ratios. It is shown that the minimum achievable degradation in the sensitivity of a practical astronomical heterodyne spectrometer is about 30. Estimates of SNRs with which IR line emission from astronomical sources of interest may be detected are given.

Abbas, M. M.↗

Atmospheric temperature profiling using an infrared heterodyne radiometer

The applicability of a high resolution infrared heterodyne radiometer for atmospheric temperature profiling is considered. Upwelling radiation at the 754.321/cm and the 945.976/cm rotational-vibrational lines of CO2 are monitored by a six IF channel infrared heterodyne radiometer with spectral specificity between 0.002 and 0.012/cm. Computer simulated retrievals have been carried out which indicate a maximum temperature inaccuracy of 3.5 K for vertical profiles between ground level and 50 km and a system integration time of 8 seconds.

Yustein, D.↗

Precision measurements of NH3 spectral lines near 11 microns using the infrared heterodyne technique

Absolute line-center frequencies for eleven lines of ammonia in near coincidence with CO2-laser transitions have been determined to accuracies of + or -3 MHz by infrared heterodyne detection. These results were obtained by heterodyning a blackbody with a stable grating-tuned CO2 gas laser. A discussion of the apparatus and method of calculation, including error analysis, is presented. With these accurately determined line-center positions, the ammonia molecule will be a useful secondary-frequency standard for diode-laser spectroscopy in the 11-micron wavelength region.

Hillman, J. J.↗

Stratospheric sounding by infrared heterodyne spectroscopy

Intensity profiles of infrared spectral lines of stratospheric constituents can be fully resolved with a heterodyne spectrometer of sufficiently high resolution. The constituents' vertical distributions can then be evaluated accurately by analytic inversion of the measured line profiles. Estimates of the detection sensitivity of a heterodyne receiver are given in terms of minimum detectable volume mixing ratios of stratospheric constituents, indicating a large number of minor constituents which can be studied. Stratospheric spectral line shapes, and the resolution required to measure them are discussed in light of calculated synthetic line profiles for some stratospheric molecules in a model atmosphere. The inversion technique for evaluation of gas concentration profiles is briefly described and applications to synthetic lines of O3, CO2, CH4 and N2O are given.

Abbas, M. M.↗

A 10 micron laser heterodyne spectrometer for remote detection of trace gases

Infrared heterodyne spectroscopy provides a means of measuring the intensity profiles of individual rotation-vibration spectral lines with high sensitivity. Considerable effort has been expended on optimizing these instruments for remote measurements of gases in planetary atmospheres with the result that present-generation spectrometers are beginning to provide new and startling results on the planets. The fundamental principles of laser heterodyne spectroscopy are discussed. Detailed considerations of the optical design and the electronic design of the spectral-line receiver are given. Representative results obtained with this spectrometer are discussed, including precision frequency measurements of NH3 (nu-2) lines, detection of auroral emission from Jupiter, and measurements of terrestrial O3 and CO2.

Mumma, M. J.↗

Infrared heterodyne spectroscopy for astronomical purposes

Heterodyne infrared astronomy was carried out using CO2 lasers and some solid state tunable lasers. The best available detectors are mercury cadmium telluride photodiodes. Their quantum efficiencies reach values near 0.5 and in an overall system an effective quantum efficiency, taking into account optical losses and amplifier noise, of about 0.25 was demonstrated. Initial uses of 10 micron heterodyne spectroscopy were for the study of planetary molecular spectra.

Townes, C. H.↗