Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “grid operators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Preventive Power Outage Estimation Based on a Novel Scenario Clustering Strategy

The increasing occurrence of extreme weather events is challenging power grid operation. For extreme weather events, the system operator is responsible for estimating the power outages and scheduling the restoration resources. This paper proposes an outage evaluation framework to identify the possible unserved load profiles, vulnerable areas, and mobile energy adequacy. The outputs of an outage prediction model tool are used to generate numerous faulted line scenarios. Next, each scenario's nodal unserved load profile is obtained by solving a three-phase restoration model that considers repair crews and mobile energy resources (MERs). Then, a novel scenario clustering strategy is developed to cluster the unserved load profiles into multiple representative profiles which the system operator can focus on. Finally, case studies on a distribution system evaluate the damage caused by an extreme weather event and verify the effectiveness of the proposed scenario clustering strategy.

MATHEMATICS AND COMPUTING,POWER TRANSMISSION AND D↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Power Grid Reliability Estimation via Adaptive Importance Sampling

Electricity production currently generates approximately 25% of greenhouse gas emissions in the USA. Thus, increasing the amount of renewable energy is a key step to carbon neutrality. However, integrating a large amount of fluctuating renewable generation is a significant challenge for power grid operating and planning. Grid reliability, i.e., an ability to meet operational constraints under power fluctuations, is probably the most important of them. In this letter, we propose computationally efficient and accurate methods to estimate the probability of line overflow, i.e., reliability constraints violation, under a known distribution of renewable energy generation. To this end, we investigate an importance sampling approach, a flexible extension of Monte-Carlo methods, which adaptively changes the sampling distribution to generate more samples near the reliability boundary. The approach allows to estimate overload probability in real-time based only on a few dozens of random samples, compared to thousands required by the plain Monte-Carlo. Our study focuses on high voltage direct current power transmission grids with linear reliability constraints on power injections and line currents. Herein, we propose a novel theoretically justified physics-informed adaptive importance sampling algorithm and compare its performance to state-of-the-art methods on multiple IEEE power grid test cases.

power system faults↗

EVs-at-RISC: A Secure and Resilient Interoperable SCM Control System Architecture for Electric Vehicle’s-at-Scale (Final Technical Report)

The EVs-at-RISC project was a five-year research, development, and demonstration initiative to create foundational tools for utility-scale fleet aggregation and Smart Charge Management (SCM) of Electric Vehicles (EV), Electric Vehicle Charging Infrastructure (EVCI), and related Distributed Energy Resources (DER). Rather than seeking to develop and demonstrate highly perfected SCM algorithms and control strategies, this project instead focused on creating foundational software solutions that enable unprecedented digital interoperability across the communications technologies and vendor platforms used to manage EV , EVCI, and DER, as well as existing energy management infrastructure operated by utilities, grid operators, and aggregators. This project then extends these novel interoperability capabilities to develop and deploy powerful middleware abstractions across grid edge networks and EVCI/DER fleet aggregations incorporating modern software tools and best practices, such as CI/CD, to bring the immense capabilities of infrastructure-as-code and policy-as-code to modern grid edge network environments. This addresses the foremost systemic issues preventing realization of any net operational benefits from scaled deployment of behind-the-meter EV, EVCI, and DER assets in electric power grids and markets today. The results of this approach and project unlock massive potential for new SCM capabilities to be easily prototyped, evaluated, and deployed at-scale within the existing grid edge network infrastructure and EVCI/DER technology ecosystem. The EVs-at-RISC project achieves this by extending Open Field Message Bus (OpenFMB), a conceptual model for digital interoperability and distributed intelligence in traditional front-of-meter utility SCADA networks, validating our hypothesis that OpenFMB could be similarly used to solve systemic digital interoperability issues in behind-the-meter environments and unlock real-world utility-scale SCM capabilities without requiring any new proprietary vendor solutions or significant infrastructure reconfiguration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Standards for Photovoltaic Operations

Solar energy plays an important role in securing a more resilient, cyber-secure electrical grid in Pennsylvania. Solar's ability to be widely "distributed" on residential and large roofs, marginal lands, and many other locations across Pennsylvania - as opposed to being centralized - offers a strong option for addressing the myriad of potential disruptions that can occur to the grid's infrastructure. And when combined with energy storage, local energy needs can be met immediately without having to wait on the delivery of an off-site fuel source. As more and more distributed solar electricity generation is brought online, researchers, technology developers, solar developers and grid operators are paying close attention to the potential for solar to enhance grid cybersecurity. Although nobody may know when, where, or how the next cyberattack will take place, there are security measures, technical solutions, and management practices that are being implemented across the industry to protect against network control issues and grid operations. Everyone participating in the solar value chain stands to gain from a coordinated, iterative approach to protect against cyber vulnerabilities and build deeper resilience into the architecture of our grid.

cybersecurity↗

Modified Virtual Oscillator Based Operation of Grid Forming Converters with Single Voltage Sensor

Virtual oscillator based control architecture for grid forming converter with inner current control loop for additional objective accomplishments is proposed in this paper. In general, virtual oscillator is based on Lienard type of oscillator equation with a cubic nonlinearity. Virtual oscillator alone cannot accommodate unbalanced or harmonic mitigation while operating converters in grid forming mode. Therefore, to accomplish better tracking performance, incorporating the provision for nonlinear and/or unbalanced loads, an inner current control loop is utilized which is based upon Lyapunov energy function type control architecture due to its advantages. To reduce the overall cost of implementation and ensure proper phase difference in the generated voltages, the implemented virtual oscillator operates with only one voltage feedback from the point of common coupling as presented in this paper. To verify the effectiveness of the proposed approach, the overall system has been modeled in MATTLAB/Simulink and PLECS domain and case studies showing the successful production of low harmonic load voltages under nonideal loading condition along with other important results are presented in this paper.

dual second order generalized integrator↗

A Trilevel Model for Segmentation of the Power Transmission Grid Cyber Network

Network segmentation of a power grid's communication system can make the grid more resilient to cyberattacks. Here we develop a novel trilevel programming model to optimally segment a grid communication system, taking into account the actions of an information technology (IT) administrator, attacker, and grid operator. The IT administrator is allowed to segment existing networks, and the attacker is given a budget to inflict damage on the grid by attacking the segmented communication system. Finally, the grid operator can redispatch the grid after the attack to minimize damage. The resulting problem is a trilevel interdiction problem that we solve using a branch and bound algorithm for bilevel problems. We demonstrate the benefits of optimal network segmentation through case studies on the 9-bus Western System Coordinating Council (WSCC) system and the 30-bus IEEE system. These examples illustrate that network segmentation can significantly reduce the threat posed by a cyberattacker.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transactive energy systems for distributed blackstart and service recovery

Abstract Current transactive controls use marginal benefits and marginal costs to achieve an economic market efficiency during normal grid operations. However, the transactive mechanisms designed for normal economic operations cannot be applied directly for the contingencies because the grid operations during contingencies are often dictated by technical needs rather than purely economic criteria. For instance, one of the key technical requirements for the blackstart is to have at least one blackstart capable resource cleared which cannot be ensured by the transactive mechanism designed for normal economic operations because they work primarily based on the marginal benefit and marginal cost of the participants. This article presents one of the first attempts to develop a transactive mechanism to be used during grid contingencies. A distributed blackstart and service recovery is used as an example contingency to evaluate the performance of the proposed transactive mechanism. The performance of the proposed transactive mechanism is demonstrated for various use cases using a modified IEEE‐123 node test system. The simulation results demonstrated the proof of concept of applying a transactive mechanism to enable distributed blackstart and service recovery by engaging the mix of blackstart capable and non‐capable distributed energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization Framework for Solar Energy Integrated Resilient Distribution Grid

The increasing penetration of distributed photovoltaic (PV) energy and other distributed energy resources (DERs) such as energy storage batteries, diesel generators, and mobile generators deployed in distribution grids must be properly controlled and coordinated to ensure reliable, resilient, and affordable grid operation in response to various operating conditions. Particularly, weather-induced power outages, such as natural disasters, are among the most common causes of power supply interruptions for distribution grid operations [E-1]. Distributed PV and DERs feature advanced grid supporting capabilities and can potentially enhance power supply continuity during and after extreme weather events. To leverage PV and other DERs to provide resilience benefits while ensuring operational and economic feasibility, distribution grids must be carefully designed, proactively managed, and safely operated through a comprehensive framework.

14 SOLAR ENERGY↗

Optimal Electric Vehicle Charging and Discharging Strategies Under DER Compensation Programs: Preprint

The adoption of electric vehicles (EVs) is becoming increasingly popular because of environmental concerns, the greater availability of models, and increased cost-competitiveness with gas vehicles. Because EVs have both charging and discharging capabilities, they provide great potential to help electric utilities with grid operation. When the grid demand is high, EVs can discharge to the grid to reduce the peak load, and vice versa; therefore, electric utilities have designed different policies to encourage EV charging station operators to charge or discharge at certain time periods. The New York State Public Service Commission established the Value of Distributed Energy Resources (VDER), or the Value Stack, to compensate for energy created by distributed energy resources, including EVs. This paper presents an optimization-based approach to identify the "golden hours" and "golden spots," i.e., the effective time periods and geographic locations for EV charging station operators to charge or discharge under the VDER program that can provide them the highest benefit. The proposed methodology can be applied to other compensation mechanisms and distribution systems as well. By working with industry partner NineDot Energy, realistic charging station information is used in this study, and the proposed approach is tested on a distribution feeder. The results from this study can help electric utilities and EV charging station operators determine the ideal charging/discharging time and the ideal locations for the charging station(s) in their distribution systems to achieve maximized benefit.

electric vehicle↗

Efficiency and Demand Flexibility in Large Office Buildings: The Potential for Cost Savings and CO 2 Reductions from Lighting and Cooling Measures

This report presents the estimated impact of lighting and cooling efficiency and demand flexibility measures in large office buildings in each state in the contiguous United States. It provides modeled results for three different metrics: bill savings, regional grid operational costs savings, and carbon dioxide (CO 2 ) emissions reductions. Lighting efficiency and demand flexibility are estimated to reduce load by up to 80 MWh/yr in a single large office building. These load reductions result in customer bill savings of up to $8,800/yr per building, with the highest savings in southern and midwestern states. Grid operating cost savings are estimated at up to $3,240/yr/building, with greatest benefit in southern and northeastern states. CO 2 emissions reduction potential is highest in the Dakotas, Nebraska, across the Midwest, in West Virginia, and in Mississippi (<48,200 kg/yr/building). Comparatively, cooling measures are found to have less load reduction potential (<28.5 MWh/yr/building), with the greatest potential in southern states including Texas, which ranks top of the list across several of the metrics studied. In numerous states, shifting cooling load to off-peak hours is found to increase costs and CO 2 emissions because precooling results in increased load during high-cost or high-CO 2 emissions periods. In general, focusing on cooling efficiency and load shedding has the potential for more savings. In all cases, the specific rate structure is a significant determinant in actual bill savings, which are up to $4,000/yr/building. To realize the full potential for bill savings through an energy measure, building operators must identify how the measure will change the building load pattern and the interaction of this load change with the applicable rate tariff. To realize CO 2 emissions reductions, industry and state coordination is needed to verify which fuel source is on the margin and then to create incentives for end users to reduce load during high-CO 2 emissions hours. Regular updates to data sets and analyses are critical. Regulators and policymakers are well positioned to facilitate the necessary coordination between the electric industry and building energy managers to develop appropriate price signals and incentives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

27 ARPA - Advanced Research Projects Agency-Energy↗

A Comprehensive Strategy for Grid Forming Control in DC Coupled Photovoltaic and Battery Energy Storage Inverters

This paper presents an integrated DC-DC and DCAC grid-forming control strategy for DC-coupled photovoltaic (PV) plus battery energy storage systems, considering the effect of DC link voltage variations caused by direct PV connections. A power reference algorithm determines power distribution between the PV and battery to the grid while observing device power ratings to prevent the over-rating of components and keep the battery's state of charge within an acceptable range. The simulated utility-scale model in MATLAB/Simulink illustrates its ability against extreme phase angle variation contingencies in the grid while controlled through grid-forming control with a fast dynamic on DC link voltage. The simulation results confirm the effectiveness of the proposed control in integrating PV plus battery configurations with grid forming control and maintaining reliable grid operation under severe grid disturbances.

battery, boost, control, energy storage, grid form↗

Data-Enhanced Hierarchical Control to Improve Distribution Voltage with Extremely High PV Penetration

Dynamic, scalable, and interoperable control paradigms are required to enable efficient, secure, reliable, and resilient distribution grid operations with widespread grid integration of renewable energy resources. This paper presents our recent research on developing a novel, holistic, data-enhanced hierarchical control architecture that addresses the formidable challenges faced by emerging distribution grids with increasing penetrations of distributed energy resources. The proposed architecture integrates centralized monitoring and control with distributed grid-edge control and thus effectively deals with multi-spatiotemporal dynamics existing in the grid. Simulation results are provided to demonstrate the effectiveness of the proposed control architecture.

14 SOLAR ENERGY↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Visualization of Multi-Fidelity Approximations of Stochastic Economic Dispatch

As renewable energy generation deployment increases, the operation of electrical grids becomes more complex. Economic dispatch is part of a grid operator's regular decision process where the amount of energy to generate is determined based on the number of available generators and the actual level of energy demand. Renewable generators are inherently stochastic due to the chaotic nature of weather patterns, and thus, real-time decisions of economic dispatch become increasingly complex. Modeling efforts to assist in these decisions in the highest fidelity typically take hours to days to solve on leadership-class computers; too long for the 5-minute operational time-frame demanded of operators. Alternatively, multi-fidelity approximations can be used to predict generation levels quickly and with sufficient accuracy to be used for real-time operations. We have developed a visualization tool to demonstrate the utility of multi-fidelity approximations by displaying contextual results of economic dispatch approximations, comparisons across fidelity levels of generation levels and possible failures to meet demand, and meta-data on the modeling setup.

interactive visualization↗

Water Resource Opportunities at Lake Gazivode/Ujmani

The U.S. Department of Energy’s (DOE’s) Pacific Northwest National Laboratory (PNNL) has been tasked by DOE’s Office of International Affairs to assess the use of water resources for power generation needs on Lake Gazivode/Ujmani in Kosovo, and provide recommendations for improved coordination and efficiency. Lake Gazivode/Ujmani is a 15-mile long man-made reservoir that straddles the Serbian-Kosovo border. Lake Gazivode/Ujmani is currently managed without a transboundary cooperation agreement. Kosovo is profoundly dependent on the lake’s waters, which provide one-third of Kosovo’s drinking water and cool two coal plants that provide 95 percent of Kosovo’s energy production. After conducting a scoping visit to Pristina, Kosovo, Lake Gazivode/Ujmani, and Belgrade, Serbia, in October 2020, PNNL staff compiled hydrometeorological, water management operations, and power grid operations data. They analyzed the data and existing literature to provide third-party observations about and recommendations for the use of the lake. Their recommendations aim to promote regional water and energy security.

13 HYDRO ENERGY↗

Clean Grid Vision: A U.S. Perspective - Executive Summary

Clean Grid Vision: A U.S. Perspective aims to present a range of possible pathways for future grid development and call attention to some common trends. It focuses on the lessons learned through NREL’s studies of the U.S. power sector that have measured the impacts of high-penetration VRE and have tested strategies for enhancing grid flexibility and reliability. As such, this report is limited in its scope and does not attempt to review or summarize all grid integration literature. While it refers to relevant external literature to provide context when needed, this report is primarily a summary of the National Renewable Energy Laboratory’s (NREL’s) research in the past 5 years on five key topics: grid planning and operation, grid reliability at the distribution level, grid reliability at the transmission level, demand-side resources, and power markets—each corresponds to a chapter in this report. The main insights of the report are presented in this executive summary.

24 POWER TRANSMISSION AND DISTRIBUTION↗