Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

How Effective Are Clinical Pathways With and Without Online Peer-Review? An Analysis of Bone Metastases Pathway in a Large, Integrated National Cancer Institute-Designated Comprehensive Cancer Center Network

Purpose: Clinical pathways are an important tool used to manage the quality in health care by standardizing processes. This study evaluated the impact of the implementation of a peer-reviewed clinical pathway in a large, integrated National Cancer Institute-Designated Comprehensive Cancer Center Network. Methods: In 2003, we implemented a clinical pathway for the management of bone metastases with palliative radiation therapy. In 2009, we required the entry of management decisions into an online tool that records pathway choices. The pathway specified 1 or 5 fractions for symptomatic bone metastases with the option of 10-14 fractions for certain clinical situations. The data were obtained from 13 integrated sites (3 central academic, 10 community locations) from 2003 through 2010. Results: In this study, 7905 sites were treated with 64% of courses delivered in community practice and 36% in academic locations. Academic practices were more likely than community practices to treat with 1-5 fractions (63% vs. 23%; p < 0.0001). The number of delivered fractions decreased gradually from 2003 to 2010 for both academic and community practices (p < 0.0001); however, greater numbers of fractions were selected more often in community practices (p < 0.0001). Using multivariate logistic regression, we found that a significantly greater selection of 1-5 fractions developed after implementation online pathway monitoring (2009) with an odds ratio of 1.2 (confidence interval, 1.1-1.4) for community and 1.3 (confidence interval, 1.1-1.6) for academic practices. The mean number of fractions also decreased after online peer review from 6.3 to 6.0 for academic (p = 0.07) and 9.4 to 9.0 for community practices (p < 0.0001). Conclusion: This is one of the first studies to examine the efficacy of a clinical pathway for radiation oncology in an integrated cancer network. Clinical pathway implementation appears to be effective in changing patterns of care, particularly with online clinical peer review as a valuable aid to encourage adherence to evidence-based practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preoperative Intensity Modulated Radiation Therapy and Chemotherapy for Locally Advanced Vulvar Carcinoma: Analysis of Pattern of Relapse

Purpose: To examine clinical outcomes and relapse patterns in locally advanced vulvar carcinoma treated using preoperative chemotherapy and intensity modulated radiation therapy (IMRT). Methods and Materials: Forty-two patients with stage I-IV{sub A} (stage I, n=3; stage II, n=13; stage III, n=23; stage IV{sub A}, n=3) vulvar cancer were treated with chemotherapy and IMRT via a modified Gynecological Oncology Group schema using 5-fluorouracil and cisplatin with twice-daily IMRT during the first and last weeks of treatment or weekly cisplatin with daily radiation therapy. Median dose of radiation was 46.4 Gy. Results: Thirty-three patients (78.6%) had surgery for resection of vulva; 13 of these patients also had inguinal lymph node dissection. Complete pathologic response was seen in 48.5% (n=16) of these patients. Of these, 15 had no recurrence at a median time of 26.5 months. Of the 17 patients with partial pathological response, 8 (47.1%) developed recurrence in the vulvar surgical site within a median of 8 (range, 5-34) months. No patient had grade ≥3 chronic gastrointestinal/genitourinary toxicity. Of those having surgery, 8 (24.2%) developed wound infections requiring debridement. Conclusions: Preoperative chemotherapy/IMRT was well tolerated, with good pathologic response and clinical outcome. The most common pattern of recurrence was local in patients with partial response, and strategies to increase pathologic response rate with increasing dose or adding different chemotherapy need to be explored to help further improve outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extended (5-year) Outcomes of Accelerated Partial Breast Irradiation Using MammoSite Balloon Brachytherapy: Patterns of Failure, Patient Selection, and Dosimetric Correlates for Late Toxicity

Purpose: Accelerated partial breast irradiation (APBI) with balloon and catheter-based brachytherapy has gained increasing popularity in recent years and is the subject of ongoing phase III trials. Initial data suggest promising local control and cosmetic results in appropriately selected patients. Long-term data continue to evolve but are limited outside of the context of the American Society of Breast Surgeons Registry Trial. Methods and Materials: A retrospective review of 157 patients completing APBI after breast-conserving surgery and axillary staging via high-dose-rate {sup 192}Ir brachytherapy from June 2002 to December 2007 was made. APBI was delivered with a single-lumen MammoSite balloon-based applicator to a median dose of 34 Gy in 10 fractions over a 5-day period. Tumor coverage and critical organ dosimetry were retrospectively collected on the basis of computed tomography completed for conformance and symmetry. Results: At a median follow-up time of 5.5 years (range, 0-10.0 years), the 5-year and 7-year actuarial incidences of ipsilateral breast control were 98%/98%, of nodal control 99%/98%, and of distant control 99%/99%, respectively. The crude rate of ipsilateral breast recurrence was 2.5% (n=4); of nodal failure, 1.9% (n=3); and of distant failure, 0.6% (n=1). The 5-year and 7-year actuarial overall survival rates were 89%/86%, with breast cancer–specific survival of 100%/99%, respectively. Good to excellent cosmetic outcomes were achieved in 93.4% of patients. Telangiectasia developed in 27% of patients, with 1-year, 3-year, and 5-year actuarial incidence of 7%/24%/33%; skin dose >100% significantly predicted for the development of telangiectasia (50% vs 14%, P<.0001). Conclusions: Long-term single-institution outcomes suggest excellent tumor control, breast cosmesis, and minimal late toxicity. Skin toxicity is a function of skin dose, which may be ameliorated with dosimetric optimization afforded by newer multicatheter brachytherapy applicators and a more rigorous skin dose constraint of ≤100%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

4π Noncoplanar Stereotactic Body Radiation Therapy for Head-and-Neck Cancer: Potential to Improve Tumor Control and Late Toxicity

Purpose: To evaluate the potential benefit of 4π radiation therapy in recurrent, locally advanced, or metastatic head-and-neck cancer treated with stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty-seven patients with 29 tumors who were treated using SBRT were included. In recurrent disease (n=26), SBRT was delivered with a median 44 Gy (range, 35-44 Gy) in 5 fractions. Three patients with sinonasal mucosal melanoma, metastatic breast cancer, and primary undifferentiated carcinoma received 35 Gy, 22.5 Gy, and 40 Gy in 5 fractions, respectively. Novel 4π treatment plans were created for each patient to meet the objective that 95% of the planning target volume was covered by 100% of the prescription dose. Doses to organs at risk (OARs) and 50% dose spillage volumes were compared against the delivered clinical SBRT plans. Local control (LC), late toxicity, tumor control probability (TCP), and normal tissue complication probability were determined. Results: Using 4π plans, mean/maximum doses to all OARs were reduced by 22% to 89%/10% to 86%. With 4π plans, the 50% dose spillage volume was decreased by 33%. Planning target volume prescription dose escalation by 10 Gy and 20 Gy were achieved while keeping doses to OARs significantly improved or unchanged from clinical plans, except for the carotid artery maximum dose at 20-Gy escalation. At a median follow-up of 10 months (range, 1-41 months), crude LC was 52%. The 2-year LC of 39.2% approximated the predicted mean TCP of 42.2%, which increased to 45.9% with 4π plans. For 10-Gy and 20-Gy dose escalation, 4π plans increased TCP from 80.1% and 88.1% to 85.5% and 91.4%, respectively. The 7.4% rate of grade ≥3 late toxicity was comparable to the predicted 5.6% mean normal tissue complication probability for OARs, which was significantly reduced by 4π planning at the prescribed and escalated doses. Conclusions: 4π plans may allow dose escalation with significant and consistent improvements in critical organ sparing, tumor control, and coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Pathways: A Catalyst for the Adoption of Hypofractionation for Early-Stage Breast Cancer

Purpose: Hypofractionated whole-breast irradiation (HF-WBI) remains underutilized in the United States despite support by multiple clinical trials. We evaluated the success of iterative modifications of our breast cancer clinical pathway on the adoption of HF-WBI in a large, integrated radiation oncology network. Methods and Materials: The breast clinical pathway was modified in January 2011 (Amendment 1) to recommend HF-WBI as the first option for women ≥70 of age with stages 0 to IIA, while maintaining conventional fractionation (CF) as a pathway-concordant secondary option. In January 2013 (Amendment 2), the pathway's HF-WBI recommendation was extended to women ≥50 years of age. In January 2014 (Amendment 3), the pathway mandated HF-WBI as the only pathway-concordant option in women ≥50 years of age, and all pathway-discordant plans were subject to peer review and justification. Women ≥50 years of age with ductal carcinoma in situ or invasive breast cancer who underwent breast conserving surgery and adjuvant WBI were included in this analysis. Results: We identified 5112 patients from 2009 to 2014 who met inclusion criteria. From 2009 to 2012, the overall HF-WBI use rate was 8.3%. Following Amendments 2 and 3 (2013 and 2014, respectively), HF-WBI use significantly increased to 21.8% (17.3% in the community, 39.7% at academic sites) and 76.7% (75.5% in the community, 81.4% at academic sites), respectively (P<.001). Compared to 2009 to 2012, the relative risk of using HF-WBI was 7.9 (95% confidence interval: 7.1-8.6, P<.001) and 10.7 (95% CI: 10.3-11.0, P<.001), respectively, after Amendments 2 and 3, respectively. Age ≥70 and treatment at an academic site increased the likelihood of receiving HF-WBI in 2009 to 2012 and following Amendment 2 (P<.001). Conclusions: This study demonstrates the transformative effect of a clinical pathway on patterns of care for breast radiation therapy. Although our initial HF-WBI use rate was low (8%-22%) and consistent with national rates, the clinical pathway approach dramatically increased adoption rate to >75%. In contrast to passive guidelines, clinical pathways serve as active tools to promote current best practices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermodynamic origin of nonvolatility in resistive memory

Electronic switches based on the migration of high-density point defects, or memristors, are poised to revolutionize post-digital electronics. Despite significant research, key mechanisms for filament formation and oxygen transport remain unresolved, hindering our ability to predict and design device properties. For example, experiments have achieved 10 orders of magnitude longer retention times than predicted by current models. Here, using electrical measurements, scanning probe microscopy, and first-principles calculations on tantalum oxide memristors, we reveal that the formation and stability of conductive filaments crucially depend on the thermodynamic stability of the amorphous oxygen-rich and oxygen-poor compounds, which undergo composition phase separation. Including the previously neglected effects of this amorphous phase separation reconciles unexplained discrepancies in retention and enables predictive design of key performance indicators such as retention stability. Furthermore, this result emphasizes non-ideal thermodynamic interactions as key design criteria in post-digital devices with defect densities substantially exceeding those of today’s covalent semiconductors.

36 MATERIALS SCIENCE↗

Synchrony - Cyberknife Respiratory Compensation Technology

Studies of organs in the thorax and abdomen have shown that these organs can move as much as 40 mm due to respiratory motion. Without compensation for this motion during the course of external beam radiation therapy, the dose coverage to target may be compromised. On the other hand, if compensation of this motion is by expansion of the margin around the target, a significant volume of normal tissue may be unnecessarily irradiated. In hypofractionated regimens, the issue of respiratory compensation becomes an important factor and is critical in single-fraction extracranial radiosurgery applications. CyberKnife is an image-guided radiosurgery system that consists of a 6-MV LINAC mounted to a robotic arm coupled through a control loop to a digital diagnostic x-ray imaging system. The robotic arm can point the beam anywhere in space with 6 degrees of freedom, without being constrained to a conventional isocenter. The CyberKnife has been recently upgraded with a real-time respiratory tracking and compensation system called Synchrony. Using external markers in conjunction with diagnostic x-ray images, Synchrony helps guide the robotic arm to move the radiation beam in real time such that the beam always remains aligned with the target. With the aid of Synchrony, the tumor motion can be tracked in three-dimensional space, and the motion-induced dosimetric change to target can be minimized with a limited margin. The working principles, advantages, limitations, and our clinical experience with this new technology will be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric influences of rotational setup errors on head and neck carcinoma intensity-modulated radiation therapy treatments

The purpose of this work is to investigate the dosimetric influence of the residual rotational setup errors on head and neck carcinoma (HNC) intensity-modulated radiation therapy (IMRT) with routine 3 translational setup corrections and the adequacy of this routine correction. A total of 66 kV cone beam computed tomography (CBCT) image sets were acquired on the first day of treatment and weekly thereafter for 10 patients with HNC and were registered with the corresponding planning CT images, using 2 3-dimensional (3D) rigid registration methods. Method 1 determines the translational setup errors only, and method 2 determines 6-degree (6D) setup errors, i.e., both rotational and translational setup errors. The 6D setup errors determined by method 2 were simulated in the treatment planning system and were then corrected using the corresponding translational data determined by method 1. For each patient, dose distributions for 6 to 7 fractions with various setup uncertainties were generated, and a plan sum was created to determine the total dose distribution through an entire course and was compared with the original treatment plan. The average rotational setup errors were 0.7°± 1.0°, 0.1°±1.9°, and 0.3°±0.7° around left-right (LR), anterior-posterior (AP), and superior-inferior (SI) axes, respectively. With translational corrections determined by method 1 alone, the dose deviation could be large from fraction to fraction. For a certain fraction, the decrease in prescription dose coverage (V{sub p}) and the dose that covers 95% of target volume (D{sub 95}) could be up to 15.8% and 13.2% for planning target volume (PTV), and the decrease in V{sub p} and the dose that covers 98% of target volume (D{sub 98}) could be up to 9.8% and 5.5% for the clinical target volume (CTV). However, for the entire treatment course, for PTV, the plan sum showed that the average V{sub p} was decreased by 4.2% and D{sub 95} was decreased by 1.2 Gy for the first phase of IMRT with a prescription dose of 50 Gy. For CTV, the plan sum showed that the average V{sub p} was decreased by 0.8% and D{sub 98}, relative to prescription dose, was not decreased. Among these 10 patients, the plan sum showed that the dose to 1-cm{sup 3} spinal cord (D{sub 1cm{sup 3}}) increased no more than 1 Gy for 7 patients and more than 2 Gy for 2 patients. The average increase in D{sub 1cm{sup 3}} was 1.2 Gy. The study shows that, with translational setup error correction, the overall CTV V{sub p} has a minor decrease with a 5-mm margin from CTV to PTV. For the spinal cord, a noticeable dose increase was observed for some patients. So to decide whether the routine clinical translational setup error correction is adequate for this HNC IMRT technique, the dosimetric influence of rotational setup errors should be evaluated carefully from case to case when organs at risk are in close proximity to the target.

61 RADIATION PROTECTION AND DOSIMETRY↗

Is high–dose rate RapidArc-based radiosurgery dosimetrically advantageous for the treatment of intracranial tumors?

In linac-based stereotactic radiosurgery (SRS) and radiotherapy (SRT), circular cone(s) or conformal arc(s) are conventionally used to treat intracranial lesions. However, when the target is in close proximity to critical structures, it is frequently quite challenging to generate a quality plan using these techniques. In this study, we investigated the dosimetric characteristics of using high–dose rate RapidArc (RA) technique for radiosurgical treatment of intracranial lesions. A total of 10 intracranial SRS/SRT cases previously planned using dynamic conformal arc (DCA) or cone-based techniques have been included in this study. For each case, 3 treatment plans were generated: (1) a DCA plan with multiple noncoplanar arcs, (2) a high–dose rate RA plan with arcs oriented the same as DCA (multiple-arc RA), and 3) a high–dose rate RA plan with a single coplanar arc (single-arc RA). All treatment plans were generated under the same prescription and similar critical structure dose limits. Plan quality for different plans was evaluated by comparing various dosimetric parameters such as target coverage, conformity index (CI), homogeneity index (HI), critical structures, and normal brain tissue doses as well as beam delivery time. With similar critical structure sparing, high–dose rate RA plans can achieve much better target coverage, dose conformity, and dose homogeneity than the DCA plans can. Plan quality indices CI and HI, for the DCA, multiple-arc RA, and single-arc RA techniques, were measured as 1.67 ± 0.39, 1.32 ± 0.28, and 1.38 ± 0.30 and 1.24 ± 0.11, 1.10 ± 0.04, and 1.12 ± 0.07, respectively. Normal brain tissue dose (V{sub 12} {sub Gy}) was found to be similar for DCA and multiple-arc RA plans but much larger for the single-arc RA plans. Beam delivery was similar for DCA and multiple-arc RA plans but shorter with single-arc RA plans. Multiple-arc RA SRS/SRT can provide better treatment plans than conventional DCA plans, especially for complex cases.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large resistivity modulation in mixed-phase metallic systems

Giant physical responses were discovered, in numerous systems, when two phases coexist; for example, near a phase transition. An intermetallic FeRh system undergoes a first-order antiferromagnetic to ferromagnetic transition above room temperature and shows two-phase coexistence near the transition. We have investigated the effect of an electric field to FeRh/PMN-PT heterostructures and report 8% change in the electrical resistivity of FeRh films. Such a 'giant' electroresistance (GER) response is striking in metallic systems, in which external electric fields are screened, and thus only weakly influence the carrier concentrations and mobilities. We show that our FeRh films comprise coexisting ferromagnetic and antiferromagnetic phases with different resistivities and the origin of the GER effect is the strain-mediated change in their relative proportions. Finally, the observed behaviour is reminiscent of colossal magnetoresistance in perovskite manganites and illustrates the role of mixed-phase coexistence in achieving large changes in physical properties with low-energy external perturbation.

36 MATERIALS SCIENCE↗

A large-scale evaluation of computational protein function prediction

Automated annotation of protein function is challenging. As the number of sequenced genomes rapidly grows, the overwhelming majority of protein products can only be annotated computationally. If computational predictions are to be relied upon, it is crucial that the accuracy of these methods be high. Here we report the results from the first large-scale community-based critical assessment of protein function annotation (CAFA) experiment. Fifty-four methods representing the state of the art for protein function prediction were evaluated on a target set of 866 proteins from 11 organisms. Two findings stand out: (i) today’s best protein function prediction algorithms substantially outperform widely used first-generation methods, with large gains on all types of targets; and (ii) although the top methods perform well enough to guide experiments, there is considerable need for improvement of currently available tools.

59 BASIC BIOLOGICAL SCIENCES↗

Engineering new limits to magnetostriction through metastability in iron-gallium alloys

Magnetostrictive materials transduce magnetic and mechanical energies and when combined with piezoelectric elements, evoke magnetoelectric transduction for high-sensitivity magnetic field sensors and energy-efficient beyond-CMOS technologies. The dearth of ductile, rare-earth-free materials with high magnetostrictive coefficients motivates the discovery of superior materials. Fe 1- x Ga x alloys are amongst the highest performing rare-earth-free magnetostrictive materials; however, magnetostriction becomes sharply suppressed beyond x = 19% due to the formation of a parasitic ordered intermetallic phase. Here, we harness epitaxy to extend the stability of the BCC Fe 1- x Ga x alloy to gallium compositions as high as x = 30% and in so doing dramatically boost the magnetostriction by as much as 10x relative to the bulk and 2x larger than canonical rare-earth based magnetostrictors. A Fe 1- x Ga x - [Pb(Mg 1/3 Nb 2/3 )O 3 ] 0.7 -[PbTiO 3 ] 0.3 (PMN-PT) composite magnetoelectric shows robust 90° electrical switching of magnetic anisotropy and a converse magnetoelectric coefficient of 2.0 × 10 -5 s m -1 . When optimally scaled, this high coefficient implies stable switching at ~80 aJ per bit.

36 MATERIALS SCIENCE↗

Endotaxial stabilization of 2D charge density waves with long-range order

Charge density waves are emergent quantum states that spontaneously reduce crystal symmetry, drive metal-insulator transitions, and precede superconductivity. In low-dimensions, distinct quantum states arise, however, thermal fluctuations and external disorder destroy long-range order. Here we stabilize ordered two-dimensional (2D) charge density waves through endotaxial synthesis of confined monolayers of 1T-TaS 2 . Specifically, an ordered incommensurate charge density wave (oIC-CDW) is realized in 2D with dramatically enhanced amplitude and resistivity. By enhancing CDW order, the hexatic nature of charge density waves becomes observable. Upon heating via in-situ TEM, the CDW continuously melts in a reversible hexatic process wherein topological defects form in the charge density wave. From these results, new regimes of the CDW phase diagram for 1T-TaS 2 are derived and consistent with the predicted emergence of vestigial quantum order.

36 MATERIALS SCIENCE↗

Effects of local compositional and structural disorder on vacancy formation in entropy-stabilized oxides from first-principles

Entropic stabilization has evolved into a strategy to create new oxide materials and realize novel functional properties engineered through the alloy composition. Achieving an atomistic understanding of these properties to enable their design, however, has been challenging due to the local compositional and structural disorder that underlies their fundamental structure-property relationships. Here, we combine high-throughput atomistic calculations and linear regression algorithms to investigate the role of local configurational and structural disorder on the thermodynamics of vacancy formation in (MgCoNiCuZn)O-based entropy-stabilized oxides (ESOs) and their influence on the electrical properties. We find that the cation-vacancy formation energies decrease with increasing local tensile strain caused by the deviation of the bond lengths in ESOs from the equilibrium bond length in the binary oxides. The oxygen-vacancy formation strongly depends on structural distortions associated with the local configuration of chemical species. Vacancies in ESOs exhibit deep thermodynamic transition levels that inhibit electrical conduction. By applying the charge-neutrality condition, we determine that the equilibrium concentrations of both oxygen and cation vacancies increase with increasing Cu mole fraction. Our results demonstrate that tuning the local chemistry and associated structural distortions by varying alloy composition acts an engineering principle that enables controlled defect formation in multi-component alloys.

36 MATERIALS SCIENCE↗

Superconductivity in a quintuple-layer square-planar nickelate

Since the discovery of high-temperature superconductivity in the copper oxide materials, there have been sustained efforts to both understand the origins of this phase and discover new cuprate-like superconducting materials. One prime materials platform has been the rare-earth nickelates and indeed superconductivity was recently discovered in the doped compound Nd 0.8 Sr 0.2 NiO 2 . Undoped NdNiO 2 belongs to a series of layered square-planar nickelates with chemical formula Nd n+1 Ni n O 2n+2 and is known as the 'infinite-layer' (n=∞) nickelate. Furthermore, we report the synthesis of the quintuple-layer (n=5) member of this series, Nd 6 Ni 5 O 12 , in which optimal cuprate-like electron filling (d 8.8 ) is achieved without chemical doping. We observe a superconducting transition beginning at ~13 K. Electronic structure calculations, in tandem with magnetoresistive and spectroscopic measurements, suggest that Nd 6 Ni 5 O 12 interpolates between cuprate-like and infinite-layer nickelate-like behavior. In engineering a distinct superconducting nickelate, we identify the square-planar nickelates as a new family of superconductors which can be tuned via both doping and dimensionality.

36 MATERIALS SCIENCE↗