Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “gas capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Novel Transformational Membranes and Process for CO 2 Capture from Flue Gas (FE0031731)

The objectives of this project are to develop a cost-effective design and fabrication process for a novel transformational membrane and its membrane modules that capture CO 2 from flue gas. Optimization of the novel transformational membrane, scale-up of the membrane to a prototype size of about 20" wide in continuous roll-to-roll fabrication, and construction and testing of a skid for the integrated membrane process will be performed. For the design of this membrane, we use a cost-effective polymer support and coat a thin top layer of the membrane. The simplicity of this membrane design offers a low cost for the membrane element in commercial spiral-wound (SW) configuration (<$2.00/ft 2 or $21.5/m 2 ). The prototype membrane will be used to fabricate 6 pilot-size membrane modules (each about 20" length, 3 modules each at the commercial-size diameter of 8 inches with 35 m 2 membrane area for Stage 1 and 3 modules each at 5-inch diameter with 12 m 2 membrane area for Stage 2) for testing with simulated flue gas at OSU and with actual flue gas at the National Carbon Capture Center, Wilsonville, AL using the skid to capture the CO 2 (at 60 – 90%) with at least 95% CO 2 purity. The prototype membrane modules will be in commercial SW configuration with a minimal pressure drop (<0.103 bar/meter (1.5 psi/meter)). These objectives have been achieved successfully.

20 FOSSIL-FUELED POWER PLANTS↗

Second generation non-aqueous solvents (gen2nas) for co 2 capture from natural gas combined cycle plants

This final technical report submitted to DOE/NETL presents all the research activities performed during the Cooperative Agreement DE-FE0032218 entitled Second Generation Non-Aqueous Solvents (GEN2NAS) for CO 2 Capture from Natural Gas Combined Cycle Plants, which spanned from April 2023 through March 2025. In this project, Research Triangle Institute (RTI) International has developed the second-generation of its non-aqueous solvent (NAS), herein referred to as GEN2NAS, to remove carbon dioxide (CO 2 ) from natural-gas combined cycle (NGCC) flue gas. The technology aims to substantially reduce the cost of CO 2 capture while minimizing the environmental impacts through lower secondary emissions and wastewater generated from the CO 2 capture plant.

01 COAL, LIGNITE, AND PEAT↗

New sterically hindered polyvinylamine-containing membranes for CO 2 capture from flue gas

Amine-containing facilitated transport membranes can have both high permeability and selectivity due to the reversible reaction between CO 2 and amino groups for effective carbon capture from flue gas. In this study, we have developed an improved method for the synthesis of high-molecular-weight sterically hindered polyvinylamine (PVAm) as the new fixed-site carrier in thin-film composite membranes for CO 2 capture. Commercially available PVAm was N-monomethylated into poly-N-methyl-N-vinylamine (PVAm-CH 3 ) using the stepwise reductive amination with a highly polar fluorinated alcohol as the solvent to enhance the equilibrium shift to the formation of the imine intermediate. The method prevented over-alkylation, resulting in the increased yield of the target product. PVAm-CH 3 exhibited excellent CO 2 facilitation with a CO 2 permeability of 445.7 Barrer (1 Barrer = 3.349 x 10 –16 mol m m –2 s –1 Pa –1 ) and a CO 2 /N 2 selectivity of 70.3, which are above the Robeson 2008 upper bound. The PVAm-CH 3 solution retained a sufficiently high viscosity after incorporating the aminoacid salt, 2-(1-piperazinyl)ethylamine sarcosinate (PZEA-Sar), as the mobile carrier for the membrane coating on nanoporous polyethersulfone (PES) substrates without any penetration issues. The resultant thin-film composite PVAm-CH3/PZEA-Sar membrane with a thickness of approximately 170 nm exhibited a superior CO 2 performance of 1071 GPU (1 GPU = 3.349 x 10 –10 mol m –2 s –1 Pa –1 ) and a CO 2 /N 2 selectivity of 183 at 57°C and a feed gas pressure of 111.64 kPa (1.5 psig). This PVAm-CH 3 /PZEA-Sar membrane surpassed the latest redefined 2019 CO 2 /N 2 upper bound and outperformed other polymer-based membranes. Density functional theory calculations also demonstrated that PVAm-CH 3 showed a stronger preference, relative to PVAm, toward the more efficient bicarbonate pathway. Thus, the steric hindrance effect of PVAm-CH 3 enhanced the solubility of CO 2 in the polymer matrix and resulted in the higher CO 2 permeance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhancing membrane performance for CO 2 capture from flue gas with ultrahigh MW polyvinylamine

Membranes for post-combustion CO 2 capture are required to have a high CO 2 permeance due to the limited driving force. For facilitated transport membranes synthesized with polyvinylamine (PVAm), a defect-free selective layer of <200 nm is usually required to render sufficient permeance with high CO 2 /N 2 selectivity. In order to meet such a demand through the knife-coating process, the coating solution needs to have a high viscosity at a relatively low concentration to minimize its penetration into the substrate. The demand was met by synthesizing PVAm with an ultrahigh molecular weight (MW) via inverse emulsion polymerization (IEP) in this study. Compared to solution polymerization, IEP isolates the reaction in inverse micelles suspended in a continuous organic phase, which allows excellent dissipation of the heat generated by the reaction and reduces gel formation drastically. The polymerization parameters, including monomer concentration, initiator concentration, and reaction temperature, were investigated to obtain the optimal MW of PVAm for membrane performance. As compared to solution polymerization, IEP enhanced the MW of PVAm from 1.2 to 12.7 MDa, which minimized the penetration of the coating solution into the substrate and hence the extra mass transfer resistance. The effect of MW and degree of hydrolysis of PVAm on the membrane transport properties were studied. Furthermore, by employing PVAm with a MW of 12.7 MDa to strengthen the polymer matrix, the loading of piperazine glycinate in the membrane was increased up to 85 wt.%. In conclusion, the resultant membrane achieved a CO 2 permeance of 839 GPU and a CO 2 /N 2 selectivity of 161 at the typical flue gas temperature of 57°C.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling Advanced Strippers for CO2 Capture from Gas-Fired Power Plants using Aqueous Piperazine

Energy performance of 5 m piperazine was evaluated with an advanced stripper at the pilot scale, accounting for heat loss. Modeling studies indicated that heat loss at locations other than the heat source impacted the heat duty. For strippers with excess packing, the column was the most important source of heat loss, and values as low as 0.03 GJ/hr can cause pinch and reabsorption of CO2. Solvents like 5 m PZ are more affected by heat loss in the column due to a top-side temperature pinch at high lean loading. Heat loss impacts NGCC CO2 capture more than coal-based CO2 capture. Surface temperature measurements pilot plants showed that heat loss was 50-75% controlled by natural convection. Measured heat loss was correlated with steam flowrate and wind speed and ranged from 8126 to 219668 Btu/hr, representing 35% of the measured heat rate on average. Net heat duty linearly varied with CO2 removal at low lean loading and was similar for coal and NGCC conditions at fixed removal. At 90% removal, net heat duty was about 2.5 GJ/t with 4 and 12% CO2 in the flue gas. 7 At NGCC conditions, strippers with finite packing can benefit from a flashing feed to the top of the column by using a hot bypass. A flashing feed was linked to a reduction in irreversibility of the stripper from temperature driving forces. It also reduces heat duty by up to 6% at fixed packing height and reduces packing requirement for a fixed steam heater size compared to a warm bypass. Lean loading and lean solvent rate were effective handles to maximize profitability of a fixed stripper design at low gas price. High ambient temperature operation can benefit from low pressure stripping to about 0.18 lean loading at 150 ℃ to maintain the cyclic capacity at reduced rich loading. At low gas price, the capture plant was able to maximize profitability even with a high heat duty of 2.7-3.1 GJ/t at a lean loading of 0.2-0.22 mol/mol. Heat recovery by partial water vapor condensation in a gas-liquid exchanger can be replaced by a direct contact condenser (DCC). The DCC improved gas cooling and reduced heat duty compared to the CO2 exchanger at 0.2 lean loading. The DCC when used with a 150 ℃/5.5 bar stripper can reduce the cost of capture compared to the base case by $3- 4/tonne at 15 ft of packing (optimum) but increases cost of capture by $6/tonne with a 120 ℃/2 bar stripper and 10 ft of packing (optimum). The DCC can work effectively with a solvent with a high heat of absorption and thermal stability.

Suresh Babu, Athreya↗

Dual-Bed Radioiodine Capture from Complex Gas Streams with Zeolites: Regeneration and Reuse of Primary Sorbent Beds for Sustainable Waste Management

Dual-sorbent systems are proposed for radioiodine management with a regenerated primary bed for multiple cycles of use in complex conditions and a secondary bed for disposal with higher waste loadings. Sorbent approaches for the effective capture of gaseous radioiodine (isotopes 129 I and 131 I) produced from a range of nuclear processes have been studied for over half a century. (1−5) Whether or not a sorbent (e.g., molecular sieve) is required to physically screen/trap or chemically bind a radionuclide of interest through chemisorption, the complexity of the gas stream has a large impact on the performance (e.g., loading capacity, selectivity) and active life of a sorbent bed. (3) Silver mordenite (AgZ), the U.S. Department of Energy baseline sorbent for radioiodine capture from nuclear processes, performs well within acidic conditions and at elevated temperatures (6) and can be consolidated into a chemically durable waste form for long-term disposal. (7,8) However, new sorbents are being sought because optimal capture performance of AgZ significantly decreases in dynamic oxidizing environments with competing species, and it is expensive and it contains Ag (a toxic metal). (9) Until a new sorbent is found to replace AgZ, the regeneration and reuse of AgZ is an attractive alternative to a single-use primary sorbent bed. In this regard, a primary sorbent could be designed for enhanced capture in complex gas streams and the ability to be regenerated for reuse. Here, a secondary sorbent could then be tailored for maximum iodine loading in the gas stream and chemical durability within a disposal facility.

chemisorption↗

Biphasic solvents for post-combustion CO 2 capture from natural gas flue Gas

Fossil fuel fired power plants are generally expected to remain one of the most significant global sources of electricity for decades to come. Consequently, carbon management technologies are needed to reduce or eliminate ongoing emissions from these sources. Amongst the many techniques for carbon capture, aqueous amine-based absorbents (monoethanolamine, MEA, in particular) are, presently, considered the leading technology for post-combustion CO 2 point-source capture. These technologies are nevertheless limited by their high capital and regeneration energy costs. Biphasic solvents have been identified as an attractive alternative to traditional MEA based absorbents due to their potential energy savings. Thus far, however, the research on biphasic solvents has largely focused on their performance in coal flue gas while more dilute natural gas flue gas applications have received relatively little attention. Here, this work examines the performances of two novel biphasic solvent blends, diethylenetriamine (DETA) and triethylenetetramine (TETA), in CO 2 capture from a natural gas flue gas simulant. Across several regeneration tests, both solvents achieved considerable energy savings over the benchmark MEA solution. Specifically, the energy consumption per mol CO 2 recovered for the DETA-based and TETA-based solvents was 46 % and 35 % less than that of the benchmark MEA solution, respectively. Molecular dynamics simulations were also performed to gain a deeper understanding of the phase separation phenomena that occur as a consequence of CO 2 absorption. These simulations indicated that phase change was driven by the strong interaction between the absorption products and water, while the degree of separation depended on the CO 2 loading.

Biphasic solvents↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Performance of a Natural Gas Solid Oxide Fuel Cell System With and Without Carbon Capture

The fuel cell program at the United States Department of Energy (DOE) National Energy Technology Laboratory (NETL) is focused on the development of low-cost, highly efficient, and reliable fossil-fuel-based solid oxide fuel cell (SOFC) power systems that can generate environmentally-friendly electric power with at least 90 percent carbon capture. NETL’s SOFC technology development roadmap is aligned with near-term market opportunities in the distributed generation sector to validate and advance the technology while paving the way for utility-scale natural gas (NG)- and coal-derived synthesis gas-fueled applications via progressively larger system demonstrations. The present study represents a part of a series of system evaluations being carried out at NETL to aid in prioritizing technological advances along research pathways to the realization of utility-scale SOFC systems, a transformational goal of the fuel cell program. In particular, the system performance of utility-scale NG fuel cell (NGFC) systems with and without carbon dioxide (CO2) capture is presented. The NGFC system analyzed features an external auto-thermal reformer (ATR) feeding the fuel to the SOFC system consisting of planar anode-supported SOFC with separated anode and cathode off-gas streams. In systems with CO2 capture, an air separation unit (ASU) is used to provide the oxygen for the ATR and for the combustion of unutilized fuel in the SOFC anode exhaust along with a CO2 purification unit to provide a nearly pure CO2 stream suitable for transport for usage in enhanced oil recovery operations or for storage in underground saline formations. Remaining thermal energy in the exhaust gases is recovered in a bottoming steam Rankine cycle while supplying any process heat requirements. A reduced order model (ROM) developed at the Pacific Northwest National Laboratory (PNNL) is used to predict the SOFC performance. The ROM, while being computationally effective for system studies, provides other detailed information about the state of the stack, such as the internal temperature gradient, generally not available from simple performance models often used to represent the SOFC. Such additional information can be important in system optimization studies to preclude operation under off-design conditions that can adversely impact overall system reliability. The NGFC system performance was analyzed by varying salient system parameters, including the percent of internal (to the SOFC module) NG reformation—ranging from 0 to 100 percent—fuel utilization, and current density. The impact of advances in underlying SOFC technology on electrical performance was also explored.

solid oxide fuel cell (SOFC), natural gas fuel cel↗

Evaluation of Getter Metals in Na–Al–Si–O Aerogels and Xerogels for the Capture of Iodine Gas

In this paper, sodium aluminosilicate aerogels and xerogels were evaluated as scaffolds for a variety of different getters including: Ag + , Cs + , Cu 2+ , Fe 3+ , K + , Li + , Rb + , Sb 3+ , Sn 2+ , and Sn 4+ . The exchange capacities varied widely from a near complete exchange in the case of Ag + to much lower exchange levels for some of the Sn compounds [i.e., colloidal SnO 2 , Sn(II) acetate, Sn(IV) acetate]. Several of the additives showed great promise at allowing for high iodine loadings in the base materials including the following: AgNO 3 , colloidal SnO 2 , Sn(II) acetate, Sn(IV) acetate, Cu(NO 3 ) 2 , and CuSO 4 . From the standpoint of iodine uptake as a function of getter loading, the Sn4+ showed the most promise with a getter utilization (mass of iodine divided by mass of Sn, in atomic%) of 8.4, a chemical uptake of 60.7 mass% (oxygen excluded), and an mI $m_s^{-1}$ value of 0.881; these are some of the highest values reported to date for inorganic iodine sorbents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of ammonia with methanol, liquefied natural gas and conventional marine transportation fuels through life cycle cost and emissions analysis

This work evaluates ammonia as a potential marine fuel for a SUEZMAX tanker and compares it with methanol, liquefied natural gas, and conventional fuel oils. The motivation arises from the need to identify low-emission, cost-competitive fuel options that can reduce greenhouse gas emissions from international shipping. The central hypothesis is that ammonia produced from renewable energy sources can achieve lower well-to-wake greenhouse gas emissions with varying life cycle costs based on the region. Life cycle assessment and techno-economic analysis were performed for a thirty-year vessel lifetime on two representative trade routes: from Saudi Arabia to Japan and from Saudi Arabia to the Netherlands. Four ammonia production pathways were assessed: natural gas, natural gas with carbon capture, natural gas pyrolysis, and renewable electricity–based synthesis. Results show that wind-based ammonia produced in Saudi Arabia achieved the lowest life cycle well-to-wake greenhouse gas emissions, between 0.58 and 0.64 million metric tons, among all fuels when using regional grid process electricity. With renewable process electricity, ammonia produced from natural gas pyrolysis in Saudi Arabia showed comparable emissions of 0.37 to 0.44 million metric tons with wind-based ammonia of 0.37 to 0.43 million metric tons. Liquefied natural gas exhibited the lowest life cycle cost, between 402 and 412 million United States dollars, and the only negative carbon abatement cost, ranging from −277 to –322 United States dollars per metric ton of greenhouse gas, compared with high sulfur fuel oil. The findings indicate that renewable ammonia offers a promising long-term pathway for reducing shipping emissions, while liquefied natural gas remains the most cost-effective option in the near term.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flue Gas CO 2 Capture via Electrochemically Mediated Amine Regeneration: Desorption Unit Design and Analysis

We analyzed the performance of an electrochemical desorption unit to be implemented in an electrochemically mediated amine regeneration (EMAR) process, which separates CO 2 and regenerates the amine upon modulation of a targeted species that complexes with the amine molecules. Using a simplified one-dimensional boundary layer model, we combined the kinetic expressions of the faradaic reactions with mass transfer effects to analyze the polarization behavior of the flow cell. Mass transfer limitations become dominant at high current densities, leading to increases in energy consumption. An understanding of scaling laws with key parameters, such as the Sherwood number, is required to achieve high power operation with minimal mass transfer losses. Because the EMAR chemistry is sensitive to temperature, heat distribution in the unit is also examined. Our results indicate that the desorption performance increases with addition of a high-temperature heat source. Additionally, incorporation of membrane crossover suggests energy losses because of diffusion and migration of active species. Furthermore, these findings inform on scaling laws for at-scale desorber design and provide a model for scaling up the EMAR system for larger scale operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two-stage membrane-based process utilizing highly CO 2 -selective membranes for cost and energy efficient carbon capture from coal flue gas: A process simulation study

Membrane technology for CO 2 capture has become an attractive strategy due to its cost and energy efficiency and low materials costs. In the past decade, membrane-based process designs for post-combustion power plant CO 2 capture have been developed, utilizing existing highly CO 2 -permeable membranes with relatively low CO 2 /N 2 selectivity (<50), and have obtained reasonably economic carbon capture. However, few membrane-based process designs were proposed for moderate to highly CO 2 -selective membranes (CO 2 /N 2 selectivity of 50–300, and >300, respectively), which have vastly emerged in recent years, such as various facilitated transport membranes (FTMs). Herein, we proposed a two-stage membrane-base process design targeting economic carbon capture from coal-fired flue gas. This process design features the utilization of highly CO 2 -selective membranes for one-stage CO 2 enrichment to 95% dry-base purity in the first stage and recycle of the remaining CO 2 by a highly CO 2 -permeable membrane in the second stage, in order to achieve economic CO 2 capture with 90% capture rate and >95% CO 2 product purity. Through an integration-iteration membrane model and the Aspen Plus process simulation, a sensitivity study of operating pressures (feed and permeate pressures) and membrane properties (CO 2 permeance and CO 2 /N 2 selectivity) was conducted. Critical CO 2 /N 2 selectivity of 300–400 was found for the highly CO 2 -selctive membranes to meet the demand for cost and energy efficient results. The lowest possible membrane area of 4.8 × 10 5 m 2 and fractional energy of 19.3% were obtained, which is comparable to or even more attractive than reported membrane-based process designs. Here, this work provides a new membrane process design option for highly CO 2 -selective membranes and gives insights on the influence of membrane performance and operation condition.

42 ENGINEERING↗

Direct, efficient and selective capture of low concentration of CO 2 from natural gas flue gas using a high temperature tubular carbon capture membrane

Natural gas (NG) fired power plants emit low concentration (4–5%) of CO 2 , which presents additional technical and economic challenges to the current benchmark amine absorption technology. The newly emerged high-temperature multiphase membranes operated on molten carbonate (MC) chemistry for CO 2 capture/separation/conversion have been demonstrated with great potential to meet this challenge. In this study, we report on the CO 2 capture performance of such a membrane in tubular geometry from a mockup NG flue gas. The membrane is comprised of a mixture of Gd 0.20 Ce 0.80 O 1.95 (GDC) and MC, in which GDC forms a porous skeleton to contain MC. Here, we show that the membrane with a dimension of 6.1 mm in outer diameter, 5.1 mm in inner diameter and 5 cm in effective length (resulting in 4cm 2 effective surface area) can achieve a CO 2 flux density of 0.46–0.55 mL/min·cm 2 at 650°C, capturing 97% pure CO 2 at a rate of 37–42% from 5%CO 2 –N 2 using moistened Ar as the sweep gas. The level of performance demonstrated by this study suites the membrane well for stationary CO 2 capture from NG power plants.

03 NATURAL GAS↗

Costs and Performance for Coal and Natural Gas Plants with Carbon Capture

Presentation of Latest DOE/NETL estimates for baseline costs and performance for coal and natural gas plants with carbon capture. Results will include cases: a) Biomass co-firing (CBECCS), and b) Partial capture of CO2. Presented at the Air and Waste Management Association CCUS Webinar on March 3, 2021.

Fout, Timothy↗

Performance and Cost Potential of sCO2 Bottoming Cycle for Gas Turbines with Carbon Capture – Paper 32

This study investigates the performance and economic potential of sCO2 bottoming cycles for H-class gas turbine-based NGCC plants with a post-combustion capture system. A portion of the gas turbine exhaust heat is used for the generation of steam required for a solvent-based capture system while the rest of the waste heat is utilized in an sCO2 bottoming cycle for power generation. Overall, the performance and LCOE of investigated sCO2 bottoming cycles are similar to those of a state-of-the-art triple-pressure reheat steam Rankine cycle. As the gas turbine exhaust temperature increases (beyond 630oC), sCO2 bottoming cycles begin to show greater performance and economic benefits compared to a steam Rankine cycle with ~0.7 percentage point higher plant efficiency and 1.4% lower LCOE.

Pidaparti, Sandeep↗

Natural Gas Combined Cycle Carbon Capture Retrofit Database

This tool provides high-level analysis on the incremental costs for retrofitting natural gas combined cycle plants with carbon dioxide capture and/or compression systems. Options are available to include costs of other technological improvements that would be required to comply with various environmental regulations when installing carbon capture technology. This model is based on the NETL report "Cost and Performance of Retrofitting NGCC Units for Carbon Capture" (2023).

03 NATURAL GAS↗